Slim 25mm thickness design enables easy portability or hideaway placement
Up to 90% efficiency with Energy Star EPS 2.0 and ErP Lot 7 Tier 2 compliance
Includes 7 charger tips for maximum compatibility with most high-end laptops
Easy to install and use
Built-in multiple protection circuitry for maximum protection during operation
Installation
SilverStone AD120-T is a 120W AC to DC adapter intended for use with laptop & Intel
Small Form Factor motherboards or PCs. It is also perfect for use with SilverStone’s own Vital
series cases.
The AD120-T can reach up to 90% efficiency and is environmentally friendly as it complies with
Energy Star EPS 2.0 and ErP Lot 7 Tier 2 standards. There are 7 charger tips included so it is
compatible with most high-end laptops or devices that require external power supply.
With plethora of protection circuitry built-in, the AD120-T is an excellent choice for replacing or
upgrading any mobile or small form factor PC’s power source.
2.4 Output Voltage Ripple and Noise:
(0.1uF Ceramic Cap. and 35V 47uF
Aluminum Cap. Paralleled between
the end of output cable)
2.5 Turn-On Delay Time:
CONDITION
at constant voltage mode
at the output end of DC cable
100Vac, 240Vac / 0A~6.32A load
At 100Vac / 6.32A load, output voltage
shall remain regulation
SPECIFICATION
100Vac~240Vac
90Vac to 264Vac
47Hz to 63Hz ( ± 1Hz )
£ 1.8A
IEC61000-3-2
≧90%
≦ 0.15W
≦ 0.5W
Shall be less than the rating of
adapter critical component
(including rectifiers, fuse surge
and current limiting device)
SPECIFICATION
19V
0A to 6.32A
19V ± 5%
≦ 350mVp-p
≦ 3Sec
※ Meet:
(1)【ErP】
Energy-related
Products
(2)【DOE】
Department
of Energy
01
ITEM
2.6 Hold Up Time:
CONDITION
At 100Vac or 240Vac / 6.32A load,
output voltage shall remain regulation
SPECIFICATION
≧ 10ms
2.7 Rise Time:
2.8 Dynamic Load Change:
2.9 Overshoot:
At 100Vac / 6.32A load, DC output
rise time from 5% to 95% of Vo
(1) Output load step is:
【1】0 % ~ 50 %
【2】50 % ~ 100 %
(2)S/R=0.5A/us
(3)Frequency is 100Hz and 1KHz
100Vac, 240Vac / 0A and 6.32A load
3. Protection Characteristics:
ITEM
3.1 Short Circuit Protection:
3.2 Over Voltage Protection:
3.3 Over Power Protection:
CONDITION
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
The adapter will enter into shut down that
means no output while over voltage
happened at output terminal that caused by
internal fault, the output trip voltage shall
not exceed 29 volts. That will be return to
normal state by AC reset.
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
≦ 50ms
19V ± 10%
19V ± 10%
SPECIFICATION
Shutdown and no damage
Shutdown and no damage
Shutdown and no damage
3.4 Over Temperature Protection:
The power supply will enter into shut down
while the abnormal thermal rise occurs.
That will be return to normal state by
AC reset.
No fire, no smoke
02
4. Environmental Characteristics:
ITEM
4.1 Electric Fast Transients:
Refer to IEC61000-4-4
4.2 Lightning Surge:
Refer to IEC61000-4-5
4.3 Electron Static Discharge:
(Refer to IEC61000-4-2 Energy
Storage Capacitor
150pF; Discharge Resistor
330)
4.4 Cooling:
4.5 EMI: Adapter comply with
the following
national standards:
EMI Conducted Emission
EMI Radiated Emission
CONDITION
Impulse: ± 1kV applied to L,N
1kV applied differential mode
2kV applied common mode
Air Discharge: +/-15 KV
Contact Discharge: +/- 8 KV
Natural air cooling
1.Full Load
2. The power supply with internal filter
can meet.
SPECIFICATION
Normal operation shall be continued
Normal operation shall be continued
Normal operation shall be continued
--
FCC PART 15J CLASS B
CISPR22 EN55022 CLASS B
VCCI LEVEL Π
4.6 Safety conforming:
4.6.1 Energy-related Products【ErP】
Department of Energy【DOE】
4.7 Leakage Current:
4.8 Dielectric Strength: (Hi-Pot)
03
--
--
264Vac / 50Hz
Between AC input and secondary
applied AC 1.5KV / test time 1 minute /
cut off current shall be less than 10mA
Regulated by customer
Comply with ErP standard
Comply with DOE standard
≦ 0.25mA
--
ITEM
4.9 T emperature:
4.10 Humidity:
CONDITION
Operating
Storage
Operating
Storage
SPECIFICATION
0 to 40˚C
-20 to +80˚C
20% ~ 80%
10% ~ 90%
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,and
(2) this device must accept any interference receivcd,
including interference that may cause undesired
operation.
04
NO. G11231330
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.