SilverStone ST1500 User Manual

STRIDER
ST1500
The dream PSU for computer enthusiasts
1500W continuous and 1600W peak power
100% modular cables with cable bag
Efficiency 85%~88% at 20%~100% loading with 80 PLUS Silver certification
Class-leading eight +12V rails with 110A (Peak up to 120A)
1500W continuous power output with 40C operating temperature
Four PCI-E 8pin, eight PCI-E 6pin, and twelve SATA connectors support
Support ATX 12V 2.3 & EPS 12V
O
Strict ±3% voltage regulation
Japanese main capacitors
Active PFC
SilverStone STRIDER ST1500
ATX12V / EPS 12V Switching Power Supply
With Active PFC
PS/2 1500W
This specification describes the requirements of 1500Watts switching power supply with an stretch form-factor and EPS12V, +5V standby voltage, remote on/off control, full range line input capability and forced air cooling characteristics.
1. AC INPUT
1-1. AC input requirements
The input voltage, current, and frequency requirements for continuous operation are stated below.
Table 1 AC Input Line Requirements
Iin
Power factor correction (PF)>0.95 at full load.
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC,and over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device)
18----9.0
Arms
2. DC OUTPUT
2-1. DC voltage regulation
ŔŕœŊŅņœġŔŕIJĶıı
Parameter
+3.3V
+5V
+12V1,2,3,4,5,6,7,8
-12V
+5VSB
MIN NOM MAX Units Tolerance
+3.20
+4.85
+11.64
-10.8
+4.75
+3.30
+5.00
+12.00
-12.20
+5.00
+3.39
+5.15
+12.36
-13.20
+5.25
Vms
Vms
Vms
Vms
Vms
2-2. Load ranges
Load Range
Parameter Min Nom. Max Peak Unit
+3.3V
0.8
-
40
-
+/-3%
+/-3%
+/-3%
+/-10%
+5/-5%
Amps
+5V
+12V1
+12V2
+12V3
+12V4
+12V5
+12V6
+12V7
+12V8
-12V
+5VSB
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0
0
-
-
-
-
-
-
-
-
-
-
-
40
25
25
25
25
25
25
25
25
0.5
6.0
-
30
30
30
30
30
30
30
30
-
8
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
1.Maximum continuous total DC output power should not exceed 1500W.
2.Maximum c.ontinuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 280W.
3.Maximum peak total DC output power should not exceed 1600 W.
4.Peak power and current loading shall be supported for a minimum of 12 second.
5.Maximum combined current for the 12 V outputs shall be 110A.
6.Peak current for the combined 12V outputs shall be 120A.
2-3. Output Ripple
2-3-1. Ripple regulation
Parameter Ripple&Noise Unit
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
+12V5
+12V6
+12V7
+12V8
-12V
+5VSB
50
50
120
120
120
120
120
120
120
120
120
50
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
2-3-2. Definition