silavent SVC100 Installation Instructions Manual

Installation Instructions
SVC100
Shuttered
Axial Wall / Window Fans
CLEANING
Disconnect power supply before cleaning. It is important to clean fans annually as regular cleaning helps maintain performance and ensure safe, reliable operation.
The front cover shutter can be removed from the fan and gently dusted with a soft brush or washed in warm water with dishwashing liquid. Dry carefully before refitting.
IMPORTANT : Make sure that the shutter thermoactuator on the fan chassis is fully withdrawn (i.e. cold)
before fitting the front cover shutter.
The interior of the fan can be dusted with a soft brush. Do not use water.
On humidity control models, please ensure that no water enters the sensor grille.
For window fitting, the SDF901WFK window kit is required.
OPERATIONS
Timer Adjustment - Timer Models only
Isolate the power supply. Replace front cover BEFORE switching on the power supply. The timer is factory set at midpoint. Time is set by placing the black bridge over 2 of the pins on the right hand side of the timer board. If bridge is not fitted, timer will default to 20 minute setting. Replacement bridges are available from Silavent.
HUMIDITY ADJUSTMENT - HUMIDITY MODELS ONLY
Isolate the power supply. Replace the front cover and the humidity control adjustment position is clearly marked. Turn clockwise for less sensitivity and anti-clockwise for more sensitivity. Turn fully clockwise to turn the humidity sensor off. Replace front cover BEFORE switching on the fan.
SVC 100 RANGE
230v AC - 50Hz 15W Single Speed IPX4 Rating – This product is double insulated.
Manufactured in the UK by
ISSUE 1
17/01 LAB538R
SVC100B Standard SVC100PB With Pull Cord
SVC100TB
With
Timer
SVC100HTB
With Humidistat
and Timer
SVC100HTBPC
With Humidistat, Timer
and Pull Cord
30 Mins 15 Mins 5 Mins
Polypipe
Polypipe
Sandall Stones Road, Kirk Sandall Industrial Estate, Kirk Sandall, Doncaster DN3 1QR Tel: +44 (0) 8443 715523 Fax: +44 (0) 8443 715524 www.polypipe.com/ventilation
www.polypipe.com
SILAVENT SVC 100
Window / Wall Fan
These high quality extractor fans are designed to give effective ventilation and in order to achieve this, please read these instructions carefully BEFORE installing the fan unit. Failure to comply with these instructions could reduce the life of the product and may invalidate the warranty.
This product is suitable for use with up to 2 metres of ducting.
WIRING INSTRUCTIONS
It is recommended that the fans be connected into the lighting circuit, with double pole (3mm) isolation provided before the room light switch and suitably fused, in accordance with IEE Regulations.
Window fans should be connected to power supply using a flexible cord with conductors of between 0.75mm
2
and 1.5mm2only. Wall and ceiling mounted fans for fixed wiring
should be connected to the power supply via a cable with solid conductors of 1mm
2
to
1.5mm
2
only.
CAUTION : Fans incorporating electronic control systems may be damaged if used in
conjunction with fluorescent lamps. If in doubt, we recommend you contact Silavent customer services on
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
CONDENSATION TRAP
FAN
FAN
WALL GRILLE
FALL TO OUITSIDE
MODELS
SVC100TB
SVC100HTB
SVC100HTBPC
MODELS
SVC100B
MODELS
SVC100PB
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
DO NOT INSTALL IN SHOWER CUBICLES
MAXIMUM ROOM TEMPERATURE 50ºC
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
FITTING WALL FAN
1. Select a suitable position for the Silavent fan in relation to outside walls, ceilings and roofs, keeping the ducting as short as possible – see Ducting.
2. Cut a hole in the wall or ceiling to take rear spigot of fan plus ducting if fitted.
3. Remove the front cover from the fan by undoing the retaining screw at the bottom edge of front cover. Position the fan chassis and mark the retaining screw positions.
4. Remove the appropriate cable entry knock out position from the fan chassis and thread power cable through before fixing the fan to the wall.
Note: Fans fitted with pull cord switches are not
suitable for ceiling mounting.
DUCTING
1. Bring the ducting to the chosen locations and trim its ends flush to the surfaces.
2. Note that there are 3 basic types of installation and that condensation drainage should be provide d as shown. Ceiling location makes drainage provision essential.
3. A small condensation trap should be made at the lowest point of the ducting as shown it is advisable to lag duct.
Note: All the ancillary items can be obtained through
Silavent Stockists.
To access terminals
on these models,
lift off control cover
S/L N L N L N L
S/L N L N L N L
Operating
Switch
Isolator
Switch
Isolator
Switch
L = LIVE N = NEUTRAL S/L = SWITCH LIVE