SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
This guide contains many important safety messages. Always read and obey all safety messages.
This is the safety alert symbol. It alerts you to safety messages that inform you of hazards that can kill or hurt you or others or cause damage to the product.
All safety messages will be preceded by the safety alert symbol and the hazard signal word WARNING, or CAUTION. These words mean:
WARNING
CAUTION
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
You may be killed or seriously injured if you don’t follow instructions.
Indicates an imminently hazardous situation which, if not avoided, may result in minor or moderate injury, or product damage.
WARNING
TIP-OVER HAZARD
Use two or more people to move and install the refrigerator. To prevent the refrigerator from tipping over, install anti-tip brackets (provided). Failure to follow the refrigerator installation instructions can result in serious injury or death.
WARNING
the product, basic safety precautions should be followed, including the following. Read all instructions before using this appliance.
Installation
risk of tipover, personal injury, and product or property damage.
ventilated area.
product malfunction.
during installation and frequent use.
operation and use without twisting or deforming.
bending. The product must be level both horizontally and vertically.
Electrical Connection
Use a dedicated outlet.
Plug in the power plug with the power cord facing downward.
When installing or moving the refrigerator, be careful not to roll over or damage the power cord. Do not squeeze or crush the cord or plug when pushing the refrigerator in.
Do not allow the power cord to be bent, crushed, or damaged. Do not run the power
Do not extend or modify the length of the power cord.
Turn off the power before cleaning or moving the refrigerator.
Do not pull out the cord or touch the power plug with wet hands.
Remove water or dust from the power plug and insert it securely into the wall socket.
Do not unplug the refrigerator by pulling on the cord.
Do not use the power cord or the power plug if it is damaged or if the outlet is damaged.
Wait for 5 minutes or longer when reconnecting the plug or turning the power back on.
Give the compressor time to cycle before restarting.
If the supply cord is damaged, it must be replaced by the manufacturer or its service
CAUTION
Do not remove the cover of the automatic ice dispenser.
The internal mechanism of the icemaker can cause injury if handled.
Do not stick your hands under the refrigerator.
Sharp edges, fans, and wires may cause an injury
Save these instructions for the local inspector's use.
Observe all governing codes and ordinances.
Installer: Leave these instructions with the consumer.
Consumer: Keep these instructions with the owner's manual for future reference.
General
electrical power and grounding must comply with local codes and ordinances and be made by licensed personnel when required. In the absence of a local code:
Appliance is very heavy:
Before Installation
WARNING
Choosing the Install Location
Temperature and Humidity
The appliance should be installed in a dry, well ventilated area.
tions.
oven or radiator.
-
Anti-tip Devices
WARNING: Tip Hazard
securely installed.
installing the appliance in a stable position is to use the supplied anti-tip devices.
If the enclosure is sturdy enough, attaching the appliance to the upper and side walls of the enclo-
If in doubt, contact an architect or structural engineer.
Enclosure
nals of the opening to make sure corners are square.
cabinets. Make sure the enclosure or the adjacent cabinets are securely connected to the
Floor
WARNING
mance.
-
-
-
Electrical Requirements
WARNING
The receptacle must be installed by a licensed electrician only.
Grounding
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for the electric current. WARNING: Improper connection of the equipment grounding conductor may result in electric
if you are in doubt as to whether the appliance has been properly grounded.
NOTE
Some local regulations may require a separate ground. In such cases, the required ground wire, clamp and screw are available as a separate accessory and must be purchased sepa­rately. Never ground the appliance to plastic plumbing lines, gas lines or water pipes.
Water Connection
CAUTION
ily accessible.
-
-
SKSCF1801P – 18" INTEGRATED FREEZER COLUMN
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
NOTE
depth adjacent cabinets.
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation. The water pressure must be between 20 and 120 psi.
date a bend leading into the water line connection.
Install a shut-off valve between the icemaker water valve and the cold water supply in the home.
-
INSTALLATION CLEARANCES
NOTE
The installation must allow for clearances to adjacent walls or cabinets. This freezer is equipped with a 2-position door stop.
restricted.
The door handle depth must be added to the dimension where noted to determine the total clearance required from adjacent cabinets or walls. This clearance will vary depending on the custom handle used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite stainless steel door panel kit with handles (optional accessories), the door handle clearance with the door
SKSCF2401P – 24" INTEGRATED FREEZER COLUMN SKSCR2401P – 24" INTEGRATED REFRIGERATOR COLUMN
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
NOTE
depth adjacent cabinets.
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation. The water pressure must be between 20 and 120 psi.
accommodate a bend leading into the water line connection.
Install a shut-off valve between the icemaker water valve and the cold water supply in the home.
INSTALLATION CLEARANCES
NOTE
equipped with 2-position door stops.
restricted.
The door handle depth must be added to the dimension where noted to determine the total clearance required from adjacent cabinets or walls. This clearance will vary depending on the custom handle used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite stainless steel door panel kit with handles (optional accessories), the door handle clearance with the door open
SKSCF3001P – 30" INTEGRATED FREEZER COLUMN SKSCR3001P – 30" INTEGRATED REFRIGERATOR COLUMN
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
NOTE
mm) depth adjacent cabinets.
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
The water pressure must be between 20 and 120 psi.
commodate a bend leading into the water line connection.
Install a shut-off valve between the water valve and cold water supply in the home.
-
INSTALLATION CLEARANCES
NOTE
ance to adjacent cabinets or walls is restricted.
The door handle depth must be added to the dimension where noted to determine the total clear­ances required from adjacent cabinets or walls. This clearance will vary depending on the custom handle used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite stainless steel door panel kit with handles (optional accessories), the door handle clearance with the door
-