Simpson Electric 3300 Series Rugged Seal Meter Relay Data Sheet

• Wide Variety of Control, Alarm, and Limit Use
• Calibration Not Affected by Steel Panel Mounting
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust Proof
Accuracy: Movement: Suspension: Tracking: Repeatability:
Shielding: Response Time:
Overload (1 sec.): Overload (Continuous):
Dial:
Case: Voltage Drop: Pointer: Scale Length: Net Weight: Control Point(s) Adjustments:
Switching: Differential: Auto/Manual Reset:
Contacts/Output Relay: Frequency Response:
Power: Operating Temperature: Circuit-to-Ground Voltage: NOTE:
AC: ±3% of full scale; DC: ±2% F.S. Annular, self-shielding Pivot and jewel ±3% Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S. Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used. Sealed metal, plastic window
50mV Black, knife-edge
4.05" (103.0mm) 17oz (0.48kg) Single, high limit, 0-100% of arc; double, low limit 0­95% of arc; high limit 5-100% of arc Adjustable to within 4° of each other
Within 1% of indication “On,” “Off” difference is within 0.5% of F.S. Latching function can be enabled independently for each relay by removing jumpers on terminal block
DPDT relay contacts for each control point; Each set of contacts rated at 5 amps, 120/240 VAC resistive. 50-1000Hz 108-132 VAC, 50-400Hz +41°F to 122°F (5°C to +50°C)
250V rms maximum DC meters meet ANSI specification C-39.1
Dimensions
4 - 1/2”-Model 3344AIXA & 3324AIXA
3 - 1/2”-Model 3343AIXA & 3323AIXA
1
=Panel Meter Cut-out Dimensions
Specifications
Loading...