SPECIFICATION
SilverStone
300W SFX Switching Power Supply
FSP300-60GHS
Meet 80 Plus Active PFC Circuit
Full Range Input Small Size
1. GENERAL DESCRIPTION AND SCOPE
This is the specification of Model UFSP300-60GHSU; AC-line powered switching power supply
with active PFC (Power Factor Correction) circuit, meet EN61000-3-2 and with Full Range Input
features.
The specification below is intended to describe as detailedly as possible the functions and
performance of the subject power supply. Any comment or additional requirements to this
specification from our customers will be highly appreciated and treated as a new target for
usto approach.
2. REFERENCE DOCUMENTS
The subject power supply will meet the EMI requirements and obtain main safety approvals
as following:
2.1 EMI REGULATORY
- FCC Part 15 Subpart J, Class ‘B’ 115 Vac operation.
- CISPR 22 Class ‘B’ 230 Vac operation.
1
Copyright © 2009 SilverStone Technology Co., Ltd. All Rights Reserved
Issued Date: 2009-January-19
2.2 SAFETY
- NEMKO EN 60950
- TUV EN60950 OR VDE EN60950
- CSA-C22.2 NO. 60950
- IEC 60950
- UL 60950
- CE :
EN 55022:1998+A1: 2000, Class B
EN 61000-3-2: 2000
EN 61000-3-3: 1995+A1: 2001
CISPR22: 1997+A1: 2000, Class B
AS/NZS CISPR 22: 2002, Class B
3. INPUT ELECTRICAL SPECIFICATIONS
3.1. AC INPUT
Parameter Min. Nom.
V
(115VAC)
in
V
(230VAC)
in
V
Frequency
in
90 115 135
180 230 265
47 -- 63
(1)
Max. Unit
VA C
VA C
HZ
Ϭ Nominal voltages for test purposes are considered to be within 1.0V of nominal.
3.2. INRUSH CURRENT
Maximum inrush current from power-on (with power on at any point on the AC sine) and
including, but not limited to, three line cycles, shall be limited to a level below the surge
rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter
components. Repetitive ON/OFF cycling of the AC input voltage should not damage the
power supply or cause the input fuse to blow.
rms
rms
2
Copyright © 2009 SilverStone Technology Co., Ltd. All Rights Reserved
Issued Date: 2009-January-19
3.3. INPUT LINENT & POWER FACTOR
(At Full load)
AC input
115V < 3.5Amps – rms
230V
3.4. EFFICIENCY
3.4.1 General
Under the load conditions defined in Table 1 and Table 2. The loading condition for testing
efficiency shown in Table 1 represents a fully loaded system. a ~ 50-60% (typical) loaded
system.and a ~ 20-30% (light) loaded system.
Table 1. Loading Table for Efficiency Measurement
Loading +12V1 +12V2 +5V +3.3V -12V +5Vsb
Full
Typical
Light
7.56
3.78
1.51
Input line current P.F.@ Full Load P.F.@ Pin=75W
< 2.0Amps – rms
> 0.95
> 0.9
>0.8
>0.75
300W (loading shown in Amps)
8.64
4.32
1.73
11.5
5.75
2.3
10.46
5.23
2.09
0.37
0.18
0.07
1.84
0.92
0.37
Table 2. Minimum Efficiency Vs Load
Loading Voltage
Full
load
Required Minimum Efficiency 115V 80% 81% 80%
Required Minimum Efficiency 230V 80% 81% 80%
Minimum Efficiency for test purposes are considered to be within ±1.0% of nominal.