Signify 442294730771X User Manual

Interact Pro User Manual
Installation Guide
Setting up a project successfully
LED Lamp
Signify Classified - Internal
Footer (Insert > Header & Footer to edit)2
9290022767
Footer (Insert > Header & Footer to edit)3
Installation Process Flow
Getting Interact Pro Live In 5 Easy Steps
4
Getting Interact Pro Live In 5 Easy Steps
2
Getting Interact Pro Live In 5 Easy Steps
2
Getting Interact Pro Live In 5 Easy Steps
2
Signify Classified - Internal
A ‘robust’ flow from physical install to handover
5
Set up project and first user(s) (service provider/installer)
Install and connect the gateway
Optional: Update the gateway to the latest version
Physical installation of the luminaires and/or lamps
Discover the lights
Assign the lights to groups and/or zones
Add additional users for the appropriate roles
Start ‘Project update’
Physical installation of sensors and switches
Set up behavior by adding switches/sensors and selecting appropriate lighting behavior
Add scenes and schedules as required
Finalize setting up users and handover to the end customer
Intermezzo: On software releases and software updates
Factory new devices firmware will typically lag the most actual software release that is available (production lead
time, stock, …)
One device with an older firmware will trigger the need for a firmware upgrade
Minimum upgrade time is at least 1 hour irrespective of the amount of lights (1..200).
The upgrade time may extend up to 4 hours (or even longer)
Current factory release is dated and limits the functionality that can be used out of the box: that will require a
firmware upgrade of both gateway and lights which is a time consuming operation so it has to be planned for in the
install process.
Factory gateway release does match factory lamp/luminaire devices releases for out-of-the box installs.
It will allow you to group lights and control them via the app (min. functionality).
Factory releases can always be upgraded to the latest release
Factory releases will be updated but be aware that one device with a previous release will require update to be
executed.
6
System limitations out of the box / after upgrade
7
Feature
Out of the box
After upgrade
Limits
Max lights / lamps
200 / 150
200 / 200
Max sensors
15
30
Max switches
15
50#
Type of sensor
OCC
OCC, DL-
OCC
Light control
manual on manual off
*
*
Auto on auto off
*
*
Manual on auto off
*
*
Auto on auto off with DDR
*
Manual on auto off with DDR
*
Other features
Force delete
*
Reconnect to project after reset gateway
*
#Max switches equals 50 minus 'number of sensors'
System limitations out of the box / after upgrade
8
Feature
Out of the box
After upgrade
Limits
Max lights / lamps
200 / 150
200 / 200
Max sensors
15
30
Max switches
15
50#
Type of sensor
OCC
OCC, DL-
OCC
Light control
manual on manual off
*
*
Auto on auto off
*
*
Manual on auto off
*
*
Auto on auto off with DDR
*
Manual on auto off with DDR
*
Other features
Force delete
*
Reconnect to project after reset gateway
*
#Max switches equals 50 minus 'number of sensors'
A gateway update to the latest version prior to discovery of lights will enable
Force delete
Reconnect to same project after reset of gateway
But you will get ‘update project’ messages after finding lights
As the system wants to enforce consistent versions
Best to do this when all lights are accounted for
Loading...