Simpnic S1 User Manual

S1
IoT Gateway
Version: 1.0
Revision History
Version
Date
Changes
1.0
10/26/2018
First release
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the authority to operate equipment.
This device and its antenna must not be co-located or operating in conjunction with any other
antenna or transmitter
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection
of other channels is not possible
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
Trademarks
SiMPNiC is a registered trademark of Connection Technology Systems Inc. All trademarks belong to their respective proprietors.
Contents subject to change without prior notice.
Copyright Statement
Connection Technology Systems Inc Copyright © 1998-2018
This publication may not be reproduced as a whole or in part, in any way whatsoever unless prior consent has been obtained from Connection Technology Systems Inc.
ii
Contact Information
Headquarter/Manufacturer:
Connection Technology Systems Inc.
18F-6, No.79, Sec.1, Xintai 5th Rd., XiZhi Dist., New Taipei City 221, Taiwan(R.O.C) Tel: +886-2-2698-9661 Fax: +886-2-2698-9662 Dir.Line:+886-2-2698-9201
www.ctsystem.com www.simpnic.com
Global Authorized Representatives:
Connection Technology USA Inc.
40538 La Purissima Way, Fremont, CA 94539, USA Tel: +1-510-509-0304 Sales Direct Line: +1-510-509-0305
E-mail:cts_us@ctsystem.com
Connection Technology Systems Japan
Higobashi Bldg, No3 R201, 1-23-13, Edobori, Nisi-ku, Osaka 550-0002, Japan
Tel: +81-6-6450-8890 E-mail: cts_japan@ctsystem.com
Connection Technology Systems NE AB
August Barks Gata 21, 421 32 Västra Frölunda, Sweden Tel: +46-31-221980
E-mail: info@ctsystem.se
COMPONET Handels GmbH
Hirschstettner Straße 19-21/Stiege I A-1220 Wien, Austria Tel: +43-1-2350-5660 E-mail: office@componet.at
iii
Table of Contents
Revision History ....................................................................................... ii
CONTACT INFORMATION ........................................................................... III
TABLE OF CONTENTS .............................................................................. IV
CHAPTER 1. INTRODUCTION ...................................................................... 2
1.1 OVERVIEW OF S1 ................................................................................ 2
1.2 KEY FEATURES .................................................................................. 3
1.3 REAR & SIDE & TOP PANELS ................................................................... 5
1.3.1 Rear Panel ............................................................................... 5
1.3.2 Side and Top Panels ................................................................... 6
1.4 LED DEFINITIONS ............................................................................... 7
1.5 BUTTONS DESCRIPTION ......................................................................... 8
CHAPTER 2. INSTALLATION ....................................................................... 9
2.1 INSTALLATION REQUIREMENTS ................................................................. 10
2.2 CHECKING THE PACKAGE CONTENTS .......................................................... 10
2.3 INSTALLING S1 GATEWAY ...................................................................... 11
2.3.1 Wall-Mounting Installation ............................................................ 11
2.4 CONNECTING S1 GATEWAY TO NETWORK ..................................................... 12
CHAPTER 3. OPERATION .......................................................................... 13
3.1 NETWORK MANAGEMENT ....................................................................... 13
CHAPTER 4. MAINTENANCE ...................................................................... 14
4.1 FAULT IDENTIFICATION ......................................................................... 14
4.1.1 Local Check ............................................................................ 14
4.2 HARDWARE REPLACEMENT PROCEDURES ..................................................... 15
4.3 FIRMWARE UPGRADE ........................................................................... 15
iv
About this manual
In this user’s guide, it will not only clearly introduce SiMPNiC S1 Gateway but tell you how to install this gateway with detailed instructions.
Organization of the Manual
Chapter 1 “Introduction” describes the features of the S1 Gateway  Chapter 2 “Installing the S1 Gateway Chapter 3 Operation Chapter 4 Maintenance
Publication date: Oct. 26, 2018 Revision 1.0
1
Introduction
1
Introduction
SiMPNiC’s S1 Gateway is typically designed to meet the emerging Internet of Things (IoT) Ethernet requirements. This reliable solution provides the security mechanism to prevent your network from malicious attacks.
1.1 Overview of S1
With the cutting-edge technology, SiMPNiC delivers a managed Layer 2 gateway, S1, for IoT_based services in the home automation. Through the Z-Wave transmission between the provided sensors and this gateway, the users can remotely turn on/off the electrical appliances, monitor the status of plugs/windows/doors, and so on anytime and anywhere using the SiMPNiC app we develop.
The LED indicator located on the top panel eases the users’ effort to monitor and manage the network status. In addition, you can easily mount it with the wall-mount bracket we provide as well.
Publication date: Oct. 26, 2018
Revision 1.0
2
Introduction
1.2 Key Features
Z-Wave Plus S2 Security support. Easy to use iOS& Android mobile App. Support Wi-Fi and wired network connection. Support WPS easy Wi-Fi connection. 2 x Buttons for easy Scene Control. Lightweight, Stylish Design to blend into your house. Simple installation with wall-mount kit. SiMPNiC Edge Security (SES) & Firewall. AES-128bit encryption both downstream and upstream. Utilize Secure Tunnel to communicate with mobile App. Anti-Tampering Firmware Design. Emergency Boot to recover Firmware. Patented Open Platform to Multi-Services. Restful Open API for 3rd Party Development. USB and SD card interface to FW upgrade and config restore. Expandable Capability via USB Interface and SD card. Interfaces:
- 1 X USB 2.0(Type A) Port
- 1 X RJ-45 Ethernet 10/100Mbps Port
- 1 X Micro SD Slot
- IEEE ISM 802.11n 2T2R
Hardware:
- CPU: 1GHz
- RAM(Byte): 64MB
- FLASH(Byte): 16MB
LED:
- Status LED
Power:
- Power Source: AC-to-DC 5V micro USB Type B Adaptor
- Power Consumption: 1.3W (Min); 6.5W (Max.)
Publication date: Oct. 26, 2018 Revision 1.0