Simplex 4100 Plus Operating Instructions Manual

Page 1
574-026Rev. A
All specifications and other information shown were current as of publication, and are subject to change without notice.
4100+ OPERATING INSTRUCTIONS FOR FIREFIGHTER’S AUDIO SYSTEM
HOW TO OPERATE MIKE
HOW TO OPERATE MICROPHONE
1. To make an announcement with mike:
TO ALL AREAS: Flip up ALL SPEAKERS TALK switch. TO SPECIFIC AREAS: Flip up all desired Speaker Select
Switches. TO AREA IN ALARM: Go to step 2.
2. Remove mike from enclosure and press Mike Talk Switch.
• Turns off any active tone or message.
3. Wait for Talk LED to go on.
4. Make appropriate announcement.
RED FIRE ALARM LED
FIRE ALARM ACKNOWLEDGE KEY
• Releasing Mike Talk Switch restarts tone or message if alarm exists.
5. When finished, flip down ALL SPEAKERS TALK switch and all activated Speaker Select Switches. Then replace the mike.
MIKE TALK SWITCH
HOW TO INITIATE AN EVACUATION SIGNAL
1. TO EVACUATE ALL AREAS: Flip up ALL SPEAKERS EVAC switch. TO EVACUATE SPECIFIC AREAS: Flip up all desired Speaker Select Switches; then flip up SELECTIVE EVAC switch.
2. To make an announcement over mike, see HOW TO OPERATE MICROPHONE instructions shown above.
SPEAKERS
SELECTIVE
SPEAKERS
3. When finished, flip down ALL SPEAKERS EVAC switch.
HOW TO SILENCE FIRE ALARM SIGNALS
CAUTION
Pressing ALARM SILENCE key silences evacuation tone/ message and lights the ALARM SILENCED LED.
1. To silence alarm evacuation signals, press Main Panel’s ALARM SILENCE key.
SPEAKER
SPEAKER
HOW TO USE LOCAL SPEAKER SWITCH
(Plays active tone/message on panel speaker)
1. Flip up LOCAL SPEAKER switch.
2. When finished, flip down LOCAL SPEAKER switch.
OPERATION SELECT
SWITCHES
NOTE:
IF YOUR SYSTEM SWITCH CONFIGURATION DOES NOT MATCH THIS SHEET, CONSULT SIMPLEX FOR SPECIFIC OPERATIONS. SIMPLEX IS LISTED IN THE YELLOW PAGES.
MOUNTED ADJACENT TO THE CONTROL PANEL FOR READY REFERENCE
THESE INSTRUCTIONS ARE INTENDED TO BE FRAMED AND
See Operator’s Instruction Manual for detailed operation
© 1997 Simplex Time Recorder Co., Gardner, MA01441-0001 U.S.A.
Technical Manuals Online! - http://www.tech-man.com
Actions taken during a fire depend upon local practices.
TALK LED
ALL
EVAC
EVAC
ALL
TALK
LOCAL
ALERT
LOCAL
EVAC
ON =UP NORMAL=CENTER OFF=DOWN
(SINGLE CHANNEL AUDIO)
YOUR SAFETY AND THE SAFETY OF
THOSE AROUND YOU ALWAYS COMES FIRST!
Be sure you know what to do.
FIRE ALARM SILENCED
4100+ MAIN CONTROL PANEL
FLR 1
FLR 2
FLR 3
FLR 4
FLR 5
FLR 6
FLR 7
FLR 8
SPEAKER SELECT
SWITCHES
(SPEAKER SELECT SWITCH OPERATION)
PHONE PIEZO
SILENCE
PHONE
1
CIRCUIT
PHONE
2
CIRCUIT
PHONE
3
CIRCUIT
PHONE
4
CIRCUIT
PHONE
5
CIRCUIT
PHONE
6
CIRCUIT
PHONE
7
CIRCUIT
PHONE SELECT
SWITCHES
LED
FIRE ALARM SILENCE KEY
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE SELECT
SWITCHES
HOW TO OPERATE PHONE
PHONE OPERATION
1. When remote phone is plugged in or remote handset is lifted:
• Ring signal is heard on handset.
• Phone LED flashes at panel.
• Tone sounds at panel.
2. Pick up master phone.
3. To connect phone, flip up Phone Select Switch next to flashing LED.
• Handset ring signal goes off.
• Flashing LED turns on steady.
• Panel tone is turned off.
4. Use master phone as required.
5. Repeat steps 3 and 4 if another remote handset is lifted or phone is plugged in. To silence the tone without connecting the remote phone, flip up PHONE PIEZO SILENCE switch.
6. When finished, hang up master phone and flip down
8
Phone Select Switches.
• Remote phone must be unplugged or remote handset
9
replaced. (If remote phone is off hook more than 10 sec­ond, panel tone re-sounds and LED flashes.)
10
11
HOW TO RESET THE SYSTEM
1. When the alarm condition has been cleared, restore or replace all affected devices in accordance with the instructions provided with each device (smoke detector,
12
motion sensor, etc.).
2. Reset the system.
13
FIRE ALARM Condition: Press the <SYSTEM RESET>
key.
14
15
Interface Panel access door and press the <PRIORITY 2 ALARM RESET> key on the programmable CON­TROL Key Panel. (The CONTROL Key Panel is located on the far left of the Operator Interface Panel.)
After a short delay, the system will return to normal and dis­play the following message.
SYSTEM IS NORMAL
9:27:40SAT 27 SEP 97
IN CASE OF TROUBLE, NOTIFY:
NAME:
TITLE:
ADDRESS:
PHONE NO.:
Page 2
574-026Rev. A
All specifications and other information shown were current as of publication, and are subject to change without notice.
4100+ OPERATING INSTRUCTIONS FOR FIREFIGHTER’S AUDIO SYSTEM
HOW TO OPERATE MIKE
HOW TO OPERATE MICROPHONE
1. To make an announcement with mike:
TO ALL AREAS: Flip up ALL SPEAKERS TALK switch. TO SPECIFIC AREAS: Flip down all desired Speaker
Select Switches.
RED FIRE ALARM LED
2. Remove mike from enclosure.
3. Press Mike Talk Switch.
• Wait for Talk LED to go on.
4. Make appropriate announcement; then release Mike Talk
FIRE ALARM ACKNOWLEDGE KEY
Switch.
5. When finished, flip down ALL SPEAKERS TALK switch and flip to center position all activated Speaker Select Switches. Then replace the mike.
MIKE TALK SWITCH
HOW TO INITIATE AN EVACUATION SIGNAL
1. TO EVACUATE ALL AREAS: Flip up ALL SPEAKERS EVAC switch. TO EVACUATE SPECIFIC AREAS: Flip up all desired Speaker Select Switches; then flip up SELECTIVE EVAC switch.
2. To make an announcement over mike, see HOW TO OPERATE MICROPHONE instructions shown above.
3. When finished, flip down ALL SPEAKERS EVAC switch and flip to center position all activated Speaker Select Switches. Then replace mike.
SPEAKERS
SELECTIVE
SPEAKERS
HOW TO SILENCE FIRE ALARM SIGNALS
CAUTION
Pressing ALARM SILENCE key silences evacuation tone/ message and lights the ALARM SILENCED LED.
1. To silence alarm evacuation signals, press Main Panel’s ALARM SILENCE key.
HOW TO USE LOCAL SPEAKER ALERT SWITCH
(Plays active tone/message on panel speaker)
1. Flip up LOCAL SPEAKER ALERT switch.
2. When finished, flip down LOCAL SPEAKER ALERT switch.
HOW TO USE LOCAL SPEAKER EVAC SWITCH
(Primary audio channel to panel speaker)
1. Flip up LOCAL SPEAKER EVAC switch.
2. When finished, flip down LOCAL SPEAKER EVAC switch.
NOTE:
IF YOUR SYSTEM SWITCH CONFIGURATION DOES NOT MATCH THIS SHEET, CONSULT SIMPLEX FOR SPECIFIC OPERATIONS. SIMPLEX IS LISTED IN THE YELLOW PAGES.
MOUNTED ADJACENT TO THE CONTROL PANEL FOR READY REFERENCE
SPEAKER
SPEAKER
OPERATION SELECT
SWITCHES
THESE INSTRUCTIONS ARE INTENDED TO BE FRAMED AND
See Operator’s Instruction Manual for detailed operation
© 1997 Simplex Time Recorder Co., Gardner, MA01441-0001 U.S.A.
Technical Manuals Online! - http://www.tech-man.com
Actions taken during a fire depend upon local practices.
TALK LED
ALL
EVAC
EVAC
ALL
TALK
LOCAL
ALERT
LOCAL
EVAC
UP =ON/EVAC DOWN=ON/TALK/ALERT CENTER=OFF/AUTO
(DUAL CHANNEL AUDIO)
YOUR SAFETY AND THE SAFETY OF
THOSE AROUND YOU ALWAYS COMES FIRST!
Be sure you know what to do.
FIRE ALARM SILENCED
4100+ MAIN CONTROL PANEL
FLR 1
FLR 2
FLR 3
FLR 4
FLR 5
FLR 6
FLR 7
FLR 8
SPEAKER SELECT
SWITCHES
(SPEAKER SELECT SWITCH OPERATION)
PHONE PIEZO
SILENCE
PHONE
1
CIRCUIT
PHONE
2
CIRCUIT
PHONE
3
CIRCUIT
PHONE
4
CIRCUIT
PHONE
5
CIRCUIT
PHONE
6
CIRCUIT
PHONE
7
CIRCUIT
PHONE SELECT
SWITCHES
LED
FIRE ALARM SILENCE KEY
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE
CIRCUIT
PHONE SELECT
SWITCHES
HOW TO OPERATE PHONE
PHONE OPERATION
1. When remote phone is plugged in or remote handset is lifted:
• Ring signal is heard on handset.
• Phone LED flashes at panel.
• Tone sounds at panel.
2. Pick up master phone.
3. To connect phone, flip up Phone Select Switch next to flashing LED.
• Handset ring signal goes off.
• Flashing LED turns on steady.
• Panel tone is turned off.
4. Use master phone as required.
5. Repeat steps 3 and 4 if another remote handset is lifted or phone is plugged in. To silence the tone without connecting the remote phone,
8
flip up PHONE PIEZO SILENCE switch.
6. When finished, hang up master phone and flip down
9
Phone Select Switches.
• Remote phone must be unplugged or remote handset
10
replaced. (If remote phone is off hook more than 10 sec­onds, panel tone re-sounds and LED flashes.)
11
HOW TO RESET THE SYSTEM
12
13
14
15
1. When the alarm condition has been cleared, restore or replace all affected devices in accordance with the instructions provided with each device (smoke detector, motion sensor, etc.).
2. Reset the system.
FIRE ALARM Condition: Press the <SYSTEM RESET>
key.
Interface Panel access door and press the <PRIORITY 2 ALARM RESET> key on the programmable CON­TROL Key Panel. (The CONTROL Key Panel is located on the far left of the Operator Interface Panel.)
After a short delay, the system will return to normal and dis­play the following message.
SYSTEM IS NORMAL
9:27:40SAT 27 SEP 97
IN CASE OF TROUBLE, NOTIFY:
NAME:
TITLE:
ADDRESS:
PHONE NO.:
Loading...