Simplex TrueAlert 4009 Series, TrueAlert 4009-9402CA, TrueAlert 4009-9401, TrueAlert 4009-9501 Operation Reference

R
TrueAlert Addressable Notification Reference
UL, ULC, CSFM Listed; FM Approved; TrueAlert Addressable Operation Reference & MEA (NYC) Acceptance* 4009 Series TrueAlert Addressable Controller
Use for installed system expansion applications:
Refer to page 7 for appliance compatibility details For new addressable notification fire alarm control panel
applications, refer to data sheet S4100-0100
TrueAlert Addressable Operation Features
4100ES Fire Alarm Control Panel with TPS
TrueAlert addressable notification appliances
or
TrueAlert
Isolator Module
1
5
+ 24V
ZONE PWR + 0V 2
6
ZONE PWR ­3
7
+IDNET
IDC + 4
8
- IDNET
IDC -
5
1
6
2
7
3
SIMPLEX TIME RECORDER CO.
4090-9101
MONITOR ZAM, CLASS B
INSTAL. INSTR. 574-183
8
4
DATE CODE:
1
Each individually addressed notification appliance receives power and control over a single wire pair
or
Supervised wiring connections to each appliance that
support using “T-tapped” wiring for Class B circuits
Three TrueAlert
SLC Channels
(Class A circuits require in/out wiring)
Horns sounding with selectable high or low output, as
Temporal 3 or March Time pattern (60 or 120 bpm), or Steady On, controlled separately from visible appliances on the same two-wire circuit
TrueAlert
Addressable
Controller
input options
TM
TrueAlert Addressable Controller
Optional IDNet Channel Repeater
CAUTION
DISCONNECT
POWER BEFORE SERVICING
1
5
+ 24V
ZONE PWR + 0V 2
6
ZONE PWR ­3
7
+IDNET
IDC + 4
8
- IDNET
IDC -
ALARMFIRE
5
1
6
2
PULL DOWN
7
3
SIMPLEX TIME RECORDER CO.
4090-9101
MONITOR ZAM, CLASS B
INSTAL. INSTR. 574-183
8
4
DATE CODE:
1
Visible appliances operating synchronized at 1 Hz Control over power limited, isolated output Signaling
Line Circuits (SLCs) with up to 63 addressable appliances per SLC, and up to 189 appliances per control source (refer to page 7 for detailed SLC ratings)
Control sources selectable to provide individual appliance
magnetic test mode and appliance LED polling indicator
4100ES, 4100U and 4010ES systems also provide
additional control capabilities using Virtual NAC (VNAC) appliance groupings across SLCs and across control sources
Class B, “T-tapped” wiring advantages:
Less wiring distance is required since traditional
end-of-line Class B wiring supervision is not needed
With less wiring distance required, voltage drops can be
RUI Communications
4100ES, 4100U, 4010ES,
4100, 4120, or 4020 Fire
Alarm Control Panel
or IDNet
Communications
** SYSTEM I S NORM AL **
12:02:15pm Mon 9-Feb-98
FIRE
SYSTEM
SYSTEM
ALARM
AC
ALARM
SUPERVISORY
TROUBLE
SILENCED
POWER
ALARM
SUPV
TROUBLE
ALARM
SYSTEM
ACK
ACK
ACK
SILENCE
RESET
4010 Fire Alarm
Control Panel
FIRE ALARM CONTROL
CAUTION
DISCONNECT POWER BEFO SERVICING
or Wired Control
or Fiber Optic IDNet
Communications
IDNet Fiber Optic Transmitter
Non-Addressable
Fire Alarm
Control Panel
TrueAlert Addressable Operation Reference Diagram
12:02:15pm Fri 19-Feb-99
FIRE
ALARM
ALARM
ACK
**SYSTEM IS NORMAL**
SYSTEM
SYSTEM
ALARM
SUPERVISORY
TROUBLE
SILENCEDACPOWER
SUPV
SYSTEM
TROUBLE
ALARM
ACK
RESET
ACK
SILENCE
reduced, allowing more appliances per wire run
UL listed to Standard 864*
TrueAlert Addressable Controllers (Contd.)
Extensive internal diagnostics include:
4100ES TrueAlert Power Supplies (TPS)
For mounting in 4100ES/4100U control panels:
Three, 3 A, SLCs (Special Application rating)
TrueAlert Addressable Controllers
Remote mounted control panel that provides:
Three, 2.5 A, SLCs (Special Application rating) An 8 A power supply/battery charger for internal
batteries up to 12.7 Ah or up to 18 Ah in external cabinet
Multiple communications formats are available:
Remote Unit Interface (RUI) communications
from Simplex
®
4100ES/4010ES/4100U/4120/4100/4020 fire alarm control panels (4100U/4120/4100/4020 requires rev. 9 software or higher) assigns an address point with custom label to each appliance for individual trouble reporting
IDNet communications from Simplex 4010 fire alarm
control panels provide individual or multiple channel control using a single IDNet address
Wired control from conventional NACs connects with
multiple options
S4009-0003-10 9/2015
LED status indicators that identify channel and trouble Support for host fire alarm control panel WALKTEST
system test with IDNet or RUI communications**
Status monitoring of battery, input power, and earth
faults
Optional internal modules:
Class A Three Channel Adapter Module IDNet Communications: Repeater or Fiber Optic
Receiver/Repeater; models for Class A or Class B
External accessories:
IDNet communication fiber optic transmitters Remote TrueAlert communications isolator 4905-9929,
refer to data sheet S4905-0001 for details
External battery cabinet for 18 Ah batteries
* NOTE: Model 4009-9501 (240 VAC input) is not included in these listings. Refer to
page 2 for specific applicable listings by model. 4009-9401 (120 VAC input) has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7310-0026:214 for allowable values and/or conditions concerning material presented in this document. 4009-9401 is accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products..
Introduction
TrueAlert addressable notification appliances are
individually addressed and receive power, supervision, and control from a TrueAlert Signaling Line Circuit (SLC). For wired control systems, strobe flashes and horn outputs are synchronized per controller. For RUI and IDNet communications control, controllers on the same host control panel are synchronized. (Combination
RUI Communications Control (Continued)
Address points and custom labels are assigned to each
TrueAlert appliance allowing troubles to be reported individually. Additionally, individual device types are assigned and audible appliance coding types are selectable for high or low output (~5 dBA difference) and with operation as Temporal pattern, March Time pattern (60 or 120 bpm), or Steady On (continuous).
speaker/strobe TrueAlert appliances receive audible control from separate audio circuit wiring.)
TrueAlert addressable operation allows strobes to be wired onto the same two-wire SLC circuit as horns but with separately controlled operation. Typical applications are audible notification appliances activated as “on-until-silenced” and visible notification appliances activated as “on-until-reset.”
TrueAlert Addressable Controller diagnostics can be implemented from the control panel including: Silent or Active individual appliance magnet test, appliance LED polling indication, or all appliance LEDs on.
RUI Communications Control
When used with fire alarm control panels that support RUI communications, the TrueAlert Addressable Controller can be connected to an RUI addressable communications channel along with other RUI addressable devices. The host panel can control multiple TrueAlert Addressable Controllers (maximum recommended is 20 per RUI connection), (note: 4010ES system is limited to 20 internal and external card addresses per panel). Refer to the diagram on page 3 for additional information.
4100ES and 4010ES VNAC Details
Virtual NAC (VNACs) Operation Groupings
provide control of TrueAlert appliances similar to conventional NAC operation but VNACs include appliances across SLCs and across SLC sources within a 4100ES (or 4100U) or 4010ES controlled system. VNACs require point allocation, can be declared “public” for use in a Network fire alarm system, and can be manually controlled. (NOTE: The terms Virtual NAC, VNAC, and TrueAlert Zone refer to the same feature and are interchangeable.)
Custom VNACs. For programming convenience, there are default VNAC groups according to device type. Up to 56 custom VNACs (8 VNACs are system reserved) can be created per 4100ES TPS or per TrueAlert Addressable Controller connected to a 4100ES or 4010ES control panel. Appliances are able to be in up to three custom VNACs. (NOTE: Appliances assigned to multiple VNACs will remain ON if any of the VNACs are ON.)
4100ES, 4100U, and 4010ES Fire Alarm Control Panels can be programmed for up to 247 total custom VNACs for increased selective signaling operation.
TrueAlert Addressable Controller Product Selection
Standard Models
Model Listings Input Voltage Description
4009-9401* UL, FM, CSFM, MEA (NYC)
4009-9402CA ULC (includes low battery cutout feature)
4009-9501 Not agency listed 240 VAC input
Optional Modules (for on-site installation)
Model
4009-9812 Three channel Class A adapter Select if required
4009-9809 IDNet Repeater, output is Class A or Class B 4009-9810 Class B 4009-9811 Class A (Class X input)
4009-9805 Red Appliqué for door Select if required, 16-1/8” W x 5-1/2” H (410 mm x 140 mm)
2975-9801 Beige trim 2975-9802 Red trim
External Accessories (select per system requirements)
Model Description Comments
4090-9105 Class B 4090-9107 Class A (Class X output) 4905-9929 Remote TrueAlert Communications Isolator Refer to data sheet S4905-0001 for details
4009-9801
Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation)
Model Description Model Description
2081-9272 6.2 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC; requires external battery cabinet
* 4009-9401 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet S2081-0019
2 S4009-0003-10 9/2015
Description Comments
Fiber Optic Receiver with IDNet Repeater
Semi-Flush Trim Kit 1-7/16” wide (78 mm), use if required for semi-flush installations
IDNet Fiber Optic Transmitter
External battery cabinet for 18 Ah batteries, beige
120 VAC input
Select either an IDNet Repeater or a Fiber Optic Receiver as required
Mounts in six-gang electrical box, refer to page 6 for mounting details
16-1/4” W x 13-1/2” H x 5-3/4” D (413 mm x 343 mm x 146 mm)
TrueAlert Addressable Controller with 3, Class B TrueAlert SLC channels and 8 A power supply
4100ES/4100U VNAC Wiring Reference
NOTE: Refer to NFPA 72, the
National Fire Alarm Code, for requirements concerning fault tolerance between Notification Zones. Use of Isolator Modules and/or fire rated risers may be required depending on system design.
TrueAlert SLC Source
Internally mounted 4100ES TrueAlert Addressable Power Supply (TPS)
Channel 1
Channel 2
4100ES (shown) or
4100U Fire Alarm
Control Panel
or RUI controlled
TrueAlert Addressable
Controller
TM
TrueAlert Addressable Controller
Channel 3
CAUTION
DISCONNECT
POWER BEFORE SERVICING
Wiring
reference
detail
Terminal cabinet
(as required)
Locate branch circuit
terminations within 10 ft
(3 m) of TrueAlert
Addressable SLC source
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
576-733
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
Branch
1
Branch 3
Branch
2
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
576-733
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
+ ­PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ON
Simplex Time Recorder Co. Gardner, MA 01441
+ ­PORT 1
576-733
ADDRESS
MSB
+ ­PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ON
Simplex Time Recorder Co. Gardner, MA 01441
VNAC Zone 1
+ ­PORT 1
576-733
ADDRESS
MSB
VNAC Zone 2
TrueAlert wiring (twisted pair, 18 to 12 AWG)
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
576-733
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
+ ­PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ON
Simplex Time Recorder Co. Gardner, MA 01441
VNAC Zone 2
4905-9929 Isolator Modules:
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co. Gardner, MA 01441
1. Locate as required, each
576-733
MSB
takes one address and counts as 4
TrueAlert unit loads.
2. Isolator Modules are automatically assigned to the Isolator default VNAC.
3. Up to 12 total can be connected per Class B SLC (up to 6 on the same branch), and up to 6 total per Class A SLC.
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
576-733
RELAY CONTACTS
MODULE
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
VNAC Zone 1
VNAC Details:
1. VNACs can contain appliances across
+ ­PORT 1
576-733
ADDRESS
MSB
multiple SLCs and across multiple TrueAlert control sources if controlled by the same 4100ES/4100U panel.
2. Each appliance can be in up to 3 custom VNACs in addition to the default VNACs.
3. Appliances are assigned to default VNACs according to device type. Up to 255 VNACs (247 custom and 8 system reserved) can be created per 4100ES/4100U panel with selectable circuit and point types.
4. Up to 64 VNACs (56 custom and 8 system reserved) are available per TrueAlert Addressable control source.
RUI Communications Wiring Reference
Locate branch circuit terminations within 10 ft
Terminal cabinet
(as required)
Channel 1
Channel 2
Channel 3
TrueAlert
Addressable
Controller
TM
TrueAlert Addressable Controller
CAUTION
DISCONNECT
POWER BEFORE
SERVICING
Optional red
appliqué kit
4009-9805
RUI Communications Rules Summary:
1. Recommended limit of 20 TrueAlert Addressable Controllers. (4010ES has a maximum internal and external limit of 20 card addresses.)
2. Can be wired with other RUI devices (LCD Annunciator shown for reference).
3. Wiring distance is up to 2500 ft (762 m) continuous wiring, and up to 10,000 ft
(3048 m) when "T" tapped (Class B only).
4. Minimum wiring is unshielded twisted pair (some applications may require
3 S4009-0003-10 9/2015
shielded twisted pair, consult your Simplex product supplier for details)
(3 m) of TrueAlert Addressable SLC source
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
576-733
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
4603-9101 LCD
Annunciator
SYSTEM IS NORMAL
12:35:15 am MON 22 NOV 99
FIRE
ALARM
PRIORITY 2
SYSTEM
SYSTEM
POWER
DISPLAY TIME
SILENCED
ALARM
ALARM
SUPERVISORY
TROUBLE
ON
ALARM
SUPV
TBL
ALARM
ALARM
SYSTEM
ACK
ACK
ACK
ACK
SILENCE
RESET
RUI Communications
+ -
+ -
PORT 1
PORT 2
4905-9929 TRUEALERT ISOLATOR INST. INSTR. 574-769 REV
RELAY CONTACTS
MODULE
576-733
3 AMP, 30 VDC
15 mA MAX 24 VDC
ADDRESS
ON
Simplex Time Recorder Co.
MSB
Gardner, MA 01441
4100ES (shown) or 4100U,
4010ES, 4100, 4120, or 4020
Fire Alarm Control Panel