Sigmasec PTZ-205AHD User Manual

AHD PTZ CAMERA
USER MANUAL
V1.0
Page2
1.1 Features…………………………………………………….……………. 5
1.2 Function ………………………………………………………..…….. 9
1.3 Technical Data …………………………………………………………..9
Common Operation………….…………………….10
After- Sales Service ………….…………………………………...31
Lightning and Surge Protection………………..33
Directory
OSD Menu ……………………………………………...11
Page3
Precaution
Environmental Temperature:
-35
60
º
Environmental Humidity:
<95
Barometric Pressure:
86~106KPa
Power Supply: DC12V/4A
Please read this manual carefully before the installations and operations.
Transportation Security
No heavy stress, violent vibration or water splash are allowed during transportation, storage. The unit should be transported in separated packing. In shipments of distributor and delivery of maintenance, any damages caused by integral packing are not covered by warran­ty.
Installation
This product has two kinds of installation- wall mounting and celling mounting, camera should be handled with care. Do not extrude structure parts. Avoid heavy stress and violent vibration during installation. Camera transparent shield belongs to advanced optical product; don’t touch the dome cover directly by hand. When connecting the power source, please fol­low all electric safety standards and only use the power supply designated for this device. Keep the video and control signal in a decent distance from high voltage devices and cable. If necessary, please take measures for lighting protection and anti-surge protection. Don’t apply power to dome before finishing the installation.
Please do not remove the camera internal components by yourself; there are no repaira-
ble internal components inside the camera for user. For the maintenance work, must be au-
thorized by my company maintenance personnel.
Electronic Safety
If installation site is near television, radio transmitters, near electromagnetic devices, motors, transformers, speakers, they generate electromagnetic fields will interfere with the video and control signals.
Camera Protection
Avoid shooting very bright objects directly into the camera’s CCD (such as the sun or light fittings) and avoid fixating the camera lens on bright static object for long time, as it will cause Irreparable damage to the camera’s CCD
Cleaning Method
Please don’t use abrasive and violent detergent to clean the dome. Please choose dry fabric and neutral detergent. And please use lens paper to clean the lens.
Please use our production under the following environmental standard.
Page4
Product Overview
1.1 Features
1.1.1 Functions
minimum manual speed 0.01º/S maximum sequence speed 360º/S precise positioning
(middle speed camera is not included)
3D positioning functionrealize the PTZ positioning and local magnification on the
screen by software
Built-in digital temperature sensor & semiconductor heater
PWM cooling fan vary-speed temperature control
Auto Compatible PELCO_P, PELCO_D protocol
256preset positionssupport auto-sequence function8 sequence tracks, each sequence
track has 32 presets
8 auto scan with use-defined left and right boundaries and settable scan speed
4 pattern tours,10 Mins memory, 500 programmable instructions
8 private mask area are arbitrary to set (camera module supports private mask function)
Built-in 4 alarm inputs2 alarm outputs (optional, some models without this function)
Alarm triggering: The alarm can trigger preset, auto scan, cruising and pattern tours func-
tions
Guard Location: the dome will rotate back to preset positionauto scanauto sequence
and pattern function after a period of vacant time
1.1.2 Main Features
Delicate stepping motor, stable, sensitive and accurate
Integration design, compact structure
Ingenious mechanical driving devicesupport 360° Pan continuous rotating, without fade zone
90° Tilt rotating, support auto-slip function;
Stepless speed change, auto zoom/speed matching;
Manual Speed0.01º180º/smaximum sequence speed 360º/s
1.1.3 Built-in High Definition Day/Night Camera
• Auto back light compensation
• Auto/manual white balance
• Auto/manual focus
• Auto/manual brightness control
Product Overview 1.1 Features
Page5
In this section, the text describes the main function of infrared intelligent speed dome camera and the general principle of implementation, not involving the specific operation method. For different system platform specific operation method is not the same, generally the system manufacturer's operation manual shall prevail, in some cases there are some special require­ments and operation method, please contact the dealer to get the necessary information.
Focus / PTZ Speed Auto Match
The pan/tilt rotation speed could be automatically adjusted according to the focus in/out which makes it much more practical for manual target tracking
Auto Flip
When the camera tilts downward and goes just beyond the vertical position, the camera
will rotate 180 degrees.
Preset Position Set up and Call Up
In the Preset function the dome stores the current pan/tilt angle, zoom and other position
parameters in its memory. When necessary the dome recalls these parameters and adjusts the camera to a particular position. The user can store, recall and clear the presets easily and promptly by using the keyboard controller. The dome can store up to 256 presets.
Auto Scan
Users can set up the left and right boundaries by control keyboard. Then speed dome can scan between the boundaries. It supports up to 8 groups of scanning paths.
Cruising Track
The preset position can be programmed to be recalled in a set of sequences. This sequence
can be set to let the camera scan from one position to the next in a cycle at a set speed. This feature is called the “auto cruise”. The cruise sequence and dwell time of each preset can be set. It supports up to 8cruising tracks, each cruising track with 32 presets.
Pattern Tour
Dome can memorize 600S running path or 500 programmable instructions. When start
pattern tour, speed dome will move automatically according recorded action path. It supports 4 groups of pattern tours.
Guard Location
User could pre-set camera idle time and action mode (call preset/auto scan/auto se­quence/pattern optional), the dome automatically returns to pre-set position if there is no oper­ation in period of vacant time.
Product Overview 1.2 Functions
Page6
Dome Address Setup
The dome supports up to 256 addresses and the dome will only response to the instructions
given to its own address. Please check the dip switch on the bottom of the dome for address setup.
Privacy Mask Protection
Set black mask areas to protect the privacy zones. The black privacy locations can be set,
and support up to 4 mask zones.
PTZ direction Display Function
User could set due north direction, could realize speed dome camera rotating direction
display precisely, and support area indication, when camera turn to designated area, screen will display setting area title.
● PTZ and Lens Control
Zoom Control
Users can control zoom by keyboard to get near or far images.
Focus Control
The default setting is auto focus. The camera will auto focus based on the center of the
video display to get the clear image. In some special occasions, the user could do the manual focus to get the desired image effect. Auto Back Light Compensation
In the highly bright background, auto back light compensation is aiming to compensate
the brightness of the dark object and adjust the background brightness to get a clear image. Auto/Manual White Balance
Auto/Manual WB adjust depending on the environment light changes.
Day and Night Switch (Only for Day/Nigh Camera)
Speed dome camera can auto switch according to the environmental illumination chang-
es. OSD Setup (Only for camera with menu)
Call upon preset No.95 to enter into OSD menu setup interface.
Alarm function (optional)
The camera support 7 alarm input, 2 alarm output. Alarm input method could be set on or off,
when camera receive alarm signal, according to requirement, user could set alarm trigger switch out. Enable alarm function, camera could trigger switch and trigger preset, auto scan, auto sequence, pattern, auto-tracking function, etc.
DIP Switch Setting
Before the dome is installed, please finish the setup of the communication Protocol, baud rate and dome address. Set the DIP switch inside the dome body, please un­screw the protection cap out, there is two DIP switch.
Product Overview 1.2 Functions
Page7
Method One
Cable Definition
BNC Connector: Video Coaxial Cable
Power Connector: DC12V Red: RS485A
Yellow: RS485B
Method Two
Protocol Setup
Our IR speed dome supports two protocols including Pelco P, Pelco D.
All of them supports baud rate of 9600bps4800bps2400bps.
Set the No.1~4 dip switch for the protocol configuration.
● Baud Rate Setup
Set the No.5~6 dip switch for the baud rate configuration.
Dome Address Encoding sheet
SW1 DIP Switch is used to set dome address. Address setting adopts binary way, the 8th dip is MSD, and the 1st dip is LSD.
SW1— Dip switch for the dome address SW2— Dip switch for the dome protocol
Product Overview 1.2 Functions
Page8
ADD SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8
1 1 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 3 1 1 0 0 0 0 0 0 4 0 0 1 0 0 0 0 0 5 1 0 1 0 0 0 0 0 6 0 1 1 0 0 0 0 0 7 1 1 1 0 0 0 0 0 8 0 0 0 1 0 0 0 0
9 1 0 0 1 0 0 0 0 10 0 1 0 1 0 0 0 0 11 1 1 0 1 0 0 0 0 12 0 0 1 1 0 0 0 0 13 1 0 1 1 0 0 0 0 14 0 1 1 1 0 0 0 0 15 1 1 1 1 0 0 0 0 16 0 0 0 0 1 0 0 0 17 1 0 0 0 1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1 0 0 0 23 1 1 1 0 1 0 0 0 24 0 0 0 1 1 0 0 0 25 1 0 0 1 1 0 0 0 26 0 1 0 1 1 0 0 0 27 1 1 0 1 1 0 0 0
Protocol SW2-1 SW2-2 SW2-3 SW2-4
PELCO P ON OFF OFF OFF
PELCO D OFF ON OFF OFF
Reserved
Protocol SW2-1 SW2-2 SW2-3 SW2-4
PELCO P ON OFF OFF OFF
PELCO D OFF ON OFF OFF
Reserved
Product Overview 1.2 Functions
Page9
Red 485A[+] Yellow 485B[-] yellow & green ground wire
power socket
BNC connector
There is no further notice when the specification parameters are changed.
28 0 0 1 1 1 0 0 0 29 1 0 1 1 1 0 0 0
30 0 1 1 1 1 0 0 0 31 1 1 1 1 1 0 0 0 32 0 0 0 0 0 1 0 0
253 1 0 1 1 1 1 1 1 254 0 1 1 1 1 1 1 1
Product Overview 1.2 Functions
1.3 Technical Data
Page10
Common Operation
2.1 Common Operation
Main Functions Fast Call Up
Our dome supports 256 preset positions. You can activate some special functions by call­ing upon code number 65-99.
OSD Menu Operations:
1, Call Preset 95 to enter the main OSD menu (or call preset No.1 two times continu­ously within two seconds)
2, Control the joystick to move the cursor around the menu
3, Press “Iris Open” to enter the menu for selections
4, Move the joystick up and down to select the item
5,Press “Iris Open” to confirm the selection
6, Press “Iris Close” to cancel the selection
Common Operation
Page11
OSD Menu
The user can check the dome information as required. The system information includes: version, dome address, baud rate, temperature, voltage. Use the following steps to display the System Information screens:
1. Click up/down to choose
2. Press IRIS OPEN. The INFORMATION screen opens.
MAIN
( INFORMATION )
DOME SETTINGS
MOTION RESTART
FACTORY
EXIT
(VERSION:VR210P-200 ) ADDRESS:001 BAUDRATE:2400 TEMPERATURE:30 VOLTAGE:12.1V
BACK EXIT
INFORMATION
3.1 INFORMATION
OSD Menu
Loading...
+ 23 hidden pages