Simpson MINI-MAX M235 User Manual

Mini-Max M235 Series Digital Panel Meter
Minimum Depth Indicator - Less Than 2.5" (60mm) of Space Required Behind the Panel
Stackable Mounting Bracket Included for Easy Installation
LCD: 3-1/2 Digit, 0.5" (12.7mm) High LCD Display with Optional Negative Image, Bright Red Backlighting
LED: 3-1/2 Digit 0.56" (14.2mm) High Display
Standard Screw Terminals for Easy Installation
LCD: Four Voltage Ranges: 200mV, 2V, 20V, 200V
LED: Five Voltage Ranges: 200mV, 2V, 20V, 200V, 600V
85-250V AC or Optional 9-32V DC Power Supply
DC Voltage
LCD
LED
Simpson’s Mini-Max Voltage Indicators provide high quality, accu­racy, and reliability in a compact, 60mm deep case.
LCD display with an optional bright red, negative image backlight.
Display.
All units feature user-selectable decimal point, auto zero and limited scaling capabilities.
Installation and Panel Cutout
2.68 " (68mm)
0.88" (22.2mm)
2.68"
(68mm)
2.36" (60mm)
2.84" (72mm)
0.95" (24mm)
0.16"
(4mm)
0.13" (3.18mm) Max Panel Thickness
0.874"
(22.2mm)
A unique mounting bracket is provided to allow for vertical or horizontal stacking of multiple indicators. All Mini-Max units feature a 3/64 DIN, high-impact plastic case. The LCD units have a Clear viewing window, and the LED units have a Red viewing window.
Mounting Requirements
Insert the Mini-Max through the panel, and then slide the mounting bracket onto the Mini-Max. The mounting bracket allows Mini-Max units to be stacked side-to-side or top-to-bottom and maintain the DIN standard panel arrangements in 24mm by 72mm multiples. Panel cutout instructions for stacking multiple units are provided under “Stacking Features.”
DISPLAY Type:
7-segment LCD or LED
Height:
LCD 0.5” (12.7mm) LED 0.56” (14.2mm)
Decimal point: 3-position selectable
Overrange indication:
LCD Most signicant digit = “1” LED Blinking Display
LCD Backlighting:
Optional negative
image, red backlight
Polarity:
Auto with “-” indication, “+” implied
Power Requirements: AC Volt:
85-250VAC @40-440Hz
DC Volt: 9-32VDC
DCV
Power Consumption: (Non Fused)
85-250VAC: LCD 4.0VA (2.4W) Max
LED 3.6VA (2.16W) Max
9-32VDC: LCD 3 W Max
Isolation:
LED 2W Max 250VRMS Max
Noise Rejection
86dB Typical
CMRR: ACCURACY @ 25°C
±(0.1% of Reading ±1 count)
ENVIRONMENTAL Operating Temperature:
0 to 55°C
Storage Temperature: -10 to 60°C Relative Humidity:
0 to 85%
non condensing @ 40°C
Temperature Coecient:
(0.2% of input
0.5 digits)/ C
Warmup time: Less than 20 minutes
Analog to Digital Conversion Technique:
Integrating Dual Slope
Rate: 3 samples/second-typical
Mechanical Bezel: 0.95” x 2.84” (24mm x 72mm)
Depth: Panel cutout: 0.88” x 2.68”
2.36” (60mm) (22.2mm x 68mm)
Weight: LCD 3.5oz (99.2g)
LED 2.6oz (74g)
Case Material: 94-0, UL-rated, glass-lled
thermoplastic
Connections
IN HI+
IN LO -
DP3
INPUT SIGNAL
Range
Resolution
200mV
2V 20V 200V 600V
LCD VERSIONS
DP1
DP2
HOLD
WARNING: These instruments are designed for maximum safety to the operator when mounted in a panel according to
M235
100uV 1mV 10mV 100mV 1V
Input
Impedance
10MEG 10MEG 10MEG
9.9MEG
9.9MEG
Max Input
Unfused
100Vdc 250Vdc 250Vdc
250 Vdc 600Vdc
DP3 DP2 DP1
LED VERSIONS
POWER
DP
POS
COMMON
instructions. They are not to be used unmounted or for exploratory measurements in unknown circuits.
NEG
EXCITATION
OUT
-DC
AC LINE
+DC
IN HI+
NOT
USED
INPUT SIGNAL
IN LO -
DP2
DP1
HOLD
DP3
COMMON
POWER
DP
POS
EXCITATION
NEG
OUT
-DC
AC LINE
+DC
Input Signal: Connect the DC sig nal to be monitored to the IN HI + and IN LO - input terminals.
Input Power: For AC power, connect the AC POWER LINE to the AC LINE inputs. For optional DC power, connect the DC Supply to
the DC inputs. Observe polarity.
Decimal Point: To select a decimal point, connect the appropriate DP input pin (DP1 - DP3) to the DP COMMON output. Unused DP inputs
may remain unconnected (open).
Connect the DP COMMON output to the HOLD input. If this feature is not required, the HOLD pin may remain unconnected.Hold Option:
LCD Backlight Option:
Negative image, bright red backlighting is available for the LCD versions only. This illumination allows the unit to be read in low light areas. Backlighting power is supplied by the Mini-Max, so no additional external power is required.
Excitation Option: Excitation is available at the EXCITATION OUT Positive (POS) and Negative (NEG) terminals for powering external transmitters
or transducers. This source is isolated from the measurement input as well as the input power circuits. The voltages available are 12Vdc or 24Vdc with a maximum load current of 25mA. This feature eliminates the need to mount an external DC power
source for transducers or sensors used in your application.
Display Scaling
Stacking Features
The mounting bracket, included with every Mini-Max, can be connected together. Multiple units can be mounted in a single opening, allowing perfect alignment.
To punch one hole for multiple units, be sure to adjust the standard panel
erly in the hole.
remaining units.
TOP HALF
OF CASE
FRONT
OF METER
Using a screwdriver or thumbnail, spread the tabs on each side of the case
to unlock the top half. Lift the rear of the top half and slide it away from the front of the meter.
Scale Adjustment:
Mini-Max indicators have limited range
scaling. There are no optional connections required for these to function. The meter can be scaled down to 1/2 the value of the input, or scaled up to 2 times the value of the input, or a maximum reading of 1.999, whichever is lower.
Example: A 2 volt input has a maximum reading of 1.999 counts, so you cannot double the 2 volts, but you can make a 1
LOCKING
TAB
LCD VERSIONS
Scale Adjustment:
The "Coarse" adjustment R12 will allow a limited range of adjustment values. The "Fine" adjustment R9 allows for an adjust­ment range of approximately 1% of the "Coarse" adjustment. Apply the full scale input to the meter. Adjust R12 to be within 1% of the desired result. Then use R9 to
LED VERSIONS
Scale Adustment:
The "Coarse" adjustment RV1 will allow a limited range of adjustment values. The "Fine" adjustment RV2 allows for an adjust­ment range of approximately 1% of the "Coarse" adjustment. Apply the full scale input to the meter. Adjust RV1 to be within 1% of the desired result. Then use RV2 to
R12
R9
SCALE ADJ. FINE
SCALE ADJ. COARSE
Note: Any physical damage to the meter
during adjustment will void the warranty.
Vertical
Standard cutout
0.88" (22.2mm)
2.68" (68mm)
Vertical
SCALE ADJ. FINE
SCALE ADJ. COARSE
Note: Any physical damage to the meter
during adjustment will void the warranty.
0.071" (1.8mm) Add to standard when stacking
Horizontal
Standard cutout
0.88" (22.2 mm)
Horizontal
2.68" (68mm)
0.16" (4.0 mm)
Application Example
A company needs to monitor the power
5A DC UNIT
supply Voltage and load Current of a 12V, 4 Amp, DC
M235 LCD
motor.
Voltage: A Mini-Max 20V DC Volt Meter is installed in parallel with the 12VDC power supply. The IN HI+ terminal is connected to the positive lead of the power supply. The IN LO- terminal is connected to the negative
IN LO -
IN HI+
INPUT SIGNAL
DP3
DP2
DP1 HOLD
DP
COMMON
POS
EXCITATION
NEG
OUT
-DC
AC LINE
+DC
lead of the power supply.
Current: A second Mini-Max 5 ADC Ammeter is connected in series with the DC MOTOR. The IN HI+ terminal is connected to the pos­itive lead of the power supply. The IN LO­terminal is connected to the Positive lead of the Dc Motor. The Negative Lead of the DC motor is connected to the negative terminal of the 12VDC supply. The Mini-Max units will indicate the DC Motors supply voltage and load current.
4A
DC MOTOR
12VDC
POWER SUPPLY
Ordering Information
Your Mini-Max Voltage Indicator can be congured by making an entry for each box
Basic Unit Display DPM Power Supply Range Excitation Output**
None
0
85-250VAC
3-1/2 Digit Indicator
M235
0
Non Backlight (LCD)
1
Negative Image Red (LCD)
2
RED LED
2
9-32VDC
Note: The display Hold feature is standard and user selectable.
11
200mV
12
2V
13
20V
14
200V
15
600V***
** 25 mAdc Max output *** Not available for LCD
0
12VDC
1
24VDC
2
IN HI+
INPUT SIGNAL
20V DC UNIT
M235 LCD
IN LO -
DP3
DP2
Safety Symbols
DP
DP1
HOLD
COMMON
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not cor­rectly performed or adhered to, could result in personal injury.
The CAUTION sign denotes a hazard. It calls attention to an operating procedure, practice, or the like, which, if not correctly adhered to, could result in damage to or destruction of part or all of the instrument.
POS NEG
EXCITATION
OUT
-DC
AC LINE
+DC
Accessories
Portable
Switchboard
External shunts enable digital meters to indicate higher currents. A shunt is installed in series between the source and load. The shunt pro­duces a DCmV drop which is measured by the Mini-Max meter. The Mini-Max can be scaled to display the actual current between the load and the source. Simpson manufactures portable and switchboard shunts. Each portable shunt includes 5’ leads.
Example : 25Amp DC is to be measured. A Mini-Max M235 3 1/2 digit 200mVdc meter and 25Amp shunt, Cat. No. 06707, are selected for this application. 25Adc owing through the shunt generates 50mV which is applied to the IN HI+ and IN LO- inputs of the meter. The 50mV would normally display as 50.0 on the meter. By using the scale adjustments, the meters scale factor may be adjusted to 1/2. The meter will now dis­play 25.0 thus providing a 25 amp indication.
Ordering Information
Portable Shunts 50mV
Amps
1
5 10 15
25 30 50 75
100 150 200
Switchboard Shunts 50mV
Amps
100 150 200 250
300 400 500
Cat. Number
06700 06703 06704 06705
06707 06708 06709 06711
06713 06714 06715
Cat. Number
06500 06503 06504 06505
06506 06507 06508
SIMPSON ELECTRIC COMPANY 520 Simpson Avenue, Lac Du Flambeau, WI 54538-0099 (715) 588-3311 FAX (715) 588-3326
www.simpsonelectric.com
Printed in U.S.A.
Part No. 06-116065, Edition 17, 11/11
Loading...