Sierra Monitor Corporation 2050, 2060 User Manual

Ammonia and Halocarbon Gas Monitors
Cost effective gas alarm monitors for ammonia and halocarbon gases. Avail­able as single channel monitors or part of multipoint alarm system
The Model 2050 Ammonia and Model 2060 Refrigerant/ Halocarbon Gas Monitors are continuous duty, low cost stationary monitors for detection of high levels (50-500 PPM) of ammonia and halocarbon refrigerant gases. These moni­tors are primarily used in and around freezers, refrigera­tors, and compressor rooms to warn of leaks and danger­ous levels of these gases.
An alarm is activated when the concentration of gas ex­ceeds the user-adjustable level. An alarm condition acti­vates the alarm light on the front of the monitor and gener­ates an output signal. An output signal can activate a remote alarm through the Model 2102 Alarm Panel. The Model 2102 Dual Channel can be connected up to 500 feet from the monitors. Each monitor also has a 0.5 amp, dry contact relay replaces the output signal.
The monitors are housed in a polystyrene enclosure that is suitable for installation in freezer, refrigerator or other applications. Test connections and adjustment controls are located on the outside of the enclosure and are easily used, even when the operator is wearing hand protection.
Alarms
These monitors have two indicator lights on the front of the unit, a green “safe” indicator and a red “alarm” indicator. Three alarm conditions are possible. These can be de­tected visually at both the monitor and controller at all times.
Model 2050/2060
Sensor failure - Interrupted (on/off) “red/green” vi-
sual indication after unit has been in operation, indi­cating either a failed sensor or that the monitor is not correctly calibrated.
The Model 2050 Ammonia monitor has a factory alarm setpoint of 100 ppm NH3. This setpoint is user adjustable in the field over a range of 50 to 500 ppm NH3. The Model 2050 calibration can be checked with Hydrogen gas.
The Model 2060 Halocarbon monitor can be calibrated with methane and the factory setpoint varies for the specific type of halocarbon present. The factory setpoint for R12 is 500 ppm while the setpoint for R134a is 50 ppm. See the specifications for more details.
Temperature Range
The Model 2050 and 2060 have temperature compensated circuitry to provide stabilization in temperatures ranging from -4o to 158oF.
Semiconductor-T ype Sensor
Warm-up - Interrupted (On/Off) “red/green” visual in-
dication when power is first connected to the monitor, followed by a red light until warm-up is completed and the green light comes on.
Gas Alarm - Sustained solid red light indicating the
presence of gas at, or above, the pre-set threshold.
Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 (408) 262-661 1 (800) 727-4377 FAX: (408) 262-9042
A solid-state semiconductor-type sensor and associated electronic circuitry ensure trouble-free, long-term opera­tion. There are no pumps, filters, or chemical cells to replace or maintain. Except periodic calibration to verify the alarm setting, no periodic maintenance is required af­ter installation. The user may adjust the alarm level by using a different calibration gas concentration.
Ammonia and Halocarbon Gas Monitors
SPECIFICATIONS
Indicators: Green LED for Monitor “ON”/Safe
Red LED for Alarm Sensor Type: Solid-state metal oxide semiconductor Alarm Setpoint::
2050 Series 100 ppm NH 2060 Series R1 1 500 ppm
R12 500 ppm
R22 50 ppm
R1 13 100 ppm
R123 70 ppm
R134a 50 ppm
R141b 40 ppm
R142b 40 ppm
R500 40 ppm
R502 70 ppm
User adjustable with calibration over
range of 50 to 500 ppm
ORDERING INFORMA TION 2050-00 Ammonia Gas Monitor
2060-00 Refrigerant/Halocarbon Gas Monitor 1200-26 Gas Sensor Calibrator w/2 gas cylinders
of calibration gas
1290-10 Gas Cylinder - Carbon Monoxide, 150 ppm 1290-11 Gas Cylinder - Hydrogen, 80 ppm
3
Model 2050/2060
Calibration Gas: 2050 Series 80 ppm Hydrogen (H 2060 Series 150 ppm Carbon Monoxide (CO)
Power: 9-24 VDC, 250 mA Signal Output::
2050-00/2060-00 Nominal 5 volt DC, source 25 mA. SAFE
and ALARM Signals
0.5 AMP dry cont act, 100 VDC, 130 V AC and audible
Response T ime: Less than 90 seconds Operating T emperature Range:
Enclosure Material: Polystyrene Size: 5.6 x 3.1 x 2.1 in. (14.2 x 7.9 x 5.3
Weight: 0.3 lb (0.15 Kg)
o
to 158oF (-20o to 70oC)
-4
)
2
cm)
OTHER PRODUCTS 2102-00 Dual Channel Alarm Panel
Outline and Dimensions
of Model 2050/2060
Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 (408) 262-661 1 (800) 727-4377 FAX: (408) 262-9042
Visit our website: www .sierramonitor .com E-mail: sierra@sierramonitor .com
© 2005 Sierra Monitor Corp. Rev. A-9/15/05