Standard operation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU-PIR-MKX
Universal Monitor 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
1 = System Code 1
2 = System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = System Code Override
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = Poling signals
10 = Sound Level Display
11 = Smoke / Fire
12 = Burglar/ Car
13 = Baby Alarm
14 = Person to Person
15 = Door Bell
16 = Telephone
MOVE KEY DOWN
TO SWITCH ON
Configuration switches
Audio spindle
Test button
PP3 battery clip
Power supply socket
External microphone
Press and briefly hold the test button
The light will shine green and the monitor
will send a signal.
2.
Check the desired signal is
received by the Pager or
SignWave and fix in place
using the screw kit or
Velcro provided
An Alkaline PP3 battery should last one year.
3.
Low battery signals will be sent to
your Pager or SignWave when
the battery needs replacing.
The test button will also shine
orange to show the status of
the battery.
Only use Alkaline or Lithium PP3
batteries as cheaper alternatives
will not last as long.
Move Key 15 to the right. Connect a 9V
Alkaline PP3 to the battery clip.
1.
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Alkaline
PP3
Sound activation
Ideal for monitoring door entry phones or wireless door chimes. Audio trigger delays can be used to reduce false alarms
from transient noise (door slams etc).
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
Move keys 5 & 7
to the right.
1.
The test button will light amber
when a sound is detected and
change to green once it exceeds
the delay.
Switches 7 & 8 alter the
delay period.
short
medium
long
3.
Turn the spindle on the side of the
monitor half a turn clockwise until the
slot is horizontal.
Place the microphone near the sound
source you with to monitor.
More sensitive
Less sensitive
2.
4.
Place the microphone close to the
sound source
(shown here behind a door
entry phone).
Activate the phone/alarm and check
the monitor triggers.
See step 3 if a trigger delay is
needed. This can help eliminate
false triggers in noisy environments.
5.
PUSH
We do not recommend using
this device for monitoring
normal telephone or smoke
alarms as dedicated
telephone and combined
smoke alarm units are
available in the
SA3000 range.
Care
Call
TM
Silent
Alert
Quick start guide UM3A-2212-EU-MIC
Universal Monitor with External Microphone
TM
Silent
Alert
Any questions? Call us on
+353 (0)1 247 9007

The monitor can be coded to light any one of the event symbols on the Pager or SignWave.
The diagram below shows the relevant key settings.
Event Setting
Changing the system channel code
NOTE: In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other SA3000 systems using up to a maximum of 16 channels.
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
2
3
4
5
6 7 8
9 10
11 12
13
14
15 16
1
Voltage triggering
A voltage applied across
terminals 1 & 2 will also
trigger the unit. Both AC and
DC voltages from 5 - 30 Volts
will activate the unit.
6.
WARNING
DO NOT apply mains power or any voltage in
excess of 30 Volts as damage will result.
Only suitably qualified persons should attempt to
link this unit into systems or equipment other
than a low voltage door chime
4.
The input terminals can be used to
connect to doorbells, door entry
phones, fire, burglar & car alarms.
Short Circuit triggering
A short applied across the
top and bottom terminal will
trigger the unit.
5.
7.
8.
Common (negative)
to terminal one
Wiring example
When wiring across a coil
or similar, use the
voltage input.
When wiring parallel across
a bell push use the short
circuit input.
Make sure the common
(negative) wire on the bell push
is connected to the bottom
terminal to avoid
false triggering.
TM
Silent
Alert
Advanced settings UM3A-2212-EU-MIC
Universal Monitor with External Microphone
Any questions? Call us on
+353 (0)1 247 9007