SilverStone ST50F-ES, ST40F-ES, Essential Plus ST50F-ES, Essential Plus ST40F-ES Specifications

Page 1
High efficiency with 80Plus certification
24hour continuous power output with 40 C operating temperature
Class-leading single +12V rail
Multiple protection circuitry
Silent running 120mm fan with 18dBA
PCI-E 8pin and PCI-E 6pin connector support
ATX 12V 2.3 support
Power for everything you need
November, 2009
NO.G1121
ST50F-ES / ST40F-ES
Strider Essential Series
o
Page 2
SPECIFICATION
SilverStone Essential Plus ST50F-ES ST40F-ES
ATX12V 2.3 Switching Power Supply With Active PFC PS/2
01
This specification defines the performance characteristics of a single phase 500 and 400 watts, 5 output power supply. This specification also defines worldwide safety and electromagnetic compatibility requirements for the power supply which is intended for use in computer products.
Nominal Voltage
115-230 Vrms
2.1. Input Voltage
2.1.1 ST50F-ES
2.1.1 ST40F-ES
1.GENERSAL
2.INPUT CHARACTERISTICS
1.1. Scope
Voltage Variation Range
103.5 - 253 Vrms
Nominal Voltage
115-230 Vrms
Voltage Variation Range
103.5 - 253 Vrms
02
2.2 Input Frequency
2.3 Max. Input AC Current
2.4 Inrush Current
2.2.1 ST50F-ES
2.2.2 ST40F-ES
Strider Essential Series
Nominal Frequency
50-60 Hz
Frequency Variation Range
47 Hz to 63 Hz
Nominal Frequency
50-60 Hz
* The power supply must operate at above frequency with 103.5 - 253V ACrms input voltage range.
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range. The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
Frequency Variation Range
47 Hz to 63 Hz
2.3.1 ST50F-ES
Max. Input Current
6.5A
Measuring Range
103.5 - 253 Vrms
2.3.2 ST40F-ES
Max. Input Current
5.5A
Measuring Range
103.5 - 253 Vrms
Page 3
03
ST50F-ES, ST40F-ES provides an efficiency of >80% when measured at full load under 115V/60Hz and 230V/50Hz condition.
Maximum continuous total DC output power should not exceed 500W. Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 120W. Maximum combined load on +12V outputs shall not exceed 400W. When the 12V output is maximum rating, 5V must reach 3A, the output voltage
can be within the specification. When the 5V output is maximum rating, 12V output rating must reach 11A, the
output voltage can be within the specification.
Output Voltage
1. +5V 0.2A
2. +3.3V 0.1A
4. +12V
5. -12V
6. +5Vs
0.6A
0.0A
0.0A
20.0A
24.0A
34.0A
0.3A
2.5A
--
--
--
--
--
±5% ±5% ±5%
±10%
±5%
100mV 100mV 150mV 150mV 100mV
Load MIN
Peak Regulation
Range MAX
Ripple P-P Max
2.5 Efficiency
3.1 Normal Operation Output
3.1.1 ST50F-ES
3. OUTPUT CHARACTERISTICS
04
STRIDER ST1000STRIDER ST1000-NV
Strider Essential Series
Maximum continuous total DC output power should not exceed 400W. Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 120W. Maximum combined load on +12V outputs shall not exceed 300W. When the 12V output is maximum rating, 5V must reach 3A, the output voltage
can be within the specification. When the 5V output is maximum rating, 12V output rating must reach 9A, the
output voltage can be within the specification.
NOTE: Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.
The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active low signal that turns on the output power rails. When this is not pulled low by the system, or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply.
TTL level "H" 2.0 V - 5.25 V "L" 0.0 V – 1.0 V
Output Voltage
1. +5V 0.2A
2. +3.3V 0.1A
4. +12V
5. -12V
6. +5Vs
0.6A
0.0A
0.0A
20.0A
24.0A 25A
0.3A
2.5A
--
--
--
--
--
±5% ±5% ±5%
±10%
±5%
100mV 100mV 150mV 150mV 100mV
Load MIN
Peak Regulation
Range MAX
Ripple P-P Max
3.1.2 ST40F-ES
3.2 Remote On/Off Controlled mode
Page 4
05
3.3 Regulation
3.4 Rise Time
3.3.1 ST50F-ES
The cross regulation defined as follows, the output regulation should be within the specified range.
DC output rise time is less than 20 mS at nominal line and full load.
3.5 Hold-up Time
DC +5V output maintains at least 8mS after power off which hold within para
3.1 under 230V/50Hz condition.
3.6 5VSB
5VSB is requierd for the implementation of PS-ON described above. 5VSB is a standby voltage that may be used to power circuits that require power input during the powered-down state of all power rails. The 5 VSB pin should deliver 5V ± 5% at a minimum of 2.5 A for PC board circuits to operate. Conversely, PC board should draw no more than 2.5A maximum form this pin. This power may be used to operate circuits such as soft power control.
Load Light Load Typical Load Full Load
+5Vsb
0.47A
1.17A
2.33A
-12V
0.06A
0.14A
0.28A
+5V
2.50A
6.25A
12.49A
+3.3V
3.00A
7.49A
14.99A
+12V
6.22A
15.54A
31.08A
3.3.2 ST40F-ES
Load Light Load Typical Load Full Load
+5Vsb
0.46A
1.15A
2.29A
-12V
0.06A
0.14A
0.28A
+5V
2.46A
6.14A
12.28A
+3.3V
2.95A
7.37A
14.74A
+12V
4.59A
11.47A
22.93A
06
3.7 PG-OK
PG-OK is a power good signal and should be asserted high by power supply to indicate that the +5 VDC and +3.3 VDC outputs are above the under-voltage thresholds of the power supply. When this signal is asserted high, there should be sufficient mains energy stored by the converter to guarantee continuous power operation within specification. Conversely, when either the +5VDC or the +3.3VDC output voltage falls below the under
-voltage threshold, or when mains power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PG-OK should be deasserted to a low state. See Figure 1 for a representation of the timing characteristics of the PG-OK, PS-ON, and germane power rail signals.
3.8 3.3V Sense
A default 3.3V sense line should be implemented pin 13 of the connector.
Output +5V +12V +3.3V
-12V +5VS
Capacitive load (uF) 10,000 10,000 10,000 330 10,000
3.9 Capacitive Load
4.1 Input Protection
4. PROTECTION
The power supply should be able to power up and operate normally with the following capacitances simultaneously present on the DC outputs.
In primary circuit of the power supply , a protected fuse is inserted. Only internal fault of the power supply will cause the fuse blown. Any overload or short circuit at DC output will keep from fuse brown or fire hazard.
The +5V/+3.3V DC output are protected against the under voltage condition. Range value can't be exceed 3.3~3.7V at 5V terminal and 2.0~2.4V at 3.3V.
4.2 Output Protection
4.2.1 Under voltage protection
The +5V/+12V/+3.3V DC output are protected against the over voltage condition. Maximum value can't be over 6.5V at 5V terminal and 15.5V at 12V, 4.3V at 3.3V.
4.2.2 Over Voltage Protection
Strider Essential Series
Page 5
07
5. START STABILITY
6. ENVIRONMENTS
5.1 No Load Start
When power is applied to ST50F-ES & ST40F-ES with no load connected or under minimum load connected, neither damage to power supply nor hazards to users will occur.
5.2 Cold Start
6.1 Temperature and Humidity
6.2 Altitude
6.1.1 Operating
The power supply shall operate properly when first applied at normal input voltage and or so maximum load after 4 hours storage in 0 C environment.
The power supply can operate normally at any altitude between 0 to 10000 feet.
Temperature 0 to 40 C Relative Humidity 20 to 90 %
o
6.1.2 Storage
Temperature -40 to 70 C Relative Humidity 20 to 95 % noncondensing
o
o
The power supply can be used electronic circuit to limit the output current against exceeding 60% of surge output power or protected against excessive power delivery since short circuit of any output or over total power at high line.
4.2.3 Over Power Protection
Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will auto-recovery.
4.2.4 Short Circuit Protection
08
8. PRODUCT SAFETY
9. POWER GOOD SIGNAL
8.1 Safety Requirement
TUV, UL/c-UL,CB
8.2 Leakage Current
The AC leakage current is less than 3.5mA when the power supply connect to 253Vac/50Hz.
8.3 Insulation Resistance
The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 minute.
8.4 Dielectric Voltage Withstand
The power supply shall withstand for 1 minute without breakdown the application of a 60Hz 1500V AC voltage applied between both input line and chassis (20mA DC cut-off current). Main transformer shall similarly withstand 3000Vac applied between both primary and secondary windings for a minimum of one minute.
A TTL compatible signal for the purpose of initiating an orderly start-up procedure under normal input operating conditions. During power up, this signal is asserted ( low ) until +5V is under regulation and AC reaches min. line specification range. After all voltage are going appropriate level, the system may have a turn on delay of 100mS, but no greater than 500mS. During power off the signal should go to low level before +5V is out of regulation. The low level is 0 to 0.8V and high level is 4.75 to 5.25V. The " Power Good "signal can drive up to 6 standard TTL loads.
Strider Essential Series
7. CONDUCTED EMI
FCC, CE
6.3 Vibration and Shock
Sweep and resonance search for each of X,Y,Z, axis at the sweep. RATE of 1/OCTAVE/Min.
Frequency
5-55-10 Hz
Amplitude
0.35 mm
Duration
30 minutes
Page 6
09
* T1 : Turn on time ( 2 sec. Max.) * T2 : Rise time ( 20mS Max.) * T3 : Power good turn on delay time ( 100 < T3 < 500 mS ) * T4 : Switch on time (0.5 sec. Max.) * T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF * T6 : Power hold-up time ( 8 mS Min.) * Power on-off cycle :
Time Diagram
Figure 1
<
=
When the power supply is turned off for a minimum of 2.0 sec. and turn on again, the power good signal will be asserted.
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003 standard of class D, test at 230Vac 50Hz.
10. HARMONICS
The power supply with active power factor correction, and meet the EN61000-3-2 standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load.
150 mm (W) × 86 mm (H) × 140mm (D)
11. POWER FACTOR
12. MECHANICAL REQUIREMENTS
12.1 Physical Dimension
10
Strider Essential Series
12.2 Connectors
EPS 12V 8PIN connector
Signal Pin Pin Signal Yellow +12V Yellow +12V Yellow +12V Yellow +12V
5 6 7 8
1 COM Black 2 COM Black 3 COM Black 4 COM Black
M/B 24PIN connector
Signal Pin Pin Signal Orange +3.3V Orange +3.3Vsense Blue -12VDC Black COM Green PS-ON Black COM Black COM Black COM White N/C Red +5VDC Red +5VDC Red +5Vsense Red +5VDC Black COM
1 +3.3V 2 +3.3V 3 COM 4 +5VDC 5 COM 6 +5VDC 7 COM 8 PWRGOOD 9 5Vsb 10 +12V 11 +12V 12 +3.3V
Orange Orange Black Red Black Red Black Grey Purple Yellow Yellow Orange
13 13 14 15 16 17 18 19 20 21 22 22 23 24
ATX 12V 4PIN (4+4PIN EPS 12V in split mode)
Signal Pin Pin Signal Black GND Black GND
1 2
3 +12V Yellow 4 +12V Yellow
Page 7
11
4PIN peripheral connector (HDD) 4PIN floppy connector (FDD)
Signal Pin Pin Signal Yellow +12V Black COM Black COM Red +5VDC
1 2 3 4
1 +5VDC 2 COM 3 COM 4 +12V
Red Black Black Yellow
SATA connector
Signal Pin Orange +3.3V Black COM Red +5V Black COM Yellow +12V
5 4 3 2 1
8PIN PCI Express connector
Signal Pin Pin Signal Yellow +12V Yellow +12V Yellow +12V Black sense1 COM
1 2 3 4
5 COM 6 COM 7 COM 8 COM
Black Black Black Black
6PIN PCI Express connector
Signal Pin Pin Signal Yellow +12V Yellow +12V Yellow +12V
1 2 3
4 COM 5 COM 6 COM
Black Black Black
12
Strider Essential Series
Loading...