Specifications
DC VOLTAGE
PHYSICAL
Dimensions: 6.5" (H) x 5.0" (W) x3.2" (D), (16.5 x 12.7 x 8.1cm)
Weight: 2.75 lbs. (1.24kg)
Moisture Resistance: 100%
Temperature: -40° to 85°
POWER REQUIREMENTS
Two 9-volt alkaline batteries
One 1.5 volt alkaline D-cell
Specifications subject to change without notice.
TS112 Railroad Tester
Designed for today's railroad equipment, the flexible TS112 is also compatible with
older technologies while offering features and functions unavailable on standard
VOM's. Fewer jacks, more ranges and a comprehensive front panel guarantee the
simplicity and the user-friendly structure of the TS112. The TS112 railroad tester
measures parameters with greater accuracy: resistance with a Multi-Turn Ohms
Adjust Control, Relay Contact On-Time without adjustment, Code Rate without
counting pointer swings, On-Time with live signals as well as relay contacts, and
automatic measurement of Peak Levels. Regulating the peak level is possible
without constantly readjusting the Tester.
The following standard features are exclusive only to the TS112 Railroad Tester.
Multimeter for Railroad Servicing
•
Auto-polarity on all DC function. Red Negative Indicator LED
•
Ohmmeter Voltage Mode detects foreign voltage of either polarity
•
Power savings Sleep Feature prevents draining of batteries
•
Measures Pulse Code Transmit and receives currents independently
AC VOLTAGE
AC CURRENT
DC CURRENT
CODE MEASUREMENT SPECIFICATIONS
OHMMETER
DRY CONTACT FUNCTIONS
ACCESSORIES Catalog No.
Case, Yellow Padded Nylon 00832
ACCESSORIES Catalog No.
Lead Set, Crocodile Reverse Banana 07540
Case, Black Padded Nylon 00834
Catalog No.
TS112 Railroad Tester 12112
Ordering Information
Ranges Accuracy Specifications
0.6VDC, 3VDC, 15VDC, 60VDC,
300VDC
⫾1.5% of Full Scale
1000 ohms per volt
Ranges Accuracy Burden Volts
15mA, 60mA 300mA, 1.5A, 6A,
30A
⫾1.5% of Full Scale
60mV
Ranges Accuracy Specifications
1.5VAC, 3VAC, 15VAC, 150VAC,
300VAC, 600VAC
⫾3% of Full Scale
288 ohms per volt
Ranges Accuracy Burden Volts
1.5 ACA, 6 ACA, 30ACA
⫾1.5% of Full Scale
60mV
Ranges Center Scale Accuracy
Rx1
Rx100
5⍀
500⍀
⫾2% of Scale Length
⫾2% of Scale Length
Ranges Accuracy
On Time:
Rate:
0-100%
30 to 500cpm
⫾3% of Full Scale from 10%
to 100%
⫾3% of Scale Length
Ranges Accuracy
On-Time Rate
0-100% 30-500 Cycles per
minute
⫾2% of Full Scale
from 10% to 100%
Normal: Poin ter fol low s contact closure Open Closed
Zero ⫾ 3.0% Full Scale ⫾0.5%
Peak Hold: Pointer will deflect to full scale and remain there with a 2.0 millisecond or longer
contact closure