With the aid of the interface between the
SIGMA ROX 9.0 and
your PC, you can transfer
the logged data or the trip and total values to
your PC.
To do this you have to attach the docking
station to your PC and install the software
supplied for this purpose.
Using the SIGMA SPORT
®
software, you can
perform the following actions:
3Set all functions on the SIGMA ROX 9.0
with the aid of the PC
3Check the battery status of all the parts
to the appliance
8.1 SYSTEM REQUIREMENTS
Minimum:
3Intel
®
Pentium® processor with at least
1 GHz
3 Microsoft
Service Pack 4, Windows
Service Pack 2 or Windows Vista
®
Windows® 2000 with
®
XP with
®
3 256 MB RAM
3Download
the saved data (memory,
total values and logged data) as
®
a SIGMA SPORT
file or as an export
format.
3Show the saved data in table or graphic
form
3Compare 2 rides
3Analyse the distances cycled
Please find further details about the software
on the online software help section.
Recommended:
3 Intel
®
Pentium® processor with at least
2 GHz
3 Windows
Windows
or Windows Vista
®
2000 with Service Pack 4,
®
XP with Service Pack 2
®
3 512 MB RAM; 32 MB VRAM
72
www.sigmasport.com
8 PC INTERFACE/SIGMA DATA CENTER
8.2 INSTALLING THE SIGMA DATA CENTER
Before installation, you should close all
1.applications that are running.
2. Place the installation CD in your CD drive.
3. Installation starts automatically.
Alternatively, select your CD drive and
start “setup.exe” manually.
4. Follow the installation instructions on the
screen.
8.3 INSTALLING THE DOCKING STATION
Note: Be
fore connecting the docking station
to your PC, you must have installed the
software supplied. See also Section 8.2
“Installing the SIGMA DATA CENTER”.
1. Connect the docking station supplied to
a free USB port on your PC.
2. Your operating system will automatically
detect new hardware and install the
appropriate driver.
3. Should automatic installation fail, you can
also install the driver manually using your
Device manager. You will find the driver file
on the SIGMA installation CD in the
“Drivers” directory.
Adobe “Air Framework” is required to
5.perform the SIGMA DATA CENTER. This is
automatically installed at the same time.
Please follow the instructions for Adobe
“Air Installation”.
6. Once the installation has finished, you can
remove the CD.
You can find further information about the
“SIGMA DATA CENTER” functions in the
program’s online help section.
4. Windows warns you about an uncertified
driver. Please confirm this window by
clicking “Continue installation”.
5. Start the analysis software and click on
the “connect” button to integrate your
SIGMA ROX.
6. Twist your SIGMA ROX onto the docking
station. The software recognises your
appliance automatically and switches to
“connected” mode (green light on the
docking station).
7. Follow the instructions in the software.
GB/USA
ROX 9.0
73
9 IMPORTANT NOTES/TROUBLESHOOTING/FAQ
9 IMPORTANT NOTES/TROUBLESHOOTING/FAQ
9.1 IMPORTANT NOTES
9.1.1 WATER-TIGHTNESS OF THE SIGMA ROX 9.0
The SIGMA ROX 9.0 is water resistant, which
means that the cyclist can ride in the rain
without any risk to the computer. The buttons
may also be pressed in rainy conditions.
Should water get into the interior of the
9.1.2 CARE OF THE CHEST BELT
Clean the chest belt with mild soap after each
use.
Avoid caustic cleaning agents or those
containing alcohol, as they are harmful to the
material and can reduce the chest belt‘s life
span.
SIGMA ROX 9.0, please remove the battery
and dry it on a radiator, for example. After
drying the unit and re-installing the battery,
the SIGMA ROX 9.0 is ready for the road
again.
Always keep the chest belt dry. Avoid storing
the chest belt when damp in plastic bags or
closed sports bags. This can lead to a shorter
battery life, as the chest belt remains active
due to the dampness.
9.1.3 TRAINING TIP
Consult your doctor before beginning
any exercise program.
This is particularly
important if you have underlying
cardiovascular problems.
74
www.sigmasport.com
For people with pace makers, we recommend
checking the compatibility of the SIGMA
ROX 9.0 and your pace maker with your
doctor before using the chest belt.
9 IMPORTANT NOTES/TROUBLESHOOTING/FAQ
9.2 TROUBLESHOOTING
No speed display
3Is the computer correctly clicked onto
the bracket?
3Have you checked the contacts for
oxidation/corrosion?
3Have you checked the magnet/transmitter
distance (max. 12 mm)?
3Have you checked whether the magnet
is magnetized?
3Have you checked the battery status on
the speed transmitter?
No cadence display
3Have you checked the magnet/transmitter
distance (max. 12 mm)?
3Have you checked whether the magnet
is magnetized?
3Have you checked the battery status on
the transmitter?
No pulse display
3Are the electrodes damp enough?
3Have you checked the battery status?
No display
3Have you checked the battery status on
the SIGMA ROX 9.0?
3Is the battery inserted correctly
(+ facing up)?
3Are the battery contacts ok? They
should be raised approx. 30 degrees.
(If not, bend carefully)?
Wrong speed display
3Are 2 magnets fitted?
3Is the magnet correctly positioned
(parallel to the transmitter and centered
with the transmitter)?
3Is the wheel circumference set correctly?
3Is the transmitter set on the right bicycle
(bicycle I or II)?
Display black/dull
3Is the temperature too high (> 60°C)
or too low (< 0°C)?
No synchronization
3Have you checked the magnet/
transmitter(s) distance?
3Is/are the battery/batteries on
the transmitter(s) empty?
3Have you checked the range on the
respective transmitter?
3When using a hub dynamo, please change
the position of the transmitter.
Display “TOO MANY SIGNALS”
3Please increase the distance to the other
transmitters and press any button.
GB/USA
ROX 9.0
75
9 IMPORTANT NOTES/TROUBLESHOOTING/FAQ
9.3 FAQ (FREQUENTLY ASKED QUESTIONS)
Can I change the batteries myself?
All parts on the SIGMA ROX 9.0 are designed
with a battery compartment that makes it
possible for the user to change the battery.
When doing so, please make sure that the
sealing ring is always correctly positioned
before closing the battery compartment.
Can another person with another bicycle
computer/heart rate monitor cause
interference?
The digital transfer system is encoded.
This almost completely rules out mutual
interference between two units. When
synchronizing the receiver with the
transmitter, make sure that there are
no other SIGMA ROX units nearby.
How long does the battery last in the
transmitter, receiver?
The battery life depends on how often the
unit is used and on the use of the light
manager. As a rule, all the parts on the SIGMA
ROX 9.0 – receiver and all 3 transmitters –
are designed so that the battery lasts at least
1 year (based on 1 hour‘s use per day).
The altitude changes even though I remain
at the same location, why?
The altitude measurement on the SIGMA
ROX 9.0 is based on a barometric altitude
measurement. As the barometric pressure
changes continually, this can lead to a change
in the current altitude, even though you are
not moving. However, the SIGMA ROX 9.0
is equipped with a system that freezes the
current altitude when the unit goes into
sleep mode. We can therefore guarantee
a constant, current altitude, provided the
unit is not regularly moved.
Why do I always have to calibrate the
current altitude?
As we use the barometric pressure to
determine the current altitude, the continual
changes in the current air pressure lead
to changes in the current altitude. To
compensate for these continual changes
and to achieve a current altitude reading that
is accurate to within 1 meter, a reference
altitude should be entered in the SIGMA
ROX 9.0 before every ride. Inputting the
reference altitude is called calibration.
Is the transmission system compatible
with the DTS system?
The transmission system on the SIGMA
ROX 9.0 has been developed separately from
the existing DTS system and therefore is not
compatible.
76
www.sigmasport.com
10 BATTERY CHANGE
10 BATTERY CHANGE
The battery status on the unit and that of
the respective transmitter is conveyed
to the
Please refer to the enclosed sheet for how to
change the battery on the relevant units.
receiver shortly before the battery life comes
to an end. The display looks like this:
11 TECHNICAL DATA
11.1 MAX/MIN/DEFAULT VALUES
Unit Default Min. Max.
GB/USA
Bike
Speed kmh/mph 0,0 0,0 199.8/119.8
Distance km/mi 0,0 0,0 9,999.99
Ride Time hh:mm:ss 00:00:00 00:00:00 999:59:59
Average speed kmh/mph 0,0 0,0 199.8/119.8
Maximum speed kmh/mph 0,0 0,0 199.8/119.8
Separate distance counter (+/-) km/mi 0,0 -99.99 999.99
Current cadence rpm 0 0 180
Average cadence rpm 0 0 180
Maximum cadence rpm 0 0 180
ROX 9.0
77
11 TECHNICAL DATA
11.1 MAX/MIN/DEFAULT VALUES
Unit Default Min. Max.
Heart rate
Current heart rate bpm 0 40 240
% of max. HR % 0 17 150
Average heart rate bpm 0 40 240
Maximum heart rate bpm 0 40 240
Time in the training zone hh:mm:ss 00:00:00 00:00:00 99:59:59
Calories burnt kcal 0 0 99,999
Temperature
Actual/Min./Max. temperature °C/°F Act. Temp. -10.0/14.0 +70.0/+158.0
HR Zone 2 - Threshold bpm 135 Zone 1 Zone 3
lower +5 lower -5
GB/USA
HR Zone 3 - Threshold bpm 154 Zone 2 Zone 3
lower +5 upper -5
Total values
Total distance bike 1/2 km/mi 0 0 99,999
Total time bike 1/2 hh:mm 00:00 00:00 9.999:59
Total calories burnt bike 1/2 kcal 0 0 999,999
Total altitude difference bike 1/2 m/ft 0 0 999,999
Maximum altitude bike 1/2 m/ft 0 0 4,999/9,999
Total distance
uphill/downhill bike 1/2 km/mi 0 0 999,999
Total time
uphill/downhill bike 1/2 hh:mm 00:00 00:00 9.999:59
ROX 9.0
79
11 TECHNICAL DATA
11.2 TEMPERATURE/BATTERIES
3Bicycle computer
Ambient temperature +60°C/-10°C
Battery type CR 2450 (Art. No. 20316)
3Speed transmitter
Ambient temperature +60°C/-10°C
Battery type CR 2032 (Art. No. 00396)
12 GUARANTEE/WARRANTY
In the US, Canada, or Mexico:
Every SIGMA product h
as a production code
stamped on the back. SIGMA USA will replace
any defective computer or HRM within two
years of production WITH NO HASSLES. If
a claim is made after the two year period,
SIGMA USA will replace product up to 5 years
with proof of purchase. If proof of purchase
is not available, SIGMA will repair or replace
defective products at a reasonable price.
All batteries are excluded from warranty
coverage. If you feel that you have a product
in need of repair/replacement, please contact
a customer service representative at SIGMA
USA to obtain a “Return Authorization
Number” prior to sending your SIGMA
ROX 9.0.
3Cadence transmitter
Ambient temperature +60°C/-10°C
Battery type CR 2032 (Art. No. 00396)
3Chest belt
Ambient temperature +60°C/-10°C
Battery type CR 2032 (Art. No. 00396)
In the US, Canada, or Mexico contact:
SIGMA SPORT USA
North America
1067 Kingsland Drive
Batavia, IL, 60510, U.S.A.
In case of a justified warranty claim, you will
receive a replacement unit. You are only
entitled to the current model at the time of
the return. The manufacturer reserves the
right to make technical changes to all SIGMA
products.
80
www.sigmasport.com
NOTICES
GB/USA
ROX 9.0
81
TABLE DES MATIERES
1 Préface et contenu ........................................................................................................................... 84
2 Montage du SIGMA ROX 9.0 et de ses accessoires ............................................................. 85
2.1 Montage du support ................................................................................................................................. 85
2.2 Montage des émetteurs – Vitesse et cadence ............................................................................... 85
2.3 Montage des aimants – Vitesse et cadence .................................................................................... 85
2.4 Montage du SIGMA ROX 9.0 sur le support .................................................................................... 85
2.5.1 Synchronisation de la vitesse ................................................................................................................ 86
2.5.2 Synchronisation de la cadence ............................................................................................................. 86
2.5.3 Synchronisation de la ceinture thoracique ........................................................................................ 86
3 Tout sur le SIGMA ROX 9.0 ........................................................................................................... 87
3.1 Première mise en service ....................................................................................................................... 87
3.2 Principe de navigation du SIGMA ROX 9.0 ....................................................................................... 87
3.3 Fonction des touches ............................................................................................................................... 88
3.4 Structure de l’écran - Fonctions ........................................................................................................... 88
3.4.1 Bloc supérieur de la matrice DOT ........................................................................................................ 89
3.4.2 Segment central/Affichage des icônes ............................................................................................. 90
3.4.3 Bloc inférieur de la matrice DOT .......................................................................................................... 90
3.5 Aperçu des fonctions du SIGMA ROX 9.0 ......................................................................................... 91
3.6 Fonctions et propriétés du SIGMA ROX 9.0 ..................................................................................... 92
3.6.1 Etendue des fonctions ............................................................................................................................. 92
3.6.2 Détecteur de mouvement ....................................................................................................................... 92
3.6.4 Masquage des valeurs pendant le tour .............................................................................................. 93
3.6.5 Enregistrement de données .................................................................................................................. 93
3.6.6 Interface PC ................................................................................................................................................ 94
4 Mise en service ................................................................................................................................. 94
4.1 Arrêt du “mode veille” .............................................................................................................................. 94
4.2 Etendue des fonctions du SIGMA ROX 9.0 ....................................................................................... 94
5 Description de fonctionnement (fonctions disponibles pendant le tour) . ........................ 95
5.1 Favorits A et Favorits B ........................................................................................................................... 95
5.7 Fonction Temps ...........................................................................................................................................99
5.8.1 Gestion de l’éclairage ............................................................................................................................ 100
5.8.2 Calibrage de l’altitude ........................................................................................................................... 101
82
www.sigmasport.com
TABLE DES MATIERES
6 Utilisation du SIGMA ROX 9.0 ...................................................................................................
102
6.1 Favorits A et B ......................................................................................................................................... 102
6.2 Fonction Journal de bord ..................................................................................................................... 102
7.7 Favorits A et B ......................................................................................................................................... 109
7.7.1 Favorits A .................................................................................................................................................. 109
7.7.2 Favorits B .................................................................................................................................................. 109
8 Interface PC/SIGMA DATA CENTER ....................................................................................... 112
8.1 Prérequis système ................................................................................................................................. 112
8.2 Installation du SIGMA DATA CENTER .............................................................................................. 113
8.3 Installation de la station de connexion ............................................................................................. 113
9 Autres remarques/Elimination des erreurs/FAQ ............................................................... 114
9.1 Remarques importantes ...................................................................................................................... 114
9.1.1 Etanchéité du ROX 9.0 ......................................................................................................................... 114
9.1.2 Entretien de la ceinture thoracique .................................................................................................. 114
9.1.3 Conseil pour l’entraînement ................................................................................................................ 114
9.2 Elimination des erreurs ........................................................................................................................ 115
Nous vous remercions d’avoir choisi un
compteur de marque SIGMA SPORT
®
. Votre
nouveau SIGMA ROX 9.0 sera tout au long
de l’année un compagnon fidèle lors de vos
sorties à vélo. Pour apprendre les nombreuses fonctions de votre nouveau compteur
et les utiliser, veuillez lire le présent mode
d’emploi attentivement. SIGMA SPORT
®
espère que vous prendrez beaucoup de
plaisir en utilisant votre SIGMA ROX 9.0.
Le SIGMA ROX 9.0 est un compteur multifonction vous fournissant un grand nombre
d’informations pendant et après votre tour :
1.2 CONTENU
3Compteur
SIGMA ROX 9.0
3Informations relatives à votre parcours –
Vitesse, durée, distance, etc.
3Informations relatives au lieu où vous
vous trouvez – Altitude, montée, etc.
3Informations relatives à vos données
personnelles – Fréquence cardiaque,
zones d’entraînement, etc.
3Transfert de toutes les informations sur
le PC permettant une représentation
graphique simple des résultats de votre
tour.
3Emetteur de
cadence
84
3Emetteur de
vitesse
www.sigmasport.com
3Ceinture
thoracique,
sangle élastique
incl.
1 PREFACE ET CONTENU DE L’EMBALLAGE
1.2 CONTENU
3Support3Station de
connexion
3Matériel de
fixation
3CD du logiciel
d’évaluation
SIGMA
DATA CENTER 1.0
SOFTWARE CD
2 MONTAGE DU SIGMA ROX 9.0 ET DE SES ACCESSOIRES
Les illustrations relatives aux instructions de montage sont reprises sur le dépliant joint !
2.1 MONTAGE DU SUPPORT
3Guidon ou cadre
3Retirer le f
ilm jaune
2.2 MONTAGE DES EMETTEURS – VITESSE ET CADENCE
3Les deux émetteurs peuvent être montés au moyen de rislan
(montage permanent) ou de caoutchoucs.
3Pour atteindre les 12 mm ou moins nécessaires, montez l’émetteur
et les aimants plus près du moyeu.
F
5432
9876
13121110
161514
2.3 MONTAGE DES AIMANTS – VITESSE ET CADENCE
2.4 MONTAGE DU SIGMA ROX 9.0 SUR LE SUPPORT
ROX 9.0
191817
20
85
2 MONTAGE DU SIGMA ROX 9.0 ET DE SES ACCESSOIRES
2.5 SYNCHRONISATION
Monté, le SIGMA ROX 9.0 est prêt à être
synchronisé avec les différents émetteurs –
vitesse, cadence et fréquence cardiaque –
dès que vous quittez le mode veille.
Lors de la synchronisation avec l’émetteur
de vitesse, l’affichage de la vitesse clignote
à l’écran. Dès que l’affichage ne clignote plus,
le SIGMA ROX 9.0 est synchronisé avec
2.5.1 SYNCHRONISATION DE LA VITESSE
Il existe 2 possibilités :
3Démarrer ; en règle générale, le récepteur
se synchronise avec l’émetteur après
3 rotations de la roue.
l’émetteur de vitesse et indique la vitesse
actuelle. L’émetteur de cadence et la ceinture
thoracique se synchronisent automatiquement
en parallèle. Dans les menus favorits (A et/
ou B), les différentes valeurs s’affichent dans
le bloc supérieur de la matrice DOT dès que la
synchronisation correspondante est terminée.
3Faire tourner la roue avant jusqu’à ce que
l’affichage KMH ne clignote plus.
2.5.2 SYNCHRONISATION DE LA CADENCE
Il existe 2 possibilités :
3Démarrer ; en règle générale, le récepteur
se synchronise avec l’émetteur après
3 rotations des pédales.
2.5.3 SYNCHRONISATION DE LA CEINTURE THORACIQUE
Mettre la ceinture thoracique en place.
Se déplacer à proximité du SIGMA ROX 9.0
ou monter sur le vélo.
En règle générale, le SIGMA ROX 9.0 se
86
www.sigmasport.com
3Déplacer les pédales vers le bas et vers
le haut jusqu’à ce que la cadence s’affiche.
synchronise avec la ceinture thoracique en
moins de 10 secondes.
La fréquence cardiaque actuelle apparaît
à l’écran.
3 TOUT SUR LE SIGMA ROX 9.0
3 TOUT SUR LE SIGMA ROX 9.0
3.1 PREMIÈRE MISE EN SERVICE
A la livraison, le SIGMA ROX 9.0 se trouve
dans un mode dit de “veille profonde”. Pour
choix appuyée pendant 5 secondes. Suivez
ensuite les indications apparaissant à l’écran.
quitter ce mode, maintenez une touche au
6
Maintenir une touche
au choix appuyée
pendant 5 secondes.
Sélectionner la langue souhaitée
avec les touches +/- et
enregistrer avec “SAVE”.
6
3.2 PRINCIPE DE NAVIGATION DU SIGMA ROX 9.0
Le SIGMA ROX 9.0 comprend jusqu’à
5 niveaux de menu.
Lors de la navigation
dans les menus et les sous-menus du SIGMA
ROX 9.0, toujours se baser sur l‘aperçu des
fonctions au chapitre 3.5.
3pour revenir au niveau supérieur précédent
(BACK),
3pour accéder à un autre niveau du menu
Réglages (NEXT),
3pour confirmer / enregistrer un réglage
(SAVE/DONE).
La gestion des menus du SIGMA ROX 9.0
est fortement simplifiée grâce à un niveau
de navigation. Appuyez une fois sur une des
deux touches de fonction supérieures pour
Confirmez la fonction affichée dans le niveau
de navigation dans les deux secondes en
appuyant à nouveau.
faire apparaître automatiquement le niveau
de navigation. Dans ce niveau, les différentes
fonctions possibles pour les deux touches
supérieures s’affichent :
3pour accéder au niveau inférieur suivant
(ENTER),
Ce niveau de navigation est activé de série
dans le SIGMA ROX 9.0. Lorsque ce niveau
de navigation n’est plus utile après un grand
nombre d’utilisations du SIGMA ROX 9.0,
celui-ci peut être désactivé dans le menu
Réglages.
F
6
L’affichage passe
au menu principal
“Favorits A”.
ROX 9.0
87
3 TOUT SUR LE SIGMA ROX 9.0
3.3 OCCUPATION DES TOUCHES
Touche de fonction 1
Cette touche permet de quitter
les sous-menus ou d’enregistrer
les valeurs réglées.
Touche de fonction
Journal de bord
Entrer dans le journal
de bord
Cette touche permet
d’ouvrir le menu du journal
de bord et de définir les
points du trajet.
Touche de fonction 2
Cette touche permet d’accéder aux
sous-menus ou passer à l’affichage
à quatre lignes supérieur.
Touche de fonction Moins
Revenir en arrière dans
un niveau du menu...
… ou diminuer/modifier
la valeur affichée
3.4 STRUCTURE DE L’ÉCRAN – FONCTIONS
L’affichage de l’écran du SIGMA ROX 9.0 est subdivisé en 3 zones
principales :
REC
88
www.sigmasport.com
Touche de fonction Plus
Avancer dans un niveau
du menu...
… ou augmenter/modifier
la valeur affichée
3 TOUT SUR LE SIGMA ROX 9.0
3.4.1 BLOC SUPERIEUR DE LA MATRICE DOT
Ce bloc reprend différentes informations en fonction du menu dans lequel vous vous trouvez.
3.4.1.1 FAVORITS A ET B
Jusqu’à 4 valeurs actuelles peuvent être affichées ici :
3Altitude actuelle (en permanence)
3Montée (en permanence)
3Fréquence cardiaque actuelle (uniquement lorsque
la ceinture thoracique est utilisée)
3Cadence actuelle (uniquement lorsque l’émetteur
de cadence est monté).
En appuyant sur la touche en haut à droite, vous pouvez modifier
l‘affichage, de sorte qu’une seule de ces 4 fonctions soit encore
affichée.
F
3.4.1.2 NIVEAU DE NAVIGATION
Lorsque cette fonction est activée, le niveau de navigation apparaît
toujours lorsque vous appuyez une f
ois sur une des deux touches
de fonction supérieures. Les fonctions possibles pour les touches
s’affichent dans le niveau de navigation. Après vous être familiarisé avec l’appareil et ses fonctions, il est possible de désactiver
le niveau de navigation dans le point de menu “Régler” (Régler/
Compteur/Info touches).
3.4.1.3 BARRE D’INFORMATIONS
Le bloc supérieur de la matrice DOT, c’est-à-dire la “barre
d’inf
ormations”, vous aide à vous orienter dans les niveaux. Ceci
est valable pour les niveaux suivants du menu : “Valeurs tour”,
“Temps”, “Mémoire”, “Régler”. Le menu principal s’affiche dans
la partie supérieure de l’écran ; le sous-menu dans lequel vous
vous trouvez apparaît dans la partie inférieure.
ROX 9.0
89
3 TOUT SUR LE SIGMA ROX 9.0
3.4.2 SEGMENT CENTRAL/AFFICHAGE DES ICÔNES
Cet affichage segment vous indique, par exemple, la vitesse
actuelle.
Les symboles suivants sont visibles dans cette partie de l’écran :
Symbole - Vélo I/Vélo II
Comparaison de la vitesse par rapport
à la vitesse moyenne
Unité réglée
(km/h ou mp/h)
Chronomètre actif
Compte à rebours actif
Réveil actif
Journal de bord actif
REC
3.4.3 BLOC INFÉRIEUR DE LA MATRICE DOT
La fonction active sélectionnée s’affiche dans ce bloc,
indépendamment du menu/sous-menu dans lequel vous
vous trouvez.
90
www.sigmasport.com
3 TOUT SUR LE SIGMA ROX 9.0
3.5 APERCU DES FONCTIONS DU SIGMA ROX 9.0
Favorits A
Favorits B
Valeurs tourCycle
Temps
Mémoire
GénéralitésCycle
Fréquence
cardiaque
7 Parcours
Parcours
o
1…
n
MontéeDescente
Fréquence
Température
cardiaque
TempératureMontéeDescente
Valeurs
totales
Cycle
MontéeDescente
Fréquence
cardiaque
Fichier 1Fichier 2
Fichier X
F
Logbook
RéglerCompteurVélo I+II
Valeurs
totales
Cycle
MontéeDescente
Fréquence
cardiaque
Réglages
d‘origine
Altitude
de référence
UtilisateurFavorits AFavorits B
ROX 9.0
91
3 TOUT SUR LE SIGMA ROX 9.0
3.6 FONCTIONS ET PROPRIÉTÉS DU SIGMA ROX 9.0
Le SIGMA ROX 9.0 est un appareil très
complet permettant de planifier, suivre
3.6.1 ETENDUE DES FONCTIONS
Le SIGMA ROX 9.0 est équipé de très
nombreuses f
onctions.
Outre les fonctions cycle classiques, le
SIGMA ROX 9.0 dispose également de
fonctions fréquence cardiaque, altitude et
pente vous garantissant un aperçu des
données les plus importantes du tour.
3.6.2 DETECTEUR DE MOUVEMENT
Le SIGMA ROX 9.0 est équipé d’un détecteur
de mouvement.
Le détecteur de mouvement
remplit 2 tâches différentes :
3Démarrage/Arrêt automatique
3Mesure de l’altitude
Grâce au détecteur de mouvement, le SIGMA
ROX 9.0 quitte le mode veille au moindre
mouvement du vélo (à condition que le SIGMA
ROX 9.0 soit déjà monté sur son support). Il
n’est donc pas nécessaire d’appuyer sur une
touche pour l’activer.
Le détecteur de mouvement corrige l’altitude
et le SIGMA ROX 9.0 enregistre l‘altitude
actuelle avant de passer en mode veille.
Lors de l’activation suivante, la dernière
altitude enregistrée est reprise,
et évaluer de manière idéale un tour/un
entraînement.
Le SIGMA ROX 9.0 permet non seulement
d’évaluer les données du tour, mais dispose
également de propriétés simplifiant son
utilisation. (favorits, niveau de navigation, etc.)
peu importe les éventuelles modifications de
la pression atmosphérique. En cas de déplacement survenu alors que le SIGMA ROX 9.0
n’était pas monté, le capteur enregistre les
mouvements du SIGMA ROX 9.0 et mesure
régulièrement la pression atmosphérique.
L’altitude du SIGMA ROX 9.0 est ainsi actualisée pendant le déplacement vers le lieu
suivant. Cela signifie qu’un calibrage n’est
plus absolument obligatoire sur le lieu de
destination.
Note : Il est à noter que, en cas de déplacement en voiture, la mesure de la pression
atmosphérique peut être faussée par la
climatisation et des mesures imprécises
peuvent en résulter.
92
www.sigmasport.com
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.