• The combined power of +5V and +3.3V is 120W max.
• Peak currents may last up to 12 seconds with not more than one occurrence per minute.
* Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
10msec (minimum) at 80% of full load at 230Vac input.
2.3 POWER GOOD DELAY
100-500 msec.
0.0A
5.0A
10.0A
3.0A
22.0A
0.0A
12.0A
0.3A
0.0A
0.1A
0.1A
0.2A
0.2A
0.3A
0.3A
0.0A
0.0A
0.1A
0.5A
1.0A
2.5A
0.5A
2.0A
0.0A
2.4 POWER FAIL DELAY
1 msec.
2.5 TURN-ON DELAY TIME
2000 msec max.At nominal line full load.
2.6 TRANSIENT OVERSHOOT
DC output transient step sizes as below table:
Output voltage +5V +3.3V +12V
Max. step size 30% 30% 30%
Load-changing repetition rate of 10m seconds.
Load slew rated 1.0A/uS and capacitive load as below :
+5V +3.3V +12V -12V +5Vsb
10000uF 10000uF 10000uF 470uF 3300uF
03
Page 5
2.7 RISE TIME
20ms max at full load.
3. PROTECTION:
When OVP ,OPP or short protection is triggered, the main outputs will be latched off. The main
outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto recovery
when fault condition removed.