Sierra Flame STANFORD55GLPDELUXE User Manual

Page 1
CLIENT # LC773211
STANFORD 55L DIRE CT VENT LINEAR
WARNING
IF THE INFORMATION IN THESE INS T RUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROP ERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS:
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
INSTALLER: Leave this manual with the appl iance. CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
REFERENCE.
36,000 BTU
Installation and Operating Instructions
MODEL: STANFORD-55G-NG-DELUXE
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbour’s phone. Follow gas supplier’s
instructions
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
Page 1 of 58
Page 2
CLIENT # LC773211
STANFORD 55L DESIGNER ELITE VISAGE CLEAN
AVERTISSEMENT
ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquids inflammables dans le
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
L'installation et l'entretien doivent être assurés par un installateur ou un service d'entretien
AVERTISSEMENT: Une mauvaise installation, de réglage, la modification, de services ou de
S'IL VOUS PLAIT LIRE CE MANUEL
INSTALLATEUR : Laissez cette notice avec
pour consultation ultérieure.
Une surface vitrée chaude
Laisser refroidir la surface
36,000 BTU
Manuel D’installation et Guide de l’utilisateur
MODEL: STANFORD-55G-NG-DELUXE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER
voisinage de cet appareil ou de tout autre appareil.
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le
bâtiment où vous vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
GAZ NATUREL ET PROPANE
qualifié ou par le fournisseur de gaz.
maintenance peut causer des dommages corporels ou matériels. Reportez-vous à ce manuel. Pour toute assistance ou information supplémentaire, consulte r un i nstallateur qualifié, un service ou le fournisseur de gaz.
AVANT D'INSTALLER OU UTILISER
CET APPAREIL. CONSERVEZ CE
MANUEL POUR REFERENCE FUTURE.
l’appareil. CONSOMMATEUR : Conservez cette notice
peut causer des brûlures.
vitrée avant d’y toucher
Ne permettez jamais à un
enfant de toucher la
surface vitrée.
Page 2 of 58
Page 3
Table of Contents
WARNING
IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 5
1.0 INTRODUCTION .....................................................................................................................
1.1 Specifications, Appli a nce Dimensions & Installation Codes ................................. 6 - 7
1.2 Features, Remote Control Functions .................................................................. 8 - 10
1.3 Intended Use ............................................................................................................ 11
1.4 General Safety .................................................................................................. 11 - 12
2.0 OPERATION ...........................................................................................................................
2.1 Lighting Instructions ......................................................................................... 13 – 14
3.0 INSTALLATION ......................................................................................................................
3.1 Installation & Safety Notes ...................................................................................... 15
3.2 Unpacking ................................................................................................................ 15
3.3 Installation ............................................................................................................... 15
3.3.1 Minimum Clearances & Non Combustible Material Requirements .................. 16 - 18
3.3.2 Gas Line Installation ................................................................................................ 19
3.3.3 Direct Vent Information .................................................................................... 20 - 31
3.3.4 Glass Media Installation ........................................................................................... 32
3.3.5 Door Installation ................................................................................................ 33 - 34
3.3.6 Initial Firing .............................................................................................................. 34
3.3.7 Pilot Flame Adjustment ............................................................................................. 35
3.3.8 Primary Air Adjustment ............................................................................................ 35
3.3.9 Altitude Adjustment .................................................................................................. 36
3.3.10 Fan Access ....................................................................................................... 36 - 38
3.3.11 Gas Valve Access .................................................................................................... 38
4.0 MAINTENANCE .....................................................................................................................
4.1 Maintenance Safety ................................................................................................. 39
4.2 Recommended Service ........................................................................................... 39
4.3 Glass Cleaning ........................................................................................................ 40
4.4 Burner & Pilot Cleaning ........................................................................................... 40
4.5 Valve & Pilot Replacement ............................................................................. 40 - 41
5.0 TROUBLE SHOOTING ……………………………………………………………….……. 42 - 45
6.0 REPLACEMENT PARTS ………………………………………………………………………...46
7.0 WARRANTY .………………………………………………………………………………....47 - 49
8.0 LABEL INFORMATION .………………………………………………………………….…50 - 51
APPENDIX A (INTERMITTENT PILOT & VALVE KIT)……………………....………………….52 - 55
APPENDIX B (NG – LP CONVERSIO N KITS)........................................................................55 - 57
Page 3 of 58
Page 4
Read this owner’s manual carefully and completely before trying to assemble, operate
or service this fireplace. Follow instructions for proper installation
burns, explosions, electrical shock and carbon monoxide poisoning.
AVERTISSEMENT
• Lisez ce manuel attentivement et complètement avant d'essayer de monter, utiliser ou
monoxyde de carbone.
E
D
VAPORS AND LIQUIDS.
Failure to install this appliance per the manufacturer’s instructions or fail ure to use only
parts specifically approved with this appliance may result in property damage or personal injury. Any change to this fireplace or its controls can be dangerous.
Improper installation or use of this fireplace can cause serious injury or death from fire,
entretenir ce foyer. Suivre les instructions pour assurer une bonne installation.
• Risque de dommages ou de blessures si l’appareil n’est pas installé selon les instructions du fabricant ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées. Tout changement à ce foyer ou à ses contrôles peuvent être dangereux.
• Une mauvaise installation ou l'utilisatio n de cette cheminée peut causer des blessures graves ou la mort par le feu, les brûlures, explosions, de chocs électriques et intoxication au
UE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAF F IC AND AWAY F R OM
FURNITURE AND DRAPERIES
.
C
HILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION
. YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE
N RAISON DE TEMPERATURES ELEVEES, L'APPAREIL DOIT ETRE PLACE HORS DE LA CIRCULATION ET LOIN
DES MEUBLES ET TENTURES
.
ENFANTS ET ADULTES DOIVENT ETRE AVERTIS DES DANGERS DE LA TEMPERATURE DE SURFACE ELEVEE ET
'ECART POUR EVITER LES BRULURES OU L'INFLAMMATION DES VETEMENTS.
DEVRAIT RESTER A L
LES JEUNES ENFANTS DOIVENT ETRE SOIGNEUSEMENT SURVEILLES QUAND ILS SONT DANS LA MEME PIECE
'APPAREIL.
QUE L
CLOTHING OR OTHER MATERIAUX COMBUSTIBLES NE DOIVENT PAS ETRE PLACES SUR OU PRES DE
'APPAREIL.
L
GARDER LA ZONE SALLE CLAIRE ET LIBRE DE MATERIAUX COMBUSTIBLES, D'ESSENCE, ET AUTRES
VAPEURS ET LIQUIDES
Page 4 of 58
Page 5
WARNING
AVERTISSEMENT
Do not use this appliance if any part has
been under water. Immediately call a
has been under water.
Ne pas utiliser cet appareil s’il a été plongé,
plongée dans l’eau.
Toddlers, young children and others may be
Les tout-petits, les jeunes enfants et d'autres
les jeunes enfants et les personnes à risque de
propres.
This fireplace is a vented product. This
Ce foyer est un produit ventilé. Ce foyer doit
Caution: Label all wires prior to
Attention : Au moment de l’entretien des
inadéquate et dangereu x.
Verify proper operation after servicing
S’assurer que l’appareil fonctionne
If appliance is installed directly on carpeting,
the full width and depth of the fireplace.
Si l'appareil est installé directement sur un
métal ou de bois se prolongeant sur toute la
qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which
meme partiellement, dans l’eau. Appeler un technician qualifié pour inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été
susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers, young children and at risk individuals out of the room and away from hot surfaces. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
peuvent être sensibles aux brûlures par contact accidentel. Une barrière physique est recommandé s'il ya des personnes à risque dans la maison. Pour restreindre l'accès à une cheminée ou un poêle installer une barrière de sécurité réglable pour garder les tout-petits,
la salle et à l'écart des surfaces chaudes. Tout écran ou grille de protection pour l'entretien d'un appareil doit être remplacé avant de faire fonctionner l'appareil. Installation et réparation doit être effectuée par un technicien qualifié. L'appareil doit être inspecté avant son utilisation et au moins annuellement par un technicien qualifié. Un nettoyage plus fréquent peut être nécessaire en raison de peluches provenant des tapis, literie, etc. Il est impératif que les compartiments de contrôle, les brûleurs et les conduits d'air de l'appareil soient gardés
fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with the glass door properly seated and sealed gas leakage can occur.
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
vinyl tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending
être correctement installé par un technicien qualifié. La porte en verre doivent être placés correctement et scellé. Si cet appareil n'est pas correctement installé par un technicien qualifié avec la porte en verre bien en place et des fuites de gaz scellés peuvent se produire.
commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de câblage peuvent entraîner un fonctionnement
adéquatement une fois l’entretien terminé
tapis, carreaux de vinyle ou autre matériau combustible autre qu'un plancher de bois, l'appareil doit être installé sur un panneau de
Page 5 of 58
Page 6
1.0 INTRODUCTI ON
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
largeur et la profondeur de la cheminée.
1.1 SPECIFICATIONS

TABLE 1

ITEM NAT URAL GAS (NG) PROPANE (LP)
MAXIMUM INPUT: Hi 36,000 Btu/hr (10.55 kW) 32,000 Btu/hr (9.38 kW)
MINIMUM INPUT: Lo 21,250 Btu/hr (6.23 kW) 26,000 Btu/hr (7.62 kW)
MANIFOLD PRESSURE:
COLLECTEUR DE PRESSION:
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
ORIFICE SIZE: @ 0-2000’
FORMAT D'ORIFICE:
AIR SHUTTER
VOLET DE L’AIR
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
VENTING
ÉVACUATION
FAN
VENTILATEUR
3.5” w.c. (0.87 kPa) 10.0” w.c. (2.49 kPa)
Minimum: 5.0” w.c. (1.2 kPa) Minimum: 7.0” w.c. (1.74 kPa)
Maximum: 13.5” w.c. (3.4 kPa) Maximum: 13.5” w.c. (3.4 kPa)
2 X # 45 DMS 2 X # 56 DMS
OPEN 3/8”min
(9.525mm)
Skytech AF-40004 Skytech AF-40004
2-ply aluminum vent, Selkirk,
Duravent , Security Venting,
ICC Venting or
Metal-Fab Venting
Variable Speed (110 Volt / 60 Hz) Variable Speed (110 Volt / 60 Hz)
2-ply aluminum vent, Selkirk
FULLY OPEN
Duravent, Security Venting,
ICC Venting or
Metal-Fab Venting
Page 6 of 58
Page 7

APPLIANCE DIMENSIONS Figure 1

INSTALLATION CODES

This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe. Installation must conform to local codes. In the absence of local codes, installation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1. The unit, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electric Code ANSI/NFPA No.70 or with the current Canadian Electrical Code CSA C22 .1. In the state of Massachusetts, this product can only be installed by a licensed plumber or a licensed gas fitter. Failure to comply will void the warranty. This appliance has been certified for use with natural gas and propane. This appliance is not for use wi th soli d fuel s.

CODES D'INSTALLATION Cet appareil est un appareil à évent direct, qui attire tous l'air de combustion provenant de l'extérieur du bâtiment par une entrée d'évent. L'installation doit se conformer aux codes locaux. En l'absence de codes locaux, l'installation doit être conforme au National Fuel Gas Code ANSI Z223.1/NFPA 54, ou le gaz naturel actuel et le Code d'installation du propane CSA B149.1. L'unité, une fois installé, doit être électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, avec le National Electric Code ANSI / NFPA No.70 ou avec l'actuel Code canadien de l'électricité CSA C22.1 Cet appareil a été certifié pour une utilisation avec du gaz naturel et le propane. Cet appareil n'est pas pour une utilisation avec des combustibles solides.

Page 7 of 58
Page 8
1.2 FEATURES
Ignition system: Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Fan control * Optional * Variable speed control: For units equipped with a fan control, the knob controls the fan speed, turning the knob
counter-clockwise turns it to the “Off” position.
Gas control: * Optio nal* Gas control valve type: Automatic millivolt powered combination gas control valve with variable flame control for
convenience and on/off switch. Optional digital remote on/off wall switch and/or optional wall thermostat (note: thermostats are not allowed in the United States). The gas valve does not require electricity from an external source.
Electronic Valve: * Optional * Automatic DC valve with AC power adapter. Hand held remote control.
Fan control: * Optional * Variable speed control: For units equipped with a fan control, adjust speed by remote control settings 1-6
Supreme Remote Control
Functional Operation Matrix
Initial Setup
Installation of (2) A A A-size batteries will activate the set up mode. Setup mode can also be activated by pressing the FLAME REAR and PROG/TIME buttons simultaneously for 5 s econds. The control will exit setup mode if no button is pressed for 20 seconds. Appropriate icon on LCD will flash when ready for setup. Press the UP or Down button in set up mode to change the temperature scal e. Press SET button to skip or advance to Fuel Type setup. Press the UP or DOWN button t o s witc h c ontrol from Natural to LP, or LP to Natural Gas. Press SET button to skip or advance t o Cl oc k setup. Press the UP or Down Button to set the hour. Press SET to advance to minutes. Press the UP or Down button to s et minutes. Press SET to advance to AM or PM. Press the UP or Down button to s et AM or PM. Press the SET button to advance to the day of week. Use UP or Down button to select the day of the week. The control will exit setup mode in 20 seconds.
MODE Button
The MODE button cycles the unit through the basic operational modes . When off, press and release t he MODE button to turn the unit on in Manual mode. Press and release the MODE button again, and the unit will operate in the Thermostat mode. Press and release the MODE button again, and the unit will turn off.
Page 8 of 58
Page 9
Program Mode The Program function is controlled by the PROG/TIME button. The control may be programmed for up to
two settings for weekdays and two settings for weekends. The control is preset to factory settings. When the Program Mode is activated, the unit will automatic ally be op erating in the Thermostat Mode. The unit will turn on or off bas ed upon room and set temperature. To activate the Program mode, press and release the PROG/TI ME but ton. To change the settings for t he Program mode, press and hold the PROG /TIME button for 5 seconds. The program feature will flash at the top of the screen. Press the UP or DOWN button to change the setting of the weekday (MTWTF) P1 ON. Pr es s and releas e the SET button. Press the UP or DOWN button t o c hange the setting of P1 OFF. Press and release the SET button. Press the UP or DOWN button t o c hange the setting of P2 ON. Press and release the SET button. Press the UP or DOWN button t o c hange the setting of P2 OFF. Press and release the SET button. Press the UP or DOWN button t o c hange the setting of the weekend (SS) P1 ON. Press and release the SET button. Press the UP or DOWN button to change the setting of P1 OFF. Press and release the SET but ton. Press the UP or DOWN button t o c hange the setting of P2 ON. Press and release the S E T button. Press the UP or DOWN button t o c hange the setting of P2 OFF. Press and release the S E T button. The Program Mode has been re-programmed.
Countdown Timer
The Countdown Timer Mode all ows the control to operate the unit for up to 3 hours, in 10-minute increments. It can be operated in eit her the Manual or Thermostat Modes. To enter Timer Mode, press and release the TIMER button. The Timer icon will flash. Press the UP or DOWN button t o s et the running time, in 10-minute increments. Press and release the SET button. The timer will run for the set time duration. Pressing the TIMER button while in Timer Mode will terminate the Timer operation. The Timer operation will also terminate if the MODE button is cycled to off.
Thermostat Mode
The unit is placed in Thermostat Mode using the MODE button. Placing the unit in Thermostat Mode will activate the numbers in the smaller window on the LCD screen. Press the UP or DOWN button t o c hange the thermostat set temperature. When the desired set temperature appears, pres s and release the SET button to set. If the SET button is not pressed, the set temperature will automatically be set after 5 seconds. The Thermostat Mode can be de-activated by pressing the MODE button.
Thermostatic Flame Modulation
This control can perform Main Flame Modulation using the Thermostat. The control will shut the unit of f when the room temperature reaches 2° above set temperature. The Thermostat will automatically modulate the main flame:
Manual Flame Modulation – Main Flame
To change the Flame Level manually, press the FLAME MAIN button. The current level will show in the MAIN box on the LCD screen. Press the UP or DOWN button t o c hange the Flame Level. When the unit is turned on, whether in Manual, Thermostatic, or Program Mode, the Main Flame will automatically ignite at the High (7) setting. After 5 seconds, t he flame will default to the previous s etting.
Page 9 of 58
Page 10
Fan Control
The unit must be ON to operate the Fan. The Fan will turn on after 5 minutes of operation. Once the Fan comes on, it can be controlled using the FAN button. Press the FAN button, and the fan icon and speed will appear on the LCD screen. Press the UP or DOWN button t o c ontrol the fan speed (0-6). Press the DOWN butt on until 0 Level is reached to turn the Fan off. The fan will run for 12 minut es after the unit is shut off in any mode. The f an may not be controlled during this period.
Continuous Pilot
The unit can be changed from Intermittent Pilot Ignition (IPI) , to Continuous, or standing, pilot. To place the unit in continuous pilot mode, press and release the PROG/TIME and the FLAME MAIN buttons simultaneously Repeat the simultaneous PROG/TIME and FLAME MAIN push to place the uni t back in IPI mode. This feature can also be activated by the Continuous Pilot (On/Off) switch on the Main Module.
Child Lock-Out
The Child Lock-out feature c an be ac tivated by pressing the PROG/ Time and UP buttons simultaneously. CP will appear on the LCD screen, and no signals can be sent from the t ransmitter.
To take the control out of C hild Lock-out mode, repeat the above step. CP will disapper from the screen.
Learn Function
To program the system to a tr ansmitter, press the LEARN button on the Mai n Mo dule. A single audible beep will be heard. Press the MODE button on the transmitter to learn the transmitter to the system. A series of beeps will be heard. Up to two additional (NO N -THERMOSTATIC) transmitters can be used simultaneously. To learn additional transm i tt er s, press and release the learn button agai n, and press the on button on the additional transmitters. To clear all transmitters and start over, press and hold the LEARN but ton for 10 seconds. A series of three beeps will be heard, and the system is clear.
Low Battery Indicator
A low battery icon will appear on LCD screen when transmitter batteries reach low voltage l evel.
Thermal Safety
When the internal com ponents of the Main Module reach 170°F, the unit will automatically shut off, and send a repetitive audibl e signal. The unit can be turned back on when t he module cools below 160°
Communication Safety
When in the Thermostat or P rogram Mode, the transmitter will send a silent signal to the module every 15 minutes. If a signal is not receiv ed within 2 hours due to dead batteries, lost transmitter, or transmitter out of range, the unit will automatically shut down, and the module will send a repetitive audible signal.
. Continuous Pilot will appear on the LCD screen.
Page 10 of 58
Page 11
1.3 INTENDED USE / US AGE PROPOSÉ
This appliance is intended to be used as a zero clearance fireplace. Cet appareil est destiné à être utilisé comme un foyer à dégagement zéro.
1.4 GENERAL SAFETY / SÉCURITÉ GÉNÉRALE
Maintain adequate clearances around air openings into the combustion chamber.
Respecter les distances minimales convenables autour des bouches d'air dans la chambre de combustion.
Maintain adequate accessibility clearances for servicing and proper operation.
Respecter les distances minimales d'accessibilité suffisante pour l'entretien et bon.
This appliance shall not be connected to chimney flue serving a separate solid-fuel burning appliance.
Cet appareil ne doit pas être raccor dé à une cheminée desservant un autre appareil brûlant des combustibles
solides.
The appliance area m us t be k ept cle ar an d free f rom com bustible m ater ials, gas oline and ot her f lamm able liquids and vapors.
La zone appareil doit rester clair et exempt de matériaux combustibles, essence et autres vapeurs et liquides inflammables.
The flow of combustion and ventilation air shall not be obstructed.
Le débit de combustion et de ventilation ne doit pas être obstrué.
The combustion air suppl y shall be in the same pressure zone as the drafthood r elief opening on an appliance
equipped with a drafthood or as the vent outlet on an appliance not equipped with a drafthood.
L'alimentation en air de co mbustion doit être dans la zone même pres sion que l'ouverture de sec ours hotte à air sur un appareil équipé d'une hotte à air ou que l'évent de sortie sur un appareil n'est pas équipé d'une hotte à air.
Do not use this appliance if an y part has been under water. Immediately call a qualified ser vice technician to inspect the appliance and to r eplace any part of the control system and any gas control which has been under water.
Ne pas se servir de cet appar eil s’i l a été plong é dans l’eau, m êm e partiellem ent. Fair e inspec ter l’app areil p ar un technicien qualifié et r emplacer toute partie du systèm e de c ontrô le et tou te c om mande qui ont été plongées dans l’eau.
Page 11 of 58
Page 12
IMPORTANT
PLEASE READ THE FOLLOWING CAREFULLY
It is normal for fi replaces fabricat ed of steel t o give off some e xpansio n and/or con traction no ises
during the start up or cool down cycle.
It is recommended that you burn your fireplace for at least 4 (four) hours the first time you use it.
IMPORTANT
S'IL VOUS PLAÎT LIRE ATTENTIVEMENT CE QUI SUIT
Il est normal pour les foyers fabriqués d'acier à dégager une certaine expansion et / ou des bruits
fois que vous l'utilisez .
WARNING
Hot while in operation. Do Not Touch. Severe burns may result. Keep children, clothing,
of the appliance be kept clean.
AVERTISSEMENT
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appar eil. Risque de brûlures
d'air de l'appareil soient gardés propres.
It is not unusu al for gas fireplaces to give o ff some odors the first time the y are burned. This is due to the oils and sealants in the manufacturing process. PLEASE ENSURE YOU ROOM IS WELL VENTILATED DURING BURN OFF – OPEN ALL WINDOWS
de contraction pendant le démarrage ou cycle de refroidissement. Il n'est pas inhabitu el po ur les foyers à gaz de dégager certaines odeurs la première fois qu'ils sont brûlés. Cela est dû aux huiles et produits d'étanchéité dan s le processus de fabrication. S'IL VOUS PLAÎT VOUS ASSURER pièce est bien aérée pendant BRÛLER - Ou vrir toutes les fenêtres Il est recommandé que vous brû lez votre foyer pendant au moins 4 (qu at re) heures la première
furniture, gasoline and other liquids having flammable vapors aw ay. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers , young children and at risk individuals out of the room and away from hot surfaces.
Any safety screen or guard removed for servicing an appliance must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The applia nce should
be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material, et
cetera. It is imperative that control compartments, burners and circulating air passageways
graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres
liquides produisant des vapeur inflammables loin de l’appareil.
Les tout-petits, les jeunes enfants et d'autres peuvent être sensibles aux brûlures par
contact accidentel. Une barrière physique est recommandé s'il ya des personnes à risque
dans la maison. Pour restreindre l'accès à une cheminée ou un poêle installer une barrière
de sécurité réglable pour garder les tout-petits, les jeunes enfants et les personnes à risque
de la salle et à l'écart des surfaces chaudes.
Tout écran ou grille de protection pour l'entretien d'un appareil doit être re m placé avant de
faire fonctionner l'appareil.
Installation et réparation doit être effectuée par un technicien qualifié. L'appareil doit être
inspecté avant son utilisation et au moins annuellement par un technicien qualifié. Un
nettoyage plus fréquent peut être nécessaire en raison de peluches provenant des tapis,
literie, etc. Il est impératif que les compartiments de contrôle, les brûleurs et les conduits
Page 12 of 58
Page 13
2.0 OPERATION
1. Pressure Taps
10. Inlet Ports
2.1 LIGHTING INSTRUCTIONS - f or Int e rmittent Pilot
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instr u ctions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s inst ruct i ons.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. Do not attempt to light the pilot by hand.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety
information above on this label. If you don’t smell gas, go to the next step.
6. Turn on all electric power to the appliance.
7. Set thermostat to desired setting (or switch to "ON" if not using a thermostat).
8. If the appliance will not operate, follow the instructions " To Turn Off Gas To Appliance" and call your service technician or gas supplier.

TO TURN GAS OFF TO APPLIANCE

1.Set thermostat to lowest setting.
2.Turn on/off switch to off.
2. Main Valve Connection
3. Pilot Internal Solenoid Connection
4. Outlet Ports
5. Mounting Holes
7. Flow Control Screw
8. Pilot Connections
9. High/Low Connection
Page 13 of 58
Page 14
2.1 INSTRUCTIONS D' ALLUMAGE - Pilote intermittent
1. Prises de pression
10. Ports d'entrée
POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER
AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué
de déclencher un incendie ou une explosion entraînant des domma g es, des blessures ou la mort.
A. Cet appareil est équipé d'un dispositif d'allumage qui allume automatiquement le pilote. Ne pas tenter d'allumer le pilote à la main.
B. Avant d’allumer la veilleuse, reniflez tout autour de l’appareil pour décel eur une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous server des telephones se trouvant dans le bâtiment.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoinder le fournisseur, appelez le service des incendies.
C. Ne pousser ou tourner la manette d’admission do gaz qu’à la main. Ne jamais employer d’outil à cette fin. Si la manette reste coincée, ne tentez Pas de la réparer; appelez un technici an qualifié. Quiconque tente de forcer la manette ou de la réparer peut provoquer une explosion ou un
incendie.
D. N’utilisez pas cet appareil s’il a été plunge dans l’eau, meme partiellement. Faites inspecter l’appareil par un technician qualifié et remplacez toute
partie du système de contrôle et toute c ommande qui ont été plongés dans l’eau.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ! Lisez les instructions de sécurité sur la portion supérieure de cette etiquette.
2. Réglez le thermostat à la temperature la plus basse.
3. Coupez l’alimentation électrique de l’appareil.
4. Ne tentez pas d'allumer le pilote à la main.
5. Attendre cinq (5) minutes** pour laisser échapper tout le gaz. Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler une
odeur de gaz, Si vous sentez une odeur de gaz, AR RÉTEZ! Passez à l’étape B d es instructions de sécurité sur la portion supérieure (à gauche) de cette etiquette. S’il n’y a pas d’odeur de gaz , passez à l’étape suivante.
7. Mettez l’appareil sous tension.
8. Réglez le thermostat à la temperàture désirée.
9. Si l'appareil ne fonctionne pas, suivez les instructions "Pour couper le gaz à l'appareil" et appelez votre technicien ou votre fournisseur de gaz
COMMENT COUPER L’ADMISSION DE GAZ L’APPAREIL
1.Réglez le thermostat à la temperature la plus basse
2.Active r / OFF sur OFF.
2. Raccordement de la vanne principale
3. Pilote de connexion interne solénoïde
4. Ports de sortie
5. Trous de montage
7. Vis de réglage du débit
8. Connexions pilote
9. High/Low Connection
Page 14 of 58
Page 15
3.0 INSTALLATION
Do not connect 120 VAC to the gas control valve or it’s components as this will
composantes, car cela endommagerait la vanne.
ALL INSTALLATIONS REQUIRE VENTING.
Foyer au gaz à evacuation. N e pas utiliser avec du combustible solide
3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET DE SECURITE
Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard. See the warranty at the back of this manual for disclaimers regarding improper installation. This direct vent fireplace and it’s components are tested and safe when installed in accordance with this installation manual.
Lisez toutes les instructions avant de commencer l'installation et de les suivre attentivement lors de l'installation pour assurer un bénéfice et une sécurité maximales. Le non respect de ces instructions annule la garantie et peut présenter un risque d'incendie. Voir la garantie à l'arrière de ce manuel pour décharges de responsabilité concernant une mauvaise installation. Ce foyer à évacuation directe et ses composantes sont testés et sûrs lorsqu'il est installé conformément aux instructions de montage.
WARNING
damage the valve.
Ne pas communiquer 120 VAC à la valve de contrôle du gaz ou de ses
3.2 UNPACKING
Please check the appliance carefully for any damaged or missing components (specifically check the glass condition). Report any problems to your dealer within 30 days of purchase.
3.3 INSTALLATION
For satisfactory results it is necessary to plan certain aspects of the installation prior to the appliance’s final positioning. These include the vent system, the gas piping, and the fans wiring. Combustible surfaces such as the hearth, mantle, and facing must also be planned for. Be sure to leave adequate clearance for servicing and proper operation.
Pour des résultats satisfaisants, il est nécessaire de planifier certains aspects de l'installation avant le positionnement final de l'appareil. Il s'agit notamment du système de ventilation, les canalisations de gaz, et le câblage fans. surfaces combustibles tels que le foyer, le manteau, et en face doivent également être prévues pour. N'oubliez pas de laisser un espace suffisant pour l'entretien et bon.
NOTE
Vented Gas Fireplace Not for Use with Solid Fuel
TOUTES LES INSTALLATIONS exigez l'aération.
Page 15 of 58
Page 16
3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS
A = 58”
TO INTERNAL CEILING
B = 2”
TO INTERNAL BACK COMBUSTIBLES
C = 17.5”
TO BACK WALL FROM FRONT OF UNIT
D = 6”
FROM EDGE OF FIREPLACE TO SIDE WALL
E = 39”
FROM BOTTOM OF FIREPLACE TO METAL STUD
F = 2”
TO INTERNAL SIDE COMBUSTIBLES
G=45”
MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE
(SEE DIAGRAM NEXT PAGE)
0”
BASE OF UNIT TO FLOOR
NON-COMBUSTIBLE BOARD – 12" (305mm) x 54.25" (1378mm) WILL BE
SUPPLIED BY MANUFACTURER AND MUST BE ATTACHED TO TOP OF FIREPLACE
SEE DIAGRAM PAGE 18
MINIMUM CLEARANCES TO COMBUSTIBLES
Page 16 of 58
Page 17
When using paint or lacquer to finish the mantel, such paint or lacquer must be heat
Clearances are in accordance with local installation c odes an d th e re q ui rements o f the gas suppl i er . **The mantel placement chart on this page illustrates the allowable mantel sizes and placements. The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim.
Les dégagements sont en conformité avec les codes d'installation locaux et les exigences du fournisseur de gaz. ** Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles cheminée. L'angle de 45 degrés peut être utilisé pour déterminer la taille permise manteau repose sur l'élévation au-dessus de la garniture unités supérieures.
resistant ( up to 250o F ) to prevent discolorations. Lors de l'utilisation de peinture ou de laque à la fin de la cheminée, de peinture ou
CAU TION
ATTENTION
laque doit être résistante à la chaleur (jusqu'à 250o F) pour prévenir la décoloration.
Page 17 of 58
Page 18
FIREPLACE
39.00 TO
STUD ON
STUD
NON-COMBUSTIBLE BOARD 12 X 54.25 SUPPLIED BY MANUFACTURER
BOTTOM OF
EDGE
40.00 TO TOP OF NON- COMBUSTIBLE BOARD FROM BOTTOM OF
The closest combustible material above the fireplace must be a minimum of 40.00” from the floor with the stud laying on edge as shown above. / Le plus proche matériau combustible au-dessus du foyer doit être un minimum de 40.00" à partir du sol avec le goujon pose sur le bord, comme indiqué ci-dessus.
NON COMBUSTIBLE MATERIAL/ MATIERE NON COMBUSTIBLES
Non-combustible material will be supplied by the manufacturer. This must be installed on top of the fireplace as shown above to meet installation codes. Matériaux non combustibles seront fournis par le fabricant. Ce doit être installé sur le dessus du foyer, comme indiqué ci-dessus pour répondre aux codes d'installation.
Page 18 of 58
Page 19
3.3.2 GAS LINE INSTALLATION / INSTALLATION DE LA LIGNE de GAZ
WARNING
DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS
Upon initial firing check manifold pressure at pressure tap located on the front control
situé sur le panneau de commande avant (voir les Consignes d'allumage à la section 2.1).
Install supply line using any piping approved for your installation meeting CAN/CGA 6.10, AA 3, ANSI Z21.24 or
Z21.45. A qualified gas fitter should instal l the gas line in acc ordance with all loc al building codes. If codes permit, coiled copper tubing may be used for gas supply.
Installez la ligne d'approv isionnement en utilis ant toute la tuyauterie appr ouvé pour votre réunion d' installation CAN /
CGA 6.10, AA 3, ANSI Z21.24 ou Z21.45. Un installateur de gaz qualifié doit installer la canalisation de gaz en conformité avec les codes du bât iment locaux. Si les codes le perm et tent, tube d e c uivre enro ul é peu t êtr e uti lisé po ur l'approvisionnement en gaz.
Pressure taps are pr ov ide d on t he g as contr o l f or test gauge connections to measure the manifold and in let p r ess ur es
(see Lighting Instructions).
Les sont fournis sur la com mande de gaz pour les connexions prises de pression gabarit d'ess ai pour mesurer les
pressions multiples et d'une entrée (voir les Consignes d'allumage).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).
Cet appareil doit être isol é de l'alimentation en gaz en f ermant son robinet arrêt pend ant tout test de pression de la
canalisation de gaz à une pression égale ou inférieure à 1/2 psi (3.45 kPa).
The appliance and its a ppliance m ain gas valve must be disconnec ted from the gas suppl y piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
L'appareil et son robinet d’arrêt doit être déconnectée de la canalisation de gaz pendant tout test de pression du système à des pressions
supérieures à 1/2 psi (3.45 kPa).
Install the gas line as follows: The appliance shall be installed with a manual shut off ball valve and additional pressure regulator to bring line pressure down to 14” w.c.. Installez la conduite de gaz comme suit:
L'appareil doit être installé avec une vanne manuelle à billes et régulateur de pression supplémentaire pour faire
pression ligne vers le bas à 14 "wc.
panel (see Lighting Instructions in section 2.1 ).
NOTE
Lors de la première vérification de la pression de tir collecteur à la pression du robinet
AVERTISSEMENT
NE PAS UTILISER UNE FLAMME DE TEST DE FUITES DE GAZ
Page 19 of 58
Page 20
3.3.3 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION
If at any time the vent-air intake piping is dismantled, use the vent manufacturer’s
remontage
The unit must be connected to listed 2-ply aluminium venting, 4” flex vent on the exhaust side and listed 7” flex vent on the air intake side or can be used with Security Venting, Dura-Vent 4” x 6-5/8” with the use of Dura-Vent adapters part #’s 0924N3 & P574, Selkirk Direct-Temp Venting with Dura­Vent adapter part # 0924N3, IC C v enti ng w i th adapter par t # TM-4AA2 or Metal-Fab dir ect v enti ng with the use of Metal-Fab adapter part # 4DDA . Install the vent components according to the manufacturer's instructions being sure to use spacers (see Figure 5) every 5’ to ensure correct spacing is maintained between air intake and exhaust. Slope horizontal pipe at least 1/4" (6 mm) rise per foot of horizontal run away from the fireplace. Allow 1" (25 mm) clearance to the vent. Refer to the graph for allowable vent configurations. Be sure to ensure that termination area allows enough room for adequate combustion and ventilation air and that the flow of combustion and ventilation air is not obstructed. L'appareil doit être connecté à cotée 2 couches d'aluminium ventilation , 4 "flex évent sur le côté de l'échappement et répertoriés 7 " flex évent sur le côté d'admission d'air ou peut être util is é avec sécurité ventilation , Dura-Vent 4 "x 6-5 / 8 " avec l'utilisation d'adaptateurs Dura -Vent 0924N3 & P574 partie les # 's , Selkirk Direct -Temp évacuation avec Dura-Vent adaptateur partie # 0924N3 , CPI évacuation avec adaptateur partie # TM- 4AA2 ou Metal-Fab évacuation directe à l'utilisation de Metal-Fab adaptateur partie # 4DDA . Installez les composants de ventilation selon les instructions du fabricant en veillant à utiliser des entretoises ( voir figure 5) tous les 5 ' pour assurer un espacement correct est maintenu entre l'apport d'air et l'échappement. Pente tuyau horizontal d'au moins 1/4 " ( 6 mm ) par pied de course horizontale loin du foyer . Laisser 1 " ( 25 mm) à l'évent . Reportez-vous au graphique de configuration de l'évacuation admissibles . Veillez à ce que la zone de terminaison permet assez de place pour combustion et l'air de ventilation et que le débit de combustion et de l'air de ventilation n'est pas obstruée.
instructions and the sealing instructions for reassembly.
Si à tout moment de la tuyauterie d'admission d'air de ventilation est démontée, utilisez
NOTE
This appliance’s venting system is room sealed or Direct Vent. This means that it does not require room air for combustion but draws air from outside the building.
USE OF COUPLERS – WITH FLEX PIPE
In the event of a puncture of the vent pipe or if an extension is needed couplers may be used. High temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted into the flex vent. Use 3 #8 x ½” hex head sheet metal screws on each end of the joint to fasten the coupler to the venting.
la ventilation instructions du fabricant et les instructions d'é tanché ité pour le
Figure 5
Page 20 of 58
Page 21
Figure 6
Dura-Vent or Selkirk Direct-Temp Venting

The minimum vent system for horizontal termination must consist of:

Dura-Vent adapter Part # 0924N3 directly on top of unit 15” (305mm) vertical length of vent 90 degree elbow 15" (305 mm) length horizontally
Wall thimble part #IMC1082A Dura-Vent Horizontal termination cap 0984/ or / Selkirk Horizontal termination cap 4DT-HC The maximum horizontal vent system consists of:
Dura-Vent adapter Part # 0924N3 directly on top of unit
34' (10363 mm) vertical length directly on top of the stove 4 - 90 degree elbows 20' (6096 mm) maximum horizontal length
Wall thimble part# IMC1082A
Dura-Vent Horizontal termination cap 0984/ or / Selkirk Horizontal termination cap 4DT-HC The maximum vertical system consists of:
Dura-Vent adapter Part # 0924N3 directly on top of unit
Up to 34' (10363 mm) of vertical length Fire stop Flashing Collar Dura-Vent Termination cap part # 0991/ or / Selkirk Termination cap part # 4DT-VC
ICC VENTING

The minimum vent system for horizontal termination must consist of:

ICC adapter Part # TM-4AA2 directly on top of unit
15” (305mm) vertical length of vent
90 degree elbow
15" (305 mm) length horizontally
Wall thimble part # TM-4WT
Horizontal termination cap TM-4HT The maximum horizontal vent system consists of:
ICC adapter Part # TM-4AA2 directly on top of unit
34' (10363 mm) vertical length directly on top of the stove 4 - 90 degree elbows 20' (6096 mm) maximum horizontal length
Wall thimble part# TM-4WT
Horizontal termination cap TM-4HT
The ma ximum vertical system consists of:
ICC adapter Part # TM-4AA2 directly on top of unit
Up to 34' (10363 mm) of vertical length Fire stop Flashing Collar Termination cap part # TM-4VT
Page 21 of 58
Page 22
Security Venting

The minimum vent system for horizontal termination must consist of:

Dura-Vent adapter Part # 0924N3 directly on top of unit
15” (305mm) vertical length of vent
90 degree elbow
15" (305 mm) horizontal length of vent
Wall thimble part #IMC1082A

Horizontal terminati on c ap SV4CHC The maximum horizontal vent system consists of:

Dura-Vent adapter Part # 0924N3 directly on top of unit
34' (10363 mm) vertical length directly on top of the stove 4 - 90 degree elbows 20' (6096 mm) maximum horizontal length
Wall thimble part# IMC1082A
Horizontal terminati on c ap SV4CHC The maximum vertical system consists of:
Dura-Vent adapter Part # 0924N3 directly on top of unit
Up to 34' (10363 mm) of vertical length Fire stop Flashing Collar
Termination cap part # SV4CGV Use a ceiling fire stop when penetrating a ceiling or floor. Use a wall thimble when penetrating an inside or outside wall. Vent terminals shall not be recessed into a wall or siding.
Metal-Fab Venting

The minimum vent system for horizontal termination must consist of:

Metal-Fab adapter Part # 4DDA directly on top of unit 15” (305mm) vertical length of vent 90 degree elbow 15" (305 mm) length horizontally Wall thimble part #IMC1082A Horizontal terminati on c ap 4DHT

The maximum horizontal vent system consists of:

Metal-Fab adapter Part # 4DDA directly on top of unit 34' (10363 mm) vertical length directly on top of the stove 4 - 90 degree elbows 20' (6096 mm) maximum horizontal length
Wall thimble part# IMC1082A Horizontal terminati on c ap 4DHT The maximum vertical system consists of:
Metal-Fab adapter Part # 4DDA directly on top of unit Up to 34' (10363 mm) of vertical length Fire stop Flashing Collar Termination cap part # 4DVT
Page 22 of 58
Page 23
2-Ply Aluminum Flex Vent

The minimum vent system for horizontal termination must consist of:

15” (305 mm) vertical length (measured to center of vent pipe) with a 90 degree bend and a
15” (305 mm) horizontal length (measured from center of vent pipe)
Wall thimble part# IMC1082A Horizontal termination cap part # IMC1070A or IMC1070B

The maximum horizontal vent system consists of:

34’ (10363 mm) vertical length with a 4 - 90 degree bends and a 20’ (6096 mm) horizontal
length (measured to center of vent pipe) Wall thimble part# IMC1082A
Horizontal termination cap part # IMC1070A or IMC1070B Note: 2-Ply Horizontal venting shall be supported, by means of a steel strap, every 3’. The maximum vertical system consists of:
Up to 34' (10363mm) of vertical length Fire stop Flashing Collar Adapter from flex to Simpson Dura-Vent part #P574 Termination cap part # 0991
A maximum of 4 – 90 degree bends can be used on the vertical in s tallation venting. The maximum height for this vent configuration is 34’ (10363 mm) and the minimum height is 4’ (1200 mm). The maximum horizontal run is a total of 20’ (6096mm). When fastening the flex vent to the termination and to the unit use a minimum of 3 # 8 x ½” hex head sheet metal screws on the 4” vent and a minimum of 4 - # 8 x ½” hex head sheet metal screws on the 7” vent.
Page 23 of 58
Page 24
VERTICAL VENT TABLE
EXAMPLES
MINUMUM VERTICAL (V1 + V2 + V3)
MAXIMUM HORIZONTAL (H1 + H2)
4’
10’ 8’
20’
MAXIMUM VERTICAL HEIGHT = 34 ’ MAXIMUM 90° ELBOWS PERMITTED = 4
EXAMPLES
MINUMUM VERTICAL (V1)
MAXIMUM HORIZONTAL (H1 + H2 + H3 + H4)
4’
10’
8’
20’
NOTE: All vent dimensions are measured from the
V1
H1
H2
H3
H4
V1
V2
V3
H1
H2
(All values are in feet)
appliance surface where the vent connects to the point where exhaust gases exit the termination.
REMARQUE: Toutes les dimensions sont mesurées à partir d'aération de la surface de l'appareil où l'évent se connecte au point où les gaz d'échappement de sortie de la résiliation.
HORIZONTAL VENT TABLE
(All values are in feet)
MAXIMUM HORIZONTAL OFFSETS = 20’
Page 24 of 58
Page 25
34’
20’
A
A
B
B
15” MINIMUM
15” MAXIMUM

(Example: Where A---A = Vertical @ 2 ½’

And B---B = Horizontal @ 5’)
Page 25 of 58
Page 26

USE OF SEAL ANT

A minimum clearance to combustibles must be maintained around the vent pipe of 1”
Vent Configuration
Restrictor Size
SEE PAGE 27
60%
SEE PAGE 27
40%
SEE PAGE 27
20%

Apply RTV high temperature

Restrictor plate
Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints (figure 7). On longer vent runs, especially vertical runs, sealant will ensure that the combustion air enters from outdoors, and not through the vent joints. Use high temperature sealant, available from local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the vent. A bead of silicone should be used on the outside of the joint after assembly to seal the supply air. If the venting is disconnected for servicing, be sure to follow above instructions for resealing
on all horizontal and vertical pipe runs
Un dégagement minimum aux matériaux combustibles doit être mainte nu autour du
NOTE
tuyau de 1 "sur toutes les canalisations horizontales et verticales fonctionne
venting when reconnecting to system.
FIGURE 7

sealant around male pipe.

VENT RESTRICTOR INSTALLATION

VENT RESTRICTOR
To fasten the Restricto r Plate to the ceiling of the firebox: 1/. Remove the 2 screws that are in place 2/. Align holes in the Restrictor that match the required degree of restriction 3/. Fasten Restrictor Plate back in place.
Page 26 of 58
Page 27
Typical Dura- Vent, Security Chimney & Metal-Fab Venting Installation:
ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD
des risques d'incendie.
Fireplace
Vent terminals shall not be recessed into a wall or siding.
Horizontal Wall Vent Terminations
The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes. Attach the correct length of pipe. Mark the center line of the pipe facing the wall (allowing for a 1/4” rise per foot of horizontal, example 10 ft of horizontal would require a rise of 2.5”).
CAUSE POOR COMBUSTION AND/OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE
HAZARD.
NOTE
PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT
PROVOQUER une mauvaise combustion et / ou de températures élevées qui peuvent présenter
Page 27 of 58
Page 28
13.00”
10.00”
10.00”
Ø 9.00”
13.00
10 x 10 MIN OPENING
WALL THIMBLE 9"
OUTER PIPE 7”
VIEW OF SAFETY CAGE
Mark a 10” x 10” square around the center mark (inside dimensions). Cut and frame the exterior wall to accept the wall thimble. Install the wall thimble, on the inside of the exterior wall, shield using wood screws.
Attach the venting to the termination using sheet metal screws, for Z-Flex installations an Sierra Flame’s termination part # IMC1070A or IMC1070B shall be used and when using Simpson Dura-Vent or Security Venting a Simpson Dura-Vent termination part # P574 shall be used. If termination is to be installed on vinyl siding using vinyl siding standoff part # IMC1151.
To install the termination attach the 4” exhaust to the termination and fasten with 3 #8 x ½” hex head sheet metal screws then attach the 7” vent to the termination and fasten with 4 #8 x ½” hex head sheet metal screws, be sure that the flex vent overlaps the termination collars a minimum of 2”. Then attach the termination to the exterior wall using four wood screws through the holes in the corner of the vent terminal. The next step is to apply a bead of mil-pac or RTV 106 to top of the 4” exhaust collar on the unit and attach the 4” vent using screws (as described above), finally apply a bead of mil-pac or RTV 106 to top of the 7” vent and attach (as described above).
Safety Cage / Cage de sécurité
A safety cage may be required on low terminations. Please check with your local safety authority. Une cage de sécurité peut être nécessaire de faibles terminaisons. S'il vous plaît vérifiez auprès de votre autorité de sécurité locale.
Page 28 of 58
Page 29
Vertical Installations
ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING. CLEARANCES ETC,
varier d'ÉTAT (PROVINCE).
CONSULT DURAVENT PARTS LIST OR SIERRA FLAME’S FIREPLACE MANUFACTURING PARTS
FLAME de fabrication POUR LA LISTE DES PIÈCES DE RÉFÉRENCE.
9” x 9” opening
Always maintain a 1” clearance around the vent pipe (vertical) and 1” clearance horizontal, when passing through ceilings, walls, roofs, enclosures, attic rafter or any combustible surfaces.
DO NOT PACK AIR SPACES WITH INSULATIO N
NE PAS PACK ESPACES D'AIR AVEC ISOLATION
NOTE
When passing through a flat ceiling install a Box/Wall thimble. Cut a 9” square hole and frame as shown in
the diagram below.
MAY VARY FROM STATE TO STATE (PROVINCE TO PROVINCE).
TOUJOURS vérifier les codes locaux avant l'installation VENTILATION. ETC DÉGAGEMENTS, peut
NOTE
LIST FOR PART NUMBERS.
CONSULTER LA LISTE DES PIÈCES DES FOYER DURAVENT OU LA LISTE DES PIÈCES SIERRA
NOTE
See section 3.3.4 Venting for instructions on how t o connect Security or Dura-vent venting.
Page 29 of 58
Page 30
Termination above Roof
grade
Consult local codes for minimum vent cap height above the roof (X), vent must be a minimum of 2’ from any wall.
To prevent water seepage; install the flashing with upper portion under the roofing material and the lower portion over the roofing material. Note: Do not fasten down until the final adjustments to the vent have been made.
The diagram at right shows the minimum clearances as per the chart on page 33.
3”
12” from
Page 30 of 58
Page 31
0” 0”
3” 3”
In accordance with the current CSA B149.1,
A vent shall not terminate directly above a sidewalk or paved driveway that is located
Permitted only if veranda, porch, deck or
one of the following
24” 24”
J= Clearance to nonmechanical 6 in (15cm) for appliances ≤10,000 6 in (15cm) for appliances ≤10,000 air supply inlet to building or Btuh (3kW), 12 in (30 cm) for Btuh (3kW), 9 in (23 cm) for the combustion air inlet to appliances >10,000 Btuh (3kW) and appliances >10,000 Btuh (3kW0 and any other a ppliance 100,000 Btuh (30kW), 36 in (91 cm) 50,000 Btuh (15kW), 12 in (30cm) for appliances >100,000 Btuh (30kW) for appliances >50,000 Btuh (15kW0
K= Clearance to a mechanical 6 ft (1.83 m) 3 ft (91 cm) above if within 10 ft air supply inlet (3 m) horizontally
L= Clearance above paved sidewalk 7 ft (2.13 m) or paved driveway located on public property *
M= Clearance under veranda, 12 in (30 cm) porch deck or balcony *
1
Natural Gas and Propane Installation Code
2 In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code
between two single family dwellings and serves bot h dwellings
balcony is fully open on a minimu m of tw o
sides beneat h the floor
* For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA B149. 1
shall be indicated
a). A minimum clearance value determined by testing i n accordance with section 2.23.5, or:
b). A reference to the following footnote: “Clearance in accordance with local installation codes and the requirements of the gas supplier.”
Page 31 of 58
Page 32
WARNING
AVERTISSEMENT
YOU MUST WEAR FLAME AND HEAT RESISTANT GLOVES FOR THESE ADJUSTMENTS.
Burn medium positions are critical to the safe and clean operation of this appliance.
graver moyen fourni avec cet appareil.
This shows positions of media critical to correct flame pattern.
Shown with optional driftwood logs
3.3.4 GLASS INSTALLATION / INSTALLATION DE VERRE
Never add any other material into the firebox. Use only with burn medium supplied with this unit. Positions Burn moyennes sont critiques pour le fonctionnement sûr et propre de cet
CAU TION
ATTENTION
appareil. Ne jamais ajouter d'autres matériaux dans le foyer. Utilisez uniquement
Step 1. Sprinkle burner channel with glass. Make sure to cover the burner pan evenly. Then add decorative rocks to outer pan area. / Saupoudrer le canal du brûleur avec verre. Assurez-vous de couvrir la casserole du brûleur de façon égale. Puis ajoutez les roches décoratives à la zone pan extérieur.
Step 2 Make sure that only the glass covers the burner holes. / Assurez-vous que seul le verre recouvre les trous du brûleur.
Install the door see instructions below. Replace lower access strip in front of door / Installez la porte voir les instructions ci-dessous. Remplacer la bande inférieure d'accès en face de la porte
Turn your fireplace on and wait approximately 10-15 minutes until the flames are a nice yellow colour. Note the flame pattern and in any low or high areas adjust the amount of river glass to correct gas flow. / Transformez votre cheminée et attendez environ 10-15 minutes jusqu'à ce que les flammes sont une belle couleur jaune. Notez la forme de la flamme et dans tous les domaines à basse ou haute ajuster la quantité de verre rivière pour corriger débit de gaz.
VOUS PORTER DES GANTS DE FLAMME ET RESISTANT A LA CHALEUR DE CES
AJUSTEMENTS.
Page 32 of 58
Page 33
Page 33 of 58
Page 34
3.3.5 DOOR INSTALLATION / INSTALLATION DE LA PORTE
Place the bottom of the door into the Bottom Door Channel / Placez le bas de la porte dans la Manche de bas de porte
DOOR LOCK BRACKETS
Insert your index fingers into gap at top of door and behind tabs on door lock bracket. Pull bracket towards you and over the lock to clip down into place. / Insérez vos index en écart au sommet de la
porte et derrière onglets sur support de verrouillage de porte. Tirez support vers vous et sur le verrou pour attacher le mettr e en place.
Page 34 of 58
Page 35
When closed properly the door latch will hook over the top of the door bracket and seal the door onto
It is normal for the appliance to expand and contract while it heats up or cools down whether
métalliques peuvent produire des sons
Do not operate this appliance with the glass front removed, cracked or broken.
Ne pas les portes en verre d'abus, par la suppression ou claquement fermé
the fireplace. / Quand il est fermé correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la cheminée.
Removal is in reverse order. / L'enlèvement est dans l'ordre inverse. If the glass has been damaged or broken it is highly recommended that you contact a qualified service person. Remove the broken pieces (be sure to wear gloves) and remove door. See the replacement parts list, at the end of the manual, you will require one 5 mm ceramic glass panel with gasket installed. Lay in a blob of high temperature silicone in each of the four corners of the do or Then follow the instructions above to re-install the door. Si le verre a été endommagé ou cassé, il est fortement recommandé que vous contactez une personne qualifiée. Retirez les morceaux (n'oubliez pas de porter des gants) et enlever la porte. Voir la liste des pièces de rechange, à la fin du manuel, vous aurez besoin d'un panneau de verre 5 mm en céramique avec un joint installé. Laïcs dans une goutte de silicone à haute température dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le panneau de verre de nouveau dans le cadre de la porte. Puis suivez les instructions ci-dessus pour ré-installer la porte.
Replacement of the glass should be done by a licensed or qualified service person.
For use with glass doors certified with the appliance only
Do not use any substitute materials
Do not abuse glass doors by striking or slamming shut
Ne pas faire fonctionner cet appareil avec la façade en verre est enlevée, fissurée ou cassée. Remplacement de la vitre doit être effectué par un technicien spécialisé ou agrée.
WARNING
AVERTISSEMENT
Pour utilization uniquement avec les portes en verre certifies avec l’appareil
Ne pas utiliser de matériaux de substitution
3.3.6 INITIAL FIRING When lit for the first few times, the applia nce may emit an odor resulting from evapora ti on o f paint an d
lubricants used in the manufacturing process. Open a door or window for ventilation. Anyone with a respiratory condition may need to leave the room during the initial firings.
this is from a cold start or a steady-state condition where the fan has come on or off. Under
these circumstances it is possible that the expansion/contraction of the metal parts may
produce sounds.
Il est normal que l 'appareil à dilater et se contracter pendant qu'elle se réchauffe ou se refroidit
NOTE
s'il s'agit d'un démarrage à froid ou d'un état d'équilibre où le ventilateur est venu sous ou hors
tension. Dans ces circonstances, il est possible que l'expansion et la contraction des pièces
Occasionally, after a cold start, vapor may condense and fog the glass, and the flames may be partially blue. After a few minutes the moisture will disappear and the flames will become yellow. Visually check the flame after warm-up. / Parfois, après un démarrage à froid, la vapeur peut se condenser et voiler le verre, et les flammes peuvent être partiellement bleu. Après quelques minutes, l'humidité disparaît et les flammes deviendront jaunes. Contrôler visuellement la flamme après l'échauffement.
Page 35 of 58
Page 36
3.3.7 PILOT FLAME ADJUSTMENT
PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT.
PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE
Air tube and Air shutter shown removed
Set Screw
For proper operation, t he pilot and m ain burner flames must be steady and not lif ting off or f loating. The top 3/8” – 1/2” (10-13mm) of the Thermocouple should be engulfed by the pilot fl ame.

3.3.8 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE

Aeration is factory set but may need adjustment for altitude or movement during shipping. / L'aération est réglée en usine, mais peut néc es s i ter un ajustement de l'altitude ou le mouvement pendant le transport . To adjust the air shutter / Pour ajuster l'obturateur d'air 1/. Turn off the gas / Fermez le gaz 2/. Remove the door / Enlevez la porte 3/. Remove glass or logs from burner / Retirer le verre ou des billes de brûleur 4/. Remove the burner pan / Retirer la casserole du brûleur 5/. Undo the set screw on the air shutter and adjust accordingly then r etighten the set screw. / Défaire la vis de réglage sur le volet d'air et d'aj us ter en conséquence, puis resser r ez la vis de
réglage.
for clarity purposes only.
6/. Reassemble the fireplac e i n r everse order from 4 through 2. / Remonter la cheminée dans l'ordre inverse de 4 à 2. 7/. Turn on the gas. / Allumez le gaz.
CAUTION ATTENTION
Factory Setting
Natural Gas – open 3/8” (9.525mm)
Propane Gas – Fully Open
Aeration adjustment is important for the correct functioning of the appliance. Carbon build up, flame lifting or any malfunction due to improper aeration adjustment during installation is not covered under the factory warranty. Réglage de l'aération est importante pour le fonctionnement correct de l'appareil. Une accumulation de carbone, de levage flammes ou de toute défaillance due à une mauvaise aération d'ajustement lors de l'installation n'est pas couvert par la garantie d'usine.
Page 36 of 58
Page 37
3.3.9 ALTITUDE ADJUSTMENT
Altitude
Natural Gas –
Orifice Size
Propane Gas –
Orifice Size
0 – 2000 ft (0 – 610 m)
45
56
2000 – 4000 ft (610 - 1219 m)
46
57
4000 – 6000 ft (1219 - 1829 m)
47
58
TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE
GAZ
Burner pan
Access Panels
All valves have been pre-set and certified for installation at elevations from 0 – 2000 feet (0-610m) above sea level. When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 2000 feet (610m). The appliances input should be reduced 4% for each additional 1000 feet (305m) above sea level. For the USA, de­rate the unit from sea level according to the gas installation code.
Toutes les vannes ont été pré-programmées et certifié pour l'installation à une altitude de 0 à 2000 pieds (0-610m) d’altitude Lors de l'installation de cet appareil à haute altitude, il est nécessaire de baisser la note d'entrée par le remplacement de l'orifice du brûleur existant avec une taille plus petite pour les installations de plus de 2000 pieds (610m). L'entrée des appareils devrait être réduite de 4% pour chaque 1000 pieds supplémentaires (305m) au-dessus du niveau des mers. Pour les États-Unis, de taux de l'unité de niveau de la mer selon le code d'installation de gaz
3.3.10 FAN ACCESSIBILITY / FAN ACCESSIBILITÉ
FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER
N
CAUTION
ATTENTIO
TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT
TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE
1/. Remove lower access panel fro m in front o f do or . Remove the door as in 3.3.5 / Retirez du panneau d'accès inférieur en face de la porte. Enlevez la porte comme dans 3.3.5
2/. Remove the burner pan by undoing the screws at front and back of pan. Remove the burner carefully. / Retirer la casserole du brûleur en dévissant les vis à l'avant et l'arrière du poêle. Retirez le rûleur avec soin.
Page 37 of 58
Page 38
Showing the left Access Panel
with burner pan removed
Pilot Box
3/. Remove the access panels, one on either side of the pilot box / Retirer les panneaux d'accès, une de chaque côté de la zone pilote
4/. The fan is attached with magnets for ease of installation and can be pulled off the rear wall. / Les fan sont attachés avec des aima nts pour la facilité d'installation et peut être retiré de la paroi arrière
5/. Once removed from the wall the fan will slide out through the opening. / Une fois retiré du mur que les fan vont glisser par l'ouverture.
6/. To replace fan and reassemble the fireplace go in reverse order from steps 5 through 1. / Pour remplacer les fan et montons la cheminée aller dans l'ordre inverse des étapes 5 à 1.
Page 38 of 58
Page 39
The pictures above show the electrical box that controls the fan, the power cord attached and the
TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE
GAZ
WARNING
BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL GAS CONNECTIONS AFTER REINSTALLATION OF VALVE.
RÉINSTALLATION DE LA VANNE.
SCREW
strain relief connected to the box. / Les photos ci-dessus montrent la boîte électrique qui contrôle le ventilateur, le cordon d'alimentation fourni et le réducteur de tension connecté à la boîte.
3.3.11 GAS VALVE ACCESSIBILITY / ACCESSIBILITÉ ROBINET DE GAZ.
FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER
TOURNEZ LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT
CAUTION
TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE
ATTENTION
1/. Remove the front access panel from below the door. Remove the door as in 3.3.5 / Retirez le panneau d'accès avant d'en bas de la porte. Enlevez la porte comme dans 3.3.5
2/. Undo the screws on the valve mount brackets at either end of the valve and slide valve out through access panel below door. / Défaire les vis sur les supports de montage de soupape à chaque extrémité de la soupape et de soupape coulissant à travers le panneau d'accès inférieur de la porte.
AVERTISSEMENT
IL EST INDISPENSABLE DE VÉRIFIER LES FUITES DE GAZ A TOUS LES CONNEXIONS DE GAZ APRÈS LA
Page 39 of 58
Page 40
WARNING
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
4.0 MAINTENA NCE
4.1 MAINTENANCE SAFETY / SÉCURITÉ ENTRETIEN
AVERTISSEMENT
30 MINUTES BEFORE SERVICING.
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
Service and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service technician. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is important that the access door compartment, burner, and circulating air passageways be kept clean to provide for adequate combustion and ventilation airflow. Do not substitute materials or use components other than factory supplied. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable liquids and vapors. Entretien et réparation doit être effectuée par un technicien qualifié. L'appareil doit être inspecté avant son utilisation et au moins une fois par an par un technicien de service professionnel. Un nettoyage plus fréquent peut être nécessaire en raison des peluches provenant des tapis litière, etc Il est important que des passages d'air du compartiment porte d'accès, le brûleur et circulant être maintenu propre pour fournir une combustion adéquate et ventilation d'air. Ne pas remplacer les matériaux ou utiliser des composants autres que l'usine fournie. La zone appareil doit rester clair et exempt de matériaux combustibles, essence et autres vapeurs et liquides inflammables.
4.2 RECOMMENDED SERVICE / SERVICE RECOMMANDÉ
1. The venting system should be annually inspected by a qualified agency. / Le système de ventilation devrait être inspectés annuellement par une agence qualifiée.
2. Visually check the burner and pilot flames occasionally. Visually inspect height and color of
flames / Contrôler visuellement le brûleur et les flammes pilotes à l'occasion. Inspecter visuellement la hauteur et la couleur de flammes
3. Clean the glass as needed. See section 4.3 for instructions on glass cleaning. / Nettoyez la vitre au besoin. Voir la section 4.3 pour obtenir des instructions sur le nettoyage du verre.
4. Have the appliance inspected annually by a professional service technician. / Avez l'appareil inspecté annuellement par un technicien de service professionnel.
5. Clean the appliance regularly. / Nettoyez l'appareil régulièrement.
Annual service: An annual service call should take between 1 – 2 hours. Start by disassembling the unit; take off the door and remove all the embers, burner, and logs. Clean fan with a vacuum to remove any dust. Vacuum the whole firebox and all the air passages. Clean the burner. After everything is clean, check all the connections and the chassis ground and reassemble. Clean the glass.
L'entretien annuel: Un appel de service annuelle devrait prendre entre 1 - 2 heures. Commencez par démonter l'unité; décoller la porte et retirez tous les braises, le brûleur et les journaux. Nettoyer ventilateur avec un aspirateur pour enlever toute trace de poussière. Passez l'aspirateur sur le foyer
Page 40 of 58
Page 41
entier et tous les passages d'air. Nettoyer le brûleur. Après tout est propre, vérifier toutes les
WARNING
AVERTISSEMENT
THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY
connexions et la masse du châssis et montons. Nettoyez la vitre.
4.3 GLASS CLEANING / NETTOYAGE DE LA VITRE
The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air. For best results, use a ceramic glass cleaner or polish. Use a cleaner suitable for ceramic glass (e.g. cerama bryte stove cleaner). Avoid the use of ammonia based cleaners such as Windex®. Do not clean while hot. Do not use abrasive cleaners. Make sure you clean off any white film on the fireplace glass as soon as possible – otherwise the glass may deteriorate. L'intérieur de la vitre peut nécessiter un nettoyage périodique pour enlever les dépôts laissés par des impuretés dans le gaz et l'air de combustion. Pour de meilleurs résultats, utilisez un nettoyant à vitres en céramique ou en polonais. Utiliser un nettoyant approprié pour le verre en céramique (par exemple Cerama propre poêle Bryte). Évitez l'utilisation de nettoyants à base d'ammoniac comme Windex ®. Ne pas nettoyer à chaud. Ne pas utiliser de nettoyants abrasifs. Assurez-vous de nettoyer n'importe quel film blanc sur la vitre cheminée dès que possible - sinon le verre risque de se détériorer.
4.4 BURNER & PILOT CLEANING / BRULEUR ET NETTOYAGE DE PILOTE
Periodic cleaning is necessary for proper operation. Remove the burner, and check that the burner orifice is clean. Visually inspect the pilot. Brush or blow away any dust, lint, or foreign debris. If the pilot orifice is plugged, disassembly may be required to remove any foreign material from the orifice or tubing. W hen the appliance is back in service, check the pilot flame pattern. For re-lighting, refer to the lighting instructions in Section 2.1. Un nettoyage périodique est nécessaire pour un fonctionnement correct. Enlever le brûleur, et vérifier que l'orifice du brûleur est propre. Inspectez visuellement le pilote. Brossez ou soufflez la poussière, les peluches ou les débris étrangers. Si l'orifice pilote est branché, le démontage peut être nécessaire pour éliminer toute matière étrangère de l'orifice ou un tube. Lorsque l'appareil est remis en service, vérifier le modèle flamme de la veilleuse. Pour ré-éclairage, reportez-vous aux instructions d'éclairage dans la section 2.1.
4.5 VALVE AND PILOT ASSEMBLY REPLACEMENT / SOUPAPE ET
REMPLACEMENT ENSEMBLE PILOTE
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
30 MINUTES BEFORE SERVICING.
LA PROCÉDURE SUIVANTE EST EFFECTUER PAR DU PERSONNEL QUALIFIÉ
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
1. Turn off the gas at the meter. / Coupez le gaz au compteur.
2. Remove the door. / Enlevez la porte.
Page 41 of 58
Page 42
3. Remove the burner by loosening the screws and lifting it out see section 3.3.9. If the decorative glass is removed from the burner pan make sure you do not get any medium around the pilot when replacing it. / Enlever le brûleur en desserrant les vis et en soulevant it out voir la section
3.3.9. Si le verre décoratif est retiré de la cuvette du brûleur assurez-vous que vous ne recevez pas n'importe quel support autour du pilote lors de son remplacement.
4. Disconnect the gas line to the appliance and disconnect the gas line from the valve to the main orifice. / Débrancher la conduite de gaz à l'appareil et débranchez la conduite de gaz de la vanne à l'orifice principal.
5. Remove the screws holding the valve bracket to the base of the unit and lift valve & valve bracket out. / Retirez les vis de fixation du support de la valve à la base de l'unité et de levée de soupape et support de la valve.
6. Undo the pilot gas line at the gas valve. / Annuler la conduite de gaz pilote à la vanne de gaz.
7. Disconnect the thermostat or on/off switch wires from the valve (if applicable). / Débranchez le thermostat ou marche / arrêt fils de l'interrupteur de la vanne (si applicable).
8. Remove the gas line to the valve inlet and outlet. / Retirer la conduite de gaz à l'entrée de la vanne et la sortie.
9. Remove the screws which hold the valve to the valve bracket. / Retirez les vis qui maintiennent la vanne sur le support de la vanne.
10. Remove the screws fastening the pilot assembly to the pilot bracket and remove the pilot assembly. / Retirez les vis de fixation du assemblage de la veilleuse sur le support de pilote et retirer l'ensemble pil ot e.
11. Reassemble the components in reverse order. / Remonter les composants dans l'ordre inverse.
Page 42 of 58
Page 43
5.0 TROUBLE SHOOTIN G

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

piezo ignition button
B. No gas or low gas pressure
turned on
instructions
Weak or improperly located
Thermocouple not installed
Open wire connection in pilot
B. Defective safety circuit
Loose or defective
I. Pilot will not light after
repeated triggering of the
1. Improper ignition 1. Align the electrode with 1/8” (3mm) gap
II. Pilot will not stay lit after
following the lighting
A. No spark at electrode (weak or not heat source for pilot ignition)
to pilot hood
2. Poor connections at starter and ignition electrode
3. Broken ceramic cover on ignition electrode
4. Defective piezo igniter 4. Replace piezo igniter
5. Poor grounding of piezo igniter 5. Tighten mounting nut and/or igniter
1. Gas line shut off(s) may not be
2. Air in gas lines 2. Purge gas lines
3. Gas lines may not be connected
4. Low pressure may be caused by bent line
5. Valve control knob not fully depressed in “PILOT” position
A. Thermocouple / Valve
2. Reconnect if loose
3. Replace pilot assembly
screws
1. Turn on shut-off valves
3. Connect all gas lines
4. Check for a kinked line
5. Fully depress control knob
1. pilot flame

2. Defective thermocouple 2. Replace thermocouple

3. properly
4. circuit

5. Defective Valve 5. Connect the millivolt meter probes to the

Pilot will not stay lit after following the lighting instructions continued …
1. connections
1. Adjust and clean pilot. The flame must impinge on or engulf the thermocouple.
3. Make sure all wire connections at the gas valve terminals are tight and the thermocouple is fully inserted into the mounting bracket
4. Check wire continuity and connections in the pilot circuit
thermopile terminals on the gas valve. Turn the valve to the “PILOT” position, depress, and light. If the meter reading is greater than 540 millivolts after 30 seconds, the thermopile is good. If the pilot does not stay lie, the valve is defective. Check section “B” below, before replacing valve
1. Check continuity, tighten wiring or connections, and repair
Page 43 of 58
Page 44

III. Main burner will not light

A. Valve / Switches
Defective wall switch or
Defective wiring or
Wall switch or thermostat
Thermopile may not be generating sufficient voltage
Wall switch, thermostat, or Vent system is restricted or
V. Flame burns blue and lifts
Insufficient combustion air
1. Incorrect vent or termination
Vent system is restricted or

1. Valve control off 1. Turn to “ON” position

IV. Soot deposits on glass

off burner

VI. Main flame does not burn properly

VII. Flames impinge on firebox top

2. Blockage at the burner (line, orifice, or ports)

3. thermostat
4. connections

5. Excessive length of therm ostat wire from valve to wall switch or thermostat

6. incorrectly wired

7. Defective Valve 7. Turn valve and “ON/OFF” switch to the

8.
(750 mV)
9. wires are defective

1. Air inlet blocked or restricted 1. Clean air inlets

2. inadequate
1. being supplied

2. Manifold pressure set too high 2. Check manifold pressure

3. Vent system restricted 3. Check vent system

used.
1. inadequate

2. Manifold pressure too high 2. Check manifold pressure as required

2. Check and clean
3. Conduct a continuity test or jumper wire test and replace if defective
4. Conduct a test with a jumper wire and repair as required
5. Reduce wire length to less than 100 feet or increase wire size
6. Wire correctly
“ON” position. Check with millivolt meter at terminals TP-TH. Millivolt meter should read greater then 540 millivolts. If the reading is OK and the burner does not come on, replace the gas valve
8. Recheck using the millivolt meter. The pilot flame may not be high enough for the flame to properly engulf the thermopile. If so, adjust and reset. If voltage is still insufficient, replace thermopile
9. Follow previous corrective action, check switch and wiring. Replace where defective
2. Confirm venting & termination are those which are approved with the appliance
1. Ensure that no foreign material blocks air inlets. Ensure the vent is adequate
1. Confirm venting & termination are those
which are approved with the appliance
1. Correct flue as required
Page 44 of 58
Page 45
TROUBLE SHOOTING - INTERMITTENT PILOT

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

pilot
A. No spark at electrode (weak or not heat source for pilot ignition)
ignition electrode
ignition electrode
B. No gas or low gas pressure
turned on
connected
by bent line
instructions
A. Thermocouple / Valve
shown in Figure 27.

2. Defective thermocouple

2. Replace thermocouple
Thermocouple not installed
mounting bracket
Open wire connection in pilot

5. Defective Valve

5. Check with your voltmeter.
B. Defective safety circuit
connections, and repair
A. Valve / Switches
orifice, or ports)
batteries
I. Pilot will not light after repeated triggering of the remote control – intermittent
1. Improper ignition 1. Align the electrode with 1/8” (3mm) gap to
pilot hood
2. Poor connections at starter and
2. Reconnect if loose
3. Broken ceramic cover on
4. Battery power low or dead 4. Replace batteries
5. Gas line shut off(s) may not be
6. Air in gas lines 6. Purge gas lines
7. Gas lines may not be
8. Low pressure may be caused
II. Pilot will not stay lit after following the lighting
1. Weak or im properl y located pi lot
flame
3. properly
3. Replace pilot assembly
5. Turn on shut-off valves
7. Connect all gas lines
8. Check for a kinked line
1. Adjust and clean pilot. The flame must impinge on or engulf the thermocouple, as
3. Make sure all wire connections at the gas valve terminals are tight and the thermocouple is fully inserted into the
4. circuit

1. Loose or defective connections 1. Check continuity, tighten wiring or

III. Main burner will not light

1. Valve control off 1. Turn to “ON” position

2. Blockage at the burner (line,

3. Defective remote 3. Conduct a continuity test or jumper wire

4. Check wire continuity and connections in the pilot circuit
2. Check and clean
test and replace if defective, check
Page 45 of 58
Page 46

5. Defective Valve

5. Contact service technician

III. Soot deposits

1. Air inlet blocked or restricted

1. Clean air inlets
Vent system is restricted or
V. Flame burns blue and lifts
VI. Main flame does not burn
termination
Vent system is restricted or

4. Defective wiring or connections 4. Conduct a test with a jumper wire and

repair as required
off burner
properly

VII. Flames impinge on firebox top

2. inadequate

3. Logs are sooting up 3. Check manual for correct log placement

1. Insufficient c om bustion air be ing supplied

2. Manifold pressure set too high 2. Check manifold pressure

3. Vent system restricted 3. Check vent system

1. Incorrect vent or used.
1. inadequate

2. Manifold pressure too high 2. Check manifold pressure as required

2. Confirm venting & termination are those which are approved with the appliance
1. Ensure that no foreign material blocks air inlets. Ensure the vent is adequate
1. Confirm venting & termination are those which are approved with the appliance
1. Correct flue as required
Page 46 of 58
Page 47
6.0 REPLACEMENT PARTS
When requesting service or replacement parts for your unit, please provide model name and serial number. All parts listed below may be ordered from an authorized dealer. Description Part# Certification Door 726 N/A Burner Left 708L N/A Burner Right 708R N/A Fan IMC1057A CSA / UL Door Glass 745 ASTM C1048 Restrictor 758 N/A Door Glass Gasket 6AL N/A Orifice - NG MP0505-45 N/A Orifice – LP MP0505-56 N/A Propane Conversion Kit LPCKLCF42 CSA C & US Natural Gas Conversion Kit NGCKLCF42 CSA C & US
Intermittent Pilot & R emote Control Valve Parts
Description Part# Pilot Assembly (Intermittent) PSE-NA291 CSA / UL Valve AF-40004 CSA C & US Valve (with step motor inst all ed) AF-4044 CSA C & US Remote Step Motor for AF-4000 Valve AF-4000MOT CSA C & US Supreme Control Module, incl.wire harness AF-4000MOD-S01 CSA C & US Plug-in Adapter ((7.5V A/C & 24” wires) AF-4000ADP24 CSA C & US Battery Back-up AF-4000BBU CSA C & US Extension Module for 120V operation AF-4000120MODS01 CSA C & US Supreme Handheld tra nsmit t er AF-4000HHS01 CSA C & US
Page 47 of 58
Page 48
7.0 SIERRA FLAME’S WARRANTY PROTECTION FOR ALL SIERRA FLAME GAS FIREPLA CE PRODUCTS
Sierra Flame’s products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak tested and test fired at a quality control test station. Once assembled the complete fireplace is thoroughly inspected by a qualified technician, before packaging, to ensure that you, the customer, receives the quality product that you expect from Sierra Flame’s.

SIERRA FLAME’S GAS FIREPLACE’S WARRANTY

Your Sierra Flame gas fireplace is guaranteed to be free of defects in materials and workmanship for a period of 5 years from the date of purchase. This covers: combustion chambers, heat exchangers and burners as well as stainless steel parts against tarnishing. Electrical (110 volt and millivolt) components and wearable parts such as blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, glass (thermal damage only) and pilot assemblies are covered for 1 year and Sierra Flame will provide replacement parts free of charge during the first year of the limited warranty

CONDITIONS AND LIMITATIONS

Sierra Flame warrants its products against manufacturing defects to the original purchaser only – i.e. the individual or legal entity (registered customer) whose name appears on the original invoice – provided that the purchase was made through an authorized Sierra Flame dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives. A licensed, authorized service technician or contractor must have installed the gas fireplace. Installation must
be done in accordance with the installation instructions included with the product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect. Parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasives, chemical cleaners nor any venting components used in the installation of the fireplace.
This warranty does not cover any problems caused to installation used venting or vent terminations which are not certified for use with this product.
Any installation, labor, construction, transportation or other related costs or expenses arising from defective part(s), repair or replacement or otherwise of same, will not be covered by this warranty nor shall Sierra Flame assume responsibility for same. Further, Sierra Flame will not be responsible for any incidental, indirect or consequent damages, except as provided by law, and in no event shall they exceed the original purchase price.
In the first year only, this warranty extends to the repair or replacement of warranted parts, which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the first year, Sierra Flame may, at its discret i on, fully discharge all obligations with respect to this warr ant y by refunding to the original w ar r ant ed purchaser the wholesale price of any warranted but defective parts.
Page 48 of 58
Page 49

CONDITIONS AND LIMITATIONS (continued)

Notwithstanding any provisions contained in this warranty, Sierra Flame’s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of Sierra Flame with respect to the Sierra Flame gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
Sierra Flame neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Sierra Flame will not be responsible for: over firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents, excessive venting configurations, insufficient make up air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of Sierra Flame.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer.
Sierra Flame reserves the right to have its representative inspect any product or part thereof prior to honoring any warranty claim.
7.0 GARANTIE DE PROTECTION
Produits Sierra Flame sont conçus avec des composants et des matériaux de qualité supérieure, as sem blés par des artisans qualifiés qui sont fiers de leur travail. Le brûleur et la valve sont des essais d'étanchéité et d'essai ont tiré sur un poste de contrôle de qualité. Une fois assemblé, chaque foyer est soigneusement inspecté par un technicien qualifié, avant l'emballage, afin de s'assurer que vous, le client reçoit le produit de qualité que vous attendez de Sierra Flame.
FOYER AU GAZ DE SIERRA FLAME - LA GARANTIE
Votre foyer de Sierra Flame est garanti d'être exempt de défauts de matériaux et de fabrication pour une période de 5 ans à compter de la date d'achat. Cette garantie couvre: chambres de combustion, échangeurs de chaleur et brûleurs ainsi que des pièces en acier inoxydable contre le ternissement. Electrique (110 volts et millivolt) et les pièces d'usure comme les souffleuses, les vannes de gaz, capteurs thermiques, interrupteurs, câblages, télécommandes, allumeurs, les joints, le verre (dommage thermique seulement) et les assemblées pilotes sont couverts pendant 1 an et Sierra Flame fournira de remplacement les pièces gratuitement durant la première année de la garantie limitée
Sierra Flame garanti ses produits contre les défauts de fabrication à l'acheteur d'origine seulement - la personne physique ou morale (client inscrit) dont le nom figure sur la f acture d'origine - à condition que l'achat a été effectué auprès d'un revendeur autorisé Sierra Flame et est soumis à les conditions et limitations suivantes.
Cette garantie du fabricant n'est pas transférable et ne peut être prolongé que ce soit par l'un de nos représentants.
Une licence, un technicien de service autorisé ou l'entrepreneur doit avoir installé le foyer à gaz. Installation
CONDITIONS ET LIMITES (SUITE)
Page 49 of 58
Page 50
doit être faite en conformité avec les instructions d'installation incluses avec le produit et toutes les capacités locales et nationales et de prévention des incendies.
Cette garantie limitée ne couvre pas les dommages causés par une mauvaise utilisation, manque d'entretien, accident, des altérations, des abus ou de négligence. Installation de pièces provenant d'autres fabricants annulera cette garantie.
Cette garantie limitée ne couvre pas non plus les égratignures, les bosselures, la corrosion ou la décoloration causés par la chaleur excessive, les abrasifs, de nettoyants chimiques ou tout composant de ventilation utilisé dans l'installation de la cheminée.
Cette garantie ne couvre pas les problèmes causés à l'installation d'aération ou de ventilation utilisé licenciements qui ne sont pas homologués pour une utilisation avec ce produit.
Toute installation, le travail, la construction, le transport ou autres frais connexes ou frais découlant de la pièce défectueuse (s), la réparation ou le remplacement ou non de même, ne seront pas couverts par cette garantie ni Sierra Flame assumer la responsabilité de même. En outre, Sierra Flame ne sera pas responsable des dommages accessoires, indirects ou conséquents, sauf dans les cas prévus par la loi, et en aucun cas, ils dépassent le prix d'achat original.
Dans la première année seulement, cette garantie s'étend à la réparation ou le remplacement des pièces garanties, qui sont des défauts de matériaux ou de fabrication à condition que le produit ait été utilisé conformément aux instructions de fonctionnement et dans des conditions normales.
Après la première année, Sierra Flame, à sa discrétion, se décharger de toutes obligations à l'égard de cette garantie en remboursant à l'acheteur d'origine le prix de gros de toute pièce garantie qui est défectueuse (s).
Nonobstant toutes dispositions contenues dans la présente garantie, Sierra Flame responsabilité en vertu de cette garantie est définie comme ci-dessus et il ne doit en aucun cas s'étendre à des dommages indirects, accessoires ou indirects.
Cette garantie définit les obligations et la responsabilité de Sierra Flame à l'égard de Sierra Flame et toute autre garantie expresse ou implicite à l'égard de ce produit, ses composants ou accessoires est exclue.
Sierra Flame n'assume, ni n'autorise aucun tiers à assumer en son nom, toute autre responsabilité à l'égard de la vente de ce produit. Sierra Flame ne sera pas responsable d 'une surchauffe, des refoulements, des déversements causés par les conditions environnementales telles que des toits, des bâtiments, des arbres à proximité, des collines, des montagnes, des évents inadéquats, des configurations de ventilation excessive, l'insuffisance des pressions d'aire d'appoint, ou négatives qui peuvent ou peut ne pas être causés par des systèmes mécaniques tels que les ventilateurs, fours, les sécheuses, etc.
Les dommages à la cheminée, chambre de combustion, ou pièce d'habillage d'autres à cause de l'eau, causés par des intempéries, de longues périodes d'humidité, la condensation, des produits chimiques ou de nettoyants dommageables ne sera pas la responsabilité de Sierra Flame.
L'acte de vente ou sa copie sera requise ainsi que le numéro de série et un numéro de modèle lors de toute réclamation auprès de votre revendeur agréé.
Sierra Flame se réserve le droit d'avoir son représentant d'inspecter tout produit ou pièce avant d'honorer toute réclamation.
Page 50 of 58
Page 51

8.0 LABEL INFORMATION

Page 51 of 58
Page 52
8.0 LABEL INFO RMATION (continued)

WARNING

equipped with a three prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or
électrique et doit être br anc hé dir ec te me nt dans une prise à trois bro ches réci pient. Ne pas couper ou
This appliance must be properly connected to a
This is a direct vent appliance.

Electrical Grounding Instructions

This appliance is remove the grounding prong from this plug.
AVERTISSEMENT
Instructions à la terre électrique
Cet appareil est équipé d'un à trois broches (terre) pour votre protection contre les risques de choc
retirer la broche de terre de cette fiche.
venting system in accordance with the
manufacturer’s installation instructions.
Page 52 of 58
Page 53

APPENDIX A (AMERICAN FLAME VALVE INFORMATION)

Page 53 of 58
Page 54

APPENDIX A (Continued)

Page 54 of 58
Page 55
Special Features on the AF-4000 System
module that reads “Continuous Pilot ON/OFF”,
c) When the Continuous Pilot switch is in the ON position and the appliance ON/OFF switch is turned
APPENDIX A (Continued)
The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0 volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” female terminals from the adapter to the two 1/4” male terminals, located on the AF-4000 Module , marke d POWER. The second method of powering the appliance is by using the AF-4000 BP battery pack.
The appliance will not have back up power, during power outages, if only the 6.0 volt adapter is used however a battery back up package, AF-4000BBU, is available to be used in this situation.
The AF-4000 module has 2 special features built into the system. Please check with local City codes regarding the use of the following feature.
1. Continuous Pilot Feature - This featur e allows the user to change from a spark to pilot system to a standing pilot system, for direct vent appliances during cold climate, to keep the firebox warm. a) There is a switch located on the side of the AF-4000 this switch will allow the user to select the pilot mode of operation. b) When the Continuous Pilot switch is in the OFF position and the appliance ON/OFF switch is turned to ON the pilot will spark and light. When the appliance ON/OFF switch is turned OFF the pilot will shut off when the main burner shuts off.
on the pilot will spark and light. When the appliance ON/OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off. This setting is generally used in cold climates to keep the firebox warm. d) The Continuous Pilot mode can also be activated by an optional hand held remote control.
2. Remote Control Feature - The AF-4000 module has a built in remote control receiver. This allows the user to program a hand held remote transmitter, wireless wall mount thermostat or wireless wall mount switch to the appliance at any time during or after the installation of the appliance. a) There is a switch located on the side of the AF-4000 module that reads REMOTE/OFF. b) When the Remote/Off switch is in the OFF position the appliance will operate from an appliance mounted rocker switch or wall switch connected to the (2) brown wires on the AF-4000 module. c) When the Remote/Off switch is in the REMOTE position the appliance will operate from the Remote Control transmitter, wireless wall mounted thermostat or wireless wall mounted switch.
NOTE: The AF-4000 module must be programmed to the Remote Control transmitter, wireless wall mounted thermostat or wireless wall mounted switch.
a) To program the AF-4000 locate the LEARN button on the AF-4000 module. Press and releas e the LEARN button, the AF-4000 module will beep then press any key on the Remote Control. Once the AF-4000 internal receiver accepts the transmitter code there will be a series of confirming beeps. b) The Remote system is now ready for use.
Page 55 of 58
Page 56
APPENDIX A (Continued)
AF-4000 Wiring Diagram

APPENDIX B (NG – LP CONVERSION KITS)

This kit will convert the fireplace to Natural Gas / Propane (as applicable). / Ce kit vous permet de convertir la cheminée au gaz naturel / propane (le cas échéant).
The Elite models are designed to burn either natural gas or propane. Each unit leaves the factory equipped for one specific fuel but it is simple to field convert the unit to an alternate fuel. The original type of fuel is marked on the ratings label of the manual. / Les modèles Elite sont conçus pour brûler du gaz naturel ou au propane. Chaque unité quitte l'usine équipée pour un combustible spécifique, mais il est simple de convertir aligner l'appareil à un carburant de remplacement. Le type d'origine de carburant est marqué sur l'étiquette signalétique du manuel.
Page 56 of 58
Page 57
WARNING
AVERTISSEMENT
THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE OF THE AUTHORITY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT
WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS
FOLLOWED EXACTLY, A FIRE , EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE QU ALIFIED SERVI CE
AGENCY IS RESPONSIBLE FOR THE PROPER INSTALLATION OF THIS KIT. THE INSTALLATION IS
NOT PROPER AND COMPLETE UNTIL THE OPER ATION OF THE CONVER TED FI REPLACES IS
CHECKED AS SPECIFIED IN THE MANUFACTURER’S INSTRUCTIONS SUPPLIED WITH THE KIT.
Ce kit de conversion doit être installé par un technicien qualifié CONFORMEMENT AUX
INSTRUCTIONS DU FABRICANT et tous les codes et exigences de la l'autorité compétente.
Si l'information dans ces instructions n'est pas suivie exactement, UN INCENDIE, EXPLOSION OU
PRODUCTION DE MONOXYDE DE CARBONE PEUT causer des dommages matériels, DES
BLESSURES OU PERTES DE VIE. L'Agence des services qualifié est responsable de la bonne
installation de ce kit. L'INSTALLATION N'EST PAS BON ET COMPLET jusqu'à l'opération des
cheminées converti soit vérifié selon les instructions de du fabricant fournies avec le kit.

Conversion Kit Contents / Contenu du kit de conversion

This conversion kit contains the following parts: Ce kit de conversion contient les éléments suivants:
1) Pilot orifice / orif i c e de la veilleuse 2) Burner orifice / orifice du brûleur
3) Fuel conversion label The proper steps for converting the appliance are as follows: / Les mesures adéquates pour converti r
l'appareil sont les sui va ntes:
1) CAUTION: The gas supply shall be shut off prior to disconnecting the electrical po wer, before proceeding with the conversion. / ATTENTION : l'alimentation en gaz doit être coupée avant de débrancher l'alim entation électrique, avant de procéder à la conversion.
2) Remove the door, rock & glass kit and burner. / Retirez les portes, pierres et kit de verre et le brûleur.
3) Change the burner & pilot orifices with the orifice supplied by the manufacturer for propane or natural gas / Changer le brûleur et les or ifices pilotes avec l'orifice four ni par l e fabricant pour le propane ou le gaz naturel
4) Convert the gas valve by turning to either Nat or LP (see diagrams next page)./ Convertir le robinet de gaz en tournant soit Nat ou LP (voir schémas page suivante).
5) Adjust air shutter [NG 3/8" (9.525mm) LP Fully Open] (see sec tion 3.3.9) / Réglez l'obturateur d'air [NG 3/8" (9.525mm) LP ouvrir complètement] (voir la section 3.3.9)
6) Replace burner, rock and glass kit and door. / Remplacez le brûleur, kit de pierre et de verre et de la porte.
7) Leak test the appliance, with a soapy water solution, prior to plac ing the unit into operation. / Fuite de tester l'appareil, avec une solution d'eau savonneuse, a vant de placer l'appareil en marche.
8). Fill out the fuel conversion at the bottom of the rating label. Then c omplete the fuel conversion installation on page 59. / R emplir la conversion du carburant au bas de la note label.Then terminer l'installation de convers ion du combustible à la page 59.
9) Light appliance. See the Light i ng Instructions, section 2.0 OPERATION, of the manual to verify normal operating sequence of the ignition system. / Appareil léger. Voir les instructions d 'allumage, la section 2.0 FONCTIONNEMENT, du manuel afin de vérifier la séquence de fonct ionnement normal du système d'allumage.
All valves have been pre-set and certified f or installation at elevations from 0 – 2000 feet (1 – 608 m) above sea level. / Toutes les vannes ont ét é pr é-réglé et c ertifié pour l'installat ion à des alt it udes allant de 0 - 2000 pieds (1 à 608 m) au-des s us du niveau des mers.
Page 57 of 58
Page 58
CONVERSION INSTALLATION / INSTALLATION DE CONVERSION
This appliance was converted on DATE :_______________________________________ from NG / LP to LP / NG
BY _____________________________________________________________________________________________
with the conversion kit NGCKLCF55 or LPCKLCF55 as clearly marked on the bottom of the manufacturer’s label plate by the above named qualified service agency/technician which accepts the responsibility that the conversion has been completed properly as per instructions in this manual. Cet appareil a été converti sur DATE: _______________________________________ partir de NG / LP pour LP / NG
PAR____________________________________________________________________________________________
avec le kit de conversion NGCKLCF55 ou LPCKLCF55 aussi clairement marqué sur le bas de la plaque l'étiquette du fabricant par le agence de service qualifié ci-dessus nommé / technicien qui accepte la responsabilité que la conversion a été dûment remplie selon les instructions contenues dans ce manuel.
Sierra Flame #1503-7088 18th Ave., Burnaby, BC V3N 0A2
Canada
Page 58 of 58