Sime Murelle 30 OF, Murelle series, Murelle 25 OF, Murelle 25 OFT, Murelle 25 BF Installer's Instructions

...
INSTALLER INSTRUCTIONS
CONTENTS
1 DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 108
2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 114
3 CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 127
4 USE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 132
IMPORTANT
– Make sure that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
– Make sure that the electrical connections have been made correctly and that the earth wire is connected to a
good earthing system.
– Open the gas tap and check the soundness of the connections, including that of the burner.
– Make sure that the boiler is set for operation for the type of gas supplied.
– Check that the flue pipe for the outlet of the products of the combustion is unobstructed and has been properly
installed.
– Make sure that any shutof f valves are open.
– Make sure that the system is charged with water and is thoroughly vented.
– Check that the circulating pump is not locked.
– Purge the system, bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas
valve inlet.
– The installer must provide the user with instruction in operation of the boiler and safety devices and hand over the
instruction booklet to the user.
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, which bear the CE mark under Gas Dir ective 90/396/CEE and are fitted with a safety ther mostat calibrated to a maximum of 110°C, are not subject to application of PED Directive 97/23/CEE as they meet the requirements of article 1 paragraph 3.6 of the Directive.
108
IT
ES
PT
GB
1.1 INTRODUCTION
“ M U R E L L E ” a r e t h e g a s f u e l l e d b u r n e r
group s for h eating and the production of h o t sanita ry w a te r, const ru c ted to satisfy the needs of collective residential housing and modern plant. T h e y a r e a p p a r a t u s e s w h i c h c o n f o r m t o t h e E u r o p e a n d i r e c t i v e s 9 0 / 3 9 6 / C E , 2 0 04 / 108 /CE, 2 006/95/CE and 92/42/CE. Th e can be fuelled by natur a l
gas (G20) or LPG (G30-G31). This booklet g i v e s t h e i n s t r u c t i o n s f o r t h e f o l l o w i n g models: – “MURELLE 25-30 OF” w i t h e l e c t r o n i c
m o d u l a t i o n i g n i t i o n , o p e n c o m b u s t i o n chamber with natural draw
– “MU RELLE 25 OFT” o n l y h e a t i n g , w i t h
electronic modulation ignition, open com­b u s t i o n c h a m b e r a n d n a t u r a l d r a w , which can be connected to D.H.W. stora­ge tank .
– “MURELLE 25-30-35 BF” w i th elect ro-
nic modulation ignition, sealed combu­stion chamber forced flow.
“MURELLE 20-25 BFT” o n l y h e a t i n g ,
w i th electronic modulation ignitio n, sea­l e d c o m b u s t i o n c h a m b e r a n d f o r c e d fl ow, which can be connected t o D.H.W.
storage tank. The instructions given in this manual are provided t o ensure proper installation and perfect operation of the appliance.
1 DESCRIPTION OF THE BOILER
1.2 DIMENSIONS
1.2.1 “25-30 OF” models
198
55
55
ø D
70
70 70 70
=
=
125
60
350
L
=
=
Fig. 1
CONNECTIONS R C.H. return
G 3/4” (UNI-ISO 228/1)
M C.H. flow
G 3/4” (UNI-ISO 228/1)
G Gas connection
G 3/4” (UNI-ISO 228/1)
E D.H.W. inlet
G 1/2” (UNI-ISO 228/1)
U D.H.W. outlet
G 1/2” (UNI-ISO 228/1)
DIMENSIONS 25 30 L mm 400 450 D mm 130 150
1.2.2 “25 OFT” models
350
107
12 5 6 0
400
40 71
707061
ø 130
==
19 8
55
55
RM G
M2
R3
G
G R
M
C
C
==
Fig. 1/a
CONNECTIONS R C.H. return G 3/4” (UNI-ISO 228/1) M C.H. flow G 3/4” (UNI-ISO 228/1) G Gas connection G 3/4” (UNI-ISO 228/1) R3 D.H.W. tank return G 3/4” (UNI-ISO 228/1) M2 D.H.W. tank output G 3/4” (UNI-ISO 228/1) C System loading G 1/2” (UNI-ISO 228/1)
ATTE NT I ON: T h e “OFT” ve rsion is designed for t he connection of a re m oteboiler,touseitasaboiler ONLY FOR HEATING it is necessary:
- to disconnect D.H.W. sensor (SB)
- set the PAR 2 to 4.
All modules are designed to be used by qualified technical personnel.
109
IT
ES
PT
GB
60
70 70
40 71
55
55
16 5
350
60
12 5
107
400
18 0
==
Fig. 1/c
1.2.4 “20 - 25 BFT” models
CONNECTIONS R C.H. return G 3/4” (UNI-ISO 228/1) M C.H. flow G 3/4” (UNI-ISO 228/1) G Gas connection G 3/4” (UNI-ISO 228/1) R3 D.H.W. tank return G 3/4” (UNI-ISO 228/1) M2 D.H.W. tank output G 3/4” (UNI-ISO 228/1) C System loading G 1/2” (UNI-ISO 228/1)
70 70 70 70
==350
12 5
60
L
16 5
K
55 55
Fig. 1/b
1.2.3 “25 - 30 - 35 BF” models
CONNECTIONS
R C.H. return
G 3/4” (UNI-ISO 228/1)
M C.H. flow
G 3/4” (UNI-ISO 228/1)
G Gas connection
G 3/4” (UNI-ISO 228/1)
E D.H.W. inlet
G 1/2” (UNI-ISO 228/1)
U D.H.W. outlet
G 1/2” (UNI-ISO 228/1)
DIMENSIONS
25 30 35
L mm 400 450 450
K mm 180 205 205
ATTENTION: The “BFT” version is desi­gne d for t he conn ection of a re m ot e b o i l e r, to use it as a b oiler O N LY F O R HEATING it is necessary:
- to disconnect the D.H.W. sensor (SB)
- set the PAR 2 to 4.
All modules are designed to be used by qualified technical personnel.
110
IT
ES
PT
GB
* Gas consumption figures e xpress the lowest calorific power of pure gas under standard conditions at 15°C – 1013 mbar; this figur e may dif fer from the actual
figure, which is dependent on gas composition and environmental conditions.
Models 25 OF 30 OF 25 OFT 25 BF 30 BF 35 BF 20 BFT 25 BFT
Heat output
Nominal kW 23.0 27.0 23.0 23.7 28.0 32.4 19.8 23.7
Reduced kW 8.7 10.2 8.7 8.8 10.4 11.8 7.3 8.8
Heat input
Nominal kW 25.5 30.0 25.5 25.5 30.0 34.8 21.3 25.5
Reduced kW 10.2 12.0 10.2 10.2 12.0 13.5 8.5 10.2
Thermal yield 100% useful 90.0 90.0 90.0 93.0 93.3 93.1 93.0 93.0
Thermal yield useful at 30% of load 89.5 89.5 89.5 92.0 92.0 92.0 92.0 92.0
Termal efficiency (CEE 92/42 directive) ★★ ★★ ★★ ★★★ ★★★ ★★★ ★★★ ★★★
Losses after shutdown to 50°C (EN 483)
W/h 200 235 200 89 96 96 89 89
Supply voltage V-Hz 230-50 230-50 230-50 230-50 230-50 230-50 230-50 230-50
Adsorbed power consumption W 75 90 80 100 115 135 105 105
E l e c t rical pr otection gra d e IP X4D X4D X4D X4D X4D X4D X4D X4D
C.H. setting range °C 30÷80 30÷80 30÷80 30÷80 30÷80 30÷80 30÷80 30÷80
Water content boiler l 7.1 8.0 7.1 7.1 8.0 8.0 7.1 7.1
Maximum water head bar 3 3 3 3 3 3 3 3
Maximum temperature °C 85 85 85 85 85 85 85 85
Header tank capacity l7 8 7 7 8 8 7 7
Header tank pressure bar 1 1 1 1 1 1 1 1
D.H.W. setting range °C 30÷60 30÷60 - 30÷60 30÷60 30÷60 - -
D.H.W. flow rate (EN 625) l/min 10.7 12.7 - 11.1 13.2 15.3 - -
Continuous D.H.W. flow rate t 30°C l/min 10.9 12.9 - 11.3 13.4 15.5 - -
Minimum D.H.W. flow rate l/min 2.4 2.4 - 2.4 2.4 2.4 - -
D.H.W pressure min/max bar 0.2/7 0.2/7 - 0.2/7 0.2/7 0.2/7 - -
D.H.W. pressure min. nom. power bar 0.5 0.65 - 0.5 0.65 0.8 - -
Smokes temperature min/max °C 88/122 95/135 88/122 100/125 100/125 95/130 95/115 100/125
Smokes flow min/max g/s 18/20 18/20 18/20 16/16 18/18 21/21 15/15 16/16
CE certification No. 1312BS5038 1312BS5037
Category II
2H3+
II
2H3+
Type of appliance B
11BS
B
22P-52P/C12-32-42-52-62-82
NOx emission class 3 (<150 mg/kWh) 3 (<150 mg/kWh)
Weight when empty kg 30 33 30 38 40 40 37 37
Main burner nozzle
Quantity nozzles n ° 12 14 12 12 14 15 10 12
G20 nozzle diameter mm 1.30 1.30 1.30 1.30 1.30 1.30 1.30 1.30
G30/G31 nozzle diameter mm 0.77 0.77 0.77 0.77 0.77 0.80 0.76 0.77
Gas consumption *
Natural gas (G20) m
3
/h 2.70 3.17 2.70 2.70 3.17 3.68 2.25 2.70
LPG (G30/G31) kg/h 2.01 2.37 2.01 2.01 2.37 2.74 1.68 2.01
Burner gas pressure min/max
Natural gas (G20) mbar 1.8/11.0 1.9/11.1 1.8/11.0 2.0/11.8 2.1/12.0 2.2/13.7 1.9/11.0 2.0/11.8
Butane (G30) mbar 4.7/27.7 4.8/27.7 4.7/27.7 4.8/28.5 5.0/28.5 4.5/28.2 4.8/28.5 4.8/28.5
Propane (G31) mbar 4.7/35.7 4.8/35.7 4.7/35.7 4.8/36.5 5.0/36.5 4.5/36.2 4.8/36.5 4.8/36.5
Gas supply pressure
Natural gas (G20) mbar 20 20 20 20 20 20 20 20
Butane (G30) mbar 28–30 28–30 28–30 28–30 28–30 28–30 28–30 28–30
Propane (G31) mbar 37 37 37 37 37 37 37 37
1. 3 T E C H N I CAL F E A T U R E S
111
IT
ES
PT
GB
1
2
3
4
25
15
8
24
7
11
17
13
16 14
20
19
22
23
12
28
29
30
27
26
31
21
U
E
GMR
C
1.4 FUNCTIONAL DIAGRAM
Fig. 2
“25-30 OF/25-30-35 BF” models
“20-25 BFT/25 OFT” models
23
9
4
3
2
1
7
24
8
12
11
17
13
19
6
16
14
20
22
21
18
5
15
UEG MR
KEY
1 Fan (BF - BFT model) 2 Primary exchanger 3 Combustion chamber 4 Gas valve 5 D-H.W. exchanger with plates 6 Pressure switch valve with loading 7 C.H. sensor (SM) 8 Safety thermostat
9 D.H.W. sensor (SS) 11 Circulator with air release vent 12 Expansion vessel 13 3 BAR safety valve 14 Boiler discharge 15 Water flow meter 16 Water pressure transducer 17 Automatic bypass 18 D.H.W. filter 19 C.H. return cock (optional) 20 C.H. flow cock (optional) 21 D.H.W. cock (optional) 22 Gas cock (optional) 23 Connection plate (optional) 24 Aqua Guard Filter System 25 Motorised deviator valve 26 Filler group (optional) 27 D.H.W. storage tank BT 100 (optional) 28 Boiler discharge (optional) 29 D.H.W. sensor (SB) 30 D.H.W. expansion vessel 4 litre (optional) 31 D-H.W. safety valve 7 BAR (optional)
CONNECTIONS
U D.H.W. outlet
E D.H.W. inlet
G Gas connection
M C.H. flow
R C.H. return
C Syst em loading
112
IT
ES
PT
GB
11
10
9
8
7
6
5
4
3
2
1
1.5 MAIN COMPONENT S
Fig. 3
KEY
1 3 BAR safety valve 2 Control panel 3 Gas valve 4 Burner s 5 Combustion chamber 6 Smoke chamber
7 Smoke stat 8 C.H. sensor (SM)
9 Main exchanger
10
Ignition/detection electrode
11 Coupling protection
“25 - 30 OF/25 OFT” models
113
IT
ES
PT
GB
11
13
9
8
7
6
5
4
3
2
1
12
10
14
Fig. 3/a
KEY
1 3 BAR safety valve 2 Control panel 3 Burners 4 Combustion chamber 5 Fan 6 Combustion analysis intakes 7 Negative pressure intake
8 Positive pressure intake
9 Smoke pressure switch 10 C.H. sensor (SM) 11 Main exchanger 12 Ignition/detection electrode 13 Gas valve 14 Coupling protection
“25 - 30 - 35 BF/20 - 25 BFT” models
114
IT
ES
PT
GB
The boiler must be installed in a fixed loca­t i o n a n d o n l y b y s p e c i a l i z e d a n d q u a l i f i e d f i r m s i n c o m p l i a n c e w i t h a l l i n s t r u c t i o n s contained in this manual. Furthermore, the installation must be in accordance with cur­rent standards and r egulations.
2.1 INSTALLATION
-
In the rooms where “type B” boiler s are i n s t a l l e d , t h e a i r r e q u i r e d f o r c o r r e c t c o m b u stion of the gas consumed by th e appliance must be able to flow in. It is the­re f o re necessary to make openings t h a t c a n n o t b e b l o c k e d i n t h e o u t e r w a l l s , w h i ch mus t be at least 6 cm
2
for eve ry kW of thermal capacity inst alled and with, in any case, a minimum of 100 cm
2
.
- “Type C” a pp l i a n c e s , w i t h c o m b u s t i o n chamber and air supply sealed of f fr o m the environment, can be inst alled in any room in the house.
- “Type B and C” b oilers ar e suitabl e fo r functioning in a partially prot ected place, as according to EN 297, with maximum environmental temperature of 60°C and minimum of -5°C. We recommend instal­lation of these boilers under the protru­ding slope of a roof, on a balcony, or in a p r o t e c t e d n i c h e , a l w a y s p r o v i d i n g t h e y a r e n o t d i r e c t l y e x p o s e d t o a d v e r s e weather (rain, hail, snow). The boilers are provided already equipped with anti-free­ze functions.
2.1.1 Anti-freeze function
T h e b o i l e r s a r e e q u i p p e d w i t h a n t i - f r e e z e function which activates the pumps and the burner when the temperature of the water c o n t a i n e d i n s i d e t h e a p p l i a n c e d r o p s t o below 6°C. The anti-freeze function is ensu­red, however, only if:
- the boiler is correctly connected to the
gas and electricity supply circuits;
- the boiler is constantly fed;
- the boiler ignition is not blocked;
- the essential components of the
boiler are all in working order In these condition s the boiler is prot e c te d a g a i n s t f r o s t d o w n t o a n e n v i r o n m e n t a l temperature of -5°C.
ATTENTION: In the case of installation in a place where the temperature drops below 0°C, the connection pipes must be pro­tected.
2.2 COMPLEMENTARY
ACCESSORIES
To f a c i l i t a t e c o n n e c t i n g t h e b o i l e r t o t h e s ys t em , t he f o l l owi ng a cc es so ri es c an be supplied on request, complete wit h instruc­tions for assembly:
- Installation plate code 8075416
- C u r v e t t e an d g as t a p s / s a n i t a r y w a t e r
output set code 8075418
- Taps kit code 8091806
- P o l y p h o s p h a t e s d o s e r k i t c o d e 81071700
- K i t o f c o u p l i n g s f o r r e p l a c i n g w a l l - h u n g boilers of other makes code 8093900
- Solar kit for the insta n taneous code 8105101
- H y d r a u l i c c o n n e c t i o n k i t b o i l e r BFT/BT100 tank unit code 8091111.
2.3 CONNECTING UP SYSTEM
To prot ect the heat system from damaging c o rrosion, incru station or deposits, befo re i n s t a l l a t i o n i t i s e x t r e m e l y i m p o r t a n t t o clean t he sys tem using su itable p ro d u c t s s u c h a s , f o r e x a m p l e , S e n t i n e l X 3 0 0 o r X400. Comp l ete inst ructions are prov i d e d with the products but, for further informa­t i o n , y o u m a y d i r e c t l y c o n t a c t S E N T I N E L PERFORMANCE SOLUTIONS LTD. For long-te rm p rotection again s corro s i o n and deposits, the use of inhibitors such as Sentinel X100 is recommended after clea­ning th e syst em. It is i mp o rtant t o ch e ck the concentration of the inhibitor afte r each system modification and during main­t e n a n c e f o l l o w i n g t h e m a n u f a c t u r e r ’ s instructions (specific tests are available at your dealer). The safety valve drain must be c o n n e c t ed to a collection funnel to collect any di sch a rge dur ing int e r vention s. If th e heating system is on a higher floor t han the boiler, install the on/off taps supplied in kit o ptional on t he heating syste m delivery/return pipes.
WA R N I NG: F a i l u re t o c l ea n th e heat system or add an adequate inhibitor invalidates the device’s
warranty.
Gas connections must be made in accor-
dance with cur rent sta n d a rds and r e g u l a­tions. When dimensioni ng gas pipes fr o m the meter to t he module, both capacity volume (consu mption) in m
3
/h and ga s density must be taken into account. The sections of the piping making up the system must be such as to guarantee a supply of gas sufficient to cover the maxi­m u m d e m a n d , l i m i t i n g p r e s s u r e l o s s between the gas met er and any apparatus being used to not greater than: – 1.0 mbar for family II gases (natural gas); – 2.0 mbar f or fa m i ly III gases (butane or
propane).
An adhesive data plate is sticked inside the front panel; it contains all the technical data identifying the boiler and the type of gas for which the boiler is arranged.
2.3.1 Filter on the gas pipe
The gas valve is supplied ex factory with an inlet filter, which, however, is not adequate to entrap all the impurities in the gas or in gas main pipes. To prevent malfunctioning of the valve, or in certain cases even to cut out the safety device with which the valve is equipped, install an adequate filter on the gas pipe.
2.5 SYSTEM FILLING
Filling of the boiler and the system is done by the charge cock (2 fig. 4). The charge pressure, with the sys tem cold, must be between 1 and 1.5 bar. During system fil­ling you are recommended to keep t he main switch turned OFF. Filling must be done slowly so as to allow any air bubbles to be
2 INSTALLATION
Fig. 4
8 1
10 11 3 2 9 4
675
12
8
12
13 11
9
4
14
“25-30 OF/25-30-35 BF” models
“20-25 BFT/25 OFT” models
KEY
1 Sanitary water header 2 Fill tap 3 D.H.W. filter 4 By-pass 5 Water rate adjuster 6 D.H.W. exchanger 7 Microswitches 8 Water flow switch
9 Boiler discharge 10 D.H.W. sensor 11 Water pressure transducer 12 Safety t hermostat 13 Deviator v alve 14 Syst em loading connection
115
IT
ES
PT
GB
bled of f through the air valves. Should the pressure have risen well above the limit expected, discharge the o ver pressure by opening the pressure-relief valve.
N.B. The OFT/BFT versions are loaded by means of the special coupling indicated in figs. 1/a - 1/c
2.5.1 Emptying the system
Use the drain tap to empty the system (9 fig. 4). Turn off the boiler before doing this.
2.6 FLUES/CHIMNEYS
A chimney or flue for the e vacuation of the c o m b u stion products into t he atmosphere must correspond to the requisites prescri­bed by the laws in force. I n p a r t i c u l a r, t h e s p e c i f i c p r e s c r i p ti o n s o f law relative to boilers with natural draught in collective pipes (type B) and those for boi­l e rs with fo rced draught (type C) must be respected.
2.6.1 Ducting of existing chimneys
To recover or duct existing chimneys, ducts d e c l a r e d s u i t a b l e f o r t h e p u r p o s e b y t h e manufacturer must be used, and the instal­lation a nd use modalities in dicated by th e s a i d m a n u f a c t u r e r m u s t a l s o b e f o l l owe d a s w e l l a s t h e p r e s c r i p t i o n s o f S t a n d a r d UNI 10845.
2.7 INSTALLATION OF COAXIAL DUCT (versions "BF - BFT")
2.7.1 Accessories 60/100
The 60 /100 coaxial duc t is su pplied on request in kit code 8084811. The diagrams o f f ig. 5 illust ra te some exa mple s of diffe rent ty pes of disch a rge modalities allowed and the maximum
lengths that can be reached.
2.7.2 Diaphragm for 60/100 coaxial duct
The boiler is supplied with a diaphragm of
84 (version 20 BFT), 86 (versions 25-35 BF/25 BFT) and 87.5 (version 30 BF). The diaphragms 87.5 (code 6028824) and 86 (code 6028623) can be requested separa­tely. Use the diaphragms according to the indications of fig. 5/a.
C12
C32
C42
3
1
2
7
6
4
328
x
y
max 5,0 m per vers. “20” max 3,5 m per vers. "25" max 3,0 m per vers. "30-35"
x + y = max 5,0 m per vers. "20" x + y = max 3,5 m per vers. "25" x + y = max 3,0 m per vers. "30-35"
KEY 1 Coaxial flue kit L. 810 code 8084811 2 a Extension L. 1000 code 8096103 2 b Extension L. 500 code 8096102 3 Vertical extension L. 200 code 8086908 4 Additional 90° cur ve code 8095801 6 Ar ticulated tile code 8091300 7 Roof outlet terminal L. 1284 code 8091200 8 Vertical condensation collector L. 200 code 8092803
Fig. 5
IMPORTANT: – E a c h a d d i t i o n a l 9 0 ° c u r v e
installed reduces the available length by 1.0 metres.
– E a c h a d d i t i o n a l 4 5 ° c u r v e
installed reduces the available length by 0.50 metres.
- The inser tion of the condensa­tion collector (8) is obligatory for vertical stretches of more than 1.3 metres.
For discharge types C12-C42, use the diaphragms supplied with the boiler:
- ø 84.0 for version “20” only when the length of the coaxial duct is less than 2 metres,
- ø 86.0 for version “25-35” only when the length of the coaxial duct is less than 1 metre,
- ø 87.5 for version “30” only when the length of t he coaxial duct is less than 2 metres.
For discharge types C32, use the following diaphragms according to the length of the duct and without additional curves:
Installations with vetrical Installations with vertical condensation
extension L. 200 code 8086908 * collector code 8092803 *
“20 BFT” models “20 BFT” models
Diaphragm Diaphragm Without Diaphragm Diaphragm Without
ø 84 ø 86 diaphragm ø 84 ø 86 diaphragm
(code 6028622) (code 6028623) (code 6028622) (code 6028623)
L max = 4 m L max = 5 m ---- L max = 3 m L max = 5 m ---
“25 BF - 25 BFT - 30 BF - 35 BF” models “25 BF - 25 BFT - 30 BF - 35 BF” models
Diaphragm Diaphragm Without Diaphragm Diaphragm Without
ø 86 ø 87,5 diaphragm ø 86 ø 87,5 diaphragm
(code 6028623) (code 6028624) (code 6028623) (code 6028624)
L max = 2.5 m L max = 4 m L max = 5 m --- L max = 2.5 m L max = 4 m
* Minimum length of duct L = 1.3 m.
Fig. 5/a
116
IT
ES
PT
GB
2.7.3 Accessories 80/125
The 80 coaxial duct is supplied on request in a kit code 808483 0 comp l ete with assembly instructions.
Wi th the curve supplied in the kit, the maxi­m um ho ri z o n t a l l en g t h o f t h e d uc t mu s t b e no more than 6 met re s .
The diagrams in fig. 6 show some examples of the diffe rent types of 80/125 coaxial discharge modalities.
2.8 INSTALLATION OF SEPARATE DUCTS (versions “BF - BFT”)
When installing, the provisions of the law s in force must be adhered to, as well as cer­tain practical suggestions:
– Wi th aspiration dire c t ly fr om outside,
when the duct is longer than 1 metre, it is advisable to insulate the said duct in o r der to avoid th e fo r mation of dew on the outside of the pipe when the weather
is particularly cold.
– W i t h d u c t s w i t h d i s c h a r g e p o s i t i o n e d
outsid e t he bui lding, or in cold env i ro n­ments, i nsulation is necessar y to a vo i d d i fficulty in sta r ting the burn e r. In th e s e cases, a condensation system on th e pipes must be provided for.
– If the pipe passes th rough inf l a m m a b l e
walls, insulat e the st ret ch of the fumes d i s ch a rge pipe t hat passes t h rough th e
C12
C32
C42
2
7
6
4
1
2
8
x
y
x + y = min. 3,5 m/max 6 m "25" x + y = min. 3,0 m/max 6 m "30-35"
5
5
3
8
2
1
1
min. 3,5 m - max 6 m "25" min. 3,0 m - max 6 m "30-35"
2
Fig. 6
KEY 1 Coaxial duct kit code 8084830 2 Extension L. 1000 code 8096130 3 Vertical extension L. 200 with coupling code 8086908 4a Additional 90° curve code 8095820 4b Additional 45° curve code 8095920 5 Adapter for 80/125 code 8095920 6 Tile for joint code 8093120 7 Terminal for roof exit L. 1284 code 8091200 8 Vertical condensation collector L. 200 code 8092803
IMPORTANT: – Each additional 90° cur ve installed reduces the available length by 1.0 metres. – Each additional 45° cur ve installed reduces the available length by 0.80 metres. – The insertion of the condensation collector (8) is obligatory in C32 discharge type. – The i nsert ion of the condensatio n c ollect or (8) is obl iga to ry in C42 disch a rge typ e
when the stretch "y” is longer than 1.3 metres.
117
IT
ES
PT
GB
wall with rounded glass wool 30 mm thick and with a density of 50 kg/m2.
Th e ma xi mu m to t al le ng th , w h i ch i s t h e sum of lengths of the aspiratio n and discharge pipes, is determined by the loss of charge of the single accessories inser­ted and must not result as more than 7.0 mm H
2
O in version “20” - 7.6 mm H2Oin
version “25”-9mmH
2
O in version “30” -
12 mm H
2
O in version “35”.
For the loss of ch a rge of the accessori e s , refer to Table 1 and to the example given in fig. 7.
2.8.1 Separate ducts kit
The separate ducts kit code 8089904 (fig.
8) is supplied with the aspiration diaph­ragm which must be used, according to the maximum los s of ch a rge allo wed in both the ducts, as indicated in fig. 8/a. To use the air inta ke vent in this type of discharge, the following operations mus t be carried out (fig. 9): – Re m ove the ba se of the air inta ke ve n t
by cutting it with a tool (a);
Example of allowable installation “25 BF” calculation in that the sum of the head losses of the single fittings is less than 7.6 mm H
2
O:
Intake Outlet
7 meter horizontal pipe ø 80 x 0.20 1.40 – 7 meter horizontal pipe ø 80 x 0.30 2.10 No. 2 90° elbows ø 80 x 0.35 0.70 – No. 2 90° elbows ø 80 x 0.40 0.80 No. 1 wall terminal ø 80 0.15 0.50
Total head loss 2.25 + 3.40 = 5.65 mmH
2
O
With this total head loss, remove the segments from No. 1 to No. 7 fr om diaphragm in t he intake pipe.
1
2
3
4
6
Fig. 8
Fig. 8/a
Fig. 7
KEY 1 ø 125/95 sponge seal 2 Fixing screw 3 Flue outlet flange 4 Inlet air diaphr agm 6 Manifold with intakes
20 25 30 35
K mm 180 180 205 205
TABLE 1
Accessories ø 80 Load loss (
mmH2O)
20 25 30 35
Intake Outlet Intake Outlet Intake Outlet Intake Outlet
90° curve MF 0.30 0.35 0.35 0.40 0.45 0.50 0.65 0.70
45° curve MF 0.25 0.30 0.30 0.35 0.40 0.45 0.60 0.65 E x t ensi on L. 1000 (hori z o n t a l ) 0 .15 0.25 0.20 0.30 0.25 0.35 0.30 0.40
E x tensi on L . 1000 (ve rt i c a l ) 0 .15 0.05 0.20 0.10 0.25 0.15 0.30 0.20
Wall terminal 0.10 0.40 0.15 0.50 0.20 0.80 0.20 1.20
T-shaped condensation collector --- 0.70 --- 0.80 --- 1.00 --- 1.40
Roof exit terminal* 1.30 0.05 1.60 0.10 2.00 0.20 2.50 0.30
* The loss of the roof exit terminal in aspiration concludes the collector code 8091400
No. s e g m e n t s Total load loss
mm H2O
to re m ove
20 25 30 35
none 0 ÷ 2.0 0 ÷ 0.8 - -
No. 1 2.0 ÷ 3.0 0.8 ÷ 1.6 - -
No.1e2 3.0 ÷ 4.0 1.6 ÷ 2.4 0 ÷ 1.0 0 ÷ 1.0 from No. 1 t o 3 4.0 ÷ 5.0 2.4 ÷ 3.1 1.0 ÷ 2.0 1.0 ÷ 2.0 from No. 1 t o 4 5.0 ÷ 6.0 3.1 ÷ 3.8 2.0 ÷ 3.0 2.0 ÷ 3.0 from No. 1 t o 5 6.0 ÷ 7.0 3.8 ÷ 4.5 3.0 ÷ 4.0 3.0 ÷ 4.0 from No. 1 to 6 --- 4.5 ÷ 5.2 4.0 ÷ 4.8 4.0 ÷ 5.0 from No. 1 to 7 --- 5.2 ÷ 5.8 4.8 ÷ 5.6 5.0 ÷ 6.0 from No. 1 to 8 --- 5.8 ÷ 6.4 5.6 ÷ 6.4 6.0 ÷ 7.0 from No. 1 t o 9 --- 6.4 ÷ 7.0 6.4 ÷ 7.2 7.0 ÷ 8.0
from No. 1 to 10 --- - 7.2 ÷ 8.0 8.0 ÷ 10.0
without diaphragm
--- 7.0 ÷ 7.6 8.0 ÷ 9.0 10.0 ÷ 12.0
118
IT
ES
PT
GB
– Turn the air intake vent upside down and
replace the gasket (5) with that supplied in the kit code 8089904;
– Insert the aspiration diaphragm supplied
in t he kit code 80899 04, pushing it home;
Only for versions "20 BFT” fit onto the
diaphragm the plastic reducer supplied together with the boiler.
Now the extension or the curve can be fit­ted into the special seat in order to comple­te the aspiration pipe (no washer or sealant is necessary).
2.8.2 Outlet systems
The diagrams in f ig. 9/a illust ra te a num­ber of examples of different types of sepa-
max 0,5 m
C12 B52
1
4
9
C52 B52
C32
C42
3
2
11
10
C82 B22
6
5
6
12
3
11
10
3
7
1
8
3
1
3
2
3
3 2
1
3
23
6
3
1
8 3
KEY
1 Separate flue kit code 8089904
2a
90° elbow MF (n° 6) code 8077410
2b
90° elbow MF with intake code 8077407
2c
Isolated 90° elbows MF code 8077408
3a
Extension L. 1000 (n° 6) code 8077309
3b Insulated e
xtension L. 1000 code 8077306
3c
Extension L. 500 (n° 6) code 8077308
3d
Extension L. 135 code 8077304
4
Outlet terminal code 8089501 5 Int.-est. ring kit code 8091500 6
Intake terminal code 8089500 7
45° elbow MF (n° 6) code 8077411 8
Condensation outlet L. 135 code 8092800 9 Doubler fitting code 8091400
10 Tile with ar ticulated joint code 8091300 11 Roof outlet terminal L. 1390 code 8091201 12 Tee condensation outlet code 8093300
a
b
5
Fig. 9/a
IMPORTANT: In type C52 the outlet and inlet flues must not come out on opposite walls.
ATTENTION: The three seats fore­seen on the diaphragm allow for fit­ting the air intake vent in only one position (the enumeration of th e sectors faces inwards).
Fig. 9
CONFIGURATION C62: discharge and aspiration is by means of pipes available on sale and certified separately (the pressure loss in the ducts must be calculated according to the St andard UNI EN 13394)
In vers. “20 BFT” fit the plastic reducer supplied with the boiler in the position indicated.
Loading...