Silicon Graphics Rackable C1104-GP2, Rackable C1110-GP2 System User's Manual

Page 1
SGI® Rackable™ C1104-GP2 and C1110-GP2 System User Guide
007-6388-001
Page 2
COPYRIGHT
© 2014 Silicon Graphics International Corp. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission is granted to copy, distribute, or create derivative works from the contents of this electronic documentation in any manner, in whole or in part, without the prior written permission of SGI.
LIMITED RIGHTS LEGEND
The software described in this document is “commercial computer software” provided with restricted rights (except as to included open/free source) as specified in the FAR 52.227-19 and/or the DFAR 227.7202, or successive sections. Use beyond license provisions is a violation of worldwide intellectual property laws, treaties and conventions. This document is provided with limited rights as defined in 52.227-14.
The electronic (software) version of this document was developed at private expense; if acquired under an agreement with the USA government or any contractor thereto, it is acquired as “commercial computer software” subject to the provisions of its applicable license agreement, as specified in (a) 48 CFR
12.212 of the FAR; or, if acquired for Department of Defense units, (b) 48 CFR 227-7202 of the DoD FAR Supplement; or sections succeeding thereto. Contractor/manufacturer is SGI, 46600 Landing Parkway, Fremont, CA 94538.
TRADEMARKS AND ATTRIBUTIONS
Silicon Graphics, SGI, the SGI logo, Rackable, and Supportfolio are trademarks or registered trademarks of Silicon Graphics International Corp. in the United States and/or other countries worldwide.
Intel, Intel QuickPath Interconnect (QPI) and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. AMIBIOS is a registered trademark of American Megatrends Inc. in the United States and/or other countries worldwide. Fusion-MPT, Integrated RAID, MegaRAID, and LSI Logic are trademarks or registered trademarks of LSI Logic Corporation. HyperTransport is a licensed trademark of the HyperTransport Technology Consortium. InfiniBand is a registered trademark of the InfiniBand Trade Association. Internet Explorer and MS-DOS are registered trademarks of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds, used with permission by SGI. Novell and Novell Netware are registered trademarks of Novell Inc. PCIe and PCI-X are registered trademarks of PCI SIG. Phoenix and PhoenixBIOS are registered trademarks of Phoenix Technologies Ltd. Red Hat and all Red Hat-based trademarks are trademarks or registered trademarks of Red Hat, Inc. in the United States and other countries. SUSE LINUX and the SUSE logo are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
All other trademarks mentioned herein are the property of their respective owners.
Page 3
007-6388-001 iii
Record of Revision
Version Description
001 December, 2014
First release
Page 4
Page 5
007-6388-001 v
Contents
Record of Revision . . . . . . . . . . . . . . . . . . . . . . . iii
About This Guide . . . . . . . . . . . . . . . . . . . . . . . ix
Audience. . . . . . . . . . . . . . . . . . . . . . . . . . ix
Chapter Descriptions . . . . . . . . . . . . . . . . . . . . . . ix
Related Publications . . . . . . . . . . . . . . . . . . . . . . . x
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . xi
Product Support . . . . . . . . . . . . . . . . . . . . . . . . xi
Reader Comments . . . . . . . . . . . . . . . . . . . . . . . xii
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 1
Server Board Features . . . . . . . . . . . . . . . . . . . . . . 3
Processors . . . . . . . . . . . . . . . . . . . . . . . . 3
QPI Interconnect . . . . . . . . . . . . . . . . . . . . . . 3
Memory . . . . . . . . . . . . . . . . . . . . . . . . . 3
Serial ATA and Optional SAS . . . . . . . . . . . . . . . . . . . 4
PCI Express Expansion Slots . . . . . . . . . . . . . . . . . . . 4
Onboard Controllers/Ports . . . . . . . . . . . . . . . . . . . . 4
Onboard Graphics Controller . . . . . . . . . . . . . . . . . . . 4
IPMI . . . . . . . . . . . . . . . . . . . . . . . . . 4
Other Features . . . . . . . . . . . . . . . . . . . . . . . 5
Server Chassis Features . . . . . . . . . . . . . . . . . . . . . . 5
System Power . . . . . . . . . . . . . . . . . . . . . . . 5
Serial ATA Subsystems . . . . . . . . . . . . . . . . . . . . 5
Front Control Panel . . . . . . . . . . . . . . . . . . . . . . 5
Serverboard and PCIe Subsystem . . . . . . . . . . . . . . . . . . 6
PCIe Features . . . . . . . . . . . . . . . . . . . . . . 6
Cooling System . . . . . . . . . . . . . . . . . . . . . . . 7
Page 6
vi 007-6388-001
Contents
2 Server Installation . . . . . . . . . . . . . . . . . . . . . . . 9
Unpack the System . . . . . . . . . . . . . . . . . . . . . . . 9
Prepare for Setup . . . . . . . . . . . . . . . . . . . . . . 9
Choose a Setup Location . . . . . . . . . . . . . . . . . . . . 9
System Warnings and Precautions . . . . . . . . . . . . . . . . . . . 10
Server Precautions . . . . . . . . . . . . . . . . . . . . . . 11
Rack Mounting Considerations . . . . . . . . . . . . . . . . . . . . 11
Ambient Operating Temperature . . . . . . . . . . . . . . . . . . 11
Reduced Airflow . . . . . . . . . . . . . . . . . . . . . . 12
Mechanical Loading . . . . . . . . . . . . . . . . . . . . . . 12
Circuit Overloading . . . . . . . . . . . . . . . . . . . . . . 12
Reliable Ground . . . . . . . . . . . . . . . . . . . . . . . 12
Install the System into a Rack . . . . . . . . . . . . . . . . . . . . 12
Separate the Sections of the Rack Rails . . . . . . . . . . . . . . . . . 12
Inner Rail Extensions . . . . . . . . . . . . . . . . . . . . . 14
Installing the Inner Rail Extensions . . . . . . . . . . . . . . . . 14
Assembling the Outer Rails . . . . . . . . . . . . . . . . . . . . 15
Assembling the Outer Rails. . . . . . . . . . . . . . . . . . . 15
Attaching the Outer Rack Rails . . . . . . . . . . . . . . . . . . . 16
Using the Rail Locking Tabs . . . . . . . . . . . . . . . . . . 17
Install the Server in a Rack . . . . . . . . . . . . . . . . . . . . 18
Supply Power to the System . . . . . . . . . . . . . . . . . . 19
3 System Interface. . . . . . . . . . . . . . . . . . . . . . . . 21
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Control Panel Buttons . . . . . . . . . . . . . . . . . . . . . . 21
Control Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . 22
Power Fail LED . . . . . . . . . . . . . . . . . . . . . . . 23
UID LED . . . . . . . . . . . . . . . . . . . . . . . . 23
NIC1 . . . . . . . . . . . . . . . . . . . . . . . . . . 23
NIC2 . . . . . . . . . . . . . . . . . . . . . . . . . . 24
HDD . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Info LED. . . . . . . . . . . . . . . . . . . . . . . . . 24
Drive Carrier LEDs . . . . . . . . . . . . . . . . . . . . . . . 25
Page 7
Contents
007-6388-001 vii
4 System Safety . . . . . . . . . . . . . . . . . . . . . . . . 27
Electrical Safety Precautions . . . . . . . . . . . . . . . . . . . . 27
Serverboard Battery. . . . . . . . . . . . . . . . . . . . . . 28
ESD Precautions . . . . . . . . . . . . . . . . . . . . . . 28
Mainboard Replaceable Soldered-in Fuses . . . . . . . . . . . . . . . . 29
General Safety Precautions . . . . . . . . . . . . . . . . . . . . . 29
5 System and Serverboard Information . . . . . . . . . . . . . . . . . 31
Handling Circuit Boards and Drives . . . . . . . . . . . . . . . . . . 31
ESD Precautions . . . . . . . . . . . . . . . . . . . . . . 32
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . 32
System Rear I/O Ports . . . . . . . . . . . . . . . . . . . . . . 33
Serverboard Details . . . . . . . . . . . . . . . . . . . . . . 33
CPUs . . . . . . . . . . . . . . . . . . . . . . . . 34
Memory . . . . . . . . . . . . . . . . . . . . . . . 34
PCIe Expansion . . . . . . . . . . . . . . . . . . . . . 34
System Health Monitoring . . . . . . . . . . . . . . . . . . . 34
ACPI Features . . . . . . . . . . . . . . . . . . . . . . 35
Onboard I/O . . . . . . . . . . . . . . . . . . . . . . 35
Serverboard Dimensions . . . . . . . . . . . . . . . . . . . 35
Hard Drives (C1104-GP2 and C1110-GP2 Chassis) . . . . . . . . . . . . . . 37
Drive Configurations . . . . . . . . . . . . . . . . . . . . . 37
PCIe Expansion Cards . . . . . . . . . . . . . . . . . . . . . . 38
Power Supply Functional Rating . . . . . . . . . . . . . . . . . . 39
6 Basic Troubleshooting and Chassis Service . . . . . . . . . . . . . . . . 41
Basic Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . 41
If the System Does Not Power Up . . . . . . . . . . . . . . . . . . 41
System Powers Up But Will Not Boot . . . . . . . . . . . . . . . . . 42
No Video After System Power Up . . . . . . . . . . . . . . . . . . 42
Memory Errors . . . . . . . . . . . . . . . . . . . . . . . 42
Chassis Service Information. . . . . . . . . . . . . . . . . . . . . 43
Static-Sensitive Devices . . . . . . . . . . . . . . . . . . . . 43
Precautions . . . . . . . . . . . . . . . . . . . . . . . . 43
Page 8
viii 007-6388-001
Contents
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . 44
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . 44
Drive Bay Installation/Removal . . . . . . . . . . . . . . . . . . . . 44
Accessing the Drive Bays . . . . . . . . . . . . . . . . . . . . 44
Removing Hard Drives or Carriers from the Chassis . . . . . . . . . . . . . 45
The Hard Drive Backplane . . . . . . . . . . . . . . . . . . . 45
Disk Drive Installation . . . . . . . . . . . . . . . . . . . . . 45
Hard Drive Carrier Assembly Usage . . . . . . . . . . . . . . . . . 46
Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . 49
Power Supply Failure . . . . . . . . . . . . . . . . . . . . . 49
Removing/Replacing a Power Supply . . . . . . . . . . . . . . . . . 50
Removing the Power Supply . . . . . . . . . . . . . . . . . . 50
Installing a New Power Supply. . . . . . . . . . . . . . . . . . 50
Accessing the Inside of the Chassis . . . . . . . . . . . . . . . . . . . 52
System Fans . . . . . . . . . . . . . . . . . . . . . . . . . 52
System Fan Failure . . . . . . . . . . . . . . . . . . . . . . 52
Replacing System Fans . . . . . . . . . . . . . . . . . . . . . 53
Remove/Replace a Fan . . . . . . . . . . . . . . . . . . . . 53
Install/Replace a PCIe Expansion Card . . . . . . . . . . . . . . . . . . 57
Install/Replace a Low-profile PCIe Card . . . . . . . . . . . . . . . . 57
A BIOS Error Codes . . . . . . . . . . . . . . . . . . . . . . . 59
B System Operating and Regulatory Overview . . . . . . . . . . . . . . . . 61
Environmental Specifications . . . . . . . . . . . . . . . . . . . . 61
System Input Requirements . . . . . . . . . . . . . . . . . . . . . 62
Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . 62
Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . 63
Page 9
007-6388-001 ix
About This Guide
This guide provides an overview of the installation, architecture, general operation, and descriptions of the major components in the SGI
®
Rackable™ C1104-GP2/C1110-GP2 server. It also provides basic troubleshooting and maintenance information, BIOS error code information, and important safety and regulatory specifications. Note that the C1104-GP2 and C1110-GP2 are functionally the same, they differ only in drive slot capacity and size of drive used. The C1104-GP2 uses up to four 3.5-inch hard-disk or SSD drives; the C1110-GP2 servers use up to ten 2.5-inch hard-disk or SSD drives.
Audience
This guide is written for users of SGI Rackable C1104-GP2/C1110-GP2 server systems. It is written with the assumption that the reader has a good working knowledge of computers and computer systems. This guide may be useful to installers and system administrators looking for overview information on the server.
Chapter Descriptions
The following topics are covered in this guide:
Chapter 1, “Introduction”
Provides an overview of the server’s components.
Chapter 2, “Server Installation”
Provides a quick setup checklist to get the server operational.
Chapter 3, “System Interface”
Describes several LEDs on the control panel as well as others on the SATA drive carriers that keep you constantly informed of the overall status of the system as well as the activity and health of specific components.
Chapter 4, “System Safety”
Provides general system safety information.
Page 10
x 007-6388-001
Chapter 5, “System Severboard Information” Provides best practice procedures to work with a node board in a C1104-GP2/C1110-GP2 chassis, install memory DIMMs, PCIe expansion cards and hard disk drives.
Chapter 6, “Basic Troubleshooting and Chassis Service” Describes some basic steps required to troubleshoot your system. Additional sections in this chapter are intended to guide you through basic component remove and replace procedures.
Appendix A, “BIOS Error Codes,” Provides a brief listing of BIOS error code information.
Appendix B, “System Specifications,”
Describes system component, environmental, and compliance specifications.
Related Publications
The following SGI documents may be relevant to the use of your server:
SGI Foundation Software release notes
SGI Performance Suite release notes
SGI InfiniteStorage series documentation
Man pages
You can obtain SGI documentation, release notes, or man pages in the following ways:
Refer to the SGI Technical Publications Library at http://docs.sgi.com. Various formats are available. This library contains the most recent books and man pages.
Refer to the SGI Supportfolio™ webpage for release notes and other documents whose access require a support contract. See “Product Support” on page xi.
Page 11
:
007-6388-001 xi
Conventions
The following conventions are used throughout this document:
Product Support
SGI provides a comprehensive product support and maintenance program for its products. SGI also offers services to implement and integrate Linux applications in your environment.
Refer to http://www.sgi.com/support/
If you are in North America, contact the Technical Assistance Center at
+1 800 800 4SGI or contact your authorized service provider.
If you are outside North America, contact the SGI subsidiary or authorized distributor in
your country.
Convention Meaning
Command This fixed-space font denotes literal items such as commands, files,
routines, path names, signals, messages, and programming language structures.
variable The italic typeface denotes variable entries and words or concepts being
defined. Italic typeface is also used for book titles.
user input This bold fixed-space font denotes literal items that the user enters in
interactive sessions. Output is shown in nonbold, fixed-space font.
[ ] Brackets enclose optional portions of a command or directive line.
... Ellipses indicate that a preceding element can be repeated.
man page(x) Man page section identifiers appear in parentheses after man page names.
GUI element This font denotes the names of graphical user interface (GUI) elements such
as windows, screens, dialog boxes, menus, toolbars, icons, buttons, boxes, fields, and lists.
Page 12
xii 007-6388-001
Reader Comments
If you have comments about the technical accuracy, content, or organization of this document, contact SGI. Be sure to include the title and document number of the manual with your comments. (Online, the document number is located in the front matter of the manual. In printed manuals, the document number is located at the bottom of each page.)
You can contact SGI in any of the following ways:
Send e-mail to the following address: techpubs@sgi.com
Contact your customer service representative and ask that an incident be filed in the SGI incident tracking system:
http://www.sgi.com/support/supportcenters.html
SGI values your comments and will respond to them promptly.
Page 13
007-6388-001 1
Chapter 1
1. Introduction
Important: SGI Rackable server systems may sometimes require driver versions that are not included in the original operating system release. When required, SGI provides these drivers on an SGI Driver CD, which may ship with the system, or on the system disk (pre-installed in the factory). For more information on this topic check with your sales or service representative.
The Rackable C1104-GP2/C1110-GP2 server is a 1U rackmount system (see Figure 1-1 on page 2 for an example)
.
In addition to the serverboard and chassis, various hardware components may be included with the system, as listed:
Eight 4-cm chassis fans
One internal air shroud
Two passive 1U CPU heatsinks
Riser cards as follows:
One riser for two internal PCIe 3.0 x16 cards, (full-height cards)
One riser that supports a low-profile PCIe 3.0 x8 card (external-facing rear card) and
one internal PCIe 3.0 x8 low-profile card
Power cables for PCI cards
SATA/SAS drive accessories:
One SATA/SAS backplane
Four 3.5-inch hot-swap disk drive carriers (RAID must be enabled for hot swap)
or
Ten 2.5-inch hot-swap disk drive carriers (RAID must be enabled for hot swap)
Optional CD/DVD drive (with C1104-GP2 model only)
Two power supplies
One rackmount kit
Page 14
2 007-6388-001
1: Introduction
Tip: The Rackable C1110-GP2 (ten-drive chassis) server does not use an internal CD/DVD drive. Check with your SGI sales or service representative for information on optional external CD/DVD drive units. The 10-drive version of the server (C1110-GP2 is shown in Figure 1-1).
Figure 1-1 Rackable C1110-GP2 Server Front and Rear View Example
Note: Check with your SGI sales or service representative for the latest information on optional PCIe cards available for this server.
VGA Port
Ethernet LAN Ports
IPMI LAN Port
USB Ports
Control Panel
Disk Drives (10)
COM Port
UID
Power Supplies (2)
Front
Back
Page 15
Server Board Features
007-6388-001 3
Server Board Features
At the heart of the system is a dual-processor serverboard based on the Intel C612 platform controller hub (PCH) chipset and designed to provide maximum performance. The main features of the serverboard are described in the following subsections.
Processors
The serverboard supports two multi-core Intel® Xeon™ E5-2600(v3) Series processors. Each processor sits in an LGA 2011 socket and is interconnected via double Intel QuickPath Interconnect (QPI) link support; see the next subsection for more information on the QPI interconnects. Twelve DDR4 DIMM slots are available per CPU socket with three DIMM slots per channel. A direct media interface connects the node’s PCH ASIC to processor 1; while 40-lane Gen-3 PCIe interconnect lines link both processors directly to the motherboard LAN ports.
QPI Interconnect
Double QPI link pairs connect the two processors together on the motherboard, providing processor-controlled transfer bandwidths of up to 9.6 GB/second per QPI link between sockets.
Each QPI comprises two 20-lane point-to-point data links, one in each direction (full duplex), with a separate clock pair in each direction, for a total of 42 signals. Each signal is a differential pair, so the total number of pins is 84. The 20 data lanes are divided onto four “quadrants” of 5 lanes each. The basic unit of transfer is the 80-bit “flit”, which is transferred in two clock cycles (four 20 bit transfers, two per clock.) The 80-bit “flit” has 8 bits for error detection, 8 bits for “link-layer header” and 64 bits for “data”. QPI bandwidths are advertised by computing the transfer of 64 bits (8 bytes) of data every two clock cycles in each direction
Memory
The serverboard has 24 DIMM slots (twelve per processor) that support DDR4 2133/1866/1600/1333 MHz (L)RDIMMs. Up to three DIMMs per channel are supported.
Important: Use of three DIMMs per channel will limit the DIMMs to run at 1600 MHz maximum. Always use DIMMs that are the same type and speed for best performance.
Note also that memory speed support is dependent on the type of CPUs used on the mother board.
Page 16
4 007-6388-001
1: Introduction
Serial ATA and Optional SAS
The Intel PCH C612 is integrated into the system serverboard to provide an internal four-port or ten-port SATA disk subsystem. The drive ports are SATA 3.0 ports. The hot-swappable SATA drives are connected to a backplane that provides power, bus termination and configuration settings. Optional RAID 0, 1, 5, 6 and 10 are supported. Note that your operating system must have RAID support enabled to accommodate hot swapping of disk drives.
SAS RAID drive configurations require use of optional hardware ordered when the system is purchased. Check with your sales or service representative to obtain information on set-up procedures if your system did not come pre-configured with SATA or SAS RAID.
PCI Express Expansion Slots
The dual processor serverboard has two PCIe 3.0 x16 slots to support internal double-width PCIe cards. Another PCIe riser at the rear of the server supports one external-facing PCIe 3.0 x8 low-profile card and one internal low-profile PCIe 3.0 x8 card.
See the section “PCIe Expansion Cards” in Chapter 5 for more information on these topics.
Onboard Controllers/Ports
The color-coded I/O ports include (an internal COM header located on the serverboard), VGA (monitor) port, RJ45 LAN ports and two external USB 3.0 ports. A dedicated external IPMI LAN port is also included.
Onboard Graphics Controller
The dual-processor serverboard features an integrated Aspeed AST2400 video controller providing a DDR3 2D video graphics interface through the system VGA connector. The AST video controller in the 1U server features PCIe 1x support, advanced BMC features, low power consumption, high reliability and 1920 x 1200 60Hz display capability.
IPMI
IPMI (Intelligent Platform Management Interface) is a hardware-level interface specification that provides remote access, monitoring and administration for your SGI C1104-GP2/C1110-GP2
Page 17
Server Chassis Features
007-6388-001 5
server platforms. IPMI allows server administrators to view a server’s hardware status remotely, receive an alarm automatically if a failure occurs, and power cycle a system that is non-responsive.
Other Features
Other on-board features that promote system health include on-board voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
Server Chassis Features
The following subsections provide a general outline of the main features of the SGI Rackable C1104-GP2/C1110-GP2 server chassis.
System Power
The Rackable C1104-GP2/C1110-GP2 1U server chassis features a redundant power supply composed of two separate power modules. This power redundancy feature allows you to replace a failed power supply without shutting down the system. Note that each power supply provides up to 750 Watts of power to the system.
Serial ATA Subsystems
The server chassis supports up to four 3.5-in or ten 2.5-inch SATA drives. Chassis drives are SATA
3.0 6-Gb/second slots. RAID 0, 1, 5, 6 and 10 drives are hot-swappable units and are connected to a backplane that provides power and control. Note that the operating system you have installed must support RAID to enable the hot-swap capability of RAID drives. Certain RAID levels may require use of optional hardware or software to support RAIDed hard disk drives in the server. Use of certain RAID combinations may limit the number of drives in an array.
Front Control Panel
The control panel on the C1104-GP2/C1110-GP2 server provides you with system monitoring and control. LEDs that indicate system power, HDD activity, network activity, system overheat and a
Page 18
6 007-6388-001
1: Introduction
system overheat/fan-fail/ UID LED. A main power button and a system reset button are also included.
Serverboard and PCIe Subsystem
The C1104-GP2/C1110-GP2 server chassis is an ATX form factor chassis designed to be used in a 1U rackmount configuration. The serverboard’s I/O backplane supports up to three standard size (double-width) and one half-height PCIe cards which can offer optional computing solutions. A 15-pin VGA port, two USB 3.0 ports, Gigabit LAN ports and a dedicated RJ-45 IPMI LAN port are also supported.
Important: Check with your SGI sales or service representative prior to using any PCIe device not sourced from the SGI factory or documented by SGI as a supported option.
Figure 1-2 on page 7 shows a general block diagram of the C1104-GP2/C1110-GP2 server’s
processor and I/O chipset.
Cooling System
The 1U server chassis has a cooling design that includes ten internal 4-cm counter-rotating Pulse Width Modulated (PWM) system cooling fans located in the chassis. An air shroud channels the airflow from the system fans to efficiently cool the processor and PCIe areas of the system. Each power supply module also includes an internal cooling fan. All chassis and power supply fans operate continuously.
Page 19
Server Chassis Features
007-6388-001 7
Figure 1-2 Processor, Memory and I/O Chipset System Block Diagram
Page 20
Page 21
007-6388-001 9
Chapter 2
2. Server Installation
This chapter provides a quick setup checklist to get the SGI Rackable C1104-GP2/C1110-GP2 operational. If your system came already mounted in a rack, you can skip the rack installation procedures.
Unpack the System
Inspect the shipping container that the C1104-GP2/C1110-GP2 was shipped in and note if it was damaged in any way. If the server shows damage, file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack that supports the weight, power requirements, and environmental requirements of the C1104-GP2/C1110-GP2 server. It should be situated in a clean, dust-free environment that is well ventilated. Avoid areas where heat, electrical noise, and electromagnetic fields are generated. Place the server rack near a grounded power outlet. Refer also to “System Warnings and Precautions” on page 10.
Prepare for Setup
The shipping container should include two sets of rail assemblies, two rail mounting brackets and the mounting screws that you will use to install the system into a rack. Note that the inner rails should already be attached to the server. Read this section in its entirety before you begin the installation procedure.
Choose a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. This clearance may vary depending on the type of rack and installation site chosen. This product is for installation only in an (IEC 60950) Restricted Access
Page 22
10 007-6388-001
2: Server Installation
Location - dedicated equipment rooms, service closets and labs, etc. See also, “Regulatory
Compliance” in Appendix B.
System Warnings and Precautions
Warning: The SGI Rackable C1104-GP2/C1110-GP2 server weighs up to 34.1 lbs (15.5
kg). Always use proper lifting techniques when you move the server. Always get the assistance of another qualified person and/or mechanical lift device when you install the sever. Failure to do so may result in serious personal injury or damage to the equipment.
Warning: Extend the leveling jacks on the bottom of the rack to the floor with the full
weight of the rack resting on them. Failure to do so can result in serious injury or death.
Warning: Attach stabilizers to the rack in single rack installations. Failure to do so can
result in serious injury or death. Couple racks together in multiple rack installations. Failure to do so can result in serious injury or death.
Warning: Be sure the rack is stable before extending a component from the rack. Failure
to do so can result in serious injury or death.
Warning: Extend only one rack component at a time. Extending two or more components
simultaneously may cause the rack to tip over and result in serious injury or death.
!!!!!
Page 23
System Warnings and Precautions
007-6388-001 11
Figure 2-1 Slide/Rail Equipment Usage Caution
Page 24
12 007-6388-001
2: Server Installation
Server Precautions
Review the electrical and general safety precautions.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components in the bottom of the rack first, and then work up.
Add a regulating uninterruptible power supply (UPS) to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure.
Allow the hot-pluggable disk drives and power supply modules to cool before touching.
Always keep the rack’s front door and all panels and components on the servers closed when not servicing to maintain proper cooling.
The server is not considered suitable for visual display work place devices under the German government ordinance for work with visual display units.
Rack Mounting Considerations
Use the guidelines provided in the following subsections to properly install the server in a rack.
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (
35º C or 95º F).
Important: Certain system configurations using higher-wattage processors and PCIe option cards may require the maximum rated ambient temperature of the operational environment be 30º C (86º F) or lower. Altitude of operation can also affect required ambient air temperatures, see
Table B-1 on page 61. Check with your SGI sales or service representative for additional
information on this topic.
Page 25
Install the System into a Rack
007-6388-001 13
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading. Racks should generally be filled with equipment from the bottom up.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on over-current protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (for example, the use of power strips, and so on).
Install the System into a Rack
This section provides information on installing the C1104-GP2/C1110-GP2 into a rack. If the system has already been mounted into a rack, refer to “Supply Power to the System” on page 19. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Note that this system’s rail kit is designed to fit a rack between 26-in and 33.5-in deep.
Separate the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit.
Page 26
14 007-6388-001
2: Server Installation
Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Note that the inner rail may be pre-installed on the server by the SGI factory making separation steps unnecessary.
To separate the inner and outer rails, perform the following steps:
1. Locate the rail assembly in the chassis packaging as shown in Figure 2-2.
2. Extend the rail assembly by pulling it outward.
3. Press the quick-release tab
4. Separate the inner rail from the outer rail assembly.
Figure 2-2 Separating the System Rack Rail Components
L_min=
638.3(25.1") (OUTER RAIL)
L_min=(
786.4)(31")
L_max=
840.0(33.0") (OUTER RAIL)
(
1538.8)(60.6") (INNER RAIL)
Screw_M5.0
L_max=
840.0(33.0") (OUTER RAIL)
INNER RAIL_FRONT
INNER RAIL_BACK
Page 27
Install the System into a Rack
007-6388-001 15
Inner Rail Extensions
The chassis includes a set of inner rack rails in two sections:
inner rails
inner rail extensions
The inner rails are pre-attached to the server chassis and do not interfere with normal use of the system if you decide not to install it into a server rack. Attaching the inner rail extensions to the inner rails stabilizes the chassis within the rack is described in the following subsection.
Installing the Inner Rail Extensions
1. Place the inner rail extensions over the pre-attached inner rails which are attached to the side
of the chassis. Align the hooks of the inner rail with the rail extension holes. Make sure the extension faces “outward” just like the inner rail, reference Figure 2-3.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis to the rails with screws.
4. Repeat steps 1-3 for the other inner rail extension.
Figure 2-3 Rail to Server Chassis Attachment Example
Page 28
16 007-6388-001
2: Server Installation
Assembling the Outer Rails
Each outer rail is in two sections that must be assembled before mounting on to the rack.
Assembling the Outer Rails
1. Identify the left and right outer rails by examining the ends, which bend outward.
2. Slide the front section of the outer rail into the rear section of the outer rail.
3. The assembly should look similar to the example in Figure 2-4 on page 16.
Figure 2-4 Outer Rail Assembly Example
Attaching the Outer Rack Rails
Outer rails attach to the rack and hold the chassis in place. They extend between 26.5 and 36.4 inches.
1. Measure the depth of the rack (distance from the front rail to the rear rail) to ensure it complies with the limitations listed.
2. Adjust the outer rails to the proper length to fit within the rack. See the placement example in
Figure 2-5 on page 17.
Page 29
Install the System into a Rack
007-6388-001 17
3. Hang the hooks of the front of the outer rail onto the slots on the front of the rack. Use
screws to secure the outer rails to the rack.
4. Pull out and adjust both the short and long brackets to the proper distance so that the rail can
fit snugly into the rack, reference Figure 2-6 on page 19.
5. Hang the hooks of rear portion of the outer rail into the slots on the rear of the rack. Secure
the long bracket to the rear side of the outer rail with the screws provided.
6. Repeat the previous steps to properly install the left outer rail.
Figure 2-5 Outer Rack Rail Assembly/Placement Example
Page 30
18 007-6388-001
2: Server Installation
Using the Rail Locking Tabs
Both chassis rails have a locking tab, which serves two functions:
The tabs can lock the server into place when installed and pushed fully into the rack, (its normal operating position).
The tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when pulled out for servicing. Depress both tabs at the same time to fully remove the server from its rail mounting and extract it from the rack.
Install the Server in a Rack
Warning: The SGI Rackable C1104-GP2/C1110-GP2 server weighs up to 34.1 lbs (15.5
kg) Always use proper lifting techniques when your move the server. Always get the assistance of another qualified person and/or a mechanical lifting device when you install the sever. Failure to do so may result in serious personal injury or damage to the equipment.
1. Extend the outer rails on either side of the rack rail assembly.
2. Align the inner rails of the chassis with the outer rails on the rack, see Figure 2-6.
!
Page 31
Install the System into a Rack
007-6388-001 19
Figure 2-6 Installing the Server in the Rack
3. Slide the inner rails into the outer rails, keeping the pressure even on both sides. When the
chassis has been pushed completely into the rack, it should click into the locked position.
4. Optional screws are recommended to secure and hold the front of the chassis to the rack.
Supply Power to the System
Connect the power cords from the power supply modules into a power strip or power distribution unit (PDU) within the rack. An optionally available uninterruptible power supply (UPS) can ensure continued operation in case of a failure of the regular power source.
Page 32
20 007-6388-001
2: Server Installation
After all power connections are verified, push the power-on button on the front of the server when you wish to power on the unit.
Page 33
007-6388-001 21
Chapter 3
3. System Interface
Overview
There are a number of LEDs on the front control panel as well as others on the drive carriers and power supplies to keep you constantly informed of the overall status of the system. Figure 3-1 shows an example of the C1104-GP2 front panel. The control panel LEDs provide constant information on the system and on the overall health of major system components. Figure 3-2 shows a closer view of the control and status panel on the C1104-GP2.
Figure 3-1 C1104-GP2 Server Front Panel Example
Figure 3-2 Control Panel Indicator Components Example
Note: The status indicators and control buttons on the (ten drive) C1110-GP2 server’s control panel are placed (configured) differently, but offer the same functional control and information.
Server control/
status panel
3.5” Disk Drives (4)
Page 34
22 007-6388-001
3: System Interface
Control Panel Buttons
In addition to monitoring the activity and health of specific components using LEDs, the system uses two buttons located on the front of the chassis: a reset button and a power on/off button. Use the reset button to reboot the system as shown in Figure 3-3.
Figure 3-3 System Reset Button
Figure 3-4 shows the main power button, which is used to apply or turn off the main system power.
Turning off system power with this button removes the main power but keeps standby power supplied to the system.
Figure 3-4 System Power On Button
Page 35
Control Panel LEDs
007-6388-001 23
Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated or flashing and any corrective action you may need to take.
Power Fail LED
The power fail LED indicates a power supply module has failed as shown in Figure 3-5. The second power supply module will take the load and keep the system running but the failed module will need to be replaced as soon as possible. Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally.
Figure 3-5 Power Fail LED Example
UID LED
When the UID LED flashes (shown in Figure 3-6), it indicates a remote activation of the UID. The “blue light” function (UID) of this LED is used to identify a specific server in large racks filled with equipment. When activated locally the LED stays on solid blue. When activated through the system software the “blue light” will remain on until shut down by the administrator. There is a UID indicator on both the front and rear of the server.
Figure 3-6 UID LED Example
NIC1
When flashing, the NIC1 LED indicates network activity on the LAN1 port (see Figure 3-7).
Page 36
24 007-6388-001
3: System Interface
Figure 3-7 LAN1 Network Activity NIC1 LED Example
NIC2
When flashing, the NIC2 LED indicates network activity on the LAN2 port (see Figure 3-8).
Figure 3-8 LAN2 Network Activity NIC2 LED Example
HDD
The HDD LED indicates hard drive activity when flashing (see Figure 3-9).
Figure 3-9 Hard Drive Activity LED Example
Info LED
The info LED can indicate multiple states that may require attention. An example LED designation is shown in Figure 3-10. This LED has several states:
If the LED shows a solid red it indicates an overheat condition - check the environmental temperature and look for “cable congestion” or other obstructions that might impede air flow to the server.
1
2
Page 37
Drive Carrier LEDs
007-6388-001 25
A slow red blink indicates a power failure - check the function of the system power supplies
at the back of the unit.
A fast red blink indicates a fan failure - check for a failed cooling fan and replace as soon as
possible.
Figure 3-10 Overheat/Fan Fail/Info LED Example
Drive Carrier LEDs
The system hard disk drives each have two LEDs, that function as listed in the following two paragraphs:
Green: When illuminated, the green LED on the drive carrier indicates drive activity. A
connection to the drive backplane enables this LED to blink on and off when that particular drive is being accessed. Please refer to Chapter 6 for instructions on replacing failed drives.
Red: When this LED is flashing it indicates that a RAID drive is rebuilding. A solidly lit red
LED indicates a drive failure. If the drives fails, you should be notified by your system management software. Refer to Chapter 6 for instructions on replacing failed drives.
Page 38
Page 39
007-6388-001 27
Chapter 4
4. System Safety
This chapter describes basic safety precautions when using the server.
Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm and the Rackable C1104-GP2/C1110-GP2 system from damage, as follows:
Be aware of the locations of the power on/off switch on the chassis as well as the room's
emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or installing main
system components, such as the memory modules and disk drives. When disconnecting power, you should first power down the operating system and then unplug the power cords. The unit can have more than one power supply cord. Disconnect two power supply cords before servicing to avoid electrical shock.
When working around exposed electrical circuits, another person who is familiar with the
power-off controls should be nearby to switch off the power if necessary.
Use only one hand when working with powered-on electrical equipment. This is to avoid
making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection from electrical
shock. Instead, use rubber mats that have been specifically designed as electrical insulators.
The power supply power cords must include a grounding plug and must be plugged into
grounded electrical outlets or power distribution unit (PDUs).
Page 40
28 007-6388-001
4: System Safety
Serverboard Battery
Caution: There is a danger of explosion if an onboard battery is installed upside down, which will reverse its polarities (see the example in Figure 4-1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Check with your service representative if you have any questions.
Figure 4-1 Installing the Onboard Battery Example
Important: Handle used batteries carefully and do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Dispose of used batteries according to the manufacturer's instructions and in compliance with the regulations set up by your local hazardous waste management agency.
ESD Precautions
Caution: This server contains electronic components and printed circuit boards which are susceptible to electrostatic discharge (ESD) damage. ESD is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards.
!
!
Page 41
General Safety Precautions
007-6388-001 29
The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD:
Use a grounded wrist strap designed to prevent static discharge.
Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for
use.
Touch a grounded metal object before removing the board from the antistatic bag.
Do not let components or PCBs come into contact with your clothing, which may retain a
charge even if you are wearing a wrist strap.
Handle a board by its edges only; do not touch its components, peripheral chips, memory
modules or contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard and peripherals back into their anti-static bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent conductivity
between the power supply, the case, the mounting fasteners and the serverboard.
Mainboard Replaceable Soldered-in Fuses
Important: If your system comes with self-resetting PTC (Positive Temperature Coefficient) fuses on the serverboard, they must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact your technical support organization for details and support.
General Safety Precautions
Follow these rules to ensure general safety:
Keep the area around the C1104-GP2/C1110-GP2 systems clean and free of clutter.
The Rackable C1104-GP2/C1110-GP2 system can weigh approximately 34.1 lbs (15.5 kg.)
when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.
Page 42
30 007-6388-001
4: System Safety
Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on.
While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.
After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made.
Page 43
007-6388-001 31
Chapter 5
5. System and Serverboard Information
This chapter includes best practice procedures to work with a node board in the SGI Rackable C1104-GP2/C1110-GP2 chassis and understand the system PCIe expansion cards and hard disk drives. Use the information in Chapter 6 to troubleshoot your server and add, remove, or replace system components.
A layout and quick reference chart is included in this chapter for your reference.
Some software products are protected with software license keys derived from the Media Access Control (MAC) Ethernet address. If your system requires the replacement of a node board, the MAC Ethernet address changes. If you are using such a product, you or your service representative must request a new license key after replacement of a node board. Contact your local customer support office:
http://www.sgi.com/support/supportcenters.html
Caution: Install the chassis cover after you have completed accessing the components inside the server to maintain proper airflow and cooling for the system.
Handling Circuit Boards and Drives
Caution: Electrostatic discharge (ESD) can damage electrostatic-sensitive devices inside the C1104-GP2/C1110-GP2 server. Use the ESD precautions described below when you handle printed circuit boards or other components in the system. The following measures are generally sufficient to protect your equipment from electro-static discharge.
!
!
Page 44
32 007-6388-001
5: System and Serverboard Information
ESD Precautions
Use a grounded wrist strap designed to prevent electrostatic discharge.
Touch a grounded metal object before removing any board from its antistatic bag.
Handle each printed circuit board (PCB) by the edges; do not touch the components, peripheral chips, memory modules, or gold contacts on the PCB.
When handling chips or modules, avoid touching the pins.
Store PCIe cards, or other boards and components in antistatic bags when not in use.
Make sure your computer chassis provides a conductive path between the power supply, the case, the mounting fasteners, and the node board to chassis ground.
Unpacking
Caution: System options are shipped in anti-static packaging to avoid electrostatic discharge damage. Be sure to use ESD precautions when you unpack upgrade or replacement components for the C1104-GP2/C1110-GP2 server. Failure to do so can result in damage to the equipment.
!
Page 45
System Rear I/O Ports
007-6388-001 33
System Rear I/O Ports
The rear external system I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-1 below for locations of the various I/O ports on the C1104-GP2/C1110-GP2.
Table 5- 1 identifies the functions of each of the I/O ports on the backpanel.
Figure 5-1 I/O Port Locations Example
Table 5 - 1 System Backpanel I/O Port Functions
Serverboard Details
The 1U C1104-GP2/C1110-GP2 system chassis has one node board. The C1104-GP2/C1110-GP2 serverboard is configured with two processors. When configured with two processors, the following rules apply:
Both processor sockets must have identical revisions, core voltage, and bus/core speed.
The stepping between the processors on the board must be identical.
1. USB 3.0 port 0
2. USB 3.0 port 1
3. Dedicated RJ-45 IPMI LAN port
4. RJ-45 Ethernet LAN ports (1G-bit)
5. Com port (Serial)
6. VGA port
7. UID switch/LED
VGA Port
Ethernet LAN Ports
IPMI LAN Port
USB Ports
COM Port
UID
Power Supplies (2)
Page 46
34 007-6388-001
5: System and Serverboard Information
See Figure 5-2 on page 36 for CPU locations on the serverboard - note that the drawing is not to scale.
CPUs
The Intel PCH C612 chipset is used on the system serverboard.
Memory
Twenty four DIMM slots supporting 2133/1866/1600 MHz registered DDR4 ECC SDRAM.
Note: Check with your authorized sales/service representative for installation of approved DIMM types.
PCIe Expansion and PCIe Cards
The system accepts two full height full-length internal x16 PCIe cards and two low-profile cards at the rear of the system as follows:
One rear-accessible PCIe Gen 3.0 x8 low-profile card (in x16 slot)
One internal PCIe Gen 3.0 x8 low-profile card
Note: PCIe types supported are limited, check with your sales or support representative for
more information.
System Health Monitoring
Onboard voltage monitors
Fan status monitor with firmware/software on/off and speed control
Watch Dog
Environmental temperature monitoring via BIOS
Power-up mode control for recovery from AC power loss
System resource alert (via included utility program)
Auto-switching voltage regulator for each CPU core
CPU thermal trip support
Page 47
System Rear I/O Ports
007-6388-001 35
I2C temperature sensing logic
Chassis intrusion detection
ACPI Features
Slow blinking LED for suspend state indicator
BIOS support for USB keyboard
Wake-On-LAN (WOL)
Internal/external modem ring-on
16 MB SPI AMIBIOS® SM Flash UEFI BIOS
Hardware BIOS Virus protection
Onboard I/O
Drive Configurations include:
Four 3.5-inch disk drive bays supported by an on-chip SATA controller (RAID 0, 1, 5, 6
and 10 are supported)
Ten 2.5-inch disk drive bays supported by an on-chip SATA controller (RAID 0, 1, 5, 6
and 10 are supported)
Two (2) USB (Universal Serial Bus 3.0) ports (rear [external] type A)
RJ-45 LAN ports supported by an on-board Intel® Ethernet controller
A dedicated (RJ-45) IPMI LAN port
One VGA port supported by an Aspeed 2400 graphics controller (with DDR3 memory)
Serverboard Dimensions
Proprietary board format is: 19.7" x 9.2" (500.4 mm x 233.7 mm).
Page 48
36 007-6388-001
5: System and Serverboard Information
Figure 5-2 Node Board Layout Example (Not to Scale)
IPMI CODE
BIOS LICENSE
BAR CODE
JF2
L996
JTPM1
PSU2
PSU1
JUIDB2
LED1
JF1
JPME2
DAT
JWD1
JPB1
JPG1
FAN1
FAN8
FAN6
FAN7
FAN3
FAN2
I-SGPIO2
JIPMB1
LED_C1
LED_F3
LED_G1
BMC_HB_LED1
LED_B3
LED_B2
LED_B1
LED_A3
LED_A2
LED_A1
SP1
S-UM10
S-UM7
JSD2
JBT1
JBAT1
PLD1
JPP1
JPP0
JITP1
X10DRU-i+
Rev. 1.01
USB 2 (3.0)
I-SATA5
I-SATA0~3
SXB3C
SXB3B
SXB3A
SXB2
SXB1C
SXB1B
GPU PWR2
USB 3/4
(3.0)
TPM/PORT80
SXB1A
P2-DIMMF2
P2-DIMMF3
P2-DIMME1
P2-DIMME2
P2-DIMME3
P2-DIMMF1
P2-DIMMG1
P2-DIMMG2
P2-DIMMG3
P2-DIMMH1
P2-DIMMH2
P2-DIMMH3
CPU2
I-SATA4
CPU2_
PORT2A
CPU2_
PORT2C
CPU2_PORT1
CPU2_PORT3A
CPU1
P1-DIMMC1
P1-DIMMC2
P1-DIMMC3
P1-DIMMD1
P1-DIMMD3
P1-DIMMD2
CPU1_PORT2C
CPU1_PORT2A
CPU1_PORT3C
CPU1_PORT3A
S-SATA0~3
COM1
CPU1_PORT1
P1-DIMMA1
P1-DIMMA2
P1-DIMMA3
P1-DIMMB1
P1-DIMMB2
P1-DIMMB3
BP PWR2
GPU PWR1
VGA
IPMI_LAN
UID
USB 0/1(3.0)
BP PWR1
JSD1
LED_C2
LED_C3
LED_D1
LED_D2
LED_D3
FAN5
LED_G2
LED_G3
LED_H1
LED_H2
LED_H3
LED_F2
LED_F1
LED_E3
LED_E2
LED_E1
LED2
CPU2_PORT0
HDD_LED1
GPU PWR3
GPU PWR4
L995
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
PCH
BMC
BIOS
CPU2_PORT3C
CLK
JL1
FAN4
JPW21
JPW19
JPW22
JPW23
JGPW1
SXB3_1
SXB3_2
JGPW2
JGPW3
JGPW4
Page 49
Hard Drives (C1104-GP2 and C1110-GP2 Chassis)
007-6388-001 37
Hard Drives (C1104-GP2 and C1110-GP2 Chassis)
The C1104-GP2 chassis option supports a maximum of four 3.5-inch hard disk drives, see
Figure 5-3 for an example. Install the drives from left to right starting in the left bay.
The C1110-GP2 chassis option supports a maximum of ten 2.5-inch hard drives, see Figure 5-4 for an example. Install drives from left to right starting in the lower-left bay.
All drive bays must be populated with either a drive or a “drive blank” to maintain system thermals. Failure to follow this guideline may cause system overheating and thermal shutdown of the unit.
Important: The operating system you use must have RAID support to enable the hot-swap capability and RAID functions of the drives.
Figure 5-3 C1104-GP2 System Four-Drive Locations Example
Figure 5-4 C1110-GP2 System Ten-Drive Locations Example
Drive Configurations
The disk drive RAID configurations supported in the Rackable C1104-GP2/C1110-GP2 servers are outlined in the paragraphs that follow. Note that some configurations are dependent on use of optional hardware to support RAID configurations.
Page 50
38 007-6388-001
5: System and Serverboard Information
The supported disk drive configurations are as follows:
JBOD This non-RAID disk array supports any number of drives installed in the server. The operating system is placed on the disk drive in location 0 (system disk). All other drives are data drives.
RAID 0 Disk striping without parity, supports any even-number of drives installed. Note that all drives must be the same type, speed and capacity. The operating system will be striped across all drives in the system. This configuration is not recommended.
RAID 1 Disk “mirroring”, supports exactly two drives. The two drives represent one RAID 1 logical drive. The operating system will be installed on the drives located in Drive positions 0 and 1.
Note that both drives 0 and 1 must be of the same type, speed and capacity.
RAID 5 Disk striping with distributed parity - each RAID 5 drive has its own parity resource. Up to 20% of disk space on each drive must be devoted to parity information. A minimum of three drives are required for a functional RAID 5 array. A single drive failure will result in decreased performance until the damaged drive is replaced and the parity rebuild is complete. RAID 5 is generally favored in a “read-heavy” data environment as write operations will execute at a slower rate. Optional hardware is required to support RAID 5.
Note that all drives must be the same type, speed and capacity.
RAID 6 RAID 6 enhances RAID 5 style disk striping parity distribution by creating enough parity data to handle two disk failures. You can lose a disk and have an unrecoverable error (URE) during reconstruction and still reconstruct your system data. Calculations for the RAID 6 parity stripes are more complicated than those for RAID 5; virtually doubling the workload for the processor on the RAID controller and exacting a performance penalty on write operations. Up to 40% of data space on each disk must be devoted to RAID 6 parity information. Optional hardware is required to support RAID 6 functionality.
Note that all drives must be the same type, speed and capacity.
RAID 10 Mirrored disk striping, the data is striped across one set of drives and then mirrored on another set of drives. A minimum of four drives of the same type are required. The total number of drives must be an even number (4 or 8). A total of four drives is a 2+2 and a total
Page 51
PCIe Expansion Cards
007-6388-001 39
of 8 drives is a 4+4 configuration. The operating system will be striped across the drives in the primary set and then mirrored on the secondary set of drives.
Note that all drives must be the same type, speed and capacity.
PCIe Expansion Cards
There are two internal double-width PCIe 3.0 x16 expansion slots, one PCIe 3.0 x8 low-profile internal slot and one external PCIe slot available with the C1104-GP2/C1110-GP2 servers. The external option slot functions as listed:
External PCI-Express 3.0 x8 low-profile card (x16 slot)
Note: Only specific cards will fit and function in the internal PCIe slots, contact your SGI sales or service representative for information on approved cards.
Power Supply Functional Rating
The C1104-GP2/C1110-GP2 server default configuration is two rear-installed 750-Watt power supplies. The second power supply acts as a redundant power unit for the server. The supplies are “auto-ranging” and can operate from either 100-140V or 180-240V levels at 50 or 60Hz.
Each power supply module has its own cooling fan.
The supplies used have a Platinum Certification rating.
Page 52
Page 53
007-6388-001 41
Chapter 6
6. Basic Troubleshooting and Chassis Service
Use the procedures in the first half of this chapter to troubleshoot your system. If you follow all of the procedures and still need assistance, check with your authorized support organization.
The subsections in the second half of this chapter starting with “Chassis Service Information” on
page 43 are intended to guide you through basic component remove and replace procedures.
Basic Troubleshooting Procedures
Use the information in the following subsections to remedy basic problems you might encounter when working with the SGI Rackable C1104-GP2/C1110-GP2 server.
If the System Does Not Power Up
If the system will not power up when the front power button is pushed, use the following checklist to identify common sources for the problem:
Make sure that both ends of each system power cable are firmly connected to the power
supplies and the corresponding power source(s) or power distribution unit (PDU).
Check to see if the power fail LED is lit on the front of the unit. This LED should be off if
the system is operating normally.
Check that the LED on each power supply is properly lit. The power supply has one status
LED located on the left side of the front of the power supply. The LED has three states:
Dark or off - indicates no AC power present
Solid Amber - AC power is present, the server is not turned on (no DC power)
Blinking Amber - supply temperature exceeds 63
o
C (auto-shutdown occurs at 73o C)
Solid Green - AC power is present and the server is turned on (DC power present)
Page 54
42 007-6388-001
6: Basic Troubleshooting and Chassis Service
Open the system cover, remove the air shroud and check to make sure that no obvious short circuits exist between the serverboard and chassis.
System Powers Up But Will Not Boot
If the system powers up but will not boot the Operating System, check the following:
Check the system order document(s) - the C1104-GP2/C1110-GP2 server may have been ordered with no operating system. If so, check with your system administrator for OS loading information.
Check the system disk (drive 0) for drive activity and confirm that it is firmly seated in the disk bay. A red light on the front of the disk indicates a functional error. Check with your service provider or local system administrator.
No Video After System Power Up
If the system powers up and appears to be booting normally but no video is present, try the following basic solutions:
Confirm your monitor is plugged in and switched on.
Check all video cables and ensure they are properly connected.
Listen for a BIOS “beep code” error message - one long beep plus 8 short beeps indicates a video error. This beep code message could indicate a video memory error or other video malfunction; contact your service provider.
If using an optional PCIe video card check the back of the card for LED activity or a fault indicator. Try opening the system, reseating the PCIe card and rebooting; see the section
“Install/Replace a PCIe Expansion Card” on page 57.
If you cannot get a video signal after trying basic solutions contact your support provider.
Memory Errors
If your system experiences memory related errors, try these basic troubleshooting steps to resolve or better identify the problem:
Confirm that the power supply LED is not indicating an error.
Page 55
Chassis Service Information
007-6388-001 43
Listen for memory error beep codes - five short beeps followed by one long beep is a BIOS
signal that no system memory has been detected - See Appendix A, “BIOS Error Codes”.
Shut the system down, remove the covers over the serverboard and make sure that all the
DIMM modules are properly and fully installed.
You should be using registered ECC DDR4 memory. Also, it is recommended that you use
the same memory type and speed for all DIMMs in the system.
Contact your administrator or support provider if the memory errors continue.
Chassis Service Information
The following sections cover the steps required to install components and perform maintenance on the C1104-GP2/C1110-GP2 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows. Drive placement and physical size will differ between the C1104-GP2 chassis (four 3.5-inch drive slots) and C1110-GP2 (ten 2.5-inch drive slots).
Important: Always disconnect the AC power cord(s) before adding, changing or installing any internal hardware components.
Tools Required: The only tool you will need to install components and perform maintenance is a Phillips screwdriver.
Static-Sensitive Devices
Electrostatic discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally sufficient to protect your equipment from ESD damage.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing any board from its anti-static bag.
Page 56
44 007-6388-001
6: Basic Troubleshooting and Chassis Service
Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard, add-on cards and peripherals back into their anti-static bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.
Unpacking
Replacement components are usually shipped in anti-static packaging to avoid static damage. When unpacking an upgrade or replacement component, make sure the person handling it is static protected.
Control Panel
The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection. Connect the cable from JF1 on the serverboard to the Control Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both connectors. Pull all excess cabling out of the airflow path. The LEDs inform you of system status. See Chapter 3 for details on the LEDs and the control panel buttons.
Drive Bay Installation/Removal
This section describes hard drive installation and removal.
Accessing the Drive Bays
Drives: You do not need to access the inside of the chassis or remove power to replace or swap a RAIDed hard disk drive. Data may be lost or corrupted if you “hot swap” a JBOD disk drive. Shut down system power before removing or replacing a JBOD disk. Removing either a RAID or JBOD drive without replacing it may cause system errors. Proceed to the next section for further hard drive instructions.
Page 57
Drive Bay Installation/Removal
007-6388-001 45
Note: You must use approved hard-disk or SSD drives in the system.
Removing Hard Drives or Carriers from the Chassis
1. Press the release button on the drive carrier. This extends the drive carrier handle.
2. Use the handle to pull the drive carrier out of the chassis.
Important: Empty carriers without drives must stay in the chassis during operation for proper airflow/cooling purposes except during remove/replace operations. Do not operate the server with carriers removed.
The Hard Drive Backplane
The hard drives plug into a backplane that provides power, drive ID and bus termination. A RAID controller and/or optional RAID software can be used with the backplane to provide data security. The operating system you use must have RAID support to enable the hot-swap capability of the hard drives. The backplane is preconfigured, so no jumper/switch configuration is required.
Caution: Be careful when working around the drive backplane. Do not touch the backplane with your fingers or any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airflow.
Disk Drive Installation
The drives are mounted in drive carriers (Figure 6-1 on page 46) to simplify their installation and removal from the chassis, see Figure 6-2 on page 46 for a disk removal example. These carriers also help promote proper airflow for the drives. For this reason, even empty carriers without hard drives installed must remain in the chassis during operation. See Figure 6-3 on page 48 for an example drive carrier and the “dummy” drive blank used when a working disk is not installed in a drive slot.
!
Page 58
46 007-6388-001
6: Basic Troubleshooting and Chassis Service
Figure 6-1 Drive and Carrier Assembly Example
Figure 6-2 Remove Drive and Carrier from Front of Server
Page 59
Drive Bay Installation/Removal
007-6388-001 47
Hard Drive Carrier Assembly Usage
1. Remove the four screws securing the dummy/bad drive to the hard drive carrier.
2. Insert a new/replacement hard drive into the carrier with the PCB side facing down and the
connector end toward the rear of the carrier.
3. Align the hard drive in the disk drive carrier so that the mounting holes of the carrier are
aligned with the mounting holes of the drive. Note that there are holes in the carrier which are marked “SATA” to aid in correct installation.
4. Secure the drive to the carrier with four screws. Use the M3 flat-head screws included in the
HDD bag of your accessory box. Note: the screws used to secure a dummy drive to the carrier should not be used to secure the hard drive.
5. Insert the hard drive carrier assembly into its bay vertically, keeping the carrier oriented so
that the release button is on the bottom. When the carrier reaches the rear of the drive bay, the handle will retract.
6. Using your thumb, push against the upper part of the hard drive handle until the assembly
clicks into the locked (fully seated) position, see Figure 6-4 on page 49 for an example.
Note: Your operating system must have RAID support to enable the hot-plug capability of the drives.
Caution: Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain proper airflow and system cooling.
!
Page 60
48 007-6388-001
6: Basic Troubleshooting and Chassis Service
Figure 6-3 Drive Carrier Attachment to Dummy Drive Blank Example
Page 61
Drive Bay Installation/Removal
007-6388-001 49
Figure 6-4 Hard Disk Drive Installation Example
Page 62
50 007-6388-001
6: Basic Troubleshooting and Chassis Service
Power Supply
The system offers a redundant power supply assembly consisting of two 750-Watt power modules. Each power supply module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage at 50 or 60Hz.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system, see
Figure 6-5 on page 51 for an example.
Removing/Replacing a Power Supply
You do not need to shut down the system to replace a failed power supply unit. The backup power supply module will keep the system up and running while you replace the failed unit. Replace with the same model.
Removing the Power Supply
1. First unplug the AC power cord from the failed power supply module.
2. Depress the locking tab on the power supply module.
3. Pull it straight out using the rounded handle.
Installing a New Power Supply
1. Replace the failed hot-swap unit with another identical power supply unit.
2. Push the new power supply unit into the power bay until you hear a click.
3. Secure the locking tab on the unit.
4. Finish by plugging the AC power cord back into the unit.
Page 63
Power Supply
007-6388-001 51
Figure 6-5 Power Supply Remove/Replace Example
Power Supplies
Page 64
52 007-6388-001
6: Basic Troubleshooting and Chassis Service
Accessing the Inside of the Chassis
1. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a “click”).
2. Next, depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.
Note: Normally you would power down the system before installing or removing internal components - but it may be necessary to leave system power on to determine which fan has failed.
System Fans
Ten 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and works to dampen vibration levels. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fans will ramp up to full speed and the overheat/fan fail LED on the control panel will flash. Replace any failed fan as soon as possible with the same type and model (the system can continue to run with a failed fan).
Your system administrator may be able to identify which fan has failed using the system BIOS.
If an administrator or service representative is not using the BIOS to determine which fan has failed, you can remove the top chassis cover while the system is still running to determine which of the fans has failed. After determining which is the failed fan, shut down and remove power from the system by unplugging the server’s cords. Never run the server for an extended period of time with the top cover open.
Page 65
System Fans
007-6388-001 53
Replacing System Fans
This section describes how to remove or install a system fan.
Remove/Replace a Fan
1. If you have not already done so, remove the chassis cover to access the fans, see the example
in Figure 6-6 on page 54.
2. Turn off the power to the system and unplug the AC power cord.
3. Remove the failed fan's wiring connectors from the serverboard.
4. Remove and retain the four pins securing the fan assembly to the fan tray.
5. Lift the assembly housing the failed fan from the fan tray and out of the chassis, see the
example in Figure 6-7 on page 55.
6. Place the new fan into the vacant space in the fan tray, while making sure the arrows on the
top of the fan (indicating air direction) point in the same direction as the arrows on the other fans in the same fan tray. See Figure 6-8 on page 56 for a fan assembly example.
7. Reconnect the fan wires to the exact same chassis fan headers as the previous fan.
8. Reconnect the AC power cord, power up the system and check that the fan is working
properly before replacing the chassis cover.
Page 66
54 007-6388-001
6: Basic Troubleshooting and Chassis Service
Figure 6-6 Cooling Fans Access Example
Page 67
System Fans
007-6388-001 55
Figure 6-7 Remove/Replace Fan Assembly Example
Page 68
56 007-6388-001
6: Basic Troubleshooting and Chassis Service
Figure 6-8 Individual Fan Remove/Replace Example
Page 69
Install/Replace a PCIe Expansion Card
007-6388-001 57
Install/Replace a PCIe Expansion Card
Confirm that you have the correct PCIe card for your chassis and the card includes a standard bracket. The following type cards are supported in the server chassis:
One low-profile PCIe 3.0 x8 card (above the VGA connector)
Note: At time of publication, the rear x8 low-profile PCIe slot (upper-right in Figure 6-9) is used only for specific internal PCIe option cards. Check with your SGI sales or service representative for the latest information on optional cards available for this slot.
Figure 6-9 Rear PCIe Low-profile Slot
Install/Replace a Low-profile PCIe Card
Use the following steps and illustration to install or replace a PCIe card at the rear of the system:
1. Remove the chassis cover and disconnect both the power cables from the server.
2. Confirm that you have the correct size and type of PCIe expansion card (low-profile).
3. Remove the screw securing the low-profile PCIe slot cover at the rear of the chassis and slide
it sideways to remove from the chassis.
4. Select the appropriate riser connector for your low-profile card. Note that the low-profile
riser card uses a x16 connector.
5. Align the PCIe card with the rear slot opening and the riser connector, then simultaneously
slide the rear bracket into place as you insert the PCIe connector into the riser.
6. Secure the rear bracket in the slot with the screw removed in step 3 and connect cables to the
add-on card as necessary. See Figure 6-10 on page 58 for an example.
VGA Port
Ethernet LAN Ports
IPMI LAN Port
USB Ports
COM Port
UID
Power Supplies (2)
Page 70
58 007-6388-001
6: Basic Troubleshooting and Chassis Service
7. Replace the system cover and plug in the power cords prior to rebooting the server.
Figure 6-10 Low-profile PCIe Card Remove/Replace Example
Page 71
007-6388-001 59
Appendix A
A. BIOS Error Codes
During Power-On Self-Test (POST) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list (see Table A -1) correspond to the number of beeps for the corresponding error.
Table A - 1 BIOS Error Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset (Ready to power up)
5 short beeps + 1 long beep Memory error No memory detected in the system
5 short beeps Console input or output
device missing
Console-In: USB or PS/2 keyboard, PCI or Serial Console Redirection, IPMI KVM or SOL Console-Out: Video Controller, PCI or Serial console Redirection, IPMI SOL
1 continuous long beep System overheat condition System thermal limits exceeded
1 long beep +8 short beeps Video display error or video
memory read/write error
Video error - adapter missing or with faulty memory
Page 72
Page 73
007-6388-001 61
Appendix B
B. System Operating and Regulatory Overview
This appendix provides basic environmental operating requirements and regulatory information for the server.
Environmental Specifications
Table B- 1 lists allowable ranges for temperature, humidity, and altitude for the server.
Table B - 1 Temperature, Humidity, and Altitude Specifications
Attribute Specification Rate of Change Constraints
While Product Operating
Temperature – Up to 1500m (5000ft)
+5º to +35º C (+41º to +95º F)
– 1525m (5000ft) to 3050m (10,000ft)
Reduce max temperature (35ºC) by 1ºC per 305m (1000ft) of altitude above 1525m (5000ft).
Maximum: 10
ºC/hour (18ºF/hour)
Humidity 20% to 80% Non-condensing Maximum: 10% relative
humidity/hour
Altitude 3050m (10,000ft)
While Product Power Off
Temperature +5
ºC (41ºF) to +45ºC (113ºF) Maximum: 20ºC/hour (36ºF/hour)
Humidity 8% to 80% Non-condensing
Altitude 3050m (10,000ft)
Page 74
62 007-6388-001
B: System Operating and Regulatory Overview
System Input Requirements
AC Input Voltage: 180-240 VAC
Rated Input Current:100-120V/9.5A, 200-240V/4.5A
Rated Input Frequency: 50-60 Hz
Power Supply
Rated Output Power: 750W (Redundant) (80+) Platinum rated
Rated Output Voltages: +12V and +12Vsb (2A)
While Product Packaged for Shipping
Temperature -40
ºC (-40ºF) to +60ºC (140ºF) Maximum: 20ºC/hour (36ºF/hour)
Humidity 8% to 80% Non-condensing
Altitude 12,200m (40,000ft)
Table B - 1 Temperature, Humidity, and Altitude Specifications (continued)
Attribute Specification Rate of Change Constraints
Page 75
Regulatory Compliance
007-6388-001 63
Regulatory Compliance
This product is for installation in a Restricted Access Location only per clause 1.7.14 of IEC document 60950
The SGI compliance number for this product is CMN1110-819U-7
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See: www.dtsc.ca.gov/hazardouswaste/perchlorate”
Page 76
Loading...