Silent Call Communications MR1214-MC Installation And Operation Manual

Document #
1081243126052
MINI RECEIVER
Installation and Operation Manual
Model # MR1214-MC
418 MHZ RECEIVER
The Mini Receiver is a 418 MHz wireless alerting device equipped with 24 hour battery backup. Main Power is supplied using a Silent Call 18 watt AC/DC Wall mount Adapter P/N 890007-2. The Mini Medallion Series Receiver can store up to 20 from a possi­ble one million, Silent Call 418 MHz Medallion Series transmitter address codes.
Installation:
Installing the Mini Receiver consists of locating it where it can be noticed most effectively by the user. Plug the AC/DC wall mount adapter into any standard household 110VAC 60Hz outlet. Insert the adapters DC barrel plug into the Mini Receiver Barrel Jack Labeled “Power”. Slide the power switch to the ON position and confi rm the Power ON GREEN LED is illuminated under the top strobe lens. The receiver is now ready to be programmed.
Programming:
NOTE: All Medallion Transmitters will be required to be pro-
grammed to your new receiver.The receiver leaves the factory with the memory cleared.
Apply power to the receiver as described in the Installation sec­tion. With the receiver powered, press and hold the program button located at the back of the receiver case. All display icons will illu­minate. Continue to hold the program button until the icons goes out (about 3 seconds) and then the GREEN PHONE icon blinks 3 times. Release the program button. The receiver display icons will come back on to indicate that the receiver is now in program mode. The receiver will remain in program mode for approxi­mately 30 seconds, and the display icons will start to go out to indicate the program time remaining. While in program mode, the transmitter you wish to program must be activated (Trans-
mitting) for the receiver to memorize the code of the transmitter. The transmitter can be activated by pressing the test button on the corresponding transmitter. When the receiver receives the transmitted signal, it will memorize the code. The receiver should activate and fl ash the top strobe light, and the appropriate display icon will illuminate. Programmed transmitter codes are retained in memory even when the power is removed.
Erase memory:
To erase all programmed codes:
All Erase – Press and hold the program button, the Display icons will come on for about 3 seconds, go off and then the GREEN PHONE icon will blink 3 times. Continue to hold the program button an additional 3 seconds until the icons scroll in a counter­clockwise direction several times indicating all previous learned transmitters that were stored in memory have been erased. Release the program button and all previously learned transmitter codes will have been successfully erased.
Battery Backup Mode:
In the event of a main power loss or failure of the wall adapter, the Mini Receiver will automatically enter into the battery backup mode. The Mini Receiver has been tested to provide at least 24 Hours of Battery backup operation with 15 minutes of Alerts. Located under the top strobe lens cover is an AMBER LED. The AMBER LED will blink once every 10 seconds, indicating Input DC power loss to the receiver and it is operating on the back-up battery. The AMBER LED will blink at a one second rate once the back-up battery has reached minimum operating voltage. Operat­ing the receiver during a low battery indication is not recommend­ed. IMPORTANT: The Mini Receiver will need to charge two hours for every hour in Battery backup mode or a full 40 Hours after low battery indication to ensure complete battery recharge.