SimonsVoss 3061 MR, 3061, 3061 MS, 3061 HZ, 3061 SKG User Manual

...
Digital Locking Cylinder 3061
Manual
16.12.2019

Contents

Digital Locking Cylinder 3061 (Manual)
2 / 54
Contents
1 Intended use ................................................................................................................................................ 5
2 General safety instructions.....................................................................................................................6
3 Product specific safety notices ........................................................................................................... 10
4.1 Product description....................................................................................................................................... 14
4.2 Locking cylinder design ............................................................................................................................... 15
4.3 Half cylinder design....................................................................................................................................... 15
4.4 Opening and locking from the outside ................................................................................................ 16
4.5 Opening and locking from the inner side............................................................................................ 16
5 Versions ....................................................................................................................................................... 17
5.1 FD version (Standard)................................................................................................................................. 18
5.2 HZ version (Standard) ................................................................................................................................ 18
5.3 Half-cylinder (HZ) version (self-locking)........................................................................................... 18
5.4 ZK version .......................................................................................................................................................... 18
5.5 version for steel and fire retardant doors........................................................................................... 19
5.6 TS version .......................................................................................................................................................... 19
5.7 MR option........................................................................................................................................................... 19
5.8 MS version .........................................................................................................................................................19
5.9 SKG or VdS versions (SZ).......................................................................................................................... 19
5.10 AP version ......................................................................................................................................................... 20
5.11 AP2 Version........................................................................................................................................................21
5.12 CO version..........................................................................................................................................................22
5.13 WP Version (FD) ............................................................................................................................................22
5.14 WP version (HZ/CO/AP) ...........................................................................................................................22
5.15 SW version (CO) ............................................................................................................................................22
5.16 VR version (HZ) ..............................................................................................................................................22
5.17 DK version (HZ) ..............................................................................................................................................22
5.18 WN version (HZ) ............................................................................................................................................23
5.19 DM version .........................................................................................................................................................23
5.20 Hybrid-Version.................................................................................................................................................23
5.21 Extra lengths.....................................................................................................................................................23
5.22 Examples of locking cylinder use ...........................................................................................................23
6 Installation instructions .........................................................................................................................25
Contents
Digital Locking Cylinder 3061 (Manual)
3 / 54
6.1 General instructions......................................................................................................................................25
6.2 Programming the locking cylinder.........................................................................................................25
6.3 Installation variants ......................................................................................................................................25
6.3.1 Installation of double thumb-turn cylinders (except types .AP/.SKG/.VdS) ......
25
6.3.2 Fitting an anti-panic cylinder .................................................................................................. 27
6.3.3 Installation of SKG/VdS cylinders ...................................................................................... 30
6.3.4 Half Cylinder DK/MR.................................................................................................................... 31
6.3.5 Installing Swiss Round...............................................................................................................33
7 Audible signals ......................................................................................................................................... 34
7.1 Battery warnings ........................................................................................................................................... 34
7.2 Battery warning for transponders..........................................................................................................37
8 System 3060 battery replacement .................................................................................................. 38
8.1 General instructions..................................................................................................................................... 38
8.2 Battery life ........................................................................................................................................................ 38
8.3 Emergency battery procedure................................................................................................................ 39
8.3.1 Storage mode (G1)..................................................................................................................... 39
8.3.2 Freeze mode (G2)....................................................................................................................... 39
8.4 Procedure .........................................................................................................................................................40
8.5 Procedure for outer thumb turn (MH cylinder) ............................................................................... 41
9 Maintenance, cleaning and disinfection.......................................................................................... 43
10 Areas of use .............................................................................................................................................. 44
10.1 General............................................................................................................................................................... 44
10.2 Fire doors........................................................................................................................................................... 44
10.3 Doors along rescue routes........................................................................................................................ 44
10.4 Installation outdoors ................................................................................................................................... 44
11 Accessories ............................................................................................................................................... 45
11.1 Thumb-turns................................................................................................................................................... 45
11.2 Core extraction protection adapter (Z4.KA.SET)......................................................................... 45
11.3 Core extraction protection extension for SKG/VdS cylinders (Z4.KA.SET2) .................45
11.4 Core extraction protection extension for SKG/VdS cylinders (Z4.KA.SET2.IT) ............ 45
11.5 Tool ...................................................................................................................................................................... 46
11.6 Battery set ........................................................................................................................................................46
12 Technical data ..........................................................................................................................................47
12.1 Locking cylinder ..............................................................................................................................................47
12.2 Half cylinder .....................................................................................................................................................49
Contents
Digital Locking Cylinder 3061 (Manual)
4 / 54
13 Declaration of conformity ......................................................................................................................51
14 Help and other information ..................................................................................................................52
Digital Locking Cylinder 3061
1. Intended use
(Manual)
5 / 54

1 Intended use

Digital SimonsVoss Locking Cylinder 3061 are installed in designated door locks, such as DIN mortise locks, to integrate them into a digital locking system.
The digital Locking Cylinder 3061 may only be used for its intended purpose in a designated door locking device. No other use is permitted.
Digital Locking Cylinder 3061s are available in various lengths. The selection of the proper size is of significance. The length of the locking cylinder is printed on the packaging and can be measured at any time. If the cylinder is too short, the handles cannot be fitted. If the cylinder is too long, it may be ripped out of the locking device. The may not protrude more than 3 mm on each side of the door to ensure proper operation.
The product may not be changed in any way, other than in compliance with the changes described in the instructions.
Digital Locking Cylinder 3061
2. General safety instructions
(Manual)

2 General safety instructions

Signal word (ANSI Z535.6)
DANGER Death or serious injury (likely)
WARNING
CAUTION Minor injury
IMPORTANT Property damage or malfunction
NOTE Low or none
WARNING
Blocked access
Possible immediate effects of non­compliance
Death or serious injury (possible, but unlikely)
6 / 54
Access through a door may stay blocked due to incorrectly fitted and/or in­correctly programmed components. SimonsVoss Technologies GmbH not liable for the consequences of blocked access such as access to in­jured or endangered persons, material damage or other damage!
WARNING
Blocked access through manipulation of the product
If you change the product on your own, malfunctions can occur and access through a door can be blocked.
Modify the product only when needed and only in the manner described
in the documentation.
CAUTION
Fire hazard posed by batteries
The batteries used may pose a fire or burn hazard if handled incorrectly.
is
1. Do not try to charge, open, heat or burn the batteries.
2. Do not short-circuit the batteries.
Digital Locking Cylinder 3061
2. General safety instructions
(Manual)
7 / 54
IMPORTANT
Damage resulting from electrostatic discharge (ESD)
This product contains electronic components that may be damaged by electrostatic discharges.
1. Use ESD-compliant working materials (e.g. Grounding strap).
2. Ground yourself before carrying out any work that could bring you into contact with the electronics. For this purpose, touch earthed metallic surfaces (e.g. door frames, water pipes or heating valves).
IMPORTANT
Damage resulting from liquids
This product contains electronic components that may be damaged by li­quids of any kind.
Keep liquids away from the electronics.
IMPORTANT
Damage resulting from aggressive cleaning agents
The surface of this product may be damaged as a result of the use of un­suitable cleaning agents.
Only use cleaning agents that are suitable for plastic or metal surfaces.
IMPORTANT
Damage as a result of mechanical impact
This product contains electronic components that may be damaged by mechanical impacts of any kind.
1. Avoid touching the electronics.
2. Avoid other mechanical influences on the electronics.
IMPORTANT
Damage due to polarity reversal
This product contains electronic components that may be damaged by re­verse polarity of the power source.
Do not reverse the polarity of the voltage source (batteries or mains
adapters).
Digital Locking Cylinder 3061
2. General safety instructions
(Manual)
8 / 54
IMPORTANT
Failure of operation due to different discharged batteries
This product uses one or more batteries for power supply. The batteries are discharged at approximately the same rate.
Always replace all batteries at the same time.
IMPORTANT
Operational malfunction due to radio interference
This product may be affected by electromagnetic or magnetic interference.
Do not mount or place the product directly next to devices that could
cause electromagnetic or magnetic interference (switching power supplies!).
IMPORTANT
Communication interference due to metallic surfaces
This product communicates wirelessly. Metallic surfaces can greatly re­duce the range of the product.
Do not mount or place the product on or near metallic surfaces.
NOTE
Intended use
SimonsVoss-products are designed exclusively for opening and closing doors and similar objects.
Do not use SimonsVoss products for any other purposes.
NOTE
Battery contact malfunction due to grease film
When touching batteries, leave a thin film of skin grease on the batteries. This film deteriorates the contact between the electronics and the batter­ies.
1. Do not touch the contacts of the new batteries with your hands.
2. Use clean and grease-free gloves.
Digital Locking Cylinder 3061
2. General safety instructions
(Manual)
9 / 54
NOTE
Dispose of the batteries as per local and country-specific regulations.
NOTE
Function error due to poor battery contact
If the contact surface to the battery is too small, then the battery connec­tion may not create a stable connection to the battery.
Only use batteries that are approved by SimonsVoss.
NOTE
Qualifications required
The installation and commissioning requires specialized knowledge.
Only trained personnel may install and commission the product.
NOTE
Modifications or further technical developments cannot be excluded and may be implemented without notice.
NOTE
The German language version is the original instruction manual. Other lan­guages (drafting in the contract language) are translations of the original instructions.
NOTE
Read and follow all installation, installation, and commissioning instruc­tions. Pass these instructions and any maintenance instructions to the user.
Digital Locking Cylinder 3061
3. Product specific safety notices
(Manual)
10 / 54

3 Product specific safety notices

WARNING
Fault in escape door function due to unsuitable closing cylinder or un­suitable environment
The use of unsuitable closing cylinders or components that are not opera­tional can adversely affect the function of an escape door. If you use the anti-panic cylinder in locks that are not approved, the escape door function can be disrupted and not released again. Contact SimonsVoss Technolo­gies GmbHfor further information.
1. Ensure that all parts of the lock are operational.
2. Check that the panic function of the mortice lock is ensured.
3. Only use the anti-panic cylinder in locks that are expressly approved for the anti-panic cylinder. See also the manufacturer's documentation in this respect.
4. Do not use the anti-panic cylinder in temperatures below -20 °C or above +50 °C.
5. Carry out a function test of the anti-panic cylinder after installation or after a battery change.
CAUTION
Use of the anti-panic version of the locking cylinder in non-approved locks
If you use the anti-panic version of the locking cylinder in unauthorised locks, the escape door function may be impaired and cannot be released again.
1. Only use the anti-panic version of the locking cylinder in locks for which the locking cylinder is expressly approved.
2. Please refer to the documentation of the respective lock manufacturer.
3. Contact SimonsVoss Technologies GmbH for further information on this subject (see
Help and other information [}52]
).
Digital Locking Cylinder 3061
3. Product specific safety notices
(Manual)
11 / 54
CAUTION
Hand injuries from carrier springing back
A spring-loaded carrier is used in the anti-panic construction of the closing cylinder. This carrier can spring back when it is not installed, causing hand injuries.
Do not hold the anti-panic construction of the closing cylinders in the
area of the carrier.
IMPORTANT
Damage caused by moisture in outdoor use
Moisture can damage the electronics.
1. If you want to use the locking cylinder for outdoor applications or in high humidity (bathrooms or washrooms), use the WP version.
2. Carefully insert the locking cylinder to avoid damaging the O-rings.
IMPORTANT
Mechanical damage to the thumb-turn as a result of obstacles
If the thumb-turn can knock against the wall or other objects as a result of the installation situation, it may become damaged.
In such situations, use a suitable door stop.
IMPORTANT
Mechanical damage to the knob through misuse as door-opener
Some doors are very heavy and solidly constructed. The knob is not suit­able for opening such doors.
1. Don't pull the knob to open doors.
2. Make suitable door openers available (suitable handles) to avoid misuse of the knob.
Digital Locking Cylinder 3061
3. Product specific safety notices
(Manual)
12 / 54
NOTE
Service interval of not less than one month for emergency exit locks
The European standard EN 179 (attachment C) specifies that emergency exit locks must be serviced monthly. The anti-panic function must be in a satisfactory and operational condition.
Ensure during a monthly service that fault-free and operational
condition of the anti-panic construction of the closing cylinder is guaranteed.
NOTE
Qualifications required
The installation and commissioning requires specialized knowledge.
Only trained personnel may install and commission the product.
NOTE
Inclusion of persons without means of identification
The freely-rotating construction of the closing cylinder can only be opened with a means of identification from both sides.
Ensure that no persons without means of identification are in the
secured area.
NOTE
Length of locking system password
For security reasons, the locking system password must consist of at least 8 characters. The code length for digital closing cylinders
3060/3061 and MobileKey)
corresponds to 2
168
Bit.
(and for System
NOTE
Fault in the interior knob due to moisture
The inner knob of the closing cylinder is of protection class IP40 and is thus not protected from moisture.
Ensure that the interior knob cannot come into contact with water.
Digital Locking Cylinder 3061
3. Product specific safety notices
(Manual)
13 / 54
NOTE
Battery changes may only be carried out by trained personnel and only with the battery key provided (Z4.KEY)!
NOTE
Programming with obsolete LSM version
New components can only be programmed with the current version of LSM.
NOTE
Difficulty of operation of the lock due to stiff latch or bolt
If the latch or bolt of the mortice lock are stiff, the closing cylinder will also be stiff.
Check that the latch or the bolt of the mortice lock are free-moving.
NOTE
Fitting error or incorrect order
If you make a mistake in measuring the door and order a closing cylinder, the closing cylinder will not fit.
Check the dimensions of the door again before ordering.
Digital Locking Cylinder 3061
4. General
(Manual)
14 / 54

4 General

4.1 Product description

The SimonsVoss Digital Locking System 3060 is an electronic version of a mechanical locking system with the functions of a typical access control system.
Digital Locking Cylinder 3061 and the digital half cylinder are a main component in the locking and access control system, where radio communication replaces the mechanical authentication of a conventional key.
This product description details both the locking cylinder and the half cylinder. The design and operating mode of the two products are comparable in many respects. Any differences between the two products and different versions are pointed out in the corresponding sections.
'Locking cylinder' is taken to mean both 'locking cylinder' and 'half cylinder' in this document unless explicitly stated otherwise or taken out of context.
Data are transmitted for authentication using a transponder (25kHz inductive) or a smart card featuring the RFID standard MIFARE MIFARE
Refer to the respective manuals for details about smart card products (SC). This description mentions the smart card cylinder, but does not describe it in any detail.
The locking cylinder is supplied in different versions and meets different profile standards, such as DIN 18252/EN1303, so that almost any lock anywhere in the world can be retrofitted with this cylinder. Digital Locking Cylinder 3061 has much to offer – greater security, greater flexibility, lower costs, network-ready without any wiring on the door or frame and less time and effort required for installation.
Digital Locking Cylinder 3061 is powered by two batteries in a redundant system. Cylinders operate as stand-alone components thanks to this integrated power supply, which also means there is no need to wire doors. An intelligent battery warning system also increases reliability.
©
DESFire.
©
Classic or
The SimonsVoss system elements are not configured before delivery from the factory. They are first assigned to a locking system during initial programming. This makes it easier for stock keeping and makes product management simpler.
Thanks to modularity, all locking cylinders are seamlessly integrated into the SimonsVoss System 3060 and, like all SimonsVoss components, they can be programmed using the locking plan software. Other authentication components, such as Pin Code Keypad 3068, Biometric Reader Q3008 or
Digital Locking Cylinder 3061
4. General
(Manual)
15 / 54
Compact Reader 3078, can be connected as a wireless element. If the system is extended at a later stage, cylinders can be networked without wiring and managed in an online interconnected system.
The locking cylinders are provided with two different firmware generations – G1 and G2. G2 features a more efficient communication protocol than G1. It will allow you to create larger, more efficient locking systems. Authorisations are written both on the locking cylinder and the transponder, thus delivering greater flexibility for programming. A G2 system can also form a virtual network, i.e. authorisations and blocking lists are written on the transponder and transmitted into the locking system. Refer to the G2 manual for more details.

4.2 Locking cylinder design

1. Inside thumb-turn
2. Batteries/electronics
3. Actuator
4. Drilling protection
5. Outer thumb-turn

4.3 Half cylinder design

1. Actuator
2. Electronics
3. Batteries
4. Thumb-turn
Digital Locking Cylinder 3061
4. General
(Manual)

4.4 Opening and locking from the outside

With freely rotating locking cylinders (FD)
The outer and inside thumb-turn rotate freely when not activated in the freely rotating Locking Cylinder 3061 lock the door without a valid ID medium. Identify yourself with your valid ID medium on the outer thumb-turn to activate the cylinder. If the ID medium is authorised, an audible signal will sound twice, the blue LED will flash twice and the locking cylinder will engage ready to open. Turn the outer thumb-turn in the direction of locking or opening. You have about five seconds to do so. The engage time can be configured. A single audible signal will then sound and the outer or inside thumb-turn will rotate freely again. Ensure that the outside or inside locking cylinder thumb-turn rotates freely again after the thumb-turn has been engaged ready for use.
, meaning it is not possible to open or
16 / 54
NOTE
If the user has an ID medium which is not authorised for use at that particu­lar moment due to the time zone plan, a single audible signal will sound. The cylinder will not engage, so the outer or inside thumb-turn continues to rotate freely and the user cannot open the door. You need to configure this response separately in third-party systems.

4.5 Opening and locking from the inner side

With freely rotating locking cylinders (FD)
The outer and inside thumb-turn rotate freely when not activated in the freely rotating Locking Cylinder 3061 locked on the outside using an ID medium on the inside thumb-turn.
With non-freely rotating locking cylinders (CO)
Locking Cylinder 3061s which are permanently engaged for use can be operated from the inside without a ID medium. In this case, the door can be opened and closed using the inside thumb-turn without an authorised ID medium.
, Doors can also only be opened or
Digital Locking Cylinder 3061
5. Versions
(Manual)

5 Versions

Different versions of the digital Locking Cylinder 3061 are offered to cover the different needs of the market. The different versions are indicated by a code. The different versions can be combined:
ABBREVIATION DESIGNATION
FD
HZ Half cylinder X
Access control Access Control X X
FH
TS Button control X
Standard (freely rotating)
Fire-retardant version
LOCKING CYLIN­DER
X
X
HALF CYLINDER
17 / 54
MR Multi-point X X
MS Brass version X X
Class AZ VdS cyl-
SKG
VDS
AP
CO Comfort cylinder X
WP Waterproof - WP X X
SW Seawater-proof X
WN
inder (basic pro­tection against picking)
Class BZ VdS cyl­inder (medium protection against picking)
Anti-panic func­tion
Network integ­rated
X
X
X
X X
SC
VR Shortened range X
DK Detachable knob X
DM Door Monitoring X
Refer to the current product catalogue to see which particular versions can be combined with one another. Locking cylinders are also supplied in different profiles to satisfy differences in different regions:
PROFILE LOCKING CYLINDER HALF CYLINDER
SmartCard ver­sion
X
Digital Locking Cylinder 3061
5. Versions
(Manual)
Standard Euro profile cylinder as per DIN 18252/EN1303
Scandinavian Oval X
British oval X
Swiss Round X X
Locking Cylinder 3061s are also offered in mortise and rim cylinder models for American door profiles.
X X

5.1 FD version (Standard)

Locking Cylinder 3061 freely rotating on both sides.
The .FD double thumb-turn cylinder is available from a length of 30-30 mm.
18 / 54

5.2 HZ version (Standard)

The standard version of the half cylinder.

5.3 Half-cylinder (HZ) version (self-locking)

Variant of the half cylinder with self-locking by a spring-loaded cam with fixed reset position. Due to the suspension and the chamfer on the cam, locking without ID medium is possible by means of pressing. The main application is e.g. the installation in swivel lever handles for switch and distribution cabinets or server racks in computer centres.

5.4 ZK version

Design is similar to standard version but with access logging and time zone control.
Access event logging
The locking cylinder logs up to 3,072 of the most recent access events with the date, time and transponder ID (TID). The data can be read via the network using the programming device.
Time zone control
TLocking Cylinder 3061 can be programmed in such a way that authorized transponders are only authorized for access at specific times. For G1, there are 5 (+1) time zone groups available per area (e.g. outer perimeter) within the different time zone schedules while G2 has 100 (+1) such groups.
Digital Locking Cylinder 3061
5. Versions
(Manual)
19 / 54

5.5 version for steel and fire retardant doors

Design is similar to standard version but for doors with sturdy metal sections, such as fire doors, or doors with highly protective shielding. This version is recommended in areas with high interference fields, such as server rooms, and for all metal doors. The FH version cannot be retrofitted.
If wired networks are used, we recommend using this cylinder version due to its reduced projection.
Before a locking cylinder is installed into a fire/smoke retardant door, the fire certification has to be checked first to ensure that conformity is in place.
It must be ensured that any locking devices or sealing strips do not impede the orderly operation of the MC.

5.6 TS version

Design as for standard version, but with the additional option of allowing the cylinder to engage without an identification medium. This cylinder version can be engaged mechanically with the aid of two buttons on the inside thumb-turn. This means that no transponder is needed when the user is on the internal. The cylinder will then engage for five seconds (configurable) and the door can be opened or locked. Once this time interval expires, the cylinder rotates freely again on both sides.
The .TS version cannot be retrofit.

5.7 MR option

Design is similar to standard version but the locking cam features fixed points where it positions itself when disengaged. This version is particularly suitable for very smooth-running locks with multi-point locking systems.
Please observe the lock manufacturer's declaration of conformity when combining multi-point locks with a panic function.

5.8 MS version

The Locking Cylinder 3061 can be supplied with stainless steel or brass colour finish (highly glossy thumb-turn covers).

5.9 SKG or VdS versions (SZ)

The Locking Cylinder 3061 is optionally also available as a VdS cylinder. The additional mechanical security features ensure that VdS Classes AZ and BZ or Class SKG*** are achieved. These versions cannot be combined with the brass and WP versions. The VdS cylinder can only be supplied in combination with access control (ZK) functions.
Digital Locking Cylinder 3061
5. Versions
(Manual)
20 / 54
NOTE
The profile cylinder must be protected with a VdS-approved burglar-resist­ant class B or C door label. Such door plates conform to DIN 18257, Class ES 2 or ES 3. The cylinder may not protrude more than 3 mm above the door plate. The scope of burglary-resistant measures is based on the re­spective national provisions.
This version is available as .MS, .FH and WN versions.

5.10 AP version

A cylinder with an anti-panic function must be fitted to all doors where the lock's panic function may be adversely affected by the position of the cam. This version contains an integrated spring mechanism which places the locking cam in a non-critical position, meaning a panic lock's panic function cannot be blocked.
In contrast to all other cylinders, the .AP type cylinder is fitted the other way round with the thumb-turn containing the battery and the electronics module installed on the outside (see diagram).
Unlike the standard anti-panic cylinder (AP), the inside thumb-turn of which is permanently engaged, the inside thumb-turn for the freely­rotating AP version (AP.FD) is disengaged mechanically and cannot be engaged with an identification medium.
1. Inside thumb-turn
2. Recessed grip ring
3. Battery replacement key
4. Outside thumb-turn
The following aspects should be taken into consideration for doors along rescue routes which have been installed after April 1, 2003 (exit devices as per DIN EN 179 or DIN EN 1125): All Locking Cylinder 3061 used for all exit devices where their approval states that the Locking
models may be
Digital Locking Cylinder 3061
5. Versions
(Manual)
Cylinder 3061 has no impact on the lock's function. The Locking Cylinder 3061 type .AP (anti-panic cylinder) must be used for all exit devices where the Locking Cylinder 3061 must be stated in the lock manufacturer's approval.
DANGER
Due to the structural design of panic locks, it is not permitted to turn the Locking Cylinder 3061 locked since this may affect the lock's panic function.
cam position affects the lock's function. This
thumb-turn to the stop position when the door is

5.11 AP2 Version

A cylinder with an anti-panic function must be fitted to all doors where the locking device's panic function may be adversely affected by the position of the cam. This version contains an integrated spring mechanism which places the locking cam in a non-critical position, meaning a panic locking device's panic function cannot be blocked.
21 / 54
Installation is the same as with the regular Locking Cylinder 3061.
The following aspects should be taken into consideration for doors along rescue routes which have been installed after April 1, 2003 (exit devices as per DIN EN 179 or DIN EN 1125): All Locking Cylinder 3061 all closures whose approval states that the Locking Cylinder 3061 effect on the function of the lock. The Locking Cylinder 3061 (anti-panic cylinder) must be used where necessary for all locks in which the position of the Locking Cylinder 3061 of the lock; this must be specified in the approval of the lock manufacturer.
DANGER
Due to the structural design of panic locks, it is not permitted to turn the thumb-turn of the Locking Cylinder 3061 is locked since this may affect the lock's panic function.
IMPORTANT
cam has an effect on the function
to the stop position when the door
s may be used with
has no
type AP2
Loss of magnetization and cylinder authorization
If you use flip-flop mode or time switching on an AP2 cylinder, magnetiza­tion may be lost and the cylinder must be reauthorized. SimonsVoss there­fore generally recommends not using these functions with an AP2 cylinder.
Digital Locking Cylinder 3061
5. Versions
(Manual)

5.12 CO version

In the comfort cylinder (CO), the inside knob is permanently interconnected with the locking cam, so that doors can be opened and locked from the inside without needing to use a transponder.

5.13 WP Version (FD)

The protection rating is increased from IP54 to IP66 in the WP version (weatherproof) of the Locking Cylinder 3061 for use outdoors or on external doors even if the cylinder is not exposed to direct splash water.
Anti-panic cylinder: The WP version is specifically designed for outdoor areas and should be fitted if the outer thumb-turn comes into contact with water (e.g. rainwater). The WP version features greater resistance to water, meaning the cam should not come into contact with water.
22 / 54
. This version is thus suitable
This version is available from a length of 30-35 mm and as .FD, .ZK, .MS and .FH models.

5.14 WP version (HZ/CO/AP)

The electronic thumb-turn is sealed in the WP version of the half, comfort and anti-panic cylinders, thus providing an increased protection rating of IP66. This version is thus suitable when the electronics side is outdoors, i.e. the electronic thumb-turn is exposed to rain, for example. Water must not enter through the door.

5.15 SW version (CO)

The SW (seawater) version of the comfort cylinder has been specially developed for use on ships or for direct use on the sea. A special, polished V4A knob and a coated handle component are used on the outside.

5.16 VR version (HZ)

This version features a shortened operating range. It is suitable for use in items such as locker doors and mail box systems when the distance to the next door is less than 40 cm.

5.17 DK version (HZ)

The knob can be detached and is ideal for installation behind cover plates on key switches, for example.
Digital Locking Cylinder 3061
5. Versions
(Manual)
23 / 54

5.18 WN version (HZ)

The WN version is fitted with a network flap (LockNode Inside). This network cap enables the lock to be networked directly (networked connection between lock and the LSM).
This version is available for all models.
The network cover can be fitted to locking cylinder types manufactured after May 2008. This allows such cylinders to be retrofit with a network connection without a great deal of installation work.

5.19 DM version

The DoorMonitoring cylinder allows the Locking Cylinder 3061 to transmit door events to LSM in real time.
NOTE
DM cylinders cannot be used in multi-lock systems with gears (gear locks).

5.20 Hybrid-Version

With the hybrid version of the digital locking cylinder, active identification media (e.g., transponders) and passive identification media (e.g., MIFARE or DESFire cards) can be used.

5.21 Extra lengths

All double knob cylinders are available with an overall length of up to 140 mm or a maximum of 90 mm on one side. Longer lengths can be supplied on request. All half cylinders are available with an overall length of up to 100 mm or a maximum of 90 mm on the outside. Longer lengths can be supplied on request.

5.22 Examples of locking cylinder use

FD (ZK) FH (ZK) TS (ZK) AP (ZK)
Entrance doors Fire doors
Apartment en­trance doors
Office doors
Connecting doors
Self-locking doors
Aluminium doors Office doors Emergency exits*
Apartment en­trance doors
Anti-panic doors*
Digital Locking Cylinder 3061
5. Versions
(Manual)
24 / 54
*Comply with EN 179 and EN 1125 requirements and the lock manufacturer's data sheets.
The different versions can be combined as you wish. Exceptions are indicated in the individual model descriptions.
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
25 / 54

6 Installation instructions

6.1 General instructions

When installing the digital Locking Cylinder 3061, ensure that there are no sources of low-frequency radio interference in the surrounding area.
The profile cylinder housing should be fitted flush in outside areas; it should project a maximum of 3 mm and a profile cylinder escutcheon or security fitting should be installed if necessary. It is also important to ensure that no water is able to penetrate the cylinder via the cam section.
You must not strike the thumb-turns when installing the cylinder.
All thumb-turns are locked into place with a bayonet mount (exception: anti-panic inside knob and SKG/VdS outside knob).
The inner side of the Locking Cylinder 3061 is laser-engraved with (the letters IL for inside length) on the profile cylinder housing; the electronics side is identifiable by the black plastic ring between the thumb-turn and the profile cylinder housing.
Batteries are already installed before delivery.
All the tasks listed in this section can also be carried out using the installation/battery key.

6.2 Programming the locking cylinder

Both the digital Locking Cylinder 3061 and the associated transponder must be programmed before installation. You can find more detailed information in the software operation instructions.

6.3 Installation variants

6.3.1 Installation of double thumb-turn cylinders (except types .AP/.SKG/.VdS)

1. Installation key
2. Side marking
3. Recessed grip ring
4. Inside thumb-turn
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
26 / 54
5. Battery replacement key
6. Locking disc with opening (identical on outside)
7. Outer thumb-turn
6.3.1.1 Removing the outer thumb-turn
Place the installation key on the outer thumb-turn in such a way that its two teeth engage into the outer thumb-turn; if necessary, turn the thumb­turn until both teeth lock into the locking disc.
NOTE
The installation tool must be placed flat on the internal front surface of the thumb-turn to ensure that the tool can lock into the locking disc.
Hold the outer thumb-turn firmly and carefully turn the installation tool about 30° in a clockwise direction (until you hear a click). Remove the thumb-turn.
6.3.1.2 Fastening the digital cylinder into the locking device
Turn the cam until it is vertical and pointing downwards. Insert the digital locking cylinder through the locking device in such a way that the inside thumb-turn (see diagram above) is facing the inner side of the door. Fasten the cylinder into the mortise lock with the fastening screw.
NOTE
You must not strike the thumb-turns when installing the cylinder. Do not al­low the cylinder to come into contact with oil, grease, paint or acids.
6.3.1.3 Fastening the outer thumb-turn
Replace the thumb-turn and turn in an anti-clockwise direction while applying slight pressure until the outer thumb-turn grips into the indents in the flange. Possibly place the thumb-turn in this position by pressing it towards the profile cylinder housing.
NOTE
Turning the bayonet disc when not installed may prevent the thumb-turn from being fastened into position. In such a case, push the disc back into the original 'bayonet disc open' position using the installation tool. (see dia­grams)
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
27 / 54
1. Bayonet disc
2. Thumb-turn
3. Bayonet disc closed
4. Bayonet disc open
Place the installation key on the outer thumb-turn in such a way that its two teeth engage into the outer thumb-turn (if necessary, turn the thumb­turn until both teeth lock into the locking disc). Lock the thumb-turn into position again by rotating it 30° in a clockwise direction.
6.3.1.4 Carry out a functional test
1. Engage cylinder using a valid ID medium and turn the thumb-turn in
both the locking and opening direction with the door open. The thumb­turn must be able to rotate easily when you do so.
2. Close the door and repeat the process. If the locking cylinder should be
stiff, you need to align the door or modify the strike plate.

6.3.2 Fitting an anti-panic cylinder

1. Inside thumb-turn
2. Recessed grip ring
3. Battery replacement key
4. Outside thumb-turn
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
28 / 54
The locking cam is always in a pre-defined position in the AP cylinder when disengaged. This prevents accidental blocking. Unlike other cylinder versions, the AP cylinder is installed the other way round (inserted into the lock from the inside to the outside).
6.3.2.1 Removing the inside thumb-turn
Loosen the inside thumb-turn's threaded pin (see diagram above) using an Allen key. Do not unscrew completely. Hold the cam firmly and then turn the inside thumb-turn anti-clockwise or, in the case of a freely rotating AP cylinder, remove the thumb-turn after loosening the threaded pin.
6.3.2.2 Fastening the digital cylinder into the locking device
Turn the cam until it is vertical and pointing downwards. Insert the digital locking cylinder through the locking device from the outside in such a way that the outer thumb-turn is facing the outer side of the door. Fasten the cylinder into the mortise lock with the fastening screw.
NOTE
You must not strike the thumb-turns when installing the cylinder. Do not al­low the cylinder to come into contact with oil, paint or acids.
6.3.2.3 Fastening the inside thumb-turn
Screw the inside thumb-turn onto the thread until it locks into place as it comes up against the cam. Pull on the inside thumb-turn, or push on the inside thumb-turn of a freely rotating AP cylinder, until it locks into position. Fasten the threaded pin tightly using the Allen key.
6.3.2.4 Functional test
To verify that the AP2 cylinder functions correctly in an anti-panic lock,
you must check that the cam moves easily and that the door opens correctly using the procedure described below.
Carry out the functional test in the direction of escape.
You must carry out a functional test whenever the cylinder or the
fastening screw is repositioned.
You will need an authorised identification medium to carry out the
functional test.
Withdraw the dead bolt before the functional test.
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
29 / 54
U section: No restore force on the cam
R section: Restore force section towards U section
O section:
OG: Top threshold section
UG: Lower threshold section
1: Thumb-turn
2: Cam position (concealed)
1. With the cylinder engaged, first turn the thumb-turn in the direction of
locking as far as the deadbolt throw in the 'R' section.
9 You will feel the restore force. When you release the thumb-turn in
this position, it must turn back to the 'U' section of its own accord.
Top dead point in deadbolt throw - no restore force on the cam
2. Lock the locking device and check the restore force. To do so, turn the
engaged thumb-turn in the direction of locking through the 'R' section and into the 'O' section.
9 The dead bolt extends. There is no restore force in the 'O' section.
3. Move the thumb-turn slightly over the threshold between the 'O' and 'R'
section in the same direction of rotation.
9 The dead bolt will extend. The restore force must turn the thumb-
turn automatically from this point as far as the 'U' section if it is released.
9 If the thumb-turn does not automatically rotate as far as the 'U'
section, either the fastening screw has been tightened too firmly or the locking device has been aligned incorrectly. The test is to be repeated after the fault has been eliminated. A fastening screw which has been tightened too firmly acts as a brake on the restoring force mechanism.
4. Lock the door and check that the locking device functions correctly by
pressing the door fitting or panic bar in the direction of escape.
9 The dead bolt must spring back and it must be possible to open the
door easily.
9 If the dead bolt does not draw back when the handle is turned or the
door fitting catches, either the locking cylinder or the locking device is incorrectly aligned or defective. The test is to be repeated after the fault has been eliminated as described above.
Please contact the lock manufacturer if you are unable to ensure that the locking device functions correctly after the functional test.
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
30 / 54

6.3.3 Installation of SKG/VdS cylinders

Loosen the outside knob's threaded pin using an Allen key. Do not unscrew completely. Hold the inside knob firmly and then turn the outside knob anti-clockwise.
Turn the cam until it is vertical and pointing downwards. Insert the digital locking cylinder through the lock from the inner side. Fasten the cylinder into the mortise lock with the fastening screw. Then screw the outside knob back into position on the cylinder and tighten the threaded pin.
6.3.3.1 Installation of core extraction protection adapters (Z4.KA.SET)
The core extraction protection adapter (Z4.KA.SET) is compatible with all SKG/VdS cylinders manufactured up to 2010 and all .FD cylinders.
Instructions:
1. Disassemble the non-electronic knob.
2. Remove the rubber seal on the tip of the outside tube.
3. Place the core extraction protection adapter on the outside tube and
turn while applying a little pressure, so that it grips into the indents on the flange (in a similar way to the knob when installed). The openings in the adapter and the outside tube web must align.
4. Insert the supplied screw through the lock and tighten carefully.
5. Replace the knob and turn in an anti-clockwise direction while applying
slight pressure until the outer knob grips into the indents in the flange. Possibly place the knob in this position by pressing it gently towards the profile cylinder housing.
NOTE
Turning the bayonet disc when not installed may prevent the thumb-turn from being fastened into position. In such a case, push the disc back into the original 'bayonet disc open' position using the installation tool.
6. Place the installation key on the outside thumb-turn in such a way that
its two teeth engage into the outside thumb-turn (if necessary, turn the thumb-turn until both teeth lock into the locking disc). Lock the thumb­turn into position again by rotating it 30° in a clockwise direction.
6.3.3.2 Installation of core extraction protection adapters (Z4.KA.SET2)
The core extraction protection adapter (Z4.KA.SET2) is compatible with all SKG/VdS cylinders manufactured from 2011 onwards.
Instructions:
1. Disassemble the non-electronic knob.
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
31 / 54
2. Then screw the core extraction protection adapter into position on the
cylinder and lock into place using the threaded pins.
3. Install the non-electronic knob on the core extraction protection ad-
apter.
An elongated version of the adapter is available for the Italian market. (Z4.KA.SET2.IT).

6.3.4 Half Cylinder DK/MR

The thumb-turn, including the inside tube, can be removed from the cylinder housing to install the DK and MR versions. The procedure is described below. It is only necessary for key switches, for example, if the half cylinder cannot be installed using the fastening screw.
6.3.4.1 Disassembly
If you need to disassemble the half cylinder, please proceed as follows:
1. Using a tool such as a screwdriver, grip into the two slots in the plastic
disc between the thumb-turn and the profile cylinder housing and turn the tool while applying a little pressure. This breaks the disc.
2. Remove the remains of the plastic disc.
3. Engage the half cylinder using an authorised ID medium.
4. While the thumb-turn is engaged, turn it anti-clockwise until it will turn
no more (e.g. towards the lock when installed or holding the cam with your hand when not installed; see Step A in the diagram).
5. Press thumb-turn towards profile cylinder housing until it stops (you will
hear it click. If necessary, move thumb-turn backwards and forwards several times until you hear a click; see Step B and D in the diagram).
6. If needed, engage the half cylinder once more using an authorised ID
medium.
7. While the thumb-turn is engaged, turn it anti-clockwise and apply pres-
sure against the stop position (see Step B and D in the diagram).
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
32 / 54
8. While applying pressure, pull the thumb-turn (including inside tube)
from the profile cylinder (see Step D in the diagram).
NOTE
You must not strike the thumb-turn during installation. Do not allow the cylinder to come into contact with oil, paint or acids.
6.3.4.2 Installation
1. Remove the metal discs on the inside tube and push a plastic disc onto
it instead. You will find the plastic disc in the supplied package.
2. Push the removed metal discs onto the inside tube, so that a plastic
disc and a varying number of metal discs, depending on the half cylinder type, are on the inner tube.
3. Push the inner tube thumb-turn into the profile cylinder housing until it
stops.
4. Engage cylinder using an authorised ID medium.
5. While the thumb-turn is engaged, press it gently against the profile cyl-
inder housing while turning clockwise at the same time until the inside tube clicks into place in the profile cylinder housing.
NOTE
Check that it has locked into position correctly by pulling the thumb-turn gently while turning it backwards and forwards.
NOTE
You will find the required plastic discs in the supplied package.
When installing, ensure that only one plastic disc and the same number of metal discs are on the inner tube as when you took it apart. The plastic disc must be placed directly on the thumb-turn.
6.3.4.3 Functions test
1. Engage half cylinder using a valid ID medium and turn the thumb-turn in
the locking and opening direction with the door open. The thumb-turn must be able to rotate easily when you do so.
2. Close the door and repeat the process. If the half cylinder should be
stiff, you need to align the door or modify the strike plate.
Digital Locking Cylinder 3061
6. Installation instructions
(Manual)
33 / 54
This generally also applies when installing the cylinder in a key switch, for example.

6.3.5 Installing Swiss Round

Both cylinders and a fitting need to be removed from doors when installing a Swiss round cylinder.
The inside thumb-turn is removed and re-fitted in the same way as Half Cylinder DK / MR.
The outside knob is removed and re-fitted in the same way as the outside knob on a VdS cylinder.
1. Disassemble inside thumb-turn and outside thumb-turn. Remove a fit-
ting from the door.
2. Push cylinder into the profile and fasten with the fastening screw.
3. Fit inside thumb-turn and outside thumb-turn. Mount fitting again.
Digital Locking Cylinder 3061
7. Audible signals
(Manual)

7 Audible signals

The Locking Cylinder 3061 emits an audible signal to indicate its status and an authorisation. The table below lists what the audible signals mean.
2 short audible signals before engaging and a short tone after disen­gaging.
1 short audible signal: cylinder does not en­gage.
Normal activation None
Attempted entry with a transponder listed in the locking system, but:
used outside time
zone.
Activated alarm
system while using the SimonsVoss Block Lock.
None
34 / 54
Battery Warning Level 1: 8 short audible signals before engaging.
Battery Warning Level 2: 8 short audible signals 30 seconds long with one second pause each time before engaging.
Freeze mode (G2 only): 6 audible signals (long – pause – short).
8 short audible signals after disengaging.
Batteries are low.
Batteries are almost completely empty.
Battery empty. Cylinder can no longer be opened using an author­ised transponder. Cylin­der can only be engaged using a battery replace­ment transponder.
Transponder battery is low.
Replace batteries in the cylinder.
Replace batteries in the cylinder immediately.
Replace batteries and reset with a battery re­placement transponder.
Have transponder bat­tery replaced.

7.1 Battery warnings

A battery management system has been implemented in locking cylinders and transponders which warns the user in good time that the battery capacity is diminished. This prevents the batteries from becoming fully discharged. The individual battery warning levels are described below.
Digital Locking Cylinder 3061
7. Audible signals
(Manual)
The locking cylinder batteries feature a redundant system. If one of the batteries fails or its capacity falls below a certain level, the system emits a battery warning.
The battery warning levels between G1 and G2 differ after Battery Warning Level 2 if the battery capacity falls under the emergency battery warning threshold values.
Warning Level 1: Low batteries
If the charged capacity falls below 25% in one of the batteries, Battery Warning Level 1 is activated. After you activate the transponder, you will hear eight brief audible signals in rapid succession before the cylinder engages. You must replace the batteries.
Warning Level 2: Extremely low batteries
If the locking cylinder batteries discharge even further, short audible signals are heard in rapid succession for about 30 seconds before the cylinder engages after the transponder is activated. The cylinder does not engage until the audible signals have finished. The batteries should be replaced as quickly as possible.
35 / 54
If this warning level is ignored, the locking cylinder switches to what is known as storage or freeze mode.
Digital Locking Cylinder 3061
7. Audible signals
(Manual)
Emergency battery – Storage mode
(G1 cylinders):
In storage mode, the cylinder can only be opened with the aid of a programming device (SmartCD).
36 / 54
Emergency battery – Freeze mode (G2
cylinders):
In freeze mode, an audible signal will sound if an attempt is made to open using an authorised transponder, but the cylinder will not engage.
The G2 cylinder can now only be opened using a battery replacement transponder or programming device.
Active locking devices: The system
administrator can use a G2 battery replacement transponder (freeze mode transponder) for about 30 seconds to eliminate freeze mode and open the door with a user transponder to replace the batteries.
SmartCard locking devices: The
system administrator can use a "G2 battery replacement card" (freeze mode card) to permanently eliminate the freeze mode (including warning levels) and open the door to change the batteries using a user identification medium.
NOTE
After using a "G2 battery replacement medium" on locking devices, change the batteries immediately. Otherwise, the locking device may fail com­pletely due to empty batteries.
Active cylinder:
WARNING LEVEL1WARNING LEVEL
2
Eight short aud-
8 short audible signals before en­gaging
ible signals 30 seconds long with one second pause each time before engaging
FREEZE MODE
6 audible signals (long – pause – short)
Digital Locking Cylinder 3061
7. Audible signals
(Manual)
Cylinder SC (transponder use):
Cylinder SC (SmartCard use):
Up to 15,000 ac­cess events or up to 9 months on standby
8 short audible signals before en­gaging
LED flashes red briefly 8 times be­fore engaging
Up to 50 access events or up to 30 days
Eight short aud­ible signals 30 seconds long with one second pause each time before engaging
LED flashes red briefly twice for 30 seconds be­fore engaging
37 / 54
Battery replace­ment: activate with battery re­placement transponder
6 audible signals (long – pause – short)
LED flashes red once and blue once
Battery replace­Up to 300 access events or up to 30 days
Up to 200 access events or up to 20 days
ment: activate
with battery re-
placement
transponder

7.2 Battery warning for transponders

When the transponder battery is low, short audible signals are heard in rapid succession on the locking cylinder (not the transponder) after the locking cylinder disengages each time the transponder is used.
Digital Locking Cylinder 3061
8. System 3060 battery replacement
(Manual)
38 / 54

8 System 3060 battery replacement

8.1 General instructions

Only trained personnel may replace the batteries.
You must wear clean gloves made of cloth and free of fat or grease when replacing the batteries to prevent the batteries being contaminated by fingerprints. Fingerprints on batteries may reduce battery life considerably.
Only use batteries which have been approved by SimonsVoss.
NOTE
You may cause damage to the Locking Cylinder 3061 if you reverse the po­larity. The batteries used in this device may pose a fire or burn hazard if handled incorrectly. Do not recharge, open or burn batteries, or heat them to over 100° C.
NOTE
Dispose of lithium batteries properly immediately after they have dis­charged. Store them out of children's reach; do not open and do not throw into a fire. Always replace both batteries when changing batteries. Please note safety instructions.
The locking cylinder retains its status, programming and saved protocols even without power supply.

8.2 Battery life

Battery life is different for each locking cylinder version as power consumption varies when the cylinder is activated or a data connection is established.
VERSION BATTERY LIFE
Standard cylinder and versions
Up to 10 years Up to 300,000 2
NUMBER OF AC­TIVATIONS
NUMBER OF
BATTERIES
WN (LNI / LockNode)
The specified battery life is for guidance only. A battery warning is not emitted when the aforementioned battery life expires, but is based on the measured battery status instead.
Up to 5 years Up to 150,000 2
Digital Locking Cylinder 3061
8. System 3060 battery replacement
(Manual)
39 / 54

8.3 Emergency battery procedure

As stated above, a locking cylinder changes to storage mode (G1) or freeze mode (G2) if Battery Warning Level 2 is ignored. A different procedure is used each for G1 and G2 to eliminate this mode.

8.3.1 Storage mode (G1)

If the locking cylinder is in emergency battery storage mode, proceed as follows to open the door to change the battery and reset the cylinder.
1. Take notebook or PDA (import locking plan beforehand) and program­ming device to the door in question.
2. Select the corresponding lock from the locking plan.
3. Re-programme locking cylinder without making any modifications. This eliminates the battery warning and storage mode.
4. Engage the locking cylinder using an authorised transponder and open the door. The cylinder will immediately revert to storage mode, as both batteries are almost empty.
5. Renew batteries (see below).
6. Re-programme locking cylinder without making any modifications. This eliminates the battery warning check marks and storage mode.
7. Engage the locking cylinder using an authorised transponder.
After battery replacement, the locking cylinder signals Warning Level 2 again. The locking cylinder's electronics then detect that the batteries are fully charged or have been replaced and the cylinder is available for normal use again.

8.3.2 Freeze mode (G2)

Emergency opening of the door and elimination of emergency retention mode in G2 is easier than G1 generation systems.
1. Programme the G2 battery replacement transponder if necessary.
2. Deactivate freeze mode using the G2 battery replacement transponder.
3. Use an authorised transponder to engage the locking cylinder and open the door.
4. Replace the battery.
5. Deactivate freeze mode using the G2 battery replacement transponder.
6. Perform an opening transaction on the locking cylinder with an author­ised transponder to test that it is functioning and eliminate freeze mode.
Digital Locking Cylinder 3061
8. System 3060 battery replacement
(Manual)
40 / 54
NOTE
Only use the G2 battery replacement transponder to deactivate freeze mode and then immediately replace the cylinder batteries. Misuse may lead to complete battery discharge and, consequently, a complete failure of the cylinder.

8.4 Procedure

1. Place the installation/battery key on the inside thumb-turn in such a way that the two teeth lock into the openings in the locking disc; if ne­cessary, turn the thumb-turn until both teeth engage into the locking disc.
NOTE
The tool must be placed flat on the inside front surface of the recessed grip ring to ensure that the installation/battery key can engage into the locking disc.
2. Hold the inside thumb-turn firmly and carefully turn the installation/ battery key about 30° in a clockwise direction (until you hear a click).
3. Remove installation/battery key from the thumb-turn.
4. Push recessed grip ring backwards towards the door, so that it comes away from the thumb-turn.
5. Hold recessed grip ring firmly and turn thumb-turn about 10° in an anti­clockwise direction and remove.
6. For MH cylinders only: Carefully fold antenna upwards.
7. Carefully remove both batteries from the holder.
8. Insert the new batteries into the holder at the same time with the posit­ive poles next to each other; change the batteries as quickly as possible. Use clean gloves free of fat or grease to handle new batteries.
9. For MH cylinders only: Lock antenna back into place.
Digital Locking Cylinder 3061
8. System 3060 battery replacement
(Manual)
41 / 54
10. Replace the thumb-turn (align the triangle mark as in the diagram), hold the recessed grip ring firmly and fasten the inside thumb-turn by turning in a clockwise direction (about 10°). (Diagram may differ slightly from the purchased product)
11. Push recessed grip ring back onto the thumb-turn, so that the thumb­turn and ring close together in a flush fit.
12. Place the installation/battery key on the inside thumb-turn in such a way that the two teeth lock into the openings in the locking disc; if ne­cessary, turn the thumb-turn until both teeth engage into the locking disc.
13. Close the thumb-turn again by turning it about 30° in a clockwise direc­tion (until you hear a click).
Then activate an authorised ID medium and check that it functions.

8.5 Procedure for outer thumb turn (MH cylinder)

4 batteries are built into the MH cylinder: 2 in the inside thumb-turn, 2 in the outer thumb-turn.
Proceed as follows to replace the two batteries:
1. Use the battery replacement key to detach the outer thumb-turn. To do so, face the outer thumb-turn and place the battery replacement key on the bayonet mount and turn in a clockwise direction until you can re­move the thumb-turn easily.
9 The outer thumb-turn is now fully detached.
2. Place the battery replacement key on the detached thumb-turn again and open the bayonet mount completely
ection as you face the mount)
9 The lid springs open by itself as the bayonet mount is unscrewed.
3. Carefully lift off the lid.
9 The lid is attached to the thumb-turn with a small securing strap and
a ribbon cable; the batteries are now exposed.
4. Insert new batteries in such a way that the two plus poles lie flat on one another and then position in the thumb-turn.
. You may be able to skip this step.
( turn in an anti-clockwise dir-
NOTE
You should always replace both batteries with new ones when changing the batteries.
Digital Locking Cylinder 3061
8. System 3060 battery replacement
(Manual)
42 / 54
NOTE
You must place the ribbon cable loop crossways directly under the thumb­turn lid.
5. Reattach lid to the outer thumb-turn and press gently.
9 The lid is now flush against the outer thumb-turn.
6. Use the battery replacement key to lock the bayonet mount to a min­imum extent until the lid locks into the outer lid of its own accord. (about 1° in a clockwise direction)
7. Re-attach outer thumb-turn onto the locking cylinder.
9 The outer thumb-turn is now flush against the locking cylinder.
8. Now use the battery replacement key to lock the bayonet mount com­pletely. To do so, face the outer thumb-turn and place the battery re­placement key on the bayonet mount and turn in an anti-clockwise dir­ection until the thumb-turn is firmly in position.
9. Check that the outer thumb-turn is firmly attached again and test the locking cylinder function to ensure that it works.
Digital Locking Cylinder 3061
(Manual)

9 Maintenance, cleaning and disinfection

NOTE
Digital locking cylinders MUST not come into contact with oil, grease, paint or acids.
NOTE
The use of unsuitable or aggressive disinfectants can damage the locking cylinder.
Clean the locking cylinder if necessary with a soft, moist cloth.
9. Maintenance, cleaning and disinfec­tion
43 / 54
Only use disinfectants explicitly suitable for the disinfection of sensitive metal surfaces and plastic.
NOTE
HZ.SL:
closure lever handle.
Empty batteries always must be replaced by new ones approved for use by SimonsVoss. Dispose of old batteries in the proper manner.
Carry out a new functional test after changing the batteries in anti-panic cylinders.
It is recommended to grease the latching edge on the electrical en-
Digital Locking Cylinder 3061
10. Areas of use
(Manual)
44 / 54

10 Areas of use

10.1 General

The digital locking cylinder is compatible with locks for Euro profile cylinder as per DIN 18252 and EN1303.

10.2 Fire doors

As a general rule, this cylinder can be fitted into fire doors. However, you must check that it is actually approved for use in fire doors.

10.3 Doors along rescue routes

Type .AP should be installed for use in doors with an anti-panic function in which the position of the cam may have an effect on the lock's functioning. This must be specified in the lock manufacturer's approval. Also see industrial standards EN 179 and EN 1125 and the individual lock manufacturers' data sheets.

10.4 Installation outdoors

If you are unable to ensure that no water will come through the door, we recommend using the respective .WP versions. The outer thumb-turn is completely sealed in the anti-panic cylinder model and the whole cylinder is sealed in the double thumb-turn cylinder variant.
Digital Locking Cylinder 3061
11. Accessories
(Manual)
45 / 54

11 Accessories

11.1 Thumb-turns

The following special thumb-turns are available as accessories:
Outer thumb-turn in a TN4 design
Outer thumb-turn, 42 mm in diameter with recessed grips
Inside thumb-turn, 36 mm in diameter for a .TS cylinder
Outer thumb-turn, shortened
Brass thumb-turn, matt (inside and outer thumb-turn)
These thumb-turns can replace the original locking cylinder thumb-turns at any time. See Installation instructions or Battery replacement for thumb­turn installation.

11.2 Core extraction protection adapter (Z4.KA.SET)

This adapter is compatible with all SKG/VdS cylinders manufactured up to 2010 and all .FD cylinders.
There is a mechanical extension for core extraction protection fittings as the profile cylinder profile is not cut out of these fittings. The extension is 8 mm long and can be retrofitted at any time.

11.3 Core extraction protection extension for SKG/VdS cylinders (Z4.KA.SET2)

This adapter is compatible with all SKG/VdS cylinders manufactured in 2011 and onwards.
There is a mechanical extension for core extraction protection fittings as the profile cylinder profile is not cut out of these fittings. The extension is 8 mm long and can be retrofitted at any time.

11.4 Core extraction protection extension for SKG/VdS cylinders (Z4.KA.SET2.IT)

This adapter is compatible with all SKG/VdS cylinders manufactured in 2011 and onwards.
There is a mechanical extension for core extraction protection fittings as the profile cylinder profile is not cut out of these fittings. The extension length is 16 mm for special Italian escutcheons and can be retrofitted at any time.
Digital Locking Cylinder 3061
11. Accessories
(Manual)
46 / 54

11.5 Tool

In addition to the installation tool, a battery replacement key is also included in the supply package. You can use this tool to install or remove outer thumb-turns and replace batteries.

11.6 Battery set

A new set of batteries can be ordered, which contains ten CR2450 batteries. Only ever use batteries approved by SimonsVoss.
Digital Locking Cylinder 3061
12. Technical data
(Manual)

12 Technical data

Radio emissions
SRD (depending on equipment)
RFID (depending on equipment)
SRD (WaveNet) (de­pending on equipment)
There are no geographical restrictions within the EU.

12.1 Locking cylinder

24.50 kHz - 25.06 kHz
13.564 MHz - 13.564 MHz
868.000 MHz -
868.600 MHz
47 / 54
-20 dBµA/m (10 m dis­tance)
-19.57 dBµA/m (10 m distance)
<25 mW ERP
Profile cylinder
Basic length:
Installation lengths in 5mm increments, overall length up to 140 mm (max. 90mm on one side); special lengths on request.
Batteries
Type: CR, 2450, 3V
Manufacturer: Murata, Panasonic, Varta
Quantity: 2 units
Battery life:
Ambient conditions
Operating temperature: -25°C to +65°C
Storage temperature: -35°C to +65°C
Protection class:
Outside 30 mm, internal 30 mm (AP/WP 35mm)
up to 300,000 lock operations or up to 10 years on standby
Standard protection rating IP54 (when installed); .WP variant: IP66
Air humidity: <95%: non-condensing
Features
3,000 access events can be logged (ZK)
Network-ready with integrated LockNode (WN)
LockNode can be retrofitted
Time zone groups: G1: 5 / G2: 100
Max. number of transponders per G1 Cylinder: 8000 / G2: 64,000
Digital Locking Cylinder 3061
12. Technical data
(Manual)
48 / 54
Different permanent/open modes
Thumb-turns
Material: Stainless steel
Colours: Stainless steel, brushed
Diameter: 30 mm
Length: 37 mm (from front surface of profile)
FH cylinder thumb-turns
Inside thumb-turn: stainless steel
Material:
Colours:
cover; recessed grip: plastic; outer thumb-turn: identical to standard cylinders
Cover: brushed stainless steel; re­cessed grip: black; outside thumb­turn identical to standard cylinders
Diameter: 30 mm
Length: 37 mm (from front surface of profile)
AP cylinder thumb-turns
Material:
Colours:
Diameter: 30 mm
Length:
MS cylinder thumb-turns
Material:
Outside thumb-turn: identical to standard cylinders: Aluminium
Outside thumb-turn: Brushed stain­less steel; internal thumb-turn: Nickel-coated aluminium
Outside: 37 mm (from front surface of profile); internal: about 36 mm (from front surface of profile)
Outside thumb-turn: identical to standard cylinders; internal thumb­turn: identical to standard cylinders
Outside thumb-turn: Cover made of high-gloss brass; recessed grip: matt
Colours:
Diameter: 30 mm
brass: internal thumb-turn: Cover made of high-gloss brass; recessed grip: Matt brass
Digital Locking Cylinder 3061
12. Technical data
(Manual)
Length:

12.2 Half cylinder

Thumb-turns
Material: Stainless steel
Colours: Stainless steel, brushed
Diameter: 30 mm
Length: 37 mm (from front surface of profile)
Profile cylinder
Basic length: outside 30 mm, internal 10 mm
49 / 54
Outside: 37 mm (from front surface of profile)
Installation lengths in 5mm increments (no installation kit) an overall length of up to 100 mm with a maximum length of 90 mm on the outer side of the cylinder. Greater lengths on request.
Batteries
Type: CR, 2450, 3V
Manufacturer: Murata, Panasonic, Varta
Quantity: 2 units
Battery life:
Features
3,000 access events can be logged (ZK)
Network-ready with integrated LockNode (WN)
LockNode can be retrofitted
Time zone groups: G1: 5 / G2: 100
up to 300,000 lock operations or up to 10 years on standby
Max. number of transponders per G1 Cylinder: 8000 / G2: 64,000
Different permanent/open modes
Ambient conditions
Operating temperature: -25°C to +65°C
Storage temperature: -35°C to +65°C
Standard protection rating IP54
Protection class:
Air humidity: <95%: non-condensing
(when installed); .WP variant: IP66 thumb-turn
Digital Locking Cylinder 3061
12. Technical data
(Manual)
50 / 54
Cam HZ.SL
Cam position handle: 37°
Cam width from neutral position: 11 mm
Digital Locking Cylinder 3061
13. Declaration of conformity
(Manual)

13 Declaration of conformity

The company SimonsVoss Technologies GmbH hereby declares that article TN4-Zylinder
2014/53/EU "Radio equipment"
2014/30/EU "EMC"
2011/65/EU "RoHS"
2012/19/EU "WEEE"
and regulation (EG) 1907/2006 "REACH"
The full text of the EU Declaration of conformity is available at the following internet address:
certificates.html
complies with the following guidelines:
https://www.simons-voss.com/en/
.
51 / 54
Digital Locking Cylinder 3061
14. Help and other information
(Manual)

14 Help and other information

Information material/documents
You will find detailed information on operation and configuration and other documents under Informative material/Documents in the Download section on the SimonsVoss website (
downloads/documents.html
Declarations of conformity
You will find declarations of conformity for this product in the Certificate section on the SimonsVoss website (
certificates.html
Information on disposal
Do not dispose the device (TN4-Zylinder) in the household waste.
Dispose of it at a collection point for electronic waste as per European Directive 2012/19/EU.
).
).
https://www.simons-voss.com/en/
https://www.simons-voss.com/en/
52 / 54
Recycle defective or used batteries in line with European Directive
2006/66/EC.
Observe local regulations on separate disposal of batteries.
Take the packaging to an environmentally responsible recycling point.
Hotline
If you have any questions, the SimonsVoss Service Hotline will be happy to help you on +49 (0)89 99 228 333 (German fixed network; call charges vary depending on the operator).
Email
You may prefer to send us an email.
support@simons-voss.com (System 3060, MobileKey)
FAQs
You will find information and help for SimonsVoss products in the FAQ section on the SimonsVoss website (
public.pl
).
https://faq.simons-voss.com/otrs/
Digital Locking Cylinder 3061
14. Help and other information
(Manual)
53 / 54
SimonsVoss Technologies GmbH Feringastrasse 4 85774 Unterföhring Germany
This is SimonsVoss
SimonsVoss is a technology leader in digital locking systems.
The pioneer in wirelessly controlled, cable-free locking technology delivers system solutions with an extensive product range for SOHOs, SMEs, major companies and public institutions.
SimonsVoss locking systems unite intelligent functions, optimum quality and award-winning German-made design. As an innovative system provider, SimonsVoss attaches great importan-
ce to scalable systems, effective security, reliable components, high-perform­ance software and simple operation.
Our commercial success lies in the courage to innovate, sustainable thinking and action, and heartfelt appreciation of employees and partners. With its headquar­ters in Unterföhring, near Munich, and its production site in Osterfeld, eastern Germany, the company employs around 300 staff in eight countries.
SimonsVoss is a company in the ALLEGION Group, a globally active network in the security sector. Allegion is represented in around 130 countries worldwide (www.allegion.com).
© 2019, SimonsVoss Technologies GmbH, Unterföhring
All rights are reserved. Text, images and diagrams are protected under copyright law.
The content of this document must not be copied, distributed or modified. More information about this product can be found on the SimonsVoss website. Sub­ject to technical changes.
SimonsVoss and MobileKey are registered brands belonging to SimonsVoss Technologies GmbH.
Loading...