1.0 Method of Operation __________________________________4
1.1 General Information ______________________________________ 4
1.2 Opening and Locking _____________________________________ 4
2.0 Special Models _______________________________________4
2.1 PLUS Version ___________________________________________ 4
3.0 Additional Functions __________________________________5
3.1 OMRON ________________________________________________ 5
3.2 Extending the Coupling Time ______________________________ 5
3.3 Logging Unauthorized Access Attempts _____________________ 5
3.4 No Acoustic Programmer Acknowledge _____________________ 5
4.0 Battery Warnings _____________________________________5
4.1 Half Cylinder ____________________________________________ 5
4.2 Transponder ____________________________________________ 6
5.0 Battery Replacement __________________________________6
![](/html/05/0524/05244b985094bd3f6e323704b0eda27b225ba6c65fd53a444f16065759dcfba1/bg3.png)
Digital Half Cylinder 3061
Content
6.0 Installation Instructions________________________________7
6.1 General Information ______________________________________ 7
6.2 Programming a Half Cylinder ______________________________ 7
6.3 Installing in Doors _______________________________________ 7
6.4 Installation Behind Blanks for Half Cylinders With 3 Setscrews __ 8
(New Flange Mounting)_________________________________________ 8
6.4.1 Removal of the Knob and Flange of the Half Cylinder __________ 8
6.4.2 Installing the Knob and Flange of the Half Cylinder ____________ 9
6.5 Installation Behind Blanks for Half Cylinders With 2 Setscrews __ 9
(Old Flange Mounting) _________________________________________ 9
6.5.1 Removal of the Knob and Flange of the Half Cylinder _________ 10
6.5.2 Installing the Knob and Flange of the Half Cylinder ___________ 10
6.6 Perform Function Test ___________________________________ 11
7.0 Data Sheet__________________________________________ 12
![](/html/05/0524/05244b985094bd3f6e323704b0eda27b225ba6c65fd53a444f16065759dcfba1/bg4.png)
Digital Half Cylinder
Page 4
1.0 Method of Operation
1.0 General Information
The outer dimensions of the Digital Half Cylinder exactly match those of a mechanical
cylinder complying with DIN 18252. Please ask for approved self-locking and antipanic locks at the manufacturer.
1.1 Opening and Locking
When not activated, the outer knob turns freely. It is not possible to open the door or
to lock it. Hold the transponder at a distance of approximately 10 to 40 cm (4 to 16
inches) from the digital half cylinder and briefly press the transponder button once. If
this is an authorised transponder, a double signal tone sounds and the cylinder couples. Now turn the outer knob in the locking or opening direction. You have approximately five seconds for this process. Then a single signal tone sounds and the outer
knob turns freely again. Make sure that the outer knob of the half cylinder turns freely
again after the coupling process.
& If this is a transponder that is not authorised at this time because of the time
zone plan, a single signal tone sounds. The cylinder does not couple, however, and you cannot open the door.
2.0 Special Models
The Digital Half Cylinder 3061 is also available in the following optional versions:
2.0 PLUS Version
Design is similar to the standard version but with access logging and time zone
control.
Access logging The locking cylinder stores the last 128 accesses with date,
Time zone control You can program locking cylinders in such a way that
time and the user name of the transponder. You can read out
the data with the PalmCD2 or over the network.
authorised transponders are authorised for access only at
certain times.