SilverStone SST-ST55F-GS User Manual

STRIDER GOLD S SERIES
SST-ST55F-GS SST-ST65F-GS SST-ST75F-GS
World’s smallest, full-modular ATX power supplies
Compact design with a depth of 140mm for easy integration
80 PLUS Gold certification
100% modular cables
24/7 continuous power output with 40 operating temperature
Class-leading single +12V rail
Silent running 120mm fan with 18dBA minimum
SPECIFICATION
SilverStone Strider Gold S
ST55F-GS ST65F-GS ST75F-GS
ATX12V / EPS 12V Switching Power Supply
With Active PFC
80 Plus Gold
PS/2
This specification describes the requirements 550W/650W/750W switching
power supply with an stretch ATX form-factor and EPS 12V, +5V standby voltage,
remote on/off control,full range line input capability and forced air cooling characteristics.
1.0 AC INPUT
1.1 AC input requirements
The input voltage, current, and frequency requirements for continuous operation are stated below.
Parameter Min Nom Max Unit Vin 90 100 ---- 240 264 VACrms Vin Frequency 47 60 ------- 50 63 Hz Iin(550W) 8.0 ----- 4.0 Iin(650W) 9.0 ----- 4.5 Iin(750W) 10.0 ---- 5.0
Power factor correction (PF)>0.9 at full load.
1.2 Inrush current regulation
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC,and over the specified temperature range (Top). The peak inrush current shall be less than the ratingsof its critical components (including input fuse, bulk rectifiers, and surge limiting device).
01
2.0 DC OUTPUT
2.1 DC voltage regulation
Parameter
+3.3V
+5V +12V –12V
+5Vsb
Range
±3% ±3% ±3% ±5% ±5%
Min +3.14 +4.75 +11.4
-11.4
+4.75
Nom
+3.3 +5.0
+12.0
-12.0 +5.0
Max +3.47 +5.25 +12.6
-12.6
+5.25
2.2 LOAD RANGE
2.2.1 550W Load range
Parameter
+3.3V
+5V
+12V
-12V
+5VSb
Notes: ( 1 ) The maximum combined load on +3.3V and +5V outputs shall not exceed 100W. ( 2 ) The +12V maximum load shall not exceed 540W. ( 3 ) The maximum continuous average DC outputs power shall not exceed 550W. ( 4 ) Peak DC output power should not exceed 600W for 12 second.
Min
0 0 0 0 0
Nom.
-
-
-
-
-
Max
20 20 45
0.3
2.5
Peak Unit
Unit Volts Volts Volts Volts Volts
Amps Amps Amps Amps Amps
2.2.2 650W Load range
Parameter
+3.3V
+5V
+12V
-12V
+5VSb
Notes: ( 1 ) The maximum combined load on +3.3V and +5V outputs shall not exceed 100W. ( 2 ) The +12V maximum load shall not exceed 648W. ( 3 ) The maximum continuous average DC outputs power shall not exceed 650W. ( 4 ) Peak DC output power should not exceed 700W for 12 second.
Min
0 0 0 0 0
Nom.
-
-
-
-
-
Max
20 20 54
0.3
2.5
Peak Unit
Amps Amps Amps Amps Amps
02
2.2.3 750W Load range
AC H ot
AC N eu tral
Power Supply
V out
V return
10uF 0.1uF
Load
Scope
AC Grou nd
Parameter
+3.3V
+5V
+12V
-12V
+5VSb
Min
0 0 0 0 0
Nom.
-
-
-
-
-
Max
20 20 62
0.3
2.5
Peak Unit
Amps Amps Amps Amps Amps
Notes: ( 1 ) The maximum combined load on +3.3V and +5V outputs shall not exceed 100W. ( 2 ) The +12V maximum load shall not exceed 744W. ( 3 ) The maximum continuous average DC outputs power shall not exceed 750W. ( 4 ) Peak DC output power should not exceed 800W for 12 second.
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter
+3.3V
+5V
+12V
-12V
+5VSb
2.3.2 Definition The ripple voltage of the outputs shall be measured at the pins of the output connector when
terminated in the load impedance specified in figure1.Ripple and noise are measured at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system loading. Ripple shall be measured under any condition of line voltage, output load, line frequency, operation temperature.
2.3.3 Ripple voltage test circuit
Ripple&Noise
50
50 120 120
50
Unit mVp-p mVp-p mVp-p mVp-p mVp-p
03
Loading...