Signet 1ZDM Operation & Instruction Manual

Page 1 of 4 DocNo.DCP0001330 RnB 25/02/04 rev2
Operation Instruction Manua
l
1ZDM
Single Zone Desk Microphone
Features
The 1ZDM has compressor, noise gate, equalisation controls and optional chime (one to three note).
The unit is fully monitored and complies with BS5839 part4. Simple operation by the use of a single button Speak bar. The unit is supplied in a sturdy plastic desk mounting case
with a gooseneck microphone fitted.
Technical Description
Microphone signals are passed to a voltage controlled amplifier under control of a signal derived from rectifying the stage output signals, providing 3:1 compression ratio.
The output of this stage is fed to an LED output level display and a three-band equaliser (100 Hz, 1KHz, 10 kHz).
Power is supplied at nominal 24 VDC via separate cabling, the phantom power on the audio + and audio - being used for fault detection only. A regulator circuit provides 15 VDC for powering the 1ZDM electronics.
Front Panel Features
The 1ZDM provides for the following LED indications:
Name Function / Description
1
OK GREEN when no fault detected.
2
FAULT AMBER when fault detected.
3
SPEAK GREEN when system ready for paging announcement, FLASHING GREEN when system is
busy.
4
VU VU meter to show audio level. VU meter is constantly active and will light in sync with audio
peaks to indicate that the audio path to the input stage is intact. This occurs even when speak bar is not pressed.
Block Diagram
Page 2 of 4 DocNo.DCP0001330 RnB 25/02/04 rev2
Installation
Unpacking Upon receipt of shipment, please inspect for any damage incurred in transit. If damage is
found, please notify your local representative and the transport company immediately. State date, nature of damage and whether any damage was noticed on the shipping container prior to unpacking. Please give the waybill number of the shipping order.
The unit should not be placed in areas;
1 with poor ventilation 2 exposed to direct sunlight 3 with high ambient temperature or adjacent to heat generating equipment 4 with high humidity or dust levels 5 susceptible to vibration
Operation
The 1ZDM has been designed to offer a simple microphone input to the network, with the choice of either local operation or global all call operation. This function is selected on set up of the network system. This unit can also be used in the SigNET LinX voice alarm systems.
The microphone console comprises of a gooseneck, microphone, speak bar, VU Meter, and two status indicators, one for OK and one for fault.
In order to page, the thumb switch on the microphone or the speak bar are pressed, and if the system is able to accept paging, the speak bar will light solid green and paging may commence.
The speak bar LED indicator will flash if there is a busy input indicating that an equal or higher priority input to the system is in use on one of the selected zones, or that access to one of the selected zones is excluded. If the zone selection is valid, the busy in will permit the speak bar to illuminate steadily and the announcement can be made.
Fault monitoring
The electret microphone capsule is monitored for impedance and current absorption. Any deviation from preĀ­set windows triggers the monitor circuit with the following results:
1. The OK LED is extinguished and the Fault LED illuminated.
2. The monitor circuit removes the 6K8 termination of the PTT. This puts an open circuit condition on the PTT line, signalling a fault to external control equipment.
The audio lines are monitored by the phantom detect circuit which notifies any loss of the 15V phantom (due to an open circuit or short circuit line) to the monitor circuit. The monitor circuit causes an open circuit condition to be set on the PTT, signalling a fault to signalling a fault to external control equipment.
DC power operation
The 1ZDM requires a 24V DC supply which enters the unit through the six core cabling (see page 5).
Caution
This unit must never be directly connected into a 230V AC power supply.