Specifications
DC VOLTAGE
PHYSICAL
Dimensions: 6.5" (H) x 5.0" (W) x3.2" (D), (16.5 x 12.7 x 8.1cm) Weight: 2.75 lbs. (1.24kg) Moisture Resistance: 100% Temperature: -40° to 85°
POWER REQUIREMENTS
Specifications subject to change without notice.
TS112 Railroad Tester
Designed for today's railroad equipment, the flexible TS112 is also compatible with older technologies while offering features and functions unavailable on standard VOM's. Fewer jacks, more ranges and a comprehensive front panel guarantee the simplicity and the user-friendly structure of the TS112. The TS112 railroad tester measures parameters with greater accuracy: resistance with a Multi-Turn Ohms Adjust Control, Relay Contact On-Time without adjustment, Code Rate without counting pointer swings, On-Time with live signals as well as relay contacts, and automatic measurement of Peak Levels. Regulating the peak level is possible without constantly readjusting the Tester.
The following standard features are exclusive only to the TS112 Railroad Tester.
Multimeter for Railroad Servicing
Auto-polarity on all DC function. Red Negative Indicator LED
Ohmmeter Voltage Mode detects foreign voltage of either polarity
Power savings Sleep Feature prevents draining of batteries
Measures Pulse Code Transmit and receives currents independently
AC VOLTAGE
AC CURRENT
DC CURRENT
CODE MEASUREMENT SPECIFICATIONS
OHMMETER
DRY CONTACT FUNCTIONS
ACCESSORIES Catalog No.
Case, Yellow Padded Nylon 00832
ACCESSORIES Catalog No.
Lead Set, Crocodile Reverse Banana 07540 Case, Black Padded Nylon 00834
Catalog No.
TS112 Railroad Tester 12112
Ordering Information
Ranges Accuracy Specifications
0.6VDC, 3VDC, 15VDC, 60VDC, 300VDC
1.5% of Full Scale
1000 ohms per volt
Ranges Accuracy Burden Volts
15mA, 60mA 300mA, 1.5A, 6A, 30A
1.5% of Full Scale
60mV
Ranges Accuracy Specifications
1.5VAC, 3VAC, 15VAC, 150VAC, 300VAC, 600VAC
3% of Full Scale
288 ohms per volt
Ranges Accuracy Burden Volts
1.5 ACA, 6 ACA, 30ACA
1.5% of Full Scale
60mV
Ranges Center Scale Accuracy
Rx1 Rx100
5 500
2% of Scale Length2% of Scale Length
Ranges Accuracy
On Time:
Rate:
0-100% 30 to 500cpm
3% of Full Scale from 10% to 100% 3% of Scale Length
Ranges Accuracy
On-Time Rate
0-100% 30-500 Cycles per minute
2% of Full Scale
from 10% to 100%
Normal: Poin ter fol low s contact closure Open Closed
Zero 3.0% Full Scale 0.5%
Peak Hold: Pointer will deflect to full scale and remain there with a 2.0 millisecond or longer contact closure
rev_1 11/2/04