1. SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved.
2. Information in this publication replaces all previous
corresponding material.
3. SIGLENT reserves the right to change the specifications and
price of the product.
4. Any way of copying, extracting and translating the contents of
the manual are not allowed without permission of SIGLENT.
Note: SIGLENT is the registered trademark of SIGLENT.
SPD3303C Quick Start I
SIGLENT
General Safety Summary
Please review the following safety precautions carefully to avoid
personal injury or damage to this product or any product connected
to it. To prevent potential danger, please use the instrument as
specified.
Use proper power cord
Only the power cord designed for the instrument and authorized by
local country could be used.
Power supply
AC Input Voltages: 100V/110V/220V/230V ±10%, 50/60Hz.
Use proper fuse
The fuse types: 100V/110V(T6.3A/250V); 220V/230V
(T3.15A/250V);
Make sure to use the correct type of fuse before turning on the
instrument.
Do not connect the power cord before replacing the fuse.
Find out the reason why the fuse burned out before replacing the
fuse.
Ground the instrument
The instrument is grounded through the protective terra conductor
of the power cord. To avoid electric shock, the grounding conductor
must be connected to the earth. Make sure that the instrument is
properly grounded before any inputs or outputs.
Observe all terminal ratings
To avoid fire or electric shock, please observe all ratings and
symbols on the instrument. Read this guide carefully to know more
details about the ratings before connection.
II SPD3303C Quick Start
SIGLENT
Keep proper ventilation
Inadequate ventilation may cause an increase of temperature,
which will lead to further damage. Please keep proper ventilation
and check the fan and air-vents regularly when using the
instrument.
Operate condition
Location: indoor, no strong light, almost no Interfering pollution;
Comparative humidity: <80%
Altitude: <2000m
Temperature: 0 to 40℃℃
Do not operate in an explosive atmosphere
To avoid personal injury or damage to instrument, please do not
operate in an explosive atmosphere.
Keep surface of the product clean and dry
To avoid dust or moisture in the air influence the performance of the
instrument, please keep surface of the product clean and dry.
SPD3303C Quick Start III
SIGLENT
Safety Terms and Symbols
Terms may appear on the product:
DANGER: Indicates direct injury or hazard that may happen.
WARNING: Indicates potential injury or hazard that may happen.
CAUTION: Indicates potential damage to the instrument or other
property that may happen.
Symbols may appear on the product:
Hazardous Protective Warning Earth Power
Voltage Earth Ground Ground Switch
IV SPD3303C Quick Start
SIGLENT
Brief Introduction
SPD3303C LED series Programmable DC Power Supply is
convenient, flexible and multi-function. It is designed with three
groups of independent output terminals, the output voltage of two
groups is adjustable and another group is fixed to select: 2.5V, 3.3V,
and 5V. The instrument also provides output short circuit and
overload protection.
Main Features
Three independent output channels, two of which are
controllable, with a total power up to 195W;
Compatible design for power voltage: 100V, 110V, 220V and
230V to satisfy different power network;
Capable of saving and recalling set parameters;
Perfect PC software to realize the real-time control through