Silent Night ZERA-500 User Manual

1
Breathe with Confidence®
“Capturing millions of unwanted biologicals
and allergy triggers for pennies per day”
800PUREAIR
Silent Night® Users Manual
ZEPA-500 AIR PURIFIER
Dust
Mold Spores
Dander
Smoke
Allergens
Germs
Viruses
VOC’s
2
Table of Contents
Introduction
Page 3
General Safety
Page 4
Setup & Operation
Page 4, 5
Maintenance
Page 5
Specifications
Page 5,6
Biological Challenges
Page 6
4 Functional Stages
Page 6,7
ZEPA Filtration
Page 7
Our Inventor
Page 8
Applications
Page 8
Warranty
Page 9,10
Testimonials
Page 10
Changing Filters
Page 11
Health Disclaimer
Page 12
CERTIFICATIONS
MET has certified, listed, and labeled products for electrical product safety for 40+ years. In that time, MET has certified thousands of products for compliance to electrical safety standards. This translates into millions and millions of units sold in the U.S. and Canada labeled with the MET mark.
This product has been certified by NRTL (Nationally Recognized Testing Laboratories), a safety testing facility recognized by the Occupational Safety Health Administration
(OSHA) and in compliance with 29 CFR. 1910.7.
This product earned the ENERGY STAR by meeting efficiency guidelines set by the U.S. Environmental Protection Agency. The efficiency of this ENERGY STAR qualified model is measured based on a ratio between the unit's CADR for dust and the electricity it
consumes, or CADR/Watt.
IBR is an A2LA accredited, independent, laboratory providing testing services for the detection and analysis of particulate contamination and verification of filtration performance. Laboratories are located in USA and England.
NRTL
CE marking indicates compliance with EU legislation, and enables a product's free movement within the European market (European Economic Area and European Free Trade Association).
3
Congratulations on choosing the Silent Night ZEPA-500 fanless air purifier. The power of this machine is that it will capture millions of unwanted biologicals and allergy triggers for just pennies per day.
Its technologies have been validated by leading university scientists, and reported in respected scientific journals. After several air purifier inventions, engineer Stan Weinberg says that his patented fanless Silent Ion-Drive technology is the achievement of his lifetime.
The Silent Night ZEPA-500 is unmatched for effectiveness, economy, low operating cost and noise level. Silent Night’s virtually silent technology will prove time and time again to outperform most HEPA products, effectively capturing all particle sizes including PM 2.5 with minimal energy usage.
(NRTL) Nationally Recognized Testing Laboratories, certified by (AHAM) American Home Appliance Manufacturers, established Silent Night’s official (CADR) Clean Air Delivery Rate to be 311 (cigarette smoke rated). That means it purifies a 500 square foot room 4.7 times per hour (or 112 times every 24 hours) with only 39 watts of power! Testing has been done with worst case (hardest to capture) MPPS (most penetrating particle size) of .3 microns, which was used in the Centers for Disease Control and Prevention (CDC) Intertek and IBR independent laboratories.
Silent Night’s testing protocol includes air flow, room size, distance from the appliance, time of operation, and the reduction of particles down to .1 microns in diameter. Many viruses and all bacteria fall in the ranges that are measured. We also capture mold spores, pollen, pet dander, smoke particulate, skin flakes and dust mites.
The unit is most effective in a closed room such as a bedroom, office, etc. More than one unit may be necessary in larger areas where new pollution is constantly added by life’s activities.
The ZEPA-500 was designed, engineered, assembled and certified in the USA. Unlike most air purifiers, it is designed to run 24/7 at maximum effectiveness using only 39 Watts of electricity. Now you can Breathe with Confidence® knowing your Silent Night® is removing millions of airborne particles, dust, mold spores, dander, smoke, pollen, allergens, germs, viruses and most volatile organic compounds (VOC’s) every minute of every day!
Introduction to Silent Night®
4
1. Do not open or disassemble the unit. No user-serviceable parts inside.
2. Not for outdoor use. Keep away from moisture, spills, open flame, extreme heat.
3. Use only the adapter provided. A substitute adapter may harm the unit and will void your warranty.
4. Operate 9 inches from any wall and not on or near metal surfaces.
5. When using the range extender, operate 10 feet from any wall to avoid gray-wall and do not operate on or near metal surfaces.
6. To avoid static shock, do not touch the unit or the range extender directly. This harmless static effect is similar to dragging your feet across the carpet.
7. Operating closer than 9 inches from your body can cause a harmless static discharge when you touch a grounded surface.
8. Do not operate within 2 feet from any computer equipment.
9. Extension cords are safe to use with your unit but be cautious; it can become a tripping hazard.
ELECTRICAL SAFETY: Electrical safety features are incorporated to prevent shock hazards. As to shock potential, the Department of Energy classifies static charge potential below 250 mJ (millijoules), the level of carpet static, as safe for humans. The ZEPA-500 model is well below this level.
OZONE SENSITIVITY: The Silent Night ZEPA-500 meets ozone safety standards in California, Canada, and around the world.
1. Review the General Safety instructions before operating your unit.
2. Insert supplied DC power jack into receptacle on the unit’s right side, with the power switch OFF (O).
3. Insert universal adapter prongs into AC outlet.
4. Electrostatic filters located at the base of the unit are installed on tracks for quick and smooth replacement. (Refer to page 11)
5. On rocker switch press “|” for ON and “O” for OFF. When ON (|), you’ll observe a low intensity blue light inside the front grille.
General Safety
Installation & Operation
Loading...
+ 8 hidden pages