SIIG Large Full-Motion TV Wall Mount Installation Manual

Large Full-Motion TV Wall Mount
Installation Guide
Articulating Full-Motion Universal Flat-Panel TV Wall-Mount TV size: 42" to 80" Tilt angle: 10 degrees up / 15 degrees down Max load capacity: 154 lbs Wall distance (at the front plate): 3.75" to 17.35"
Important: If you have difficulty following or understanding these installation instructions, please consult a qualified installation specialist.
04-0971A
1
Caution
Prior to installation of this product, the installation guide should be read and completely understood. The installation guide must be read to prevent personal injury and property damage. Keep the installation guide in an easily accessible location for future reference.
This mount contains small parts which can act as a choking hazard if swallowed.
CAUTION: The maximum load capacity is 154 lbs. Use with products exceeding the maximum load capacity may cause serious injury. See apparatus instructions.
The wall structure must be capable of supporting at least five (5) times the maximum load capacity as indicated. If not, the wall must be reinforced.
Recommended mounting surfaces: wood stud and solid-flat concrete. If the mount is to be installed on any surface other than wood studs or solid concrete, use suitable hardware (not included but commercially available).
Do not install on a structure that is prone to vibration, movement or chance of impact. Failure to do so could result in damage to the display and/or damage to the mounting surface.
Do not install near heater, fireplace, air conditioning, in direct sunlight or any other heat producing source. Failure to do so may result in damage to the display and could increase the risk of fire.
Make sure no water or natural gas lines are present where the mount is to be installed. Cutting or drilling into water or natural gas lines could cause personal injury or property damage.
Proper installation procedure by yourself or a qualified service technician, as outlined in the installation guide, must be adhered to. Failure to do so could result in serious personal injury.
When mounting to a wall that contains wood studs, confirm the dead center of the wood stud prior to installation, it is recommended that the wood studs be a minimum of 16" apart (if applicable).
This product is intended for indoor installation/use only. Premature product failure or serious personal injury could occur if this product is used outdoors.
It is recommended that two people perform the installation. Injury and/or damage can result from dropping or mishandling the display.
Tools Required
Electronic stud finder for drywall installation
Phillips head screwdriver
Socket or wrench set (metric)
Electric drill, 5/32" drill bit for wood stud installation, 3/8" masonry drill bit for concrete/brick wall installation
Important: The Large Full-Motion TV Wall Mount is shipped with the proper installation hardware and parts. Make sure that none of the items are missing or damaged before starting the installation. If there are any missing and/or damaged parts, please stop the installation and contact your place of purchase.
2
Hardware Kit
a
(x1) Wall plate
ehf
(x4) M4x12 bolt
(x4) M4x30 bolt
b
(x1) Left monitor bracket
(x1) Right monitor bracket
c
g
(x4) M5x12 bolt (x4) M8x16 bolt
j
(x4) M6x12 bolt
ki
l
(x4) M5x30 bolt (x4) M6x35 bolt (x4) M8x40 bolt
(x4) M4 lock washer
qr
(x4) M4/M5 spacer
vw
n
(x4) M5 lock washer
(x4) M6/M8 spacer
o
(x4) M6 lock washer
st
(x8) M4/M5 washer
x
pm
(x4) M8 lock washer
(x4) M6/M8 washer
y
(x6) Lag bolt
(x6) Lag bolt washer
(x6) Concrete anchor
(x1) Bubble level
3
Step 1: Wall Plate Installation
A) Wood Stud Installation (16" on center)
1. Use a high quality electronic stud finder (commercially available) to locate dead center of two wood studs 16" apart and mark the location with a pencil. See Figure 1.
2. Mount the bubble level (y) onto the wall plate at the position shown. With the help of an assistant, place the wall plate onto the wall in the desired mounting location and check the bubble level to ensure it is level. See Figure 2.
3. Mark the right (upper and lower) and the left (upper and lower) positions of the small horizontal slots that are in alignment with the wood studs. See Figure 2.
4. You should mark four positions total. Take down the wall plate.
5. Next, pre-drill a 5/32" hole to a depth of 3" in the wood stud at each marked location.
6. Place the wall plate against the wall and line up the mounting slots with the drilled holes. Check the bubble level to verify that the wall plate is level.
7. For each location, insert a lag bolt (v) and washer (w) into the wall. See Figure 2.
8. Tighten the bolt with an open ended or socket wrench by turning clockwise until tight.
Figure 1
y
Figure 2
CAUTION: Do not over tighten the bolts - doing so may cause unnecessary damage to the
wall. CAUTION: Do not release the wall plate until it is properly mounted and secured to the wall.