SIMPOL HOME SMPO1113 w

Jiangmen Xinhui Tengsam Hardware &Electric Co., Ltd.
TEST REPORT
SCOPE OF WORK
ENERGY EFFICIENCY TESTING - CEILING FAN WITH LIGHT KITS- [See Page 2 “Model(s)"]
REPORT NUMBER
191028126GZU-005
ISSUE DATE [REVISED DATE] 4-Dec-2019 22-Apr-2022
PAGES
DOCUMENT CONTROL NUMBER
FAN-US-TRF_V1.1[05-Mar-2018] ©2018 INTERTEK
Testing Laboratory: Address:
Applicant/Manufacturer: Address:
Report No. 191028126GZU-005 Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Jiangmen Xinhui Tengsam Hardware&Electric Co., Ltd. NO.38-1 ZIYUN ROAD HUICHENG XINHUI JIANGMEN CITY ,Guangdong Province,China
Manufacturing site: Address:
Jiangmen Xinhui Tengsam Hardware&Electric Co., Ltd. NO.38-1 ZIYUN ROAD HUICHENG XINHUI JIANGMEN CITY ,Guangdong Province,China
Testing Location: Address:
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China
Product: Brand Name: Description:
Ceiling Fan with Light Kit NA The product covered by this report is a household, indoor use, fix connected ceiling fan.
Model(s):
TS-52-018;CF52878-30-MB-LED;CF52878-43-MB-LED; CF52878-53-MB-LED;CF52878-50-MB-LED; CF52878-43-MB-LED -WH; SH-CF-701
Model Similarity:
The models are all the same except for the appearance and model name.
Ratings: Date of receipt of sample(s):
120 V, 60 Hz 28-Oct-2019
Date Range of Test: 7-Nov-2019 Test standard(s) or criteria(s):
10 CFR 430, Appendix U to subpart B Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans California Code of Regulations, Title 20, Division 2, Chapter 4, Article 4, Sections 1601-1609: Appliance Efficiency Regulations
Conclusion:
The product tested complies with the Energy Efficiency Standard of DOE&CEC starting on January 21, 2020.
Prepared by: Richard Zhang Approved by: Taylor Cai Title: Engineer Title: Sr. Project Engineer
Signature: Signature:
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement uncertainty.
Page 2 of 11
Report No. 191028126GZU-005
Photos:
Photo 1 - Overall view
Page 3 of 11
Product Details
Item Model number of Unit Under Tested Serial number Condition of sample(s) Product Type Product Class Fan Size [in] Number of fan speeds Type of Fan Speed Control Fan speed controls separate from lighting controls? The capability of reversible fan action? Airflow direction Thickness of edges of blades [mm] Thickness of edges of blades [inch] Maximum distance between lowest point on the fan blades and the ceiling [inch] Minimum distance between lowest point on the fan blades and the ceiling [inch] Maximum Tip speed threshold [m/s] Maximum Tip speed threshold [fpm]
Report No. 191028126GZU-005
Data TS-52-018 NA Prototype Ceiling Fan with Light Kit Standard 52 3 Readily accessible pull chain Yes Yes Reversible
5.00
0.197
12.60
12.60
11.89 2342
Critical Components
Name Manufacturer / trademark Type / model Technical data
Fan motor
Capacitor of fan motor
LED Bulb
NOTE “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" can be used.
Jiangmen Xinhui Tengsam Hardware&Electric Co., Ltd.
YSC-52 120V/60HZ/60W
Various Various 4μF+5μF+5μF,250V
Dongguan Rongsheng Lighting
Various
A15;120V;60Hz;6.5W;E26;600L M; 3000K
Page 4 of 11
Report No. 191028126GZU-005
Sample 1, Air Delivery Test at Low Speed - First Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1015
68.2
52.2 67
Voltage V Frequency Hz Current A Power W
120.4 60
0.22
10.91
Sensor #
A B C D 1 111.44 107.79 100.43 106.11 106.44 0.0873 9.29 2 129.10 115.24 108.99 122.16 118.87 0.6981 82.99 3 141.04 126.45 128.68 139.13 133.83 1.3963 186.86 4 108.79 131.83 139.31 143.43 130.84 2.0944 274.03 5 72.58 130.62 149.50 122.81 118.88 2.7925 331.98 6 47.06 105.67 129.65 86.30 92.17 3.4907 321.73 7 30.96 70.61 79.35 47.62 57.13 4.1888 239.32 8 25.30 58.55 61.94 41.75 46.88 4.8869 229.12 9
Velocity in FPM - Axis #
Average
Vel. [FPM]
Total airflow [CFM]: 1675.31
Circle area
[sq. Ft.]
Airflow
[CFM]
Sample 1, Air Delivery Test at Low Speed - Second Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1014
70.9
51.8 67
Voltage V Frequency Hz Current A Power W
120.5 60
0.22
10.87
Sensor #
A B C D 1 107.69 96.35 101.00 103.46 102.13 0.0873 8.91 2 120.80 100.07 112.89 123.45 114.30 0.6981 79.80 3 137.15 125.43 130.28 140.47 133.33 1.3963 186.17 4 133.48 128.83 138.87 138.27 134.86 2.0944 282.46 5 115.81 116.96 141.10 113.91 121.94 2.7925 340.53 6 79.91 90.75 115.61 84.45 92.68 3.4907 323.51 7 50.36 55.95 69.53 52.80 57.16 4.1888 239.45 8 42.06 42.98 56.24 43.11 46.10 4.8869 225.27 9
Velocity in FPM - Axis #
Page 5 of 11
Average
Vel. [FPM]
Total airflow [CFM]: 1686.09
Circle area
[sq. Ft.]
Airflow
[CFM]
Report No. 191028126GZU-005
Sample 1, Air Delivery Test at High Speed - First Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1013
72.7
50.9 168
Voltage V Frequency Hz Current A Power W
120.3 60
0.50
60.26
Sensor #
A B C D 1 248.94 239.97 245.54 260.71 248.79 0.0873 21.71 2 277.54 282.77 295.27 303.16 289.68 0.6981 202.24 3 325.37 317.72 336.89 345.77 331.43 1.3963 462.77 4 344.39 345.61 363.52 356.30 352.46 2.0944 738.18 5 307.05 334.56 352.77 323.80 329.55 2.7925 920.27 6 219.15 270.58 270.99 244.85 251.39 3.4907 877.52 7 136.12 164.53 152.15 144.57 149.34 4.1888 625.57 8 102.20 125.18 111.65 120.26 114.82 4.8869 561.13 9
Velocity in FPM - Axis #
Average
Vel. [FPM]
Total airflow [CFM]: 4409.38
Circle area
[sq. Ft.]
Airflow
[CFM]
Sample 1, Air Delivery Test at High Speed - Second Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1013
71.6
51.7 168
Voltage V Frequency Hz Current A Power W
120.3 60
0.50
60.15
Sensor #
A B C D 1 256.88 239.72 241.85 264.60 250.76 0.0873 21.88 2 283.76 276.37 295.75 302.25 289.54 0.6981 202.13 3 328.61 327.38 343.85 348.92 337.19 1.3963 470.80 4 350.42 356.21 358.62 351.80 354.26 2.0944 741.96 5 322.44 345.11 326.41 311.35 326.33 2.7925 911.28 6 239.41 259.35 253.91 231.28 245.99 3.4907 858.67 7 162.71 152.30 147.51 142.79 151.33 4.1888 633.88 8 121.26 113.40 114.58 112.69 115.48 4.8869 564.35 9
Velocity in FPM - Axis #
Page 6 of 11
Average
Vel. [FPM]
Total airflow [CFM]: 4404.96
Circle area
[sq. Ft.]
Airflow
[CFM]
Report No. 191028126GZU-005
Sample 2, Air Delivery Test at Low Speed - First Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1010
70.9
54.1 72
Voltage V Frequency Hz Current A Power W
120.5 60
0.21
10.88
Sensor #
A B C D 1 98.58 95.29 98.33 91.15 95.84 0.0873 8.36 2 118.55 119.27 104.80 108.71 112.83 0.6981 78.77 3 136.14 134.40 128.61 130.36 132.38 1.3963 184.84 4 140.67 141.63 132.83 137.34 138.12 2.0944 289.27 5 117.11 140.85 124.51 122.20 126.16 2.7925 352.32 6 82.04 110.30 97.29 91.02 95.16 3.4907 332.17 7 46.66 64.49 60.41 53.60 56.29 4.1888 235.79 8 34.96 46.72 46.69 44.19 43.14 4.8869 210.81 9
Velocity in FPM - Axis #
Average
Vel. [FPM]
Total airflow [CFM]: 1692.32
Circle area
[sq. Ft.]
Airflow
[CFM]
Sample 2, Air Delivery Test at Low Speed - Second Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1011
72.9
52.4 72
Voltage V Frequency Hz Current A Power W
120.5 60
0.21
10.86
Sensor #
A B C D 1 101.61 91.18 90.23 86.06 92.27 0.0873 8.05 2 124.70 111.87 115.00 109.03 115.15 0.6981 80.39 3 135.14 130.42 136.20 136.59 134.59 1.3963 187.92 4 139.99 139.73 146.49 139.24 141.36 2.0944 296.07 5 127.34 135.86 131.99 127.71 130.72 2.7925 365.05 6 90.77 93.59 95.49 96.94 94.20 3.4907 328.80 7 53.25 51.31 55.79 56.02 54.09 4.1888 226.58 8 40.46 36.32 45.69 45.79 42.06 4.8869 205.56 9
Velocity in FPM - Axis #
Page 7 of 11
Average
Vel. [FPM]
Total airflow [CFM]: 1698.42
Circle area
[sq. Ft.]
Airflow
[CFM]
Report No. 191028126GZU-005
Sample 2, Air Delivery Test at High Speed - First Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1016
68.4
53.2 176
Voltage V Frequency Hz Current A Power W
120.2 60
0.49
58.34
Sensor #
A B C D 1 261.61 252.58 266.14 252.84 258.29 0.0873 22.54 2 285.67 282.76 298.93 294.25 290.40 0.6981 202.74 3 329.20 324.51 338.00 334.89 331.65 1.3963 463.07 4 349.94 350.88 355.75 355.81 353.10 2.0944 739.52 5 315.91 348.58 341.45 323.85 332.45 2.7925 928.36 6 234.30 257.50 261.72 246.86 250.10 3.4907 873.00 7 136.31 145.11 151.54 151.10 146.02 4.1888 611.63 8 103.49 113.05 128.10 128.19 118.21 4.8869 577.67 9
Velocity in FPM - Axis #
Average
Vel. [FPM]
Total airflow [CFM]: 4418.53
Circle area
[sq. Ft.]
Airflow
[CFM]
Sample 2, Air Delivery Test at High Speed - Second Set
Item Unit Value Item Unit Value Barometric pressure hPa Room temperature °F Relative humidity % Rotate speed RPM
1011
73.6
51.5 176
Voltage V Frequency Hz Current A Power W
120.2 60
0.48
58.09
Sensor #
A B C D 1 245.45 263.63 252.46 266.29 256.96 0.0873 22.42 2 282.14 275.19 293.52 305.74 289.15 0.6981 201.86 3 334.21 319.90 335.71 348.34 334.54 1.3963 467.11 4 355.77 345.75 354.27 361.56 354.34 2.0944 742.12 5 325.85 336.62 337.97 319.78 330.05 2.7925 921.68 6 240.57 258.65 256.01 232.37 246.90 3.4907 861.85 7 148.26 151.38 147.51 135.74 145.72 4.1888 610.40 8 110.94 112.74 118.26 110.40 113.08 4.8869 552.63 9
Velocity in FPM - Axis #
Page 8 of 11
Average
Vel. [FPM]
Total airflow [CFM]: 4380.08
Circle area
[sq. Ft.]
Airflow
[CFM]
Report No. 191028126GZU-005
Standby power
Item Unit Sample 1 Sample 2 Applied voltage V 120 120 Frequency Hz 60 60 Total harmonic content % 1.03 1.03
Accumulated energy
Period of measurement
Standby or off mode power W 0.00 0.00
mWh 0 0
min 10 10
Page 9 of 11
Report No. 191028126GZU-005
Conclusion(Standard)
Item
Airflow [CFM] Power [W]
Low High Low High Sample 1 1680.70 4407.17 10.89 60.21 0.00 84.37 Sample 2 1695.37 4399.31 10.87 58.21 0.00 86.94 Number of samples 2 2 2 2 2 2 Mean 1688.04 4403.24 10.88 59.21 0.00 85.66 Standard deviation 10.37 5.56 0.01 1.41 0.00 1.82
LCL
/0.9 for Airflow
0.90
and Efficiency
1850.51 4879.04 N/A N/A N/A 90.77
Standby
[W]
Efficiency
[CFM/W]
UCL
/1.1 for Power
0.95
N/A N/A 9.95 59.54 0.00 N/A
Declarable value 1688.04 4403.24 10.88 59.54 0.00 85.66 Minimum Efficiency on and after January 21, 2020 Verdict
71.83 Pass
FTC EnergyGuide(DOE ONLY)
Item Standard Hugger Airflow (weighted-average) 3130 N/A Energy Use 37 N/A Airflow Efficiency 86 N/A Estimated Yearly Energy Cost 10 N/A
Unit CFM
W
CFM/W
$
Page 10 of 11
Revision Summary
Date/
Proj # Site ID Reviewer
11-Mar-2020
200305085G ZU
Project Handler/
Elvis Cai
Felix Li
Item Description of Change
Page 2
Test
standard(s)
or criteria(s):
Added on California Code of Regulations, Title 20, Division 2, Chapter 4, Article 4, Sections 1601-1609: Appliance Efficiency Regulations
Changed "This report is compliance with Minimum
Page 2
Conclusion
Efficiency on and after January 21, 2020 of Ceiling Fans" to "The product tested complies with the Energy Efficiency Standard of DOE&CEC starting on January 21, 2020."
Page 4 Critical
Components
Added the Light Bulb Manufacture : Dongguan Rongsheng Lighting
Report No. 191028126GZU-005
22-Apr-2022
220414151G ZU
Jacky Liang
Taylor Cai
Page 4 Critical
Components
Added the Light Bulb Technical data : A15;120V;60Hz;6.5W;E26;600LM;3000K
Page 2 Added the model of SH-CF-701
--THE END--
Page 11 of 11