Unparalleled combination of power, efficiency, and flexibility
600W 24hour continuous power output with 40 C operating temperature
Efficiency 85%~88% at 20%~100% loading
Class-leading single +12V rail with 42A
Silent running 135mm fan with 19dBA minimum
Strict ±3% voltage regulation
Dual EPS 8pin connectors support
Support ATX 12V 2.3 & EPS 12V
O
100% modular cables
Japanese main capacitors
Active PFC
2. DC OUTPUT
STRIDER PLUS SERIES
SPECIFICATION
SilverStone Strider Plus ST60F-P
ATX12V / EPS 12V Switching Power Supply
With Active PFC
PS/2
This specification describes the requirements of ST60F-P with active P.F.C Switching Power Supply with an ATX form-factor,+5V standby voltage, fan control, ATX 12V Power supply version 2.3, remote on/off control, dual line input capability and forced air cooling characteristics.
1. Table1 1. AC INPUT requirements
The input voltage, current, and frequency requirements for continuous operation are stated below.
2.1 Table 2. DC voltage regulation
Parameter
Parameter
+3.3V +5V +12V
-12V +5VSB
Range
Min
+/-3% +/-3% +/-3% +/-10%
+/-5%
Min
+3.20 +4.85 +11.64
-10.80 +4.75
Nom
Max Unit
+3.3 +5.0
+12.0
-12.0 +5.0
Peak
Max
+3.39 +5.15 +12.36
-13.2
+5.25
Unit
Volts Volts Volts Volts Volts
Nom
2.2 Load Ranges
2.2.1 Table 3 Typical Power Distribution for a 600W ATX12V Configuration
Cross Loading graph for 600w Configuraton
5V +3.3V power(W)
Parameter
Vin
Vin Frequency
Iin
1.1 Inrush current limiting
50 A @ 115Vrms 100 A @ 230Vrms (at 25 C ambient cold start).
01
Min. Nom. Max. Unit
103
47
o
115
60 10
240
50
5
264
63
VACrms
Hz
A
+12V power(W)
Table 4 Typical Power Distribution for a 600W ATX12V Configuration
Nom
Parameter
Parameter
+12VDC +5VDC +3.3VDC
-12VDC +5VSB
Min
Min
0.6
0.2
0.1
0.0
0.0
Nom
-
-
-
-
-
Max Unit
Max Unit
42.0
24.0
24.0
0.3
2.5
Peak
Peak
-
-
-
-
3.5
Amps Amps Amps Amps Amps