Simpson Electric 228 Data Sheet

228 Leakage
1
Rev. 04-15
Current Tester
Model 228 Special Purpose AC/DC Milliameter
Designed specically to measure hazardous "Leakage Currents" or "Touch Currents" which may appear when a person touches the conductive surface of electrical or electronic equipment.
The 228 is designed around IEC990, ANSI and UL guidelines.
• True RMS Readings
• Output Allows Measurement of Peak Current in Non-Sinusoidal Wave Forms
• Let-Go, Reaction, and Burn Hazard Response Networks
• Detects dangerous AC & DC Leakage currents
• Includes Test Leads, Alligator Clips, Batteries and Manual
Ordering Information
Leakage Tester Catalog Number
228 Leakage Current Tester 40027
Accessories Catalog Number
Test Leads w/Screw-On Alligator Clips 00125
Case, Black Padded Nylon Carrying 00834
Optional carrying case includes convenient storage pouch for test leads and Operators Manual
228 Leakage
2
Rev. 04-15
Current Tester
Specications
The specications apply to sinusoidal AC waveforms only. Accuracy is not guaranteed for non-sinusoidal or complex waveforms.
General
Equivalent network component values Designed around IEC 990 (excluding fuse) Equivalent measuring instrument load 1 MΏ - 10 pF 1 MΏ - 62 pF 1 MΏ - 1 pF Ranges 0.3, 1, 3, 10 M.I.U. 0.3, 1, 3, 10 M.I.U. 0-100 mA RMS Current accuracy ±2% F.S. @ 60 Hz Meter measurement method True RMS Meter frequency response (Relative to ANSI C101-1992 or UL-1459 2nd edition) DC to 1 Hz Pointer shall track within 5% of peak 2Hz to 19Hz (Accuracy not supported) 20 Hz to 200 KHz ±2% F.S. ±2.5% F.S. ±2% F.S. 200 KHz to 1 MHz ±2% F.S. ±2.5% F.S. ±5% F.S. Output sensitivity Full scale meter indication equals 1V RMS (Measured with a 1 MΏ , 12 pF load) Output accuracy ±2% of reading @ 60 Hz Output frequency response (Relative to ANSI C101-1992 or UL-1459 2nd edition) DC to 50Hz ±2% of reading 50 Hz to 100 KHz ±2.5% of reading +2% / -3% of reading ±2% of reading 100 kHz to 1 MHz ±5% of reading Voltmeter range 0-300 V (AC or DC) Voltmeter accuracy: DC to 1 Hz Pointer shall track within 5% of peak 2Hz to 19Hz (Accuracy not supported) 20 Hz to 1KHz ±3% F.S. @ 60 Hz (Add ±1% for every additional 100 Hz) Voltmeter frequency response DC to 1 KHz Power requirements (2) 9V (NEDA 1604A) batteries Physical 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input Environmental 27°C ±2° C, 70% non condensing relative humidity Maximum operating range 0° to 40° C
Reaction
Response Network
Let-Go
Response Network
Unweighted Burn Hazard
Response Network
Specications subject to change without notice
Any discussion in this document regarding UL, ANSI or IEC specications is for Reference purposes only.
The input network utilized in the M228 is detailed in Figures 1 through 3 on page 4 of the Manual. The customer is advised to obtain the latest specication from the rating agency.
NOTE: For specication information call ANSI at (212) 642-4900 or UL in Northbrook, IL at (847) 272-8800.