IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following. Read all instructions before using this appliance
WARNING – To reduce the risk of fire, electric shock, or injury:
1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
4. Use only as described in this manual. Use only manufacturer’s recommended attachments.
5. Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
8. Do not handle plug or appliance with wet hands.
9. Do not put any objects into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
12. Do not use without dust bag and/or filters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
16. Connect to a properly grounded outlet only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
Table of ConTenTs
Preface .................................................................................... 4
Schematic – Units without Bags ................................................. 5
Schematic – Units with Bags ...................................................... 5
Installation
Unit Installation ........................................................................ 6
Dos & Don’ts ............................................................................ 7
Mufer Installation - (CI100 and BF100 models) ........................ 10
Mufer installation - other models ............................................ 11
Electric Connections................................................................ 11
Grounding Instructions ............................................................ 12
Low Voltage Connections ......................................................... 13
Operating instruction
Hose Hook-up & Inlets............................................................. 14
Using the integrated inlet ........................................................ 15
Progressive Start .................................................................... 16
Automatic Stop ....................................................................... 16
LED indicator .......................................................................... 16
Information center .................................................................. 17
3
Operating instruction
Motor ..................................................................................... 17
Hi Flow Hepa Bag (B20, BF40, BF60 and BF100 models) ........... 18
Dirt Receptacle (C20, CI40, CI60 and CI100 models) ................ 19
Filters (C20, CI40, CI60 and CI100 models) .............................. 19
Carbon Dust Filter (BF40, BF60 and BF100 models) .................. 20
Troublehooting
General Information ................................................................ 21
Decrease in suction strength ................................................... 22
Vacuum will not start ............................................................... 24
Vacuum will not stop ............................................................... 25
Warranty Information
Limited Lifetime Warranty ........................................................ 26
4
PrefaCe
Your new Simplicity central vacuum system was designed and manu­factured in Blainville, Quebec, by the largest central vacuum cleaner manufacturer in Canada, providing a high-quality, state-of-the-art product. Our extensive network of qualified professionals ensures first quality service near you. Contact us for the location of the Simplicity authorized service center in your area.
sChemaTiC – UniTs wiThoUT bags (C20, Ci40, Ci60 and Ci100 models)
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Integrated Inlet*
5. Air Intake
6. Integrated Switch*
7. Information center*
8. Air Exhaust
9. Muffler
* except C20 model
min. 30 cm (12")
If the muffler is turned down
6
1
2
3
4
5
min. 30 cm (12")
With mufer turned down 163 cm (64")
min. 30 cm (12")
7
8
9
min. 30 cm (12")
With mufer turned up 183 cm (72")
min. 30 cm (12") Recommended 40 cm (16")
95 cm (38")
sChemaTiC – UniTs wiTh bags (b20, bf40, bf60 and bf100 models)
1. Circuit Breaker
2. Information center *
3. Low Voltage Connector
4. Serial Number
5. Upper Round Drum Filter (part #CF-B)
6. Air Intake
7. Carbon Dust Filter*
8. Muffler
* except B20 model
min. 30 cm (12")
min. 30 cm (12")
If the muffler is turned down
7
1
2
3
4
8
5
5
6
min. 30 cm (12")
With mufer turned down 163 cm (64")
min. 30 cm (12")
min. 30 cm (12") Recommended 40 cm (16")
95 cm (38")
With mufer turned up 183 cm (72")
6
UniT insTallaTion
Using the mounting plate provided with your vacuum cleaner, secure the unit to the wall (gure 1), at a height allowing easy access for maintenance of the filters, dirt receptacle and/or bags (see pages 6 and 7).
The connections to the piping system will require some basic tools: a mitre box and small saw or a pipe cutter (gure 2). See pages 9 and 10 for general instruc­tions pertaining to the preparation of PVC pipes. To simplify matters, installation kits, including neces­sary fittings, pipes, glue and wiring, as well as a detailed instructions booklet, are available from Simplicity service centers.
gure 1
gure 2
Contrary to all other connections in the piping system, do not glue the last tting to your unit. Simplicity central vacuums are equipped with an adjustable air intake valve (gure 3), which does not require glue. An air-tight fit is achieved with the screw-type adjustment on the fitting itself.
Installation
gure 3
dos & donTs
Installing Conduits
7
Installation
8
dos & donTs
Installing Conduits
Installation
dos & donTs
Installing Inlets
When installing your vacuum inlets, we recommend that the principle of electric polarity be taken into account. Ensure that the wire connected onto contact A on inlet 1 is the same as that connected to contact A on inlet 2, and so on. Do not cross, reverse or interchange wires.
A
B
A
9
Inlet 1
A
B
Inlet 1
Installation
B
Inlet 2
A
B
Inlet 2
Loading...
+ 19 hidden pages