![](/html/a2/a2c6/a2c6ed5f5133512f097cfdf8fbe499c45b78958389b147274c31783d2543b5f4/bg1.png)
228 Leakage
Current Tester
Model 228 Special Purpose AC/DC Milliameter
Designed specically to measure hazardous "Leakage Currents" or "Touch
Currents" which may appear when a person touches the conductive surface
of electrical or electronic equipment.
The 228 is designed around IEC990, ANSI and UL guidelines.
• True RMS Readings
• Reads in Measurement Indication Units (MIU) up to .005 MIU
• Output Allows Measurement of Peak Current
in Non-Sinusoidal Wave Forms
• Let-Go, Reaction, and Burn Hazard Response Networks
• Detects dangerous AC & DC Leakage currents
• Includes Test Leads, Alligator Clips, Batteries and Manual
Ordering Information
Leakage Tester Catalog Number
228 Leakage Current Tester 40027
Accessories Catalog Number
Test Leads w/Screw-On Alligator Clips 00125
Case, Black Padded Nylon Carrying 00834
Optional carrying case includes convenient
storage pouch for test leads and Operators
Manual
![](/html/a2/a2c6/a2c6ed5f5133512f097cfdf8fbe499c45b78958389b147274c31783d2543b5f4/bg2.png)
228 Leakage
Current Tester
Specications
The specications apply to sinusoidal AC waveforms only.
Accuracy is not guaranteed for non-sinusoidal or complex waveforms.
General
Equivalent network component values Designed around IEC 990 (excluding fuse)
Equivalent measuring instrument load 1 MΏ - 10 pF 1 MΏ - 62 pF 1 MΏ - 1 pF
Ranges 0.3, 1, 3, 10 M.I.U. 0.3, 1, 3, 10 M.I.U. 0-100 mA RMS
Current accuracy ±2% F.S. @ 60 Hz
Meter measurement method True RMS
Meter frequency response (Relative to ANSI C101-1992 or UL-1459 2nd edition)
DC to 1 Hz Pointer shall track within 5% of peak
2Hz to 19Hz (Accuracy not supported)
20 Hz to 200 KHz ±2% F.S. ±2.5% F.S. ±2% F.S.
200 KHz to 1 MHz ±2% F.S. ±2.5% F.S. ±5% F.S.
Output sensitivity Full scale meter indication equals 1V RMS (Measured with a 1 MΏ , 12 pF load)
Output accuracy ±2% of reading @ 60 Hz
Output frequency response (Relative to ANSI C101-1992 or UL-1459 2nd edition)
DC to 50Hz ±2% of reading
50 Hz to 100 KHz ±2.5% of reading +2% / -3% of reading ±2% of reading
100 kHz to 1 MHz ±5% of reading
Voltmeter range 0-300 V (AC or DC)
Voltmeter accuracy:
DC to 1 Hz Pointer shall track within 5% of peak
2Hz to 19Hz (Accuracy not supported)
20 Hz to 1KHz ±3% F.S. @ 60 Hz (Add ±1% for every additional 100 Hz)
Voltmeter frequency response DC to 1 KHz
Power requirements (2) 9V (NEDA 1604A) batteries
Physical 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input
Environmental 27°C ±2° C, 70% non condensing relative humidity
Maximum operating range 0° to 40° C
Reaction
Response Network
Let-Go
Response Network
Unweighted Burn Hazard
Response Network
Specications subject to change without notice
Any discussion in this document regarding UL, ANSI or IEC specications is for Reference purposes only.
The input network utilized in the M228 is detailed in Figures 1 through 3 on page 4 of the Manual.
The customer is advised to obtain the latest specication from the rating agency.
NOTE: For specication information call ANSI at (212) 642-4900 or UL in Northbrook, IL at (847) 272-8800.