TCL, PHX & PHXF SERIES -
Static Message Smart Signs
Wiring Instructions
Voltage
This sign operates within an input range of 120VAC to 277VAC.
IMPORTANT: Complete the Smart Sign Install Log before installing each Smart Sign.
How to complete the Smart Sign Install Log:
1. Write in the Facility Location
2. Write in the specic sign location at the facility
3. Remove the Product ID# and MAC address sticker from the inside sign and place next to the sign
location on the chart
4. Repeat for each Smart Sign being installed at that facility location
Completing the Smart Sign Install Log is CRITICAL to proper
Smart Sign and Sign Control Software setup and conguration.
Installation Setups:
1. Turn o the power prior to starting the installation
2. Follow the standard wall mount instructions to attach sign to the structure
3. Connect the Ethernet network connection and power connection to the sign shown below
4. Sign will not illuminate until schedule is set up in the software or a manual override message
is sent to the sign
Note: For messages to display on the sign, the network DHCP must be set
before power is restored to the sign. If power is restored prior to this occuring,
the sign power MUST be recycled for the network to recognize the sign.
Factory Sign Wiring
Network
Connection
GC XPort ENH
00-08-AV-CW-D8-Z3
MAC
Address
Typical Smart Sign Wiring Diagram
• Wire color Black/White Stripe
Input range of 120 to 277VAC
Neutral
120 - 277VAC
Line
SPST
On/Off
Switch
Sign Cabinet Ground (Green Wire)
Used on Aluminum Cabinets ONLY
Wire
connector
Message A Lead (Black / White Stripe)
Neutral
Neutral (White Wire)
Power
Connection
Power Supply Pigtail
10/24/2018

TCL, PHX & PHXF SERIES -
Installation Instructions
Installation Steps
Static Message Smart Signs
Using a Phillips head screw driver, remove the two screws on the bottom
1.
of the cabinet. With the screws removed the back will lift o the cabinet.
Remove the four mounting knockouts and the center knockout for your
power conduit.
Phillips Head
Screws
Hinged Lip
Back Panel
Knockouts
Sign Cabinet
Place the back panel on the wall surface using a level to make sure it’s
2.
straight. Use a pencil to mark the locations of the mounting holes on
your wall surface. Drill your wall surface. The diameter of the (4) four
corner mounting knockouts is 1/4” and the conduit knockout is 7/8”.
Phillips Head
Screws
Pull your electrical through the back panel and attach the back to the wall
3.
surface using appropriate fasteners.
Wall Surface
Back Panel
Be sure any metal
debris cleared
out of the cabinet.
Mounts to Surface
Make your electrical wiring connections. See the other side of this page.
4.
With the electrical connections made, hang the sign cabinet on the lip of the
5.
back panel you mounted to the wall. Finish your electrical connection to the
sign by reinstalling the pigtail connector to the power supply. The connector
is “keyed” and can only be installed in one orientation. Close the cabinet and
replace the two Phillips head screws you removed in step one.
Pivot Point
Cabinet
Fasteners
(Not Included)
Sign Back
Sign
Cabinet Hangs on
Lip of Back Panel
Wall Surface