SilverStone ST50F-ES, ST40F-ES, Essential Plus ST50F-ES, Essential Plus ST40F-ES Specifications

High efficiency with 80Plus certification
24hour continuous power output with 40 C operating temperature
Class-leading single +12V rail
Multiple protection circuitry
Silent running 120mm fan with 18dBA
PCI-E 8pin and PCI-E 6pin connector support
ATX 12V 2.3 support
Power for everything you need
November, 2009
NO.G1121
ST50F-ES / ST40F-ES
Strider Essential Series
o
SPECIFICATION
SilverStone Essential Plus ST50F-ES ST40F-ES
ATX12V 2.3 Switching Power Supply With Active PFC PS/2
01
This specification defines the performance characteristics of a single phase 500 and 400 watts, 5 output power supply. This specification also defines worldwide safety and electromagnetic compatibility requirements for the power supply which is intended for use in computer products.
Nominal Voltage
115-230 Vrms
2.1. Input Voltage
2.1.1 ST50F-ES
2.1.1 ST40F-ES
1.GENERSAL
2.INPUT CHARACTERISTICS
1.1. Scope
Voltage Variation Range
103.5 - 253 Vrms
Nominal Voltage
115-230 Vrms
Voltage Variation Range
103.5 - 253 Vrms
02
2.2 Input Frequency
2.3 Max. Input AC Current
2.4 Inrush Current
2.2.1 ST50F-ES
2.2.2 ST40F-ES
Strider Essential Series
Nominal Frequency
50-60 Hz
Frequency Variation Range
47 Hz to 63 Hz
Nominal Frequency
50-60 Hz
* The power supply must operate at above frequency with 103.5 - 253V ACrms input voltage range.
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range. The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
Frequency Variation Range
47 Hz to 63 Hz
2.3.1 ST50F-ES
Max. Input Current
6.5A
Measuring Range
103.5 - 253 Vrms
2.3.2 ST40F-ES
Max. Input Current
5.5A
Measuring Range
103.5 - 253 Vrms
03
ST50F-ES, ST40F-ES provides an efficiency of >80% when measured at full load under 115V/60Hz and 230V/50Hz condition.
Maximum continuous total DC output power should not exceed 500W. Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 120W. Maximum combined load on +12V outputs shall not exceed 400W. When the 12V output is maximum rating, 5V must reach 3A, the output voltage
can be within the specification. When the 5V output is maximum rating, 12V output rating must reach 11A, the
output voltage can be within the specification.
Output Voltage
1. +5V 0.2A
2. +3.3V 0.1A
4. +12V
5. -12V
6. +5Vs
0.6A
0.0A
0.0A
20.0A
24.0A
34.0A
0.3A
2.5A
--
--
--
--
--
±5% ±5% ±5%
±10%
±5%
100mV 100mV 150mV 150mV 100mV
Load MIN
Peak Regulation
Range MAX
Ripple P-P Max
2.5 Efficiency
3.1 Normal Operation Output
3.1.1 ST50F-ES
3. OUTPUT CHARACTERISTICS
04
STRIDER ST1000STRIDER ST1000-NV
Strider Essential Series
Maximum continuous total DC output power should not exceed 400W. Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 120W. Maximum combined load on +12V outputs shall not exceed 300W. When the 12V output is maximum rating, 5V must reach 3A, the output voltage
can be within the specification. When the 5V output is maximum rating, 12V output rating must reach 9A, the
output voltage can be within the specification.
NOTE: Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.
The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active low signal that turns on the output power rails. When this is not pulled low by the system, or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply.
TTL level "H" 2.0 V - 5.25 V "L" 0.0 V – 1.0 V
Output Voltage
1. +5V 0.2A
2. +3.3V 0.1A
4. +12V
5. -12V
6. +5Vs
0.6A
0.0A
0.0A
20.0A
24.0A 25A
0.3A
2.5A
--
--
--
--
--
±5% ±5% ±5%
±10%
±5%
100mV 100mV 150mV 150mV 100mV
Load MIN
Peak Regulation
Range MAX
Ripple P-P Max
3.1.2 ST40F-ES