The Sentry Gas Risk Management System has a variety of calibration and sensor options to insure accurate and reliable monitoring of hazardous gases.
A variety of accessories insure that Sentry systems are pro­viding accurate and reliable monitoring of hazardous gas conditions. These options aid in providing a system designed to meet the specific needs of the user.
CALIBRATORS
1250-00 Calibration Gas Delivery System (High Capacity)
The 1250-00 Calibrator Kit is used to deliver calibration gas for combustible gases and a wide variety of toxic gases in­cluding Hydrogen Sulfide, Chlorine, Sulfur Dioxide, Nitric Ox­ide, Nitrogen Dioxide and others. The 1250 Calibrator Kit consists of a regulator, calibration adapter, carrying case and tubing. The calibration gas cylinders (Series 1260) are sold separately. The 1260 series gas cylinders are large capac­ity enabling the user to perform many calibrations with a single cylinder.
GAS MONITORING SYSTEM
ACCESSORIES
1200-26
1200-26 Calibration Gas Delivery System (Low Capacity)
The Model 1200-26 Calibration Gas Delivery System pro­vides calibration gas for Combustible Gas, Carbon Monox­ide, or Hydrogen. This system consists of a disposable pres­sure vessel (2 cylinders supplied with each system) con­taining calibration gas and a non-disposable pressure and flow regulation system. Gas flow is controlled in two steps with a regulator and flow meter to conserve gas and to avoid cooling the sensor below its operating temperature.
The 1200-26 and the Methane calibration gas cylinders are approved for calibration of Factory Mutual Research Corpo­ration (FMRC) approved 5100-02 Sierra Monitor Combus­tible Gas Sensors.
9210-00 Permeation Type Calibrator (Toxic)
The 9210-00 Permeation Type Calibrator with the individual permeation tube for the specific gas required offers a unique means of generating a desired gas in small quantities. This device has the advantages of a wide selection of gas types, long life, and is an economical solution for the regular cali-
1250-01
1991 Tarob Court, Milpitas, CA USA 95035 Phone: 408-262-6611 Fax: 408-262-9042 (800) 727-4377 Email: sierra@sierramonitor.com www.sierramonitor.com
bration of a large number of toxic sensors.
ACCESSORIES
SAMPLE DRAW PRODUCTS
Sample draw products are used in applications in which the sensor cannot be installed directly at the gas sensing location due to poor accessibility or the harshness of the environment. Sample is continuously drawn from the sens­ing location to the sensor at a more suitable location.
The primary component of the sample draw product is a venturi manifold that uses a continuous flow of driver air to pull a slight vacuum through the sample supply line draw­ing the sample into the manifold cavity connected to the sensor.
5399-01 Sample Draw Fitting
The sample manifold assembly is the 5399-01 Sample Draw Fitting. Sample stream draw and flow control is pro­vided by the user.
5398-01 Sample Draw Assembly
The 5398-01 is a complete sample draw assembly includ­ing the sample draw fitting, driver air, sample and exhaust fittings and flow metering assembly. This allows accurate adjustment of sample flow using the signal flow meter lo­cated on the flow metering assembly.
ACCESSORIES
SENSOR MOUNTING PRODUCTS
5311-00 Rainshield
The Rainshield is mounted over the sensor head to pro­tect the sensor from direct exposure to rain, hosedown and other splashing liquids.
5394-00 Duct Mount Fitting
The Duct Mount Fitting facilitates installation of the gas sensor module onto an air duct. The fitting also includes the 5360-00 calibration gas delivery fitting so that calibra­tion gas can be delivered to the sensor with out removing the module from the duct.
5360-00
5394-00
ACCESSORIES
5398-01
5398-02 Sample Draw/Dilution Assembly
The 5398-02 is used in applications in which the expected gas concentration is either higher than the maximum range of the sensor or sufficiently high to significantly reduce sen­sor life with extended exposure. This assembly adds a second flow meter for control of dilution air. Adjustment of sample and dilution air flow meters determines the dilu­tion ratio. Concentrations displayed on the Sentry Con­troller must then be multiplied by the dilution factor to ar­rive at actual concentrations.
CALIBRATION ADAPTERS
The Sentry system is designed for easy calibration of the sensor modules. The standard calibration adapter screws over the head of the sensor. Then calibration gas is fed through a tube connected onto the adapter.
Magnetic calibration adapters are commonly used with Sentry gas sensor modules. The magnetic calibration adapter is used to control a switch inside the sensor mod­ule. When the adapter is first applied to the sensor the switch closes to indicate the start of calibration and the zero gas stage. The second time the adapter is applied to the module, the switch closure indicates that span gas is being applied. When the magnetic adapter is removed, the module knows that calibration is complete and sends the appropriate signal to the controller.