Sigrand SG-17B, SG-17B-261, SG-17B-441, SG-17B-351, SG-17B-111 User Manual

...
«Sigrand» LLC
SHDSL modem
«Sigrand SG-17B»
User’s manual
Novosibirsk
2013
2
© «Sigrand», 2005 – 2013
All the trademarks, signs and copyrights associated with the items referred to in this document belong to the relevant right-holders.
ТУ 6665-017-77565155-2007
3
Table of Contents
How to use this «Manual…» ....................................................................... 5
The use of fonts in the text .......................................................................... 6
1. Description of the modem ..................................................................... 7
1.1. Characteristics of the linear DSL interface ...................................... 8
1.1.1. Communication range and bitrate of Sigrand modem ............... 9
1.2. Characteristics of the Ethernet interface ....................................... 10
1.3. Characteristics of the RS-232C interface ...................................... 10
1.3.1. Functions of contacts in the power socket RS-232C ............... 10
1.4. Power ........................................................................................... 11
1.4.1. Remote power Power-over-DSL (PoDSL) .............................. 12
1.4.2. Local powering of the modem ................................................. 12
1.4.3. Through-line powering ............................................................ 12
1.4.4. Power-over-Ethernet powering of the equipment .................... 13
1.5. Other information .......................................................................... 14
1.6. Scope of delivery .......................................................................... 15
1.7. Operating conditions ..................................................................... 15
1.8. Appearance and functions of indicators and sockets..................... 15
1.8.1. Indicators and sockets indoor case ......................................... 16
1.8.2. Indicators and sockets outdoor case ...................................... 19
2. Setting up the modem for operation .................................................... 20
2.1. Connecting the modem to the cable ............................................. 20
2.1.1. Specific features of connecti ng the modem to a PoDSL line ... 20
2.1.2. Requirements for the communication line ............................... 21
3. Management of the modem ................................................................ 22
3.1. How to link-up and set-up a terminal ............................................. 22
3.2. Control commands ....................................................................... 22
3.3. Management of the DSL interface ................................................ 24
3.3.1. Choosing between the «master»/«sl ave» opt i ons ................... 24
3.3.2. Adjusting the DSL interface rate ............................................. 24
3.3.3. Choosing the linear encryption ............................................... 25
3.3.4. Adjusting the auxiliary DSL parameters. ................................. 27
3.3.5. Review of the current configuration of the SHDSL interface .... 27
3.3.6. Statistics of the SHDSL connection ........................................ 28
3.3.7. Resetting the connection ........................................................ 29
3.4. Adjusting the Ethernet interface .................................................... 29
3.5. PoDSL and PoE modes ................................................................ 29
4
4. Updating the embedded software of the modem ................................. 29
Guaranty and warranties ........................................................................... 33
WARRANTY CARD .................................................................................. 34
Appendix А ............................................................................................... 35
5
How to use this «M anua l…»
To make this manual easier to use, the following icons and f onts are provided for:
Icons
Icon
Meaning
Explanation
Take note of it!
A section of this manual marked
with this icon can make it easier for you to set up and operate the
device
Important
information
A paragraph marked with this
icon contains an important information about specific features of a unit or program which is meant to save your time and effort when setting up the
device
Don’t do it!
This icon is to prevent you from
taking any steps that can cause either a breakdown of the
equipment or a danger to life
6
The use of fonts in the text
Designation
Explanation
Image in the screen
This font is used to show the
contents of the terminal screen when you are setting up the
modem.
Name of a key of the keyboard
This font is used to name the
keys of the computer keyboard (e.g. Enter) which are used when setting up the modem through a
terminal
Select Properties in the File menu
Fragments of the «Manual …»
containing important information are printed in italics (combined with icons); also, italics is used
for program menu buttons.
stat
The bold font is used to
designate commands managing the modem through a terminal
program.
Before you start setting up the modem, please visit our site
www.sigrand.ru and see whether there is a new version of this
«Manual …» or an update of the firmware and drivers.
7
1. Description of the modem
Sigrand modems «SG-17B» are SНDSL-modems with Ethernet interface designed for integrating distributed local networks and connecting remote computers and devices that are supplied with Ethernet interface.
Feature of a num ber of modification modem (SG -17B-261, SG-17B-161) is
the ability to obtain, and for modifications (SG-17B-441, SG-17B-351) the possibility of filing, remote powering through a SHDSL line (Power-over­DSL). Feature to obtain is available when the modem is used in combination with the following equipment produced by « Sigrand »:
DSLAM SG-17S ( with interface modules MS-17H4P2);
Router SG-17R (with interface modules MR-17H1P2 and MR-
17H2P2);
Regenerators SG-17E2P-SLG;
Modems modifications SG-17B-441, SG-17B-351;
Modems SG-17B-111, SG-17B-121, and SG-17B-141 are powered from a local power source with voltage 3.3, 12, or 48 V - in this case, SG-17B modems can be operated in combination with Sigrand non-function of the remote powering:
DSLAM SG-17S ( with interface modules MS-17H4);
Router SG-17R (with interface modules MR-17H1 and MR-
17H2);
Modems SG-17B of various modifications.
Ethernet interface of modems SG-17B-541 and SG-17B-261 allows
connection of devices powered through Power-over-Ethernet technology
(IEEE 802.3af standard, Class2). Also modems modification SG-17B-151 and SG-17B-351 can be powered by technology Power-over-Ethernet (IEEE 802.3af standard, Class1, Class3). A full list of modificat ion series modem S igrand SG-17B is shown in table 2 (page 11).
8
The interface of SHDSL modem complies with ITU-T G.991.2.bis version
(the version of 2005) and uses the TCPAM – Trellis-Coded Pulse Amplitude
Modulation encoding set for data transfer.
The modem is equipped with the following interfaces:
one SHDSL interface (ITU-T G.991.2.bis standard) operating in the bitrate range 192-15296 Kb per second;.
one Ethernet interface 10/100Mb (IEEE 802.3) with the options of automatic rate adjustment and auto-sensing MDI/MDI-X;
one RS-232C interface for managing the modem.
1.1. Characteristics of the linear DSL interface
Connection type
point-to-point
The number of wires in the communication line
2 (one pair)
Type of the cable
ТПП, КСПП, UTP
Linear code
TCPAM
Input and output resistance, Ohm
135
Bitrate range of data transfer, Kb per second
192-15296
Step of bitrate change, Kb per second
64
Type of communication
full-duplex
Mode of data transfer
synchronous, packeted
Packet format
HDLC
Checksum
CRC32
Type of socket
2EDGR-5.08-03P
Breakdown voltage of the galvanic isolation transformer, not less than, V
1500
Arrester response voltage (differential), V
30
Breakdown voltage of the surge arres ter
(phase-locked), V
350
9
1.1.1. Communication range and bitrate of Sigrand modems
Brief information on communication range and bitrate of Sigrand SG-17B
modems is given in Table 1. The results were obtained with the length of lines providing the value of Bit Error Rate (BER) equal or less than 10
-7
. The specified value of comm unication range is proved e xperimentally at the test communication line of Sigrand Laboratory. T he c omplete Table of bi trates is shown at www.sigrand.com. The actual results shown at a real communication line may differ from the specified values because of possible diversiti es in the parameters of the lines.
Table 1
Bitrate
(Kb per second)
Linear code Parameter
Cable
ТПП100-0.5
15296 ТСРАМ128
Length (km)
0,6
R (Ohm)
150
10240 ТСРАМ64
Length (km)
1,8
R (Ohm)
324
7168 TCPAM64
Length (km)
2.8
R (Ohm)
504
5696 TCPAM32
Length (km)
3.4
R (Ohm)
612
3072 TCPAM16
Length (km)
5
R (Ohm)
900
2304 TCPAM16
Length (km)
5.4
R (Ohm)
972
1024 TCPAM16
Length (km)
7.8
R (Ohm)
1404
512 TCPAM16
Length (km)
9.0
R (Ohm)
1800
The actual bitrate range may happen to be limited with 5.7 Mb per sec ond in
case the modems are used in combination wit h some types of interfaces issued before 2009 which have bitr ate limitations.
10
1.2. Characteristics of the Ethernet interface
Type of the interface
10/100 Base-T
The number of ports
1
Bitrate, Mb per second
10/100
Mode of operation
Half- and full-duplex
Compatibility
ANSI/IEE E Std 802.3
Auto-sensing MDI/MDI-X
Available
1.3. Characteristics of the RS-232C interface
Bitrate, b per second
115 200 or 9600
Protocol
8-N-1
Flow control
absent
Socket type
RJ-45
The bitrate of RS-232C interface depends on the version of the
embedded software. By def ault, software supporting bitrate of 115200 b per second is installed.
1.3.1. Functions of contacts in the power socket RS-232C
1
RTS
Figure 1
2
DTR
3
TxD
4
GND
5
DCD
6
RxD
7
DSR
8
CTS
plug connector
socket connector
11
1.4. Power
Modem series Sigrand SG-17B has modification with different t ype of power – ~220B, PoE receipt and delivery, a wide range of DC voltage: 12V, 24V,
48V and modification of the issuing and receiving the remote powering through a DSL line (Table 2).
Table 2
modification
type of modem power output voltage execution
220V AC
9,2…36 V DC
18…72V DC
48V DC (PoE)
120…240V DC
(PoDSL)
PoE
48 (до 10 Вт)
PoDSL (240V DC)
sealed IP66
mounting on
DIN-rail
SG-17B-111
* option
option
SG-17B-121
* option
SG-17B-141
* option
SG-17B-541
48
Class 2
option
SG-17B-161
* option
SG-17B-261
*
Class 2
* option
SG-17B-151
Class 1
option
SG-17B-441
48 * option
SG-17B-351
Class 3
* option
SG-17B-IPE where:
I – interface (1 - one Ethernet an one SHDSL; 2 – one Ethernet PoE output and one SHDSL PoDSL input; 3 – one Ethernet PoE input and one SHDSL PoDSL output; 4 – one Ethernet PoE output and one SHDSL). P – power (1 – 3, 3V; 2 – 12V; 3 – 24V; 4 – 4 8V; 5 – 48V PoE; 6 – 240V PoDSL). E – enclosure (1 – indoor case; 2 – IP66 case; 4 – indoor case with mounting on DIN-rail; 5 – IP66 case with mounting on DIN-rail;)
With a maximum load of PoDSL (17W) for SG-17B-351 mod em po w er
consum ption is about 20 W, which corresponds to the class of consumption
PoE +