The are digital panel meters for connection of measurement for voltage (10 V) and current
(1 mA, 20 mA or 4 ... 20 mA) with 4 ranges.
Operation:
The setting of measuring range and display range is made by positioning DIP switches. The chosen input range is
user adjustable from 10% to 100 % of the full scale value by potentiometer on the rear of the meter.
Further BETA 90A versions from the series:
BETA 90A F
Technical data
Display Display range
Decimal point position
Negative display indication “-”
Digit height 8 mm / 7-segment digits
Overload indication last 3 digits blank
Measuring range Direct voltage 0 ... 10 V
(input current < 100 uA)
Direct current 0 ... 1 mA; 0 ... 20 mA; 4 ... 20 mA
(Voltage drop < 200 mV)
Range adjustment 1 : 10
Accuracy < 0.2 % of range + 1 digit
Temperature coefficient 100 ppm / °C, plus
Zero point drift 200 ppm / °C
Supply of power Direct voltage DC
Environmental conditions Climatic class Class 2 to VDE / DIN 3540
Operating temperature 0 ... 50 °C
Storage temperature -40 °C ... +80 °C
Safety class II to IEC 348/VDE 0411
Protections class IP 20 to IEC EN 60 529
Front IP 54 (IP 65 on request)
Device safety correspond IEC EN 61 010
EMC immunity correspond DIN EN 61 000-4-1 to 4
EMC radiated interference correspond DIN EN 50 081 class B
Dimensions and weights Bezel size 48 mm x 24 mm to DIN 43 718
Panel cut-out 45 +0.6 mm x 22.2 +0.3 mm
Overall depth 69 mm
Weight 45 g approx
Sundry Connections Plug-in screw
BETA 90A
Voltage measurement, 4 ranges.
1999
selectable
48 V DC ( 10 % ) 1.2 W, isolated
21 ... 30 V DC 1.2 W, isolated
12 V DC ( 10 % ) 1.2 W, isolated
±
±
Operating Manual
BETA 90A