The Segment Control Unit is central processing unit (CPU)
in the cabinet system. Equipped with a powerful ARM
Cortex A5 (550MHz) processor and a Linux kernel.
Commonly used interfaces for Energymeter, load current
and leakage measurement, relays for contactor mains
switching are integrated into the Segment Control Unit for
ease of wiring and compactness.
Direct communication between the optional modules
takes place by means of an A-Bus interface, which is
based on the industrially proven RS485 technology.
Page 2
LCN7700
86 mm (3.3 in)
The Segment Control Unit serves as a WAN
communications and data concentrator module.
Two-way communication with the central server takes
place via Ethernet, GPRS (3G/2G) or SMS. The module
has the ability to automatically switch between
dierent available communications carriers in order
to provide stable and reliable communication.
Data are either delivered to the server immediately or
stored locally in the built-in ash or external SD card
memory of the Segment Control Unit until scheduled
delivery. Software and congurations are updated
remotely from the server and stored on the Segment
Control Unit enabling it to autonomously execute
tasks, e.g. turn the streetlight on/o or collect meter
readings based on the congurations set up by the
us er.
Voltage values on all three phases of the main supply
are monitored by the Segment Control Unit. If the
module is installed together with a Battery module,
the Segment Control Unit will be supplied with backup
power via the A-Bus in the event of power failure. This
enables the Segment Control Unit to store data and
send a main power failure alarm to the central server
before it shuts down safely.
In general, the Philips Segment Control Unit can be
used for remote light management in diverse outdoor
Lighting applications.
.
Dimensional drawing
192 mm (7.5 in)
58 mm
(2.2 in)
Philips quality
Lifetime: 70000 Hrs @ 10% failure rate.
For more detailed information see the specic
module manuals & guides.
Applications
The Segment Control Unit is a power grid monitoring
and group lighting control device.
It is designed to be installed inside an IP65 rating
outdoor street cabinet. This control unit is designed
as a local controller for group light controls as in
road and street, expressway, premises/campus area
lighting, public parks or in tunnel lighting applications.
For remote connectivity, 2G/3G network can be used
or Ethernet connectivity in case the cabinet is located
indoors.
The accurate current measurement can help to detect
power thefts when the current value goes beyond
a threshold limit dened. The inbuilt GPS locater
helps to detect the location of the installed controller
remotely to enable ease of commissioning. The DALI
interface gives opportunity to control other DALI
enabled devices like a group of luminaires in a high
mast pole in airport or port applications with dimming
capability. The wide input power supply voltage range
from 120-277V makes the controller to be used in wide
geographical locations. The use of an external surge
protection module is highly recommended to protect
the Segment Control Unit from surges.
2Produc t Guide - LCN7700
Page 3
Functional specications
The Ethernet connection is, in addition to this,
functionally insulated with respect to the secondary
connections. See for detailed information the
technical specication section.
Primary
GSM/GPRSSMA connector for external
GSM antenna. GSM850,
E-GSM900, GSM1800
(DCS1800), GSM1900
(PCS19 00).
Power (L1, L2, L3, , N)
Three mains rated phase (line) inputs: L1, L2 and L3
One mains rated alarm monitor input:
One mains neutral input: N
The Segment Control Unit can be mains powered by
one, two, or three phases plus neutral. When powered
by multiple phases, the Segment Control Unit is able
to detect phase faults on the mains power supply.
If a fault occurs on one or two phases, the Segment
Control Unit will still be powered by the remaining
phase(s). In this case, the Segment Control Unit will
send an alarm to the central server. The alarm monitor
( ) is a mains rated input (related to mains Neutral
(N)) for cabinet door monitoring.
Secondary
USB
2x USB 2.0 host port for
additional devices
SIM CardMicro SIM card is inserted
on top part of the Segment
Control Unit.
Micro SD cardMicro SD card is inserted
on top part of the Segment
Control Unit.
A-Bus1x5 internally connected
signals that are used for
the A-Bus. The internal
connection makes it easier
to daisy-chain to other
controller modules.
RS485Supports multiple baud
rates. Default value is 9600
bps.
DALIDALI master without DALI
Power Supply.
Current SensingPhase current sensing and
leakage current sensing.
Inputs
2x Analog Low voltage measurement
inputs analog input 1 and
analog input 2 (positive
voltage w.r.t. GND).
1x Digital Low voltage input digital
input (posit ive voltage w.r.t.
GND).
Ethernet RJ-45 connector, 100/10
Mbps, half & full duplex,
functional insulated from
the secondary connections.
RS232 interfaceFor use with RS232 power
meters, maximum data
transfer rate 115.2 Kbps.
GPS AntennaInsert the antenna in the
antenna socket of the
Segment Control Unit and
tighten it gently with your
ngers. Do not use tools.
GPRS AntennaInsert the antenna in the
antenna socket of the
Segment Control Unit and
tighten it gently with your
ngers. Do not use tools.
Produc t Guide - LCN7700 3
Page 4
Reliability & Maintainability
Software upgrade/
installation
Multi-layer systemVarious internal processes
System healthIn case a process has failed,
The software on the
Segment Control Unit can
be updated remotely from
the central server. New
software is transferred
without interrupting the
normal functionality of the
Segment Control Unit.
When the software has
been transferred, the
integrity of the software is
checked and the software is
installed.
ensure that the system is up
and running at all times.
it is restarted without
disturbing other processes.
Connections on the secondary side
All cables on secondary side should preferably be
shielded, with the shield connected to GND (pin5 for
the A-Bus).
EU directives
A-Bus cablecable length < 3 m
RS485cable length < 3 m
Use shielded twisted pair
(2x2) cable. The Segment
Control Unit can be
connected to any client
module e.g. AmpLight
RS485, AmpLight Switch.
Double connections on
the A-Bus makes daisy-
chaining of the signals easy.
For detailed information,
see wir ing diagrams.
Self-test A built-in self-test is
performed after power-up.
Installation
The Segment Control Unit should be protected from
dust and water, preferably by enclosing the system in
a metal IP class 65 (NEMA type 4) outdoor cabinet.
Connections on the primary side
Keep wiring short from the mains circuit breaker
towards the mains power input.
When using a surge protection module, the wires
between the surge protection module and the
Segment Control Unit may not exceed 0.15 m.
Philips recommends for outdoor applications to use a
surge protection module.
At least one GROUND connection needs to be
connected to Earth or screwed GPS or 2G/3G antenna
is connected and installed on cabinet.
RoHS with EU directive 2011/65/EC (Philips RSL latest
update)
REACH with EU directive 2006/1907/EC (Philips RSL latest
update)
UL listed
UL 916 for safety
FCC Part 15 Subpart B, FCC PART 22/24 & MPE OET65
FCC Statement
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
Notice:
(1) Changes or modications not expressly approved
by the party responsible for compliance could void
the user’s authority to operate the equipment
(2) The manufacturer is not responsible for any
radio or TV interference caused by unauthorized
modication to this equipment. Such modications
could void the user’s authority to operate the
equipment.
(3) This equipment complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. This equipment must not be colocated or operating in conjunction with any other
antenna or transmitter. The equipment must be
installed to provide a separation distance of at
least 30 cm.
Packing data
TypeBox dimensions
Qty/B ox MaterialBox Weight (kg)
(mm)
netgross
LCN7700 Segment Control Unit 711 x 581 x 159 20 Cardboard 7.7 10.7