SilverStone SST-ST1500-TI User Manual

Page 1
STRIDER TITANIUM SERIES
ST1500-TI/ST1300-TI/ST1100-TI
Premium, full-modular
80 PLUS Titanium power supplies
Top-level efficiency with 80 PLUS Titanium certification
All Japanese capacitors
100% modular cables
24/7 continuous power output with 50 operating temperature
Strict ±3% voltage regulation and low ripple & noise
Dual EPS 8pin with multiple PCI-E 8 / 6pin connectors support
Ultra silent 135mm fan with intelligent semi-fanless operation
Page 2
SPECIFICATION
SilverStone Strider Titanium
ST1500-TI ST1300-TI ST1100-TI
ATX12V / EPS 12V Switching Power Supply
With Active PFC 80Plus Titanium
PS/2
This specification describes the requirements of 1100W,1300W,1500Watts switching power supply with an stretch ATX form-factor and EPS 12V, +5V standby voltage, remote on/off control, full range line input capability and forced air cooling characteristics.
1. AC INPUT
The input voltage, current, and frequency requirements for continuous operation are stated below.
Table 1 AC Input Line Requirements
Parameter
Vin( Full range )
Vin Frequency Iin(ST1100-TI) Iin(ST1300-TI) Iin(ST1500-TI)
Power factor correction (PF)>0.90 at full load. The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC
voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
01
Min.
90 47
Nom.
100 --- 240
60 --- 50
12.0 --- 6.0
15.0 --- 7.5
17.6 --- 8.8
Max.
264
63
Unit
VACrms
Hz Arms Arms Arms
Page 3
2. DC OUTPUT
2.1 DC voltage regulation Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Note: Voltage tolerance is requied at main connector and S-ATA connector(if used)
Range
+/-3 +/-3 +/-3
+/-10
+/-5
Min +3.20 +4.85
+11.64
-13.20 +4.75
Nom. +3.30 +5.00
+12.00
-12.00 +5.00
Max +3.39 +5.15
+12.36
-10.80 +5.25
2.2 Load ranges
2.2.1:(ST1100-TI Load Range)
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
1.Maximum c.ontinuous combined load on +3.3V and +5V outputs shall not exceed 120W.
2.Maximum continuous total DC output power should not exceed 1100W.
3.Peak DC output power should not exceed 1200W for 12 second.
Min(optional)
0 0
0.15 0 0
Nom.
-
-
-
-
-
Max
25 22 92
0.3 3
Peak
Unit Volts Volts Volts Volts Volts
Unit Amps Amps Amps Amps Amps
2.2.2:(ST1300-TI Load Range)
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
1.Maximum continuous combined load on +3.3V and +5V outputs shall not exceed 120W.
2.Maximum continuous total DC output power should not exceed 1300W.
3.Peak DC output power should not exceed 1400W for 12 second.
Min(optional)
0 0
0.15 0 0
Nom.
-
-
-
-
-
Max
25 22
108
0.3 3
Peak
Unit Amps Amps Amps Amps Amps
02
Page 4
2.2.3:(ST1500-TI Load Range)
AC H ot
AC N eu tral
Power Supply
V out
V return
10uF 0.1uF
Load
Scope
AC Ground
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
1.Maximum c.ontinuous combined load on +3.3V and +5V outputs shall not exceed 120W.
2.Maximum continuous total DC output power should not exceed 1500W.
3.Peak DC output power should not exceed 1600W for 12 second.
Min(optional)
0 0
0.15 0 0
Nom.
-
-
-
-
-
Max
25 22
125
0.3 3
Peak
Unit Amps Amps Amps Amps Amps
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
2.3.2 Definition The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated
in the load impedance specified in figure 1. Ripple and noise are measured at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system loading. Ripple shall be measured under any condition of line voltage, output load, line frequency, operation temperature.
2.3.3 Ripple voltage test circuit
Ripple&Noise
50
50 120 120
50
Unit mVp-p mVp-p mVp-p mVp-p mVp-p
Figure 1. Ripple voltage test circuit
2.4 Overshoot
Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value,all outputs shall be within the regulation limit of section 2.0 before issuing the power good signal of section 5.0.
03
Page 5
2.5 Efficiency At 115Vac
load 10% 20% 50%
100%
Efficiency
90% 92% 94% 90%
PF
-
0.95
0.95
0.95
2.6 Remote ON/OFF control
When the logic level "PS-ON" is low, the DC outputs are to be enabled. When the logic level is high or open collector, the DC outputs are to be disabled.
3. PROTECTION
3.1 Over current protection
The power supply shall have current limit to prevent the +3.3V,+5V,and +12V outputs from exceeding the values shown in the following Table.If the current limits are exceeded the power supply shall shutdown and latch off.
Voltage +12V(ST1100-TI) +12V(ST1300-TI) +12V(ST1500-TI) +5V +3.3V
3.2 Over Temperature Protection
The power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition the PSU will shutdown. When the power supply temperature drops to within specifide limits,t he power supply shall restore power automatically. The OTP must have built in hysteresis such that the power supply will not oscillate on and off due to temperature condition.
3.3 Over-power protection
The power supply will be shutdown and latch off when output power within 110~130% of rated DC output. Note: Assurance machine can work at low voltage,full load won't damage machine.
3.4 Under voltage protection.
In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown state when +12V, +5V & +3.3V outputs under 85% of it's maximum value.
Over Current Limit (Iout limit) 100A minimum; 130A maximum 120A minimum; 150A maximum 130A minimum; 160A maximum 28A minimum; 48A maximum 28A minimum; 48A maximum
3.5 Over voltage protection
The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuity and reference.No single point fault shall be able to cause a sustained over voltage condition on any or all outputs.The supply shall provide latch-mode over voltage protection as defined in Table.
04
Page 6
output
+12 VDC
+5 VDC
+3.3 VDC
Minimum
13
5.5
3.6
Nominal
15
6 4
Maximum
17
7 5
Unit Volts Volts Volts
3.6 Short circuit
An output short circuit is defined as any output impedance of less than 0.1 ohms.The power supply shall shut down and latch off for shorting the +3.3 VDC,+5 VDC,or+12VDC rails to return or any other rail. Shorts between main output rails and +5VSB shall not cause any damage to the power supply. The power supply shall either shut down and latch off or fold back for shorting the negative rails.+5VSB must be capable of being shorted indefinitely,but when the short is removed, the power supply shall recover automatically or by cycling PS_ON#.The power supply shall be capable of withstanding a continuous short-circuit to the output without damage or overstress to the unit
3.7 No load operation
No damage or hazardous condition should occur with all the DC output connectors disconnected from the load. The power supply may latch into the shutdown state.
4. TIMING
4.1 Signal timing drawing
Figure 2. is a reference for signal timing for main power connector signals and rails.
Figure 2. PS-OK Timing Sequence (1)T3: Power good signal turn on delay time (100ms~500ms)
(2)T4: Power good signal turn off delay time (75%Load 1ms min) (3)T2: Rise time (0.1~20ms) (4)T6: Hold up time (75%Load 16ms Min)
4.2 Hold up time
When the power loss its input power, it shall maintain 16ms in regulation limit at normal input voltage and 75% load (AC:115V/60Hz or 230V/50Hz)
05
Page 7
5. ENVIRONMENT
5.1 Operation Temperature
0 to 50
Relative Humidity
10 to 90%, non-condensing
5.2 Shipping and Storage Temperature
Relative Humidity
-20 to 90 5 to 95%, non-condensing
5.3 Altitude Operating
Storage
2000m 3000m
6. SAFETY
6.1 Underwriters Laboratory (UL) recognition.
The power supply designed to meet UL 60950.
7. ELECTROMAGNETIC COMPATIBILITY (EMC)
7.1 ELECTROSTATIC DISCHARGE (ESD) - IEC 61000 – 4 - 22008
7.2 ELECTRICAL FAST TRANSIENT / BURST ( EFT/B) – IEC 61000 – 4 - 42012
7.3 SURGE – IEC 61000 – 4 - 52014
7.4 POWER FREQUENCY MAGNETIC FIELD – IEC 61000 – 4 - 82009
7.5 VOLTAGE DIPS – IEC 61000 – 4 - 112004
7.6 RADIATED SUSCEPTIBILTY – IEC 61000 – 4 – 32006+A12007+A2
2010(IEC 61000 – 4 – 3 2010)
7.7 CONDUCTED SUSCEPTIBILTY – IEC 61000 – 4 - 62008
(IEC 61000 – 4 – 6 2013)
7.8 VOLTAGE FLUCTATION - EN 61000 – 3 – 32008(EN 61000 – 3 – 32013)
7.9 EN61000-3-22006+A22009 harmonic current emissions.
(EN 61000 – 3 – 22014)
If applicable to sales in Europe, the power supply shall meet the requirements of EN 61000-3-2 Class D and the Guidelines for the Suppression of Harmonics in Appliances and General Use Equipment Class D for harmonic line current content at full-rated power.
7.10 EN550222010/AC2011 Class B Radio interference (CISPR 22).
7.11 ANSI C63.4-2009 / FCC Part 15 Subpart B / ICE-003 lssue 5 class B 115VAC
operation.
8. MTBF
8.1 MTBF (mean time between failures) calculation
The demonstrated MTBF shall be 100,000 hours of continuous operation at 25oC,at 80% load, and nominal line. The MTBF of the power supply be calculated in accordance with MIL-HDBK-217F. The DC FAN is not included.
9. Mechanical Specification
150 mm (W) × 86 mm (H) × 180mm (D)