Sime Planet Dewy 60 BFR, Planet Dewy 100 BFR User Instructions

PLANET DEWY
60-100 BFR
User instructions
UK
PLEASE LEAVE THIS INSTRUCTION
WITH THE USER
The Benchmark Scheme
Sime Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimi­se safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www
.centralheating.co.uk
IPX4D
Planet Dewy 60 BFR: Gas Council number 41-283-03 Planet Dewy 100 BFR: Gas Council number 47-283-11
These appliances comply with the S.E.D.B.U.K. scheme, band “A”
OPERATING INSTRUCTIONS FOR THE USER
1 LIGHTING AHD OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pag. 4
1.1 BOILER IGNITION
1.2 BOILER SHUTDOWN
1.3 TEMPERATURE ADJUSTMENT (WITHOUT LOGICA)
1.4 GAS CONVERSION
1.5 CLEANING AND MAINTENANCE
1.6 MALFUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pag. 5
2 LOGICA REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pag. 6
CONTENTS
VERY IMPORTANT!
60 BFR boiler only
PLEASE MAKE SURE YOUR BENCHMARK CHECKLIST IN THE
INSTALLATION GUIDE, IS FILLED IN CORRECTLY.
ALL GAS SAFE REGISTER INSTALLERS CARRY A ID CARD.
THE REGISTRATION NUMBER SHOULD BE
RECORDED ON THE CHECK LIST.
YOU CAN CHECK YOUR INSTALLER IS GAS SAFE
REGISTERED BY CALLING ON 0800 408 5577
1.1 BOILER IGNITION (fig. 1)
Open the gas isolation valve, lower the con­trol cover and turn on the boiler by rotating the selector knob to winter ( ). The green led ( ) turn on to indicate that power is on. The boiler, once the tempera­ture set on the potentiometer is reached, will start automatically modulate to provide the system with the required output.
1.2 BOILER SHUTDOWN (fig. 1)
To turn OFF the boiler, turn the selector knob to (OFF). For prolonged periods of disuse, disconnect the power supply, close the gas tap and, in the event of low tempe­ratures, empty the boiler and hydraulic system to prevent frost damaged.
1.3 TEMPERATURE ADJUSTMENT (WITHOUT LOGICA) (fig. 2)
Heating temperature is adjusted using the heating knob ( ). The set temperature is indicated on the red led scale from 35 ­80°C and the yellow heating led ( ) turns on simultaneously. If the water return tem­perature is lower than about 55° C, combu­stion product condensates further increa­sing heat exchange efficiency. Unless a domestic hot water cylinder is connected, the DHW control knob has no function.
1.4 GAS CONVERSION
Should it be necessary to convert the appliance to a different gas from the one for which the boiler has been equipped, seek advice from a qualified technician.
1.5 CLEANING AND MAINTENANCE
Preventive maintenance and checking of the efficient operation of the equipment and safety devices must be carried out exclusively by the authorized technical staff. Should any component require replacement, only manufacturers original parts must be used.
WARNINGS
– In case of fault and/or incorrect equipment operation, turn the boiler off. Contact an authorised technician. – The installation of the boiler and any servicing or maintenance must be carried out by qualified personnel. Under no
circumstances must the devices sealed by the manufacturer be tampered with.
– Any ventilation or air intake grills to the room where the boiler is installed must be kept open and unobstructed.
1 LIGHTING AND OPERATION
APRE
SPIA VERDE
Fig. 1
SPIA GIALLASPIA ROSSA
Fig. 2
OPEN
GREEN LED
RED LED YELLOW LED
4
OPERATING INSTRUCTIONS FOR THE USER
1.6 MALFUNCTIONS
Ignition lockout (fig. 3)
If the burner does not light the red led ( ) turns on. To attempt ignition again, rotate the selector knob to ( ) and release it immediately returning it to win­ter position ( ).
If the problem persists, contact a authorised engineer .
Insufficient water pressure (fig. 4)
If the “0.5 bar” red light blinks, the boiler does not work. To restore operations, fill the system until the green “1 bar” led turns on. If all leds are off, request an authorised engineer.
Safety/exhaust thermostat
triggered (fig. 5) If the safety/exhaust thermostat trig­gers the red “35°C” led blinks. To attempt ignition again, rotate the selec­tor knob to ( ) and release it immedia­tely returning it to winter position ( ).
If the problem persists, contact an authorised engineer.
Other faults (fig. 6)
When one of the red “40-80°C” leds blinks, turn off the boiler and attempt ignition again. This operation can be repeated 2-3 times at most, in the event of failure, request an authorised engineer.
SPIA ROSSA INTERMITTENTE
Fig. 6
SPIA ROSSA
Fig. 3
Fig. 4
SPIA ROSSA INTERMITTENTE IN CONDIZIONE DI SICUREZZA
SPIA ROSSA INTERMITTENTE
Fig. 5
RED LED
FLASHING RED LED
FLASHING RED LED
IN SAFETY CONDITION
FLASHING RED LED
5
6
When the boiler is connected to the “Logi­ca Remote Control” regulator, the selector CR/OFF/SUM/WIN/UNBLOCK must be placed in the position ( ); the knobs of the hot-water service heating potentiometers do not have any effect and all of the func­tions will be managed by the regulator (fig.
7). If the “Logica Remote Control” fails, the
boiler will function by placing the selector on the ( o ), position, obviously without consequent control of the room temperature.
The operating instructions are located insi­de the cover (fig. 8). Each setting or modifi­cation is displayed (fig. 9).
2 LOGICA REMOTE CONTROL
1
6
7
8
4
5
3
2
KEY 1 Display 2 Info button 3 Operating mode button: automatic operation 4 Operating mode button: manual operation 5 Operating mode button: availability 6 Cover with instruction compartment 7 Temperature knob 8 Presence button
Fig. 8
KEY
1 Display, time 2 Heating programme 3 Unit (% / C°) 4 Presence button display 5 External temperature 6 Outside temperature (if sensor fitted) 7 Holiday function 8 Operating mode
9 Line number/day 10 Burner on 11 Heating function 12 Domestic hot water/temperature/D.H.W. load
Fig. 9
Fig. 7
“PLANET DEWY 60-100 BFR” BOILER INSTALLATION IN SEQUENCE/CASCADE
WHEN THE BOILER IS CONNECTED TO REGULATOR RVA 47.320 IN SEQUENCE/CASCADE INSTALLA­TIONS, ALL BOILERS IN THE HEATING UNIT MUST HAVE THEIR “CR/OFF/INV/RELEASE” SELECTORS POSITIONED AS INDICATED IN FIG. 7. THE HEATING POTENTIOMETER AND WATER KNOB NO LONGER HAVE ANY CONTROL AND ALL FUNC­TIONS WILL BE CONTROLLED BY THE TVA 47.320 REGULATOR.
7
The fixed temperature can be adjusted with the control knob.
Before adjusting it again, however, allow the temperature to stabilise first.
Note: With the temperature knob you can only adjust the fixed temperature, the reduced tem-
perature remains the same.
Adjusting the temperature
If you turn the knob towards the + sign, the fixed temperature is increased by about 1 °C for every notch.
If you turn the knob towards the - sign, the fixed temperature is decreased by about 1 °C for every notch.
Ensure that the radiators in the room with the Logica do not have thermostatic valves, and are not turned off.
For every operation of the Info key the fol­lowing list of items, one after the other, are displayed. The thermo-feeler continues to function independently of the display.
Day, hour, room temperature
External temperature*
Hot-water service temperature*
* Only with outside sensor fitted.
Info key
(reference key grey colour)
The operating mode desired is selected by pressing the relative key with the correspon­ding symbol. The choice is displayed with the symbol
Automatic functioning: the heating functions automatically according to the hea­ting programme entered. The programme may be excluded for brief periods with the on-line key.
Manual functioning: the heating functions manually according to the choice made with the on-line key.
Availability: the heating is deactivated.
Selection of the operating mode
(reference keys grey colour)
ACTIVATING
During functioning the lid of the regulator must be closed.
8
If the rooms remain unused for a long period of time, the temperatu­re can be reduced with the on-line key, in this way saving energy. When the rooms are occupied again, press the on-line key to re-heat them. The current choice is displayed on the display:
On-line key
Fixed temperature heating
Reduced temperature heating
NOTE:
In automatic mode, the apparatus switches from the fixed temperature to the reduced tem­perature according to the time programme. The manual switching of the temperature is done manually with the on-line key.
Temperature regulation
Fixed temperature: temperature when the rooms are occupied (basic setting)
Reduced temperature: temperature during periods of absence or night
Hot-water service temperature: – desired temperature of hot-water service – comfort temperature of the hot-water service
(with hot water cylinder unit)
Reduced temperature of hot-water service (with hot water cylinder unit): temperature desired for hot-water service at reduced level. To have access to the “reduced hot-water service temperature” parameter, press the and keys at the same time for at least 5 seconds and then go along the entered lines with the key until parameter 61 is reached. Regulate the value with and
.
Before proceeding with the adjustment in the temperature on the regulator, the thermostatic valves, which may be present, have to be regulated to the desired temperature.
1
2
3
61
PROGRAMMING
To enter the programming mode the flap on the control must be open.
As soon as the cover is open, the display and the key functions are switched on. The number in the square represents the programme lines that may selected with the arrow keys.
You can set or display the following values:
• Temperatures up to
• Heating programme up to
• Day of the week and hour up to
• Current values up to
• Holiday period
• Return to the default values
1
3
4
11
12
14
15
17 18 19
If the control is in the manual mode , If the control is in the automatic mode the control will revert automatically at the next change of the heating programme.
Programme line
Value
Value adjustment keys
Programme line selector
9
Programme for hot-water service
(with storage capacity boiler unit)
Select the days that correspond with the heating phase. 1= Monday, ... 7 = Sunday/8 = hot-water service programme
Start of phase 1: Start of first comfort period.
End phase 1: End of first comfor t period.
Start phase 2: Start of second comfor t period.
End phase 2: End of second comfort period.
Start phase 3: Start of third comfort period.
End phase 3: End of third comfort period.
Copying of the daily programme
By pressing this key it is possible to repeat the current heating programme for the next day.
By pressing this key it is possible to repeat the current heating programme for the previous day.
As a confirmation the following day is displayed.
4 5 6
7 8 9
10
11
With the Logic Remote Control it is possible to manage the temperature of boiler unit on two levels (a comfort level and one at reduced temperature) in accordance with the programme chosen with parameter 62 (load hot-water service). To have access to the parameter press the and keys for at least 5 seconds and then go along the entered lines with the key until parameter 62 is reached. At this point four dif ferent programmes may be selected with o keys, with the following characteristics:
0 = 24 hours/ day - Hot water always available at the temperature set in parameter 3. 1 = standard - Hot water according to the daily heating programme. In the comfort periods
of the heating the temperature of the boiler unit is regulated at the value set via para­meter 61.
2 = sservice suspended. 3 = second daily programme (8) - Everyday of the week the temperature of the hot-water ser-
vice is set according to programme B. In this case the programming is one for all the days of the week and three periods of time are available. In the periods of time set, the tem­perature of the boiler unit is controlled via the temperature setting of parameter 61.
Start phase 1: Start time of first comfort period.
End phase 1: End time of first comfor t period
Start phase 2: Start time of second comfor t period.
End phase 2: End time of second comfort period.
Start phase 3: Start time of third comfort period.
End phase 3: End time of third comfort period.
5 6
7 8 9
10
– Heating/hot-water
service programme
With the heating programme it is possible to set the switching times of the temperature for a period of a week. The weekly programme consists of 7 daily programmes. One daily program­me allows 3 phases of heating. Each phase is defined by a star ting time and a finishing time. The n. 8 daily programme is for the hot-water service (if storage unit connected). If a phase is not required, the same st arting and finishing time may be entered.
10
68
69
70
192
193
195
Heating sensor fault (SM)
Call an authorised Service Centre.
Insufficient water pressure
Re-pressurise the boiler using the filling loop.
Plant overpressure
Call an authorised Service Centre.
Safety thermostat trips
Call an authorised Service Centre.
Ventilator malfunction
Call an authorised Service Centre.
No communication between the "Logica Remote Control" and the boiler.
Call an authorised Service Centre.
1
0
– Error display
Ignition lock-out
Rotate selector CR/OFF/EST/INV/RESET on the boiler control panel to the release position ()
to reset operation. If the lock-out re-occurs, call an authorised Service Centre.
Safety thermostat trip
Rotate selector CR/OFF/EST/INV/RESET on the boiler control panel to the release position ()
to reset operation. If the lock-out re-occurs, call an authorised Service Centre.
Default values
To reset the Logica to the default values, press the and keys at the same time for at least 3 seconds. As confirmation a sign will appear on the display.
19
ATTENTION
The values of the following line numbers previously entered will be lost.
• Temperature and time programme to
• Holiday period
1
10 18
Holiday function
To enter the number of days of absence.
In the display the holiday symbol will be shown ( ), on the left the day of activation (1 = Monday/7 = Sunday) and on the right the number of days holiday.
18
During the holiday the regulator will be on the availability mode.
When the set days have elapsed, the regulator will go on to the automatic function.
NOTE:
The holiday period may be cancelled by pressing a key of the operating mode.
Current values
Display and setting of the gradient of the heating characteristics curve. When the room temperature set is not reached choose the gradient indicated in point 2.8.3
Display of the current boiler temperature.
Display of the current power of the burner and of the current operating mode ( = = heating/ = hot-water service)
15
16
17
Setting the time
To set the current day of the week (1 = Monday/7 = Sunday)
To set the current hour
To set the current minute Once the hour is completed, the setting of the hour changes.
12 13 14
With and keys the current hour is regulated. Pressing these keys together, the regulation is speeded up in an increasing sense.
Cod. 6304379 - 01/10 - Documentation Dpt.
Sime Ltd
1a Blue Ridge Park Thunderhead Ridge Glasshoughton, Castleford, WF10 4UA
Phone: 0845 9011114 Fax: 0845 9011115
www.sime.ltd.uk Email: enquiries@sime.ltd.uk