Sima RCW-101,RCW-102,RCW-103,RCW-303,RCW-305 User Manual

DIGITAL RADIO
CONTROLLED WATCH
INTRODUCTION
Congratulations on your purchase of the Sima RCW. Before you begin using the RCW, please read this manual carefully and keep this manual for further information.
ABOUT NIST
also automatically adjusts for daylight
saving time, leap years, and leap seconds. For more details about the NIST Clock, please visit
www.NIST.gov
AUTOMATIC TIME SETTING
The RCW receives the NIST signal automatically at 3:00AM every night. Once the NIST signal is received the watch will display the official U.S. time. The time and date are set automatically for Eastern Standard Time, which will need to be adjusted if you are located in a different time zone. If the signal cannot be received, the RCW also can be set manually.
BEFORE USING THE RCW
The time zone that you are located in must be selected. Setting the correct time zone will allow the watch to set itself to the correct time.
This watch should be set manually for the first time. After that, the watch will automatically adjust itself to maintain accurate time.
SETTING THE TIME ZONE
The RCW will automatically set the time and date when a NIST signal is received successfully. However, you will still have to set the correct time zone. (Note: The RCW will not automatically adjust to a new time zone if you are traveling. You must change the time zone setting to continue to keep the exact time.)
TIME ZONE SETTING
1. Press the MODE button three times and the time zone will be displayed.
2. Press and hold the SET button for three seconds or until the offset hours digits begin to flash.
3. Press the RECEIVE button to increase or press the LIGHT button to decrease the hour-offset.
4. For standard time: (Eastern = -5) (Central = -6) (Mountain = -7) (Pacific = -8)
5. Press the SET button once to return to normal operation.
MANUAL TIME AND DATE SETTING
1. Press and hold the SET button for
three seconds and “12” or” 24” will blink on the LCD.
Press the RECEIVE or LIGHT button to change the setting from 12 to 24 or 24 to
12.
2. Press the SET button to advance to
the year setting.
Press the RECEIVE button to increase the year or LIGHT button decrease the desired year.
3. Press the SET button to advance to
the month setting.
Press the RECEIVE button to increase the month or LIGHT button decrease the desired month.
4. Press the SET button to advance to
the day of the month.
Press the RECEIVE button to increase the day or LIGHT button to decrease the day of the month.
5. Press the SET button to advance to
the day of week.
Press the RECEIVE button to increase
WATCH DISPLAY ICONS & BUTTONS
or the LIGHT button to decrease the day of the week.
6. Press the SET button to advance to hours.
Press the RECEIVE button to increase the hour or the LIGHT button to decrease the hour.
7. Press the SET button to advance to minutes.
Press the RECEIVE button to increase the minute or the LIGHT button to decrease the minute.
8. Press the SET button to advance to seconds.
Press the RECEIVE button or the LIGHT button to reset the seconds to
“00”.
9. Press the SET button one more time to return to normal operation.
BUTTONS AND FUNCTIONS
RECEIVE BUTTON
Pressing and holding the RECEIVE button for five seconds activates the manual signal receiver. Pressing the RECEIVE button while in manual setup will increase the digits displayed on the LCD. Press and hold the RECEIVE button to increase the numbers at a faster rate.
LIGHT
Pressing the LIGHT button activates the RCW backlight. Pressing the LIGHT button while in manual setup decreases the digits displayed on the LCD. Press and hold the LIGHT button to decrease the numbers at a faster rate.
Online Product Registration
http://www.simacorp.com
Models RCW -101 RCW -103 RCW -303 RCW -305
1. AM/PM Indicator
2. Time Zone indicator
3. NIST Reception
4. Daylight Saving Time Indicator,
5. Day of Week
SETTING ALARM 1 & ALARM 2
The RCW has two alarms that can be activated, AL1 and AL2. Pressing any button will turn the alarm sound off once activated. If no button is pushed, it will automatically shut off after two minutes.
1) Press the MODE button once for AL1, twice for AL2. The icon will blink on the right side of the LCD.
2) Press and hold the SET button for three seconds.The hour section of the clock will begin blinking.
3) Press the RECEIVE button to increase the hour or the LIGHT button to decrease the hour.
4) Press the SET button to move to the minute section of the clock.
5) Press the RECEIVE button to increase the minute or the LIGHT button to decrease the minute.
6) Press the SET button to advance to the ON / OFF setting.
7) Press the RECEIVE button to set the alarm to ON or OFF.
The icon for ON/OFF is located above the second portion of the clock (on=ON, oF=OFF).
8) The RCW will return to normal
operation in approximately 15 seconds.
SET
Pressing and holding the SET button for three seconds enters the manual setup mode. Different settings can be accessed by pressing the SET button repeatedly .
MODE
Press the MODE button to enter the alarm-setting menu.
EL (RCW-101 only)
Pressing the EL button will activate the RCW backlight.
6. Month & Day
7. Hours: Minutes: Seconds
8. Alarm Indicators (AL1 + AL2)
9. EL - Light (RCW 101 only)
RECEIVE
SET
LIGHT
MODE
1
3
4
5
6
7
8
9
2
SIGNAL SEARCH
AUTOMATIC SEARCH
The RCW is designed to receive the NIST signal automatically every night at 3:00AM. The RCW will synchronize the time and date with the NIST broadcast signal from Fort Collins, CO. Note: You must set the
watch manually the first time for it to auto synch during the night.
RECEPTION STATUS
If the NIST broadcast is successfully received, the tower icon in the upper left corner of the LCD will remain “on” all day. The RCW will search for the signal again at 3:00AM.
If the reception was not successful, the tower icon will be “off” which means that the signal was not received in the past 24 hours. The RCW will automatically search at 3:00AM everyday to update its time. (Note: If the tower icon is not “on” in the upper left corner, follow the instructions in the MANUAL SIGNAL SEARCH section).
MANUAL SIGNAL SEARCH
When the tower icon is not present in the upper left hand corner of the LCD the NIST signal has not been received in the previous 24 hours. The RCW searches for the NIST transmission at 3:00AM every night; which is the best time to receive the signal. In the event that your RCW does not have the tower icon displayed the RECEIVE button can be pressed to attempt to receive the signal.
1. Press and hold the RECEIVE button for ten seconds to activate the signal receiver. The tower icon will begin to
flash for up to ten minutes.
2. Do not press any buttons during the manual signal search time.
SIGNAL STRENGTH
While the RCW is searching for the NIST signal the tower will have rings that blink around it to display the strength of the signal being received. If the tower only displays one ring around the tower icon, the reception is poor in the area that you are located. Move to a different area and attempt to receive the signal again.
If the RCW is receiving a strong signal, three rings will be displayed around the tower icon. However, even when a strong signal is received the RCW may not automatically adjust the time due to RF interference.
TIME CHANGE ADJUSTMENT
If the RCW receives the NIST signal at 3:00AM during the fall or springtime change, it will automatically adjust to the correct Daylight Saving Time. During Daylight Savings time, each time the signal is received, the “sun” icon will also be displayed with the tower.
(Note: If you live in an area that does not observe the daylight savings time change, you will have to manually change the time zone setting ahead one time zone as this feature cannot be turned off).
TROUBLESHOOTING
At times the RCW may be placed in a location where the NIST signal reception becomes difficult due to interference. Interference can be due to electrical appliances such as televisions, refrigerators, computers, fluorescent lamps, or natural events such as thunderstorms. It is important that you do not leave your watch on a metallic surface and keep it away from any sources of electromagnetic interference.
If you continue to have unsuccessful NIST signal reception, you may want to place your watch near a window where it shows a strong reception signal. The NIST signal will usually be received at approximately 3:00AM when the signal reception is the strongest.
CARE OF YOUR WATCH
- Never attempt to open the case or remove the back-cover, as the watch contains no components that are user serviceable.
- Never swim with the RCW or submerge it under water. Should water or condensation appear in the watch, take the RCW to a jeweler to check immediately as water can corrode electronic parts inside the watch.
- Avoid exposing the watch to long periods of extreme temperatures. Normal operation between of the RCW is 0° C­50° C/32° F-122° F.
LIMITED WARRANTY
Sima Products Corp. (“Sima”) warrants that if the accompanying product proves to be defective to the original purchaser in material or workmanship within 90 days from the original retail purchase, Sima will, at Sima’s option, either repair or replace same without charge (but no cash refund will be made).
What you must do to enforce Warranty: You must deliver, mail or ship the product, together with both the
original bill of sale and this limited Warranty statement as proof of warranty coverage to:
Sima Products Corp. Attention: Customer Service 140 Pennsylvania Ave. Bldg. #5 Oakmont, PA 15139
Sima Products Corporation shall have no liability for any damages due to lost profits, loss of use or anticipated benefits, or other incidental, consequential, special or punitive damages arising from the use of, or the inability to use, this product, whether arising out of contract, negligence, tort or under any warranty, even if Sima Products Corporation has been advised of the possibility of such damages. Sima Products Corporation’s liability for damages in no event shall exceed the amount paid for this product. Sima Products Corporation neither assumes nor authorizes anyone to assume for it any other liabilities.
To receive special offers and discounts, register online at www.simacorp.com.
© 2005 Sima Products Corporation PN 21726
- The RCW is designed to withstand impact under normal use only. The RCW is not designed for rough usage or to be dropped onto hard surfaces.
- Keep your RCW away from the strong electromagnetic fields and static electricity.
- Clean the RCW with a soft cloth only.
SERVICE
The RCW is only to be opened by an experienced jeweler. The user should never open the RCW.
BATTERY REPLACEMENT
The RCW requires CR2025 battery. Y our RCW is a delicate instrument and requires special tools for changing the battery; therefore, Sima strongly recommends that qualified personnel only change the battery. Automatic reception of the NIST signal will activate once the battery is replaced.
Loading...