【2】50 %~100 %
(2) S/R=0.5A/us
(3) Frequency is 100Hz and 1 KHz
5V/9V/12V/15V/20V
5V/3A
9V/3A
12V/3A
15V/3A
20V/3A
5V±5%
9V±5%
12V±5%
15V±5%
20V±5%
DC CABLE
≦800
(
3Sec
5ms
275ms
275ms
5V ± 15%
9V ± 15%
12V ± 15%
15V ± 15%
20V ± 15%
MM
,18AWG)
02
3. Protection Characteristics:
ITEM CONDITION SPECIFICATION
3.1 Short Circuit Protection:
3.2 Over Voltage Protection:
3.3 Over Power P rotection:
3.4 Over Temperature Protection:
3.5 Over Current Protection:
When an internal fault occurs, or an external fault
is applied to the power supply, such that an
overload or short circuit is applied to the output,
the power supply shall shut down and enter
auto-recovery mode.
The adapter will enter into shut down that means
no output while over voltage happened at output
terminal that caused by internal fault, the outp ut
trip voltage shall not exceed 27 volts. That will be
return to normal state by AC reset.
When an internal fault occurs, or an external fault
is applied to the power supply, such that an
overload or short circuit is applied to the output,
the power supply shall shut down and enter
auto-recovery mode.
The power supply will enter into shut down while
the abnormal thermal rise occurs. That will be
return to normal state by AC reset.
115Vac, 230Vac / Full load
Shutdown and no damage
Shutdown and no damage
Shutdown and no damage
No fire, no smoke
Output current limit :
4A(MAX) for 5Vdc / 9Vdc
12Vdc / 15Vdc / 20Vdc
03
4. Environmental Characteristics:
ITEM CONDITION SPECIFICATION
4.1 Electric Fast Transients:
Refer to IEC61000-4-4
4.2 Lightning Surge:
Refer to IEC61000-4-5
4.3 Electron Static Discharge:
(Refer to IEC61000-4-2 Energy Storage
Capacitor 150pF; Discharge Resistor
330)
Impulse: 1kV applied to L,N
1kV applied differential mode
2kV applied common mode
Air Discharge: 8 KV
Contact Discharge: 4 KV
Normal operation shall be continued
Normal operation shall be continued
Normal operation shall be continued
Normal operation shall be continued
4.4 Cooling:
4.5 EMI: Adapter compl y with the following
national standards:
EMI Conducted Emission
EMI Radiated Emission
4.6 Safety conforming:
4.6.1 Department of Energy【DOE】
4.7LEAKAGE CURRENT:
4.8 Dielectric Strength: (Hi-Pot)
4.9 Temperature:
4.10 Humidity: Operating
Natural air cooling
1.Full Load
2. The power supply with internal filter can
Regulated by customer
264Vac / 50Hz
Between AC input and secondary applied
AC 1.5KV / test time 1 minute / cut off
current shall be less than 10mA
Operating
Storage
Storage
04
meet.
FCC PART 15J CLASS B
CISPR22 EN55022 CLASS B
VCCI LEVEL Π
Comply with DOE standard
0.25mA
0 to 40C
-20 to +80C
20% ~ 80%
10% ~ 90%
5. Mechanical Characteristics:
ITEM CONDITION SPECIFICATION
5.1 Dimension (Length x Width x Height): 92 X 77.3 X 25.4 mm
5.2 Adapter weight:
5.3 Input AC socket Type:
5.4 Vibration Test:
5.5 Acoustic Noise:
230g (typical)
IEC 320-C14 Type
(1)Non-operating, 0.01g
slopping to 0.02g
And maintain 0.02g
(2)PSD=3.13grms, 15 minutes/axis
Vibration duration:15minutes
(3)
Vibration waveform:Random
(4)
Force Direction X,Y,Z
(5)
(1)Position the microphone 30
centimeters above the x-y center of
the AC adapter
(2)Input voltage:110Vac/60Hz
2
/Hz at 5Hz
2
/Hz at 20Hz,
2
/Hz from 20Hz ~ 500Hz
220Vac/50Hz
Normal operation shall be continued.
The EUT < 30dB
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,and
(2) this device must accept any interference receivcd,
including interference that may cause undesired
operation.
05
NO. G11232611