IF THE INFORMATION IN THESE INS T RUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS:
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
INSTALLER: Leave this manual with the appl iance.
CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
REFERENCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF
INSTALLED.
15,500 BTU
Natural Gas
Installation and Operating Instructions
MODELS: LANGLEY-36-NG, LANGLEY-36-NG-EI
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in your building
• Immediately call your gas supplier from a neighbour’s phone. Follow gas supplier’s
instructions
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
BURNS FROM THE HOT VIEWING GLASS IS
PROVIDED WITH THIS APPLIANCE AND SHALL BE
Page 1 of 51
Page 2
CLIENT # LC773211
THE LANGLEY
AVERTISSEMENT
ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE
TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquids inflammables dans le
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
L'installation et l'entretien doivent être assurés par un installateur ou un service d'entretien
AVERTISSEMENT: Une mauvaise installation, de réglage, la modification, de services ou de
INSTALLATEUR : Laissez cette notice avec
S'IL VOUS PLAIT LIRE CE MANU EL AVANT
BARRIÈRE conçu pour réduire le risque de brûlures et
APPAREIL ET DOIT SE.
AVERTISSEMENT
Une surface vitrée chaude
Laisser refroidir la surface
15,500 BTU
Manuel D’installation et Guide de l’utilisateur
MODELS: LANGLEY-36-NG, LANGLEY-36-NG-EI
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER
voisinage de cet appareil ou de tout autre appareil.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le
bâtiment où vous vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
GAZ NATUREL
qualifié ou par le fournisseur de gaz.
maintenance peut causer des dommages corporels ou matériels. Reportez-vous à ce manuel.
Pour toute assistance ou information supplémentaire, consulte r un i nstallateur qualifié, un
service ou le fournisseur de gaz.
l’appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
D'INSTALLER OU UTILISER CET
APPAREIL. CONSERVEZ CE MANUEL
à la consultation verre chaud EST FOURNI AVEC CET
POUR REFERENCE FUTURE.
peut causer des brûlures.
vitrée avant d’y toucher
Ne permettez jamais à un
enfant de toucher la
surface vitrée.
Page 2 of 51
Page 3
Table of Contents
IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 5
8.0 LABEL INFORMATION .………………………………………………………………….…46 - 47
APPENDIX A (INTERMITTENT PILOT & VALVE KIT)……………………....………………….48 - 51
Page 3 of 51
Page 4
WARNING
• Read this owner’s manual carefully and completely before trying to assemble, operate or
service this fireplace. Follow instructions for proper installation
explosions, electrical shock and carbon monoxide poisoning.
AVERTISSEMENT
• Lisez ce manuel attentivement et complètement avant d'essayer de monter, utiliser ou entretenir
carbone.
D
MANUFACTURER’SBARRIERFORTHISAPPLIANCE
EN RAISON DE TEMPERATURES ELEVEES, L'APPAREIL DOIT ETRE PLACE HORS DE LA CIRCULATION ET LOIN DES
• Failure to install this appliance per the manufacturer’s instructions or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury. Any
change to this fireplace or its controls can be dangerous.
• Improper installation or use of this fireplace can cause serious injury or death from fire, burns,
ce foyer. Suire les instructions pour assurer une bonne installation.
• Risque de dommages ou de blessures si l’appareil n’est pas installé selon les instructions du
fabricant ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont
utilisées. Tout changement à ce foyer ou à ses contrôles peuvent être dangereux.
• Une mauvaise installation ou l'utilisation de cette cheminée peut causer des blessures graves
ou la mort par le feu, les brûlures, explosions, de chocs électriques et intoxication au monoxyde de
UE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
C
HILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR C LOTHING IGNITION.
Y
OUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
C
LOTHING OR OTHER FLAMMABLE MAT ERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE M ATERIALS,GASOLINE,AND OTHER FLAMMABLE
NFANTS ET ADULTES DOIVENT ETRE AVERTIS DES DANGERS DE LA TEMPERATURE DE SURFACE ELEVEE ET
DEVRAIT RESTER A L
'ECART POUR EVITER LES BRULURES OU L'INFLAMMATION DES VETEMENTS.
L
ES JEUNES ENFANTS DOIVENT ETRE SOIGNEUSEMENT SURVEILLES QUAND ILS SONT DANS LA MEME PIECE QUE
L
CLOTHING OR OTHER MATERIAUX COMBUSTIBLES NE DOIVENT PAS ETRE PLACES SUR OU PRES DE L'APPAREIL.
'APPAREIL.
GARDER
LAZONE SALLE CLAIRE ET LIBRE DE MATERIAUX COMBUSTIBLES, D'ESSENCE, ET AUTRES VAPEURS ET
LIQUIDES
SI LA BARRIÈRE EST ENDOMMAGÈE, LA BARRIÈRE DOIT ÈTRE REMPLACÈE PAR LA BARRIÈRE
DE LA FABRICANT DE CET APPAREIL
Page 4 of 51
Page 5
WARNING
AVERTISSEMENT
Do not use this appliance if any part has
been under water. Immediately call a
has been under water.
Ne pas utiliser cet appareil s’il a été plongé,
plongée dans l’eau.
Toddlers, young children and others may be
Les tout-petits, les jeunes enfants et d'autres
les jeunes enfants et les personnes à risque de
propres.
This fireplace is a vented product. This
Ce foyer est un produit ventilé. Ce foyer doit
Caution: Label all wires prior to
Attention : Au moment de l’entretien des
inadéquate et dangereu x.
Verify proper operation after servicing
S’assurer que l’appareil fonctionne
adéquatement une fois l’entretien terminé
If appliance is installed directly on carpeting,
Si l'appareil est installé directement sur un
largeur et la profondeur de la cheminée.
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
meme partiellement, dans l’eau. Appeler un
technician qualifié pour inspecter l’appareil et
remplacer toute partie du système de
commande et toute commande qui a été
susceptible to accidental contact burns. A
physical barrier is recommended if there are
at risk individuals in the house. To restrict
access to a fireplace or stove install an
adjustable safety gate to keep toddlers,
young children and at risk individuals out of
the room and away from hot surfaces.
Any safety screen or guard removed for
servicing an appliance must be replaced
prior to operating the appliance.
Installation and repair should be done by a
qualified service person. The appliance
should be inspected before use and at least
annually by a professional service person.
More frequent cleaning may be required due
to excessive lint from carpeting, bedding
material, et cetera. It is imperative that
control compartments, burners and
circulating air passageways of the appliance
be kept clean.
peuvent être sensibles aux brûlures par
contact accidentel. Une barrière physique est
recommandé s'il ya des personnes à risque
dans la maison. Pour restreindre l'accès à une
cheminée ou un poêle installer une barrière de
sécurité réglable pour garder les tout-petits,
la salle et à l'écart des surfaces chaudes.
Tout écran ou grille de protection pour
l'entretien d'un appareil doit être remplacé
avant de faire fonctionner l'appareil.
Installation et réparation doit être effectuée par
un technicien qualifié. L'appareil doit être
inspecté avant son utilisation et au moins
annuellement par un technicien qualifié. Un
nettoyage plus fréquent peut être nécessaire
en raison de peluches provenant des tapis,
literie, etc. Il est impératif que les
compartiments de contrôle, les brûleurs et les
conduits d'air de l'appareil soient gardés
fireplace must be properly installed by a
qualified service person. The glass door
must be properly seated and sealed. If this
unit is not properly installed by a qualified
service person with the glass door properly
seated and sealed gas leakage can occur.
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
vinyl tile or other combustible material other
than wood flooring, the appliance shall be
installed on a metal or wood panel extending
the full width and depth of the fireplace.
être correctement installé par un technicien
qualifié. La porte en verre doivent être placés
correctement et scellé. Si cet appareil n'est
pas correctement installé par un technicien
qualifié avec la porte en verre bien en place et
des fuites de gaz scellés peuvent se produire.
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de câblage
peuvent entraîner un fonctionnement
tapis, carreaux de vinyle ou autre matériau
combustible autre qu'un plancher de bois,
l'appareil doit être installé sur un panneau de
métal ou de bois se prolongeant sur toute la
Page 5 of 51
Page 6
1.0 INTRODUCTI ON
ITEM
NAT URAL G AS (NG)
INPUT: Hi
15,500 Btu/hr (4.54 kW)
INPUT: Lo
11,000 Btu/hr (3.22 kW)
COLLECTEUR DE PRESSION: FORT
FAIBLE
ENTREE DE PRESSION
Minimum: 5.0” w.c. (1.2 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
FORMAT D'ORIFICE:
VOLET DE L’AIR
(3.175mm)
TYPE DE SOUPAPE
Apex Control B081
ÉVACUATION
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
1.1 SPECIFICATIONS
TABLE 1
MANIFOLD PRESSURE: Hi
MANIFOLD PRESSURE: Lo
COLLECTEUR DE PRESSION:
GAS INLET SUPPLY PRESSURE:
ORIFICE SIZE: @ 0-4500’
AIR SHUTTER
CONTROL VALVE TYPE:
VENTING
3.5” w.c. (0.87 kPa)
1.7” w.c. (0.42 kPa)
# 48 DMS
OPEN 1/8”min
Skytech AF-40004
2-ply aluminum vent
Page 6 of 51
Page 7
APPLIANCE DIMENSIONS
8.75”
1.00”
0.50”
34.20”
39.19”
34.74”
22.64”
17.37”
27.92”
32.38”
10.28”
INSTALLATION CODES
This appliance is a Direct Vent applianc e which draws all c om bus t ion air from out s ide the building throug h an intake vent pipe.
Installa tion must conform to local codes. In the absence o f local codes, i nstallation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1. The unit, when inst al led ,
must be elect ric ally grounde d in acc ordanc e wit h local codes or, in t he abs enc e of lo cal codes , wit h the Nati onal El ectri c Code ANSI/ NFPA No.70 or with the curr ent Canadian Electri cal CodeCS A C22.1. In the st ate of Massac husetts, this produc t can
only be installed by a licensed plumber or a licensed gas fitter. Failure to comply will void the warranty.
This appliance has been certified for use with natural gas.
This appliance is not for use with solid fuels.
CODES D'INSTALLATION
Cet appareil est un appareil à évent direct, qui attire tous l'air de combustion provenant de l'extérieur du bâtiment par une
entrée d'évent.
L'install ation doit se confo rmer aux cod es locaux. En l'abs ence de codes locaux, l 'installat ion doit être confo rme au National Fuel Gas Code A NSI Z223. 1/NFPA 5 4, ou le g az natu rel actuel et le Code d' install ation du propan e CSA B149.1. L'uni té, une
fois installé, doit être électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, avec le
National Electric Code ANSI / NFPA No.70 ou avec l'actuel Codecanadien de l'électricité CSA C22.1
Cet appareil a été certifié pour une utilisation avec du gaz naturel.
Cet appareil n'est pas pour une utilisation avec des combustibles solides.
Page 7 of 51
Page 8
1.2 FEATURES
Ignition system:
Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Gas control: * Optio nal*
Gas control valve type:
Automatic millivolt powered combination gas control valve with variable flame control for
convenience and on/off switch. Optional digital remote on/off wall switch and/or optional wall
thermostat (note: thermostats are not allowed in the United States). The gas valve does not
require electricity from an external source.
Electronic Valve: * Optional *
Automatic DC valve with AC power adapter. Hand held remote control.
Supreme Remote Control
Functional Operation Matrix
Initial Setup
Installation of (2) AAA-size batteries will activate the setup mode. Setup mode can
also be activated by pressing the FLAME REAR and PROG/TI ME but tons
simultaneously for 5 s econds. The control will exit setup mode if no button is pressed
for 20 seconds. Appropriate icon on LCD will flash when rea dy for setup.
Press the UP or Down button in set up mode to change the temperat ure scale. Press
SET button to skip or advance to Fuel Type setup.
Press the UP or DOWN button t o s witc h c ontrol from Natural to LP, or LP to Natural Gas. Press SET
button to skip or advance t o Cl oc k setup.
Press the UP or Down Button t o s et the hour. Press SET to advance to mi nutes.
Press the UP or Down button to s et minutes. Press SET to advance to AM or PM.
Press the UP or Down button to s et AM or PM. Press the SET button to advance to t he day of week.
Use UP or Down button to select the day of the week.
The control will exit setup mode in 20 seconds.
MODE Button
The MODE button cycles the unit through the basic operational modes.
When off, press and release the MODE button to turn the unit on in Manual mode.
Press and release the MODE button again, and the unit will operate in the Thermostat m ode.
Press and release the MODE button again, and the unit will tur n off.
Program Mode
The Program function is controlled by the PROG/TIME button. The control may be programmed for up to
two settings for weekdays and two settings for weekends. The control is preset to fac tory settings.
When the Program Mode is activated, the unit will automatically be operating in the T hermostat Mode.
The unit will turn on or off bas ed upon room and set temperature.
To activate the Program mode, press and release the PROG/TIME button.
To change the settings for t he Program mode, press and hold the PROG/TIME button for 5 seconds. The
program feature will flash at the top of the screen.
Press the UP or DOWN button t o c hange the setting of the weekday (MTWTF) P1 ON. Press and release
the SET button.
Page 8 of 51
Page 9
Press the UP or DOWN button t o c hange the setting of P1 OFF. Press and release the SET button.
Press the UP or DOWN button t o c hange the setting of P2 ON. Press and rele as e the SET button.
Press the UP or DOWN button t o c hange the setting of P2 OFF. Press and release the SET button.
Press the UP or DOWN button t o c hange the setting of the weekend ( S S) P1 ON. Press and release the
SET button.
Press the UP or DOWN button t o c hange the setting of P1 OFF. Press and release the SET button.
Press the UP or DOWN button t o c hange the setting of P2 ON. Press and rele as e the SET button.
Press the UP or DOWN button t o c hange the setting of P2 OFF. Press and release the SET button.
The Program Mode has been re-programmed.
Countdown Timer
The Countdown Timer Mode all ows the control to operate the unit for up to 3 hours, in 10-minute
increments. It can be operated in eit her the Manual or Thermostat Modes.
To enter Timer Mode, press and release the TIMER button. The Timer icon will flash.
Press the UP or DOWN button t o s et the running time, in 10-minute increments. Press and releas e the
SET button. The timer will run for the set time duration.
Pressing the TIMER button while in Timer Mode will terminate the Timer operation. The Timer operation
will also terminate if the MODE button is cycled to off.
Thermostat Mode
The unit is placed in Thermostat Mode using the MODE button. Placing the unit in Thermostat Mode will
activate the numbers in the smaller window on the LCD screen.
Press the UP or DOWN button t o c hange the thermostat set tem per ature. When the desired set
temperature appears, pres s and release the SET button to set.
If the SET button is not pressed, the set temperature will automatically be set after 5 seconds.
The Thermostat Mode can be de-activated by pressing the MODE button.
Thermostatic Flame Modulation
This control can perform Main Flam e Modulat ion using the Thermostat. The control will shut the unit off
when the room temperature reaches 2° above set temperature. The Thermostat will automatically
modulate the main flame:
Manual Flame Modulation – Main Flame
To change the Flame Level manually, press the FLAME MAIN button. The current level will show in the
MAIN box on the LCD screen.
Press the UP or DOWN button t o c hange the Flame Level.
When the unit is turned on, whether in Manual, Thermostatic, or Program Mode, the Main Flame will
automatically ignite at the High (7) setting. After 5 seconds , the flame will default t o the previous setting.
Fan Control (Not applicable on this model)
The unit must be ON to operate the Fan.
The Fan will turn on after 5 minutes of operation. Once t he Fan c omes on, it can be controlled using t he
FAN button.
Press the FAN button, and the fan icon and speed will appear on the LCD s c reen.
Press the UP or DOWN button t o c ontrol the fan speed (0-6). Press the DOWN button until 0 Level is
reached to turn the Fan off.
The fan will run for 12 minut es after the unit is shut off in any mode. The fan may not be controlled during
this period.
Page 9 of 51
Page 10
Continuous Pilot
The unit can be changed from Intermittent Pilot Ignition (I P I), to Continuous, or standing, pilot.
To place the unit in continuous pilot mode, press and release the PROG/TIME and the FLAME MAIN
buttons simultaneously
. Continuous Pilot will appear on the LCD screen.
Repeat the simultaneous PROG/TIME and FLAME MAIN push to place the unit back in IPI mode.
This feature can also be activated by the Continuous Pilot ( On/Off) switch on the Main Modul e.
Child Lock-Out
The Child Lock-out feature c an be ac tivated by pressing the PRO G/Time and UP buttons simultaneously.
CP will appear on the LCD screen, and no signals can be sent from the transmitter.
To take the control out of C hild Lock-out mode, repeat the above step. CP will disapper from the screen.
Learn Function
To program the system to a tr ansmitter, press the LEARN button on t he Main Module. A single audible
beep will be heard.
Press the MODE button on the transmitter to learn the transmitter to the system. A series of beeps will be
heard.
Up to two additional (NO N -THERMOSTATIC) transmitters can be used simultaneously. To learn
additional transm i tt er s, press and release the learn button again, and press the on button on the additional
transmitters.
To clear all transmitters and start over, press and hold the LE ARN button for 10 seconds. A series of
three beeps will be heard, and the system is clear.
Low Battery Indicator
A low battery icon will appear on LCD screen when transmitter batteries reach low voltage level.
Thermal Safety
When the internal com ponents of the Main Module reach 170°F, the unit will automati c all y shut off, and
send a repetitive audibl e signal. The unit can be turned back on when the module cools belo w 160°
Communication Safety
When in the Thermostat or P rogram Mode, the transmitt er will send a silent signal to the module every 15
minutes. If a signal is not received within 2 hours due to dead batteries, lost transmitter, or transm itt er out
of range, the unit will automatically shut down, and the module will send a repetitive audible signal.
1.3 INTENDED USE / US AGE PROPOSÉ
This appliance is intend ed to be use d as a zero c leara nce fireplace . This unit is certif ied for install ation in a bedroom or a
bed sitting room or a bathroom where the maximum input is with in 50 cu bic f eet per 1000 Btu/hr, ( i.e. 900 c ubic feet f or E
unit & 1600 cubic feet for H unit). In Canada all bedroom installations require the use of wall thermostats (note:
thermostats are not allowed in the United States).
Cet appareil est destiné à êtr e utilisé comme un foyer à dégagem ent zéro. Cet appareil est cer tifié pour une installation
dans une chambre ou une cham bre à coucher ou une salle de bain ass is où l'entrée m aximale est de moins de 50 pieds
cubes par 1000 Btu / h (i.e. 900 cubic f eet for E unit & 1600 cubic feet for H unit). In Cana da all bedroom installat ions
require the use of wall thermostats (note: thermostats are not allowed in the United States).
Page 10 of 51
Page 11
1.4 GENERAL SAFETY / SÉCURITÉ GÉNÉRALE
• Maintain adequate clearances around air openings into the combustion chamber.
• Respecter les distances minimales convenables autour des bouches d'air dans la chambre de combustion.
• Maintain adequate accessibility clearances for servicing and proper operation.
• Respecter les distances minimales d'accessibilité suffisante pour l'entretien et bon.
• This appliance shall not be connected to chimney flue serving a separate solid-fuel burning appliance.
• Cet appareil ne doit pas être raccor dé à une cheminée desservant un autre appareil brûlant des combustibles
solides.
•The appliance area m us t be k ept cle ar an d free f rom com bustible m ater ials, gas oline and ot her f lamm able liquids
and vapors.
•La zone appareil doit rester clair et exempt de matériaux combustibles, essence et autres vapeurs et liquides
inflammables.
• The flow of combustion and ventilation air shall not be obstructed.
• Le débit de combustion et de ventilation ne doit pas être obstrué.
• The combustion air suppl y shall be in the same pressure zone as the drafthood r elief opening on an appliance
equipped with a drafthood or as the vent outlet on an appliance not equipped with a drafthood.
•L'alimentation en air de co mbustion doit être dans l a zone même pres sion que l'ouverture de sec ours hotte à air
sur un appareil équipé d'une hotte à air ou que l'évent de sortie sur un appareil n'est pas équipé d'une hotte à air.
•Do not use this appliance if an y part has been under water. Imm ediately call a qualified service technician to
inspect the appliance and to r eplace any part of the control system and any ga s control which has been under
water.
•Ne pas se servir de cet appar eil s’i l a été plong é dans l’eau, même partiellem ent. F aire inspec ter l’app arei l par un
technicien qualifié et r emplacer toute partie du s ystèm e de c ontr ô le et tou te c om mande qui ont été plongée s dans
l’eau.
Page 11 of 51
Page 12
IMPORTANT
PLEASE READ THE FOLLOWING CAREFULLY
It is normal for fi replaces fabricat ed of steel t o give off some e xpansio n and/or cont raction noi ses
during the start up or cool down cycle.
It is recommended that you burn your fireplace for at least 4 (fou r) hours the first time you use it.
IMPORTANT
S'IL VOUS PLAÎT LIRE ATTENTIVEMENT CE QUI SUIT
Il est normal pour les foyers fabriqués d'acier à dégager une certaine expansion et / ou des bruits
fois que vous l'utilisez .
WARNING
Hot while in operation. Do Not Touch. Severe burns may result. Keep children, clothing,
of the appliance be kept clean.
AVERTISSEMENT
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appar eil. Risque de brûlures
d'air de l'appareil soient gardés propres.
It is not unusu al for gas fireplaces to give o ff some odors the first time the y are burned. This is
due to the oils and sealants in the manufacturing process.
PLEASE ENSURE YOU ROOM IS WELL VENTILATED DURING BURN OFF – OPEN ALL WINDOWS
de contraction pendant le démarrage ou cycle de refroidi ssement.
Il n'est pas inhabitu el po ur les foyers à gaz de dégager certain es odeurs la première fois qu'ils
sont brûlés. Cela est dû aux huiles et produits d'étanchéité dans le processus de fabri cat ion.
S'IL VOUS PLAÎT VOUS ASSURER pièce est bien aérée pendant BRÛLER - Ouvrir toutes les
fenêtres
Il est recommandé que vous brûlez votre foyer pendant au moins 4 (quatre) heures la première
furniture, gasoline and other liquids having flammable vapors aw ay.
Toddlers, young children and others may be susceptible to accidental contact burns. A
physical barrier is recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove install an adjustable safety gate to keep toddlers , young
children and at risk individuals out of the room and away from hot surfaces.
Any safety screen or guard removed for servicing an appliance must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The applia nce should
be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material, et
cetera. It is imperative that control compartments, burners and circulating air passageways
graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres
liquides produisant des vapeur inflammables loin de l’appareil.
Les tout-petits, les jeunes enfants et d'autres peuvent être sensibles aux brûlures par
contact accidentel. Une barrière physique est recommandé s'il ya des personn es à risq u e
dans la maison. Pour restreindre l'accès à une cheminée ou un poêle installer une barrière
de sécurité réglable pour garder les tout-petits, les jeunes enfants et les personnes à risque
de la salle et à l'écart des surfaces chaudes.
Tout écran ou grille de protection pour l'entretien d'un appareil doit être rem placé avant de
faire fonctionner l'appareil.
Installation et réparation doit être effectuée par un technicien qualifié. L'appareil doit être
inspecté avant son utilisation et au moins annuellement par un technicien qualifié. Un
nettoyage plus fréquent peut être nécessaire en raison de peluches provenant des tapis,
literie, etc. Il est impératif que les compartiments de contrôle, les brûleurs et les conduits
Page 12 of 51
Page 13
2.0 OPERATION
1. Pressure Taps
10. Inlet Ports
2.1 LIGHTING INSTRUCTIONS - f or Int e rmittent Pilot
FORYOURSAFETY,READBEFORELIGHTING
WARNING: If you do not follow these instr u ctions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. Do not attempt to light the pilot by hand.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety
information above on this label. If you don’t smell gas, go to the next step.
6. Turn on all electric power to the appliance.
7. Set thermostat to desired setting (or switch to "ON" if not using a thermostat).
8. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
TO TURN GAS OFF TO APPLIANCE
1.Set thermostat to lowest setting.
2.Turn on/off switch to off.
2. Main Valve Connection
3. Pilot Internal Solenoid Connection
4. Outlet Ports
5. Mounting Holes
7. Flow Control Screw
8. Pilot Connections
9. High/Low Connection
Page 13 of 51
Page 14
2.1 INSTRUCTIONS D' ALLUMAGE - Pilote intermittent
1. Prises de pression
10. Ports d'entrée
POURPLUSDESÉCURITÉ,LIREAVANTD’ALLUMER
AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué
de déclencher un incendie ou une explosion entraînant des domma g es, des blessures ou la mort.
A. Cet appareil est équipé d'un dispositif d'allumage qui allume automatiquement le pilote. Ne pas tenter d'allumer le pilot e à la main.
B. Avant d’allumer la veilleuse, reniflez tout autour de l’appareil pour décel eur une odeur de gaz. Reniflez près du plancher, car certains gaz sont
plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous server des telephones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoinder le fournisseur, appelez le service des incendies.
C. Ne pousser ou tourner la manette d’admission do gaz qu’à la main. Ne jamais employer d’outil à cette fin. Si la manette reste coincée, ne tentez
Pas de la réparer; appelez un technici an qualifié. Quic onque tente de forc er l a manette ou de la réparer peut provoquer une explosion ou un
incendie.
D. N’utilisez pas cet appareil s’il a été plunge dans l’eau, meme partiellement. Faites inspecter l’appareil par un technician qualifié et remplacez toute
partie du système de contrôle et toute c ommande qui ont été plongés dans l’eau.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ! Lisez les inst ruct i ons de sécurité sur la portio n supérieure de cette etiquette.
2. Réglez le thermostat à la temperature la plus basse.
3. Coupez l’alimentation électrique de l’appareil.
4. Ne tentez pas d'allumer le pilote à la main.
5. Attendre cinq (5) minutes** pour laisser échapper tout le gaz. Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler une
odeur de gaz, Si vous sentez une odeur de gaz, ARRÉTEZ! Passez à l’étape B des instructions de sécurité sur la portion supérieure (à gauche) de cette etiquette. S’i l n’y a
pas d’odeur de gaz, passez à l’étape suivante.
7. Mettez l’appareil sous tension.
8. Réglez le thermostat à la temperàture désirée.
9. Si l'appareil ne fonctionne pas, suivez les instructions "Pour couper le gaz à l'appareil" et appelez votre technicien ou votre fournisseur de gaz
COMMENT COUPER L’ADMISSION DE GAZ
L’APPAREIL
1.Réglez le thermostat à la temperature la plus basse
2.Active r / OFF sur OF F.
2. Raccordement de la vanne principale
3. Pilote de connexion interne solénoïde
4. Ports de sortie
5. Trous de montage
7. Vis de réglage du débit
8. Connexions pilote
9. High/Low Connection
Page 14 of 51
Page 15
2.1 LIGHTING INSTRUCTIONS – for Standing Pilot
FORYOURSAFETY,READBEFORELIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. Controls are accessed by opening the bottom louver.
5. Push in gas control knob slightly and turn clockwise to “OFF”.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety
information above on this label. If you don’t smell gas, go to the next step.
7. Turn control knob counterclockwise pilot position.
8. Depress control knob and push in piezo igniter button. Once pilot ignites continue to hold the control knob in for one (1) minute after the pilot is lit.
Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 – 7.
• If knob does not pop up when released, stop and immediately call your service technic i an or gas supplier.
• If the pilot will not stay lit after several attem pts, turn the gas control knob to “OFF” and call your service technici an or gas s upplier.
9. Turn gas control knob counterclockwise to “ON”. Turn on all electric power to the appliance. Set thermostat to desired setting or turn appliance
switch to “ON” position then close bottom louver.
TO TURN GAS OFF TO APPLIANCE
1.Set thermostat to lowest setting.
2.Turn off all electric power to the appliance if service is to be performed.
3.Push in gas control knob slightly and turn clockwise to “OFF”, do not force.
Note: The valve is equipped with a safety lockout, once in the “OFF” position you must wait until the thermopile has cooled before attempting
to light the pilot (approximately 3 minutes).
Page 15 of 51
Page 16
2.1 INSTRUCTIONS D'ALLUMAGE - pour veilleuse permanente
POURVOTRESÉCURITÉ,LIREAVANTD'ALLUMER
ATTENTION: Si vous ne suivez pas exactement ces instructions, un incendie ou une
explosion entraînant des dommages matériels, des blessures ou des pertes de vie.
A. Cet appareil a un pilote qui doit être allumée à la main. Lorsque l'éclairage, le pilote, suivez ces instructions à la lettre.
B. AVANT L'ALLUMAGE odeur tout autour de l'appareil pour le gaz. Soyez sûr de sentir près du plancher, car certains gaz sont plus lourds que l'air
et se déposent sur le sol.
QUE FAIRE SI VOUS UNE ODEUR DE GAZ
• Ne tentez pas d'allumer l'appareil.
• Ne pas toucher à aucun interrupteur électrique; n'utilisez aucun téléphone dans votre édifice.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur de gaz.
• Si vous ne pouvez pas joindre votre fournisseur de gaz, appelez les pompiers.
C. Utilisez seulement votre main pour enfoncer ou tourner le bout on de cont rôle du gaz. Ne jam ais utiliser d'outils. Si le bouton ne s era pas enfoncer
ou tourner à la main, ne pas essayer de le réparer, appelez un techni ci en qualif ié. Réparation de la f orce ou la tent ative peut entraîner un incendi e
ou une explosion.
D. Ne pas utiliser cet appareil si une partie a été sous l'eau. Appelez immédiatement un technici en qualifié pour inspecter l'appareil et remplacer toute
partie du système de contrôle et toute commande de gaz qui a été sous l'eau.
INSTRUCTIONS D'ALLUMAGE
1. STOP! Lire les consignes de sécurité ci-dessus sur cette étiquette.
2. Réglez le thermostat à réglage le plus bas.
3. Coupez l'alimentation élect rique de l'apparei l .
4. Les contrôles sont accessibles par l'ouverture de la persienne inférieure.
5. Poussez le bouton de contrôle du gaz et tourner vers la droite pour “OFF”.
6. Attendez cinq (5) minutes pour laisser échapper tout le gaz. Puis une odeur de gaz, y compris près du plancher. Si vous sentez une odeur de gaz,
ARRÊTEZ! Suivez «B» des consignes de sécurité ci-dessus sur cette étiquette. Si vous ne sentez pas de gaz, passez à l'étape suivante.
7. Tourner le bouton de commande antihoraire
8. Enfoncez le bouton de commande et de pousser dans piézo allumeur bouton. Une fois pilote s'enflamme continuent à tenir le bouton de
commande pour un (1) minute après que le pilote est allumée. Relâchez le bouton et il apparaîtra sauvegarder. Veilleuse doit rester allumée. Si
elle s'éteint, répétez les étapes 4 - 7.
• Si le bouton ne fait pas apparaître même, arrêtez et appelez immédiatement votre technicien ou vot re fourniss eur de gaz.
• Si le pilote ne reste pas allumée après plusieurs tentatives, tournez le bouton de contrôle du gaz à "OFF" et appelez votre technicien ou votre
fournisseur de gaz.
9. Tourner le bouton de contrôle du gaz antihoraire sur "ON". Rétablissez l'alimentation électrique de l'appareil. Réglez le thermostat à la
température désirée ou tournez le commutateur appareil pour position "ON" persienne inférieure puis fermez.
1.Réglez le thermostat à réglage le plus bas.
2.Coupez l'alimentation électrique de l'appareil si le service doit être exécuté.
3.Poussez le bouton de contrôle du gaz et tourner dans le sens horaire sur "OFF", ne forcez pas.
Remarque: La vanne est équipée d'un verrouillage de sécurité, une fois dans la position " OFF" vous devez attendre que la thermopile a
refroidi avant de tenter d'allumer la veilleuse (environ 3 minutes).
poste de pilote.
À coupez le gaz À L'APPAREIL
Page 16 of 51
Page 17
Apex Control Valve
WARNING
Do not connect 120 VAC to the g as control valve or it’s components as this will
composantes, car cela endommagerait la vanne.
2.2 HEAT OUTPUT ADJUSTMENT
The valve supplied with the appliance has a HI/LO knob to control the heat output and flame height
(see valve diagram in Lighting Instructions, section 2.1).
3.0 INSTALLATION
3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET
DE SECURITE
Read all instructions before starting installation and follow them carefully during installation to ensure
maximum benefit and safety. Failure to follow these instructions will void your warranty and may
present a fire hazard. See the warranty at the back of this manual for disclaimers regarding improper
installation. This direct vent fireplace and it’s components are tested and safe when installed in
accordance with this installation manual.
Lisez toutes les instructions avant de commencer l'installation et de les suivre attentivement lors de
l'installation pour assurer un bénéfice et une sécurité maximales. Le non respect de ces instructions
annule la garantie et peut présenter un risque d'incendie. Voir la garantie à l'arrière de ce manuel
pour décharges de responsabilité concernant une mauvaise installation. Ce foyer à évacuation
directe et ses composantes sont testés et sûrs lorsqu'il est installé conformément aux instructions de
montage.
damage the valve.
Ne pas communiquer 120 VAC à la valve de contrôle du gaz ou de ses
Page 17 of 51
Page 18
3.2 UNPACKING
NOTE
ALL INSTALLATIONS REQUIRE VENTING.
Foyer au gaz à evacuation. Ne pas utiliser avec du combustible solide
Please check the appliance carefully for any damaged or missing components (specifically check the
glass condition). Report any problems to your dealer within 30 days of purchase.
3.3 INSTALLATION
For satisfactory results it is necessary to plan certain aspects of the installation prior to the
appliance’s final positioning. These include the vent system, the gas piping, and the fans wiring.
Combustible surfaces such as the hearth, mantle, and facing must also be planned for. Be sure to
leave adequate clearance for servicing and proper operation.
Pour des résultats satisfaisants, il est nécessaire de planifier certains aspects de l'installation avant le
positionnement final de l'appareil. Il s'agit notamment du système de ventilation, les canalisations de
gaz, et le câblage fans. surfaces combustibles tels que le foyer, le manteau, et en face doivent
également être prévues pour. N'oubliez pas de laisser un espace suffisant pour l'entretien et bon.
Vented Gas Fireplace Not for Use with Solid Fuel
TOUTES LES INSTALLATIONS exigez l'aération.
Page 18 of 51
Page 19
3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS
A = 38”
TO INTERNAL CEILING
B = 1”
TO INTERNAL SIDE COMBUSTIBLES (0” TO STANDOFFS)
C = 8.75”
TO BACK WALL FROM FRONT OF UNIT (0” TO STANDOFFS)
D = 6”
TO SIDE WALL
E = 32.5”
FROM BOTTOM OF FIREPLACE TO COMBUSTIBLE MATERIAL
F=36”
MINIMUM CEILING HEIGHT FROM TOP OF UNIT
G=40”
MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE
(SEE DIAGRAM NEXT PAGE)
0”
BASE OF UNIT TO FLOOR
0.75”
REAR OF FIREPLACE TO BACK WALL
E 32.50”
36.00”
B1.00”
B1.00”
0.75”
C8.75”
A 38.00”
6.00”
40.00”
12.00”
29.00”
F 36.00”
NON-
RD 9.5” X 36”
COMBUSTIBLE
BOA
SUPPLIED BY
MANUFACTURER
G
D
Clearances are in accordance with local installation codes and the requirements of the gas supplier.
**
The mantel pl ace ment c ha rt on this pa ge il lus tr ates t he al l owa ble mant el si zes an d pl ace ment s. The 45 de gree angl e c an be
used to determine the allowable mantel size based on the elevation above the units upper trim.
Les dégagements sont en conformité avec les codes d'installation locaux et les exigences du fournisseur de gaz.
** Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles cheminée. L'angle de
45 degrés peut être utilisé pour déterminer la taille permise manteau repose sur l'élévation au-dessus de la garniture unités
supérieures.
Page 19 of 51
Page 20
When using paint or lacquer to finish the mantel, such paint or lacquer must be heat
resistant ( up to 250o F ) to prevent discolorations.
WARNING
AVERTISSEMENT
DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS
Upon initial firing check manifold pressure at pressure tap located on the front control
situé sur le panneau de commande avant (voir les Consignes d'allumage à la section 2.1).
Lors de l'utilisation de peinture ou de laque à la fin de la cheminée, de peinture ou
CAU TION
ATTENTION
laque doit être résistante à la chaleur (jusqu'à 250o F) pour prévenir la décoloration.
3.3.2 GAS LINE INSTALLATION / INSTALLATION DE LA LIGNE de GAZ
Install supply line using any pipi ng approved for your ins tallation meeting CA N/CGA 6.10, AA 3, ANSI Z21.24 or Z21.45. A
qualified g as fitter should install the gas line in accordance with all local bui lding codes. If codes permit, coiled copper
tubing may be used f or gas supply.
Installez la l igne d'ap provi sionn ement e n util isan t to ute la t uyaut eri e appro uvé pou r vot re réu nion d'ins tall ati on C AN / CGA
6.10, AA 3, ANSI Z21.2 4 ou Z 21.45. Un ins tal lat eur de gaz q ualif ié doi t i nstal ler l a ca nalis atio n de gaz en c onfo rmité avec
les codes du bâti me nt l oc aux . Si l es co des le pe rmet te nt , tu be de c ui vr e en ro ulé pe ut êt re u til i sé p our l ' app rovi si o nne ment
en gaz.
Pressure taps ar e provided on the gas c ontrol for t est gauge connections to measure the manifold and inlet pressur es (see
Lighting Instructions).
Les sont fournis sur la commande de gaz pour les connexions prises de pression gabarit d'essai pour mesurer les
pressions mul t iples et d'un e entrée (voir les Consignes d' allumage).
This appliance m ust be isolated fr om the gas supply pipi ng system by closin g its individual manual shut off va lve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).
Cet appareil doit être isolé de l'alimentation en gaz en fermant son robinet arrêt pendant tout test de pression de la
canalisat i on de gaz à une press ion égale ou inf érieure à 1/2 psi (3.45 kPa).
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any
pressure test ing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
L'appareil e t son robinet d’arr
supérieures à
Install the gas line as follows:
1/2 psi (3.45 kPa).
êt doit être déconnect ée de la canalisation de gaz pendant tout test de pression du système à des pressions
The appliance shall be installed with a manual shut off ball valve and additional pressure regulator t o bri ng line
pressure down to 14” w.c..
Installez la conduite de gaz comme suit:
L'appareil doit être installé avec une vanne manuelle à billes et régulateur de pression supplémentaire pour faire
pression ligne vers le bas à 14 "wc.
panel (see Lighting Instructions in section 2.1 ).
NOTE
Lors de la première vérification de la pression de tir collecteur à la pression du robinet
NE PAS UTILISER UNE FLAMME DE TEST DE FUITES DE GAZ
Page 20 of 51
Page 21
3.3.3 THERMOSTAT, WALL SWITCH OR DIGITAL ON/OFF REMOTE INSTALLATION
WIRE SIZE
MAX. WIRE LENGTH
AWG
mm
ft. m 22
0.6
10
3.0
20
0.8
25
7.6
18
1.0
40
12.2
16
1.3
64
19.5
14
1.6
100
30.5
The thermostat, digital on/off remote or wall switch MUST be rated for millivolt use. Minimize
les épissures inévitable.
The burner control knob is located in the control compartment at the bottom of the unit. For your convenience,
the unit can also be operated by a thermostat, a digital on/off remote or a wall switch control. Millivolt
thermostats are available from any authorized Inca Metal Cutting dealer. Bedroom installations require the use
of a wall thermostat.
Note:
Thermostats are not allowed in the United States.
Le bouton de commande du brûleur est situé dans le compartiment de commande au bas de l'appareil. Pour
votre commodité, l'appareil peut également être exploité par un thermostat, un appareil photo numérique on / off
à distance ou une commande de l'interrupteur mural. Thermostats millivolts sont disponibles depuis n'importe
quel revendeur agréé Inca Metal Cutting. Chambre installations nécessitent l'utilisation d'un thermostat mural.
Remarque:
Les thermostats ne sont pas autorisés aux Etats-Unis.
splicing in all millivolt wiring & crimp all unavoidable splices.
Le thermostat numérique, télécommande marche / arrêt ou l'interrupteur mural doit être évalué pour
NOTE
une utilisation en millivolts. Minimiser épissage dans l'ensemble du câblage millivolt & sertir toutes
Thermostat, Digital On/Off Remote or Wall Switch Installation
Mount the thermostat, digital on/off remote or wall switch in the desired location and run
thermostat wire”
to the unit’s lower right hand corner, close to the gas supply line.
“two conductor
Monter le thermostat numérique, télécommande marche / arrêt ou l'interrupteur mural à l'endroit désiré et
exécuter "les deux fils du thermostat d'orchestre" au coin de l'appareil en bas à droite, près de la ligne
d'alim e ntatio n en g a z.
1. Purchase
“two conductor thermostat wire”
, which is not provided, at any local supplier. The gauge of
thermostat wire will determine the maximum wire length and distance at which to locate the thermostat,
digital on/off remote or wall switch. See Table 1 and the information packaged with thermostat. Be
aware that as the length of wire increases, the probability of adequate operating voltage decreases.
Achat "deux fils du thermostat d'orchestre», qui n'est pas fourni, à tout fournisseur local. La
jauge de fil de thermostat de déterminer la longueur de câble maximale et la distance à
laquelle de localiser le thermostat numérique, interrupteur marche / arrêt à distance ou au
mur. Voi r l e T a bleau 1 et les informations fournies avec le thermostat. Soyez conscient que la
longueur du câble augmente, la probabilité de la tension de fonctionnement adéquat diminue.
TABLE 1 THERMOSTAT WIRE INFORMATION
Page 21 of 51
Page 22
2)
After the unit is installed and the gas line hooked up, crimp a fork connector to each wire and
attach them to the TH/TP and TH screws located on the valve.
Après que l'unité est installée et la conduite de gaz accroché, sertir un connecteur fourchette pour
chaque fil et les joindre à la vis TH / TP et TH situé sur la valve.
3) Check tests can be performed on the valve by using the trouble-shooting guide, Section 5.0.
Vérifiez les tests peuvent être effectués sur la valve en utilisant le guide de dépannage, la
sectio n 5.0.
4) This switch may be connected in parallel with a thermostat, digital on/off remote or wall switch (see Figure
4).
Ce commutateur peut être connecté en parallèle avec un thermostat numérique, télécommande
marche / arrêt ou un interrupteur mural (voir Figure 4).
Figure 4
3.3.4 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION
The unit must be connected to listed 2-ply aluminium venting, 3” flex vent on the exhaust side and listed 6” flex
vent on th e air inta k e si d e. I nstall the vent components according to the manufacturer's instructions being sure
to use spacers (see Figure 5) every 5’ to ensure correct spacing is maintained between air intake and exhaust.
Slope horizontal pipe at least 1/4" (6 mm) rise per foot of horizontal run away from the fireplace. Allow 1" (25
mm) clearance to the vent. Refer to the graph for allowable vent configurations. Be sure to ensure that
termination area allows enough room for adequate combustion and ventilation air and that the flow of combustion
and ventilation air is not obstructed.
L'appareil doit être connecté à cotée 2 couches d'aluminium ventilation , 3 "flex évent sur le côté de
l'échappement et répertoriés 6 " flex évent sur le côté d'ad mission d'air . Installez les composants de ventilation
selon les instructions du fabricant en veillant à utiliser des entretoises ( voir figure 5) tous les 5 ' pour assurer un
espacement correct est maintenu entre l'apport d'air et l'échappement. Pente tuyau horizontal d'au moins 1/4 "
( 6 mm ) par pied de course horizontale loin du foyer . Laisser 1 " ( 25 mm) à l'évent . Reportez-vous au
graphique de configuration de l'évacuation admissibles . Veillez à ce que la zone de terminaison permet assez
de place pour combustion et l'air de ventilation et que le débit de combustion et de l'air de ventilation n'est pas
obstruée.
Page 22 of 51
Page 23
If at any time the vent-air intake piping is dismantled, use the vent manufacturer’s
instructions and the sealing instructions for reassembly.
remontage
Si à tout moment de la tuyauterie d'admission d'air de ventilation est démontée, utilisez
NOTE
la ventilation instructions du fabricant et les instructions d'é tanché ité pour le
Figure 5
This appliance’s venting system is room sealed or Direct Vent. This means that it does not require
room air for combustion but draws air from outside the building.
USE OF COUPLERS – WITH FLEX PIPE
In the event of a puncture of the vent pipe or if an extension is needed couplers may be used. High
temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted
into the flex vent. Use 3 #8 x ½” hex head sheet metal screws on each end of the joint to fasten the
coupler to the venting.
Figure 6
Page 23 of 51
Page 24
2-Ply Aluminum Flex Vent
EXAMPLES
MINUMUM VERTICAL (V1 + V2)
MAXIMUM HORIZONTAL (H1 + H2 + H3 + H4)
4’
10’
8’
20’
MAXIMUM VERTICAL HEIGHT = 34 ’
MAXIMUM 90° ELBOWS PERMITTED = 3
V1
20’
H1
H2
V2
H3
34’
A
ABB
Restrict @ 60%
Restrict @ 40%
Restrict @ 20%
The minimum vent system for horizontal termination must consist of:
2” (50.8 mm) vertical length (measured to center of vent pipe) with a 45 degree bend and a
9.5” (241 mm) horizontal length (measured from center of vent pipe)
Wall thimble part# B92
Horizontal termination cap part # 1393
The maximum horizontal vent system consists of:
34’ (10363 mm) vertical length with 3 - 90 degree bends and a 20’ (6096 mm) horizontal
length (measured to center of vent pipe)
Wall thimble part# 1392
Horizontal termination cap part # 1393
Note: 2-Ply Horizontal venting shall be supported, by means of a steel strap, every 3’.
(Example: Where A---A = Vertical @ 2’
And B---B = Horizontal @ 5’)
MAXIMUM HORIZONTAL OFFSETS = 20’
Page 24 of 51
Page 25
USE OF SEALANT
A minimum clearance to combustibles must be maintained around the vent pipe of 1”
Vent Configuration
Restrictor Size
6’
60%
18’
40%
26’
20%
Apply RTV high temperature
RESTRICTOR PLATE
Sealant is required on vent system joints, (figure 7). On longer vent runs, especially vertical runs,
sealant will ensure that the combustion air enters from outdoors, and not through the vent joints. Use
high temperature sealant, available from local suppliers, on the inner pipe joint, applying the sealant
around the outside of the male part of the vent. A bead of silicone should be used on the outside of
the joint after assembly to seal the supply air. If the venting is disconnected for servicing, be sure to
follow above instructions for resealing venting when reconnecting to system.
on all horizontal and vertical pipe runs
Un dégagement minimum aux matériaux combustibles doit être mainte nu autour du
NOTE
tuyau de 1 "sur toutes les canalisations horizontales et verticales fonctionne
FIGURE 7
sealant around male pipe.
VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restricto r Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Align holes in the Restrictor that match the required degree of restriction
3/. Fasten Restrictor Plate back in place.
.
Page 25 of 51
Page 26
Horizontal Wall Vent Terminations
ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD
des risques d'incendie.
12.00”
9.00”
HEAT DEFLECTOR MUST
BE INSTALLED FOR
MINIMUM 38” INTERNAL
CEILING
9.00”
Ø 8.00”
12.00”
9 X 9 MIN OPENING
WALL THIMBLE 8"
OUTER PIPE 6”
The position of the horizontal vent termination must be positioned in such a way as to meet all local building
codes. Attach the correct length of pipe. Mark the center line of the pipe facing the wall (allowing for a 1/4”
rise per foot of horizontal, example 10 ft of horizontal would require a rise of 2.5”).
CAUSE POOR COMBUSTION AND/OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE
HAZARD.
NOTE
PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT
PROVOQUER une mauvaise combustion et / ou de températures élevées qui peuvent présenter
SIDE VIEW OF
TERMINATION
VENT
VIEW OF SAFETY CAGE
Mark a 9” x 9” square around the center mark (inside dimensions). Cut and frame the exterior wall to accept
the wall thimble. Install the wall thimble, on the inside of the exterior wall, shield using wood screws.
Attach the venting to the termination using sheet metal screws. To install the termination attach the 3” exhaust
to the termination and fasten with 3 #8 x ½” hex head sheet metal screws then attach the 6” vent to the
termination and fasten with 4 #8 x ½” hex head sheet metal screws, be sure that the flex vent overlaps the
termination collars a minimum of 2”. Then attach the termination to the exterior wall using four wood screws
through the holes in the corner of the vent terminal.
The next step is to apply a bead of mil-pac or RTV 106 to top of the 3” exhaust collar on the unit and attach the
3” vent using screws (as described above), finally apply a bead of mil-pac or RTV 106 to top of the 6” vent and
attach (as described above).
Page 26 of 51
Page 27
Safety Cage / Cage de sécurité
ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING. CLEARANCES ETC,
varier d'ÉTAT (PROVINCE).
9” x 9” opening
3
12.00
A safety cage may be required on low terminations. Please check with your local safety authority.
Une cage de sécurité peut être nécessaire de faibles terminaisons. S'il vous plaît vérifiez auprès de
votre autorité de sécurité locale.
Vertical Installations
Always maintain a 1” clearance around the vent pipe (vertical) and 1” clearance horizontal, when passing
through ceilings, walls, roofs, enclosures, attic rafter or any combustible surfaces.
DO NOT PACK AIR SPACES WITH INSULATION
NE PAS PACK ESPACES D'AIR AVEC ISOLATION
NOTE
When passing through a flat ceiling install a Box/Wall thimble. Cut a 9” square hole and frame as shown in
the diagram below.
MAY VARY FROM STATE TO STATE (PROVINCE TO PROVINCE).
TOUJOURS vérifier les codes locaux avant l'installation VENTILATION. ETC DÉGAGEMENTS, peut
NOTE
.00
The diagram at right shows the
minimum clearances as per the
chart on following page.
Page 27 of 51
Page 28
0” 0”
3” 3”
In accordance with the current CSA B149.1,
e a
sidewalk or paved driveway that is located
between two single family dwellings and
Permitted only if veranda, porch, deck or
one of the following
G= Clearance to inside corner of combustible surface
J= Clearance to nonmechanical 6 in (15cm) for appliances ≤10,000 6 in (15cm) for appliances ≤10,000
air supply inlet to building or Btuh (3kW), 12 in (30 cm) for Btuh (3kW), 9 in (23 cm) for
the combus tion a ir inlet to appliances >10,000 Btuh (3kW) and appliances >10,000 Btuh (3kW0 and
any other a ppliance ≤100,000 Btuh (30kW), 36 in (91 cm) ≤50,000 Btuh (15kW), 12 in (30cm)
for appliances >100,000 Btuh (30kW) for appliances >50,000 Btuh (15kW0
K= Clearance to a mechanical 6 ft (1.83 m) 3 ft (91 cm) above if withi n 1 0 f t
air supply inlet (3 m) horizontally
L= Clearance above paved sidewalk 7 ft (2.13 m) †
or paved driveway located on
public property *
M= Clearance under veranda, 12 in (30 cm) ‡
porch deck or balcony *
1
Natural Gas and Propane Installation Code
2In accordance with the current ANSI Z223.1 /
NFPA 54, National Fuel Gas Code
† A vent shall not terminate directly abov
serves both dwellings
‡
balcony is fully open on a minimu m of tw o
sides beneath the floor
* For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA B149. 1
shall be indicated
a). A minimum clearance value determined by
testing in accordance with section 2.23.5, or:
b). A reference to the following footnote:
“Clearance in accordance with local installation
codes and the requirements of the gas supplier.”
Page 28 of 51
Page 29
3.3.5 GLASS INSTALLATION / VERRE D'INSTALLATION
WARNING
AVERTISSEMENT
YOU MUST WEAR FLAME AND HEAT RESISTANT GLOVES FOR THESE ADJUSTMENTS.
AJUSTEMENTS.
Step 1.
Sprinkle burner channel with glass../ Canal du brûleur Saupoudrer de verre.
Step 2
Install the door see instruc ti ons bel ow. Make sure to cover the burner pan evenly / Installez la porte
voir les instructions ci-dessous. Assurez-vous de couvrir la casserole du brûleur régulièrement
Turn your fireplace on and wait approximately 10-15 minutes until the flames are a nice yellow colour.
Note the flame pattern and in any low or high areas adjust the amount of river glass to correct gas
flow. / Transformez votre cheminée et attendez environ 10-15 minutes jusqu'à ce que les flamm es
sont une belle couleur jaune. Notez la forme de la flamme et dans tous les domaines à basse ou
haute ajuster la quantité de verre rivière pour corriger débit de gaz.
VOUS PORTER DES GANTS DE FLAMME ET RESISTANT A LA CHALEUR DE CES
Page 29 of 51
Page 30
3.3.6
BOTTOM DOOR CHANNEL
BOTTOM DOOR CHANNEL
DOOR INSTALLATION AND SAFETY SCREEN / INSTALLATION DE LA PORTE ET ÉCRAN DE SÉCU RI T É
Place the bottom of the door into the Bottom Door Channel / Placez le bas de la porte dans la
Manche de bas de porte
When closed properly the door latch will hook over the top of the door bracket and seal the door onto
the fireplace. / Quand il est fermé correctement le loquet se brancher sur le dessus du support de
porte et sceller la porte sur la cheminée.
Removal is in reverse order. / L'enlèvement est dans l'ordre inverse.
Page 30 of 51
Page 31
If the glass has been damaged or broken it is highly recommended that you contact a qualified
Do not operate this appliance with the glass front rem oved, cracked or broken.
• Ne pas les portes en verre d'abus, par la suppression ou claquement fermé
DEPTH SERRATIONS
PINS
service person. Remove the broken pieces (be sure to wear gloves) and remove door.See the
replacement parts list, at the end of the manual, you will require one 5 mm ceramic glass panel with
gasket installed. Lay in a blob of high temperature silicone in each of the four corners of the door
Then follow the instructions above to re-install the door.
Si le verre a été endommagé ou cassé, il est fortement recommandé que vous contactez une
personne qualifiée. Retirez les morceaux (n'oubliez pas de porter des gants) et enlever la porte. Voir
la liste des pièces de rechange, à la fin du manuel, vous aurez besoin d'un panneau de verre 5 mm
en céramique avec un joint installé. Laïcs dans une goutte de silicone à haute température dans
chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le
panneau de verre de nouveau dans le cadre de la porte. Puis suivez les instructions ci-dessus pour
ré-installer la porte.
Replacement of the glass should be done by a licensed or qualified service person.
• For use with glass doors certified with the appliance only
• Do not use any substitute materials
• Do not abuse glass doors by striking or slamming shut
Ne pas faire fonctionner cet appareil avec la façade en verre est enlevée, fissurée ou
cassée.
WARNING
Remplacement de la vitre doit être effectué par un technicien spécialisé ou agrée.
AVERTISSEMENT
• Pour utilization uniquement avec les portes en verre certifies avec l’appareil
• Ne pas utiliser de matériaux de substitution
Picture shown is looking at the left
side of the fireplace and
illustrating the screen bracket
depth serrations mounted on pins
This unit comes with a mandatory safety screen which is mechanically attached to the fireplace.
Page 31 of 51
Page 32
3.3.7 INITIAL FIRING
It is normal for the appliance to expand and contract while it heats up or cools down
Il est normal que l 'appareil à dilater et se contracter pendant qu'elle se réchauffe ou se
la contraction des pièces métalliques peuvent produire des sons
When lit for the first few times, the applia nce may emit an odor resulting from evapor a t ion of paint and
lubricants used in the manufacturing process. Open a door or window for ventilation. Anyone with a
respiratory condition may need to leave the room during the initial firings.
whether this is from a cold start or a steady-state condition where the fan has come on
or off. Under these circumstances it is possible that the expansion/contraction of the
metal parts may produce sounds.
NOTE
refroidit s'il s'agit d'un démarrage à froid ou d'un état d'équilibre où le ventilateur est
venu sous ou hors tension. Dans ces circonstances, il est possible que l'expansion et
Occasionally, after a cold start, vapor may condense and fog the glass, and the flames may be
partially blue. After a few minutes the moisture will disappear and the flames will become yellow.
Visually check the flame after warm-up. / Parfois, après un démarrage à froid, la vapeur peut se
condenser et voiler le verre, et les flammes peuvent être partiellement bleu. Après quelques minutes,
l'humidité disparaît et les flammes deviendront jaunes. Contrôler visuellement la flamme après
l'échauffement.
3.3.8 MANIFOLD PRESSURE REGULATOR ADJUSTMENT
The manifold pressure regulator controls gas input and flame height, and is pre-adjusted at the
factory. No further adjustment is required.
PILOT FLAME ADJUSTMENT
For proper operation, the pil ot and m ain burner f lames m ust be steady and
not lifting off or floating. The top 3/8” – 1/2” (10-13mm) of the
thermocouple should be
engulfed by the pilot f lame.
3.3.9 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
Aeration is factory set but may need adjustment for altitude or movement during shipping. / L'aération est
réglée en usine, mais peut néc es s i ter un ajustement de l'altitude ou le mouvement pendant l e transport.
To adjust the air shutter / Pour ajuster l'obturateur d'air
1/. Turn off the gas / Fermez le gaz
2/. Remove the door / Enlevez la porte
3/. Remove glass from burner / Retirer le verre ou de brûleur
4/. Remove the burner pan / Retirer la casserole du brûleur
Page 32 of 51
Page 33
Factory Setting
Natural Gas – open 1/8” (3.175mm)
5/. Undo the set screw on the air shutter and adjust accordingl y then retighten the set screw. / Défaire la
PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT.
PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE
Altitude
Natural Gas – Orifice Size
0 – 4500 ft (0 – 1372 m)
48
4500 – 6500 ft (1372 - 1981 m)
49
6500 – 8500 ft (1981 - 2591 m)
50
Air tube and Air shutter shown removed
for clarity purposes only.
Set Screw
vis de réglage sur le volet d'air et d'aj us ter en conséquence, puis resserrez la vis de
réglage.
6/. Reassemble the fireplac e i n r everse order from 4 through 2. / Remonter la cheminée dans l'ordre
inverse de 4 à 2.
7/. Turn on the gas. / Allum ez le gaz.
CAUTION
ATTENTION
Aeration adjustment is important for the correct functioning of the appliance. Carbon build up, flame
lifting or any malfunction due to improper aeration adjustment during installation is not covered under
the factory warranty.
Réglage de l'aération est importante pour le fonctionnement correct de l'appareil. Une accumulation
de carbone, de levage flammes ou de toute défaillance due à une mauvaise aération d'ajustement
lors de l'installation n'est pas couvert par la garantie d'usine.
3.3.10 ALTITUDE ADJUSTMENT
All valves have been pre-set and certified for installation at elevations from 0 – 4500 feet (0-1372m)
above sea level.
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing
the existing burner orifice with a smaller size for installations over 4500 fee t (1372m). For the USA,
de-rate the unit from sea level according to the gas installation code.
Toutes les vannes ont été pré-programmées et certifié pour l'installation à une altitude de 0 à 4500
pieds (0-1372m) d’altitude
Lors de l'installation de cet appareil à haute altitude, il est nécessaire de baisser la note d'entrée par
le remplacement de l'orifice du brûleur existant avec une taille plus petite pour les installations de plus
de 4500 pieds (1372m). Pour les États-Unis, de taux de l'unité de niveau de la mer selon le code
d'installation de gaz
Page 33 of 51
Page 34
3.3.11 GAS VALVE ACCESSIBILITY / ACCESSIBILITÉ ROBINET DE GAZ.
TURN THE MAIN GAS & POWER OFF TO FIREP LACE BEFORE COMMENCING ANY
LICENCE, VOTRE FOURNISSEUR DE GAZ.
BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL G AS CONNECTIONS AFTER
GAZ APRÈS LA RÉINSTALLATION DE LA VANNE.
SCREW
WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED
GAS INSTALLER
TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE
CAUTION
COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE
ATTENTION
1/. Remove the door as in 3.3.6 / Enlevez la porte comme dans 3.3.6
2/. Undo the screws on the valve mount brackets at either end of the valve and slide valve out
through access panel below door. / Défaire les vis sur les supports de montage de soupape à chaque
extrémité de la soupape et de soupape coulissant à travers le panneau d'accès inférieur de la porte.
WARNING
AVERTISSEMENT
REINSTALLATION OF VALVE.
IL EST INDISPENSABLE DE VÉRIFIER LES FUITES DE GAZ A TOUS LES CONNEXIONS DE
Page 34 of 51
Page 35
4.0 MAINTENA NCE
WARNING
AVERTISSEMENT
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
4.1 MAINTENANCE SAFETY / SÉCURITÉ ENTRETIEN
30 MINUTES BEFORE SERVICING.
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
Service and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a professional service technician. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc. It is important that the access
door compartment, burner, and circulating air passageways be kept clean to provide for adequate
combustion and ventilation airflow. Do not substitute materials or use components other than factory
supplied.
Entretien et réparation doit être effectuée par un technicien qualifié. L'appareil doit être inspecté avant
son utilisation et au moins une fois par an par un technicien de service professionnel. Un nettoyage
plus fréquent peut être nécessaire en raison des peluches provenant des tapis litière, etc Il est
important que des passages d'air du compartiment porte d'accès, le brûleur et circulant être maintenu
propre pour fournir une combustion adéquate et ventilation d'air. Ne pas remplacer les matériaux ou
utiliser des composants autres que l'usine fournie.
4.2 RECOMMENDED SERVICE / SERVICE RECOMMANDÉ
1. The venting system should be annually inspected by a qualified agency. / Le système de
ventilation devrait être inspectés annuellement par une agence qualifiée.
2. Visually check the burner and pilot flames occasionally. Visually inspect height and color of
flames / Contrôler visuellement le brûleur et les flammes pilotes à l'occasion. Inspecter
visuellement la hauteur et la couleur de flammes
3. Clean the glass as needed. See section 4.3 for instructions on glass cleaning. / Nettoyez la vitre
au besoin. Voir la section 4.3 pour obtenir des instructions sur le nettoyage du verre.
4. Have the appliance inspected annually by a professional service technician. / Avez l'appareil
inspecté annuellement par un technicien de service professionnel.
5. Clean the appliance regularly. / Nettoyez l'appareil régulièrement.
Annual service: An annual service call should take between 1 – 2 hours. Start by disassembling the
unit; take off the door and remove all the glass. Clean fan with a vacuum to remove any dust.
Vacuum the whole firebox and all the air passages. Clean the burner. After everything is clean,
check all the connections and the chassis ground and reassemble. Clean the glass.
L'entretien annuel: Un appel de service annuelle devrait prendre entre 1 - 2 heures. Commencez par
démonter l'unité; décoller la porte et retirez tous verre. Nettoyer ventilateur avec un aspirateur pour
enlever toute trace de poussière. Passez l'aspirateur sur le foyer entier et tous les passages d'air.
Nettoyer le brûleur. Après tout est propre, vérifier toutes les connexions et la masse du châssis et
montons. Nettoyez la verre.
Page 35 of 51
Page 36
4.3 GLASS CLEANING / NETTOYAGE DE LA VITRE
WARNING
AVERTISSEMENT
THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY
The inside of the glass may require periodic cleaning to remove deposits left from impurities in the
gas and combustion air. For best results, use a ceramic glass cleaner or polish. Use a cleaner
suitable for ceramic glass (e.g. ceramic stove cleaner). Avoid the use of ammonia based cleaners
such as Windex®. Do not clean while hot. Do not use abrasive cleaners. Make sure you clean off
any white film on the fireplace glass as soon as possible – otherwise the glass may deteriorate.
L'intérieur de la vitre peut nécessiter un nettoyage périodique pour enlever les dépôts laissés par des
impuretés dans le gaz et l'air de combustion. Pour de meilleurs résultats, utilisez un nettoyant à vitres
en céramique ou en polonais. Utiliser un nettoyant approprié pour le verre en céramique (par
exemple céramique nettoyant poêle). Évitez l'utilisation de nettoyants à base d'ammoniac comme
Windex ®. Ne pas nettoyer à chaud. Ne pas utiliser de nettoyants abrasifs. Assurez-vous de nettoyer
n'importe quel film blanc sur la vitre cheminée dès que possible - sinon le verre risque de se
détériorer.
4.4 BURNER & PILOT CLEANING / BRULEUR ET NETTOYAGE DE PILOTE
Periodic cleaning is necessary for proper operation. Remove the burner, and check that the burner
orifice is clean. Visually inspect the pilot. Brush or blow away any dust, lint, or foreign debris. If the
pilot orifice is plugged, disassembly may be required to remove any foreign material from the orifice
or tubing. When the appliance is back in service, check the pilot flame pattern. For re-lighting, refer
to the lighting instructions in Section 2.1.
Un nettoyage périodique est nécessaire pour un fonctionnement correct. Enlever le brûleur, et vérifier
que l'orifice du brûleur est propre. Inspectez visuellement le pilote. Brossez ou soufflez la poussière,
les peluches ou les débris étrangers. Si l'orifice pilote est branché, le démontage peut être nécessaire
pour éliminer toute matière étrangère de l'orifice ou un tube. Lorsque l'appareil est remis en service,
vérifier le modèle flamme de la veilleuse. Pour ré-éclairage, reportez-vous aux instructions d'éclairage
dans la section 2.1.
4.5 VALVE AND PILOT ASSEMBLY REPLACEMENT / SOUPAPE ET
REMPLACEMENT ENSEMBLE PILOTE
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
30 MINUTES BEFORE SERVICING.
LA PROCÉDURE SUIVANTE EST EFFECTUER PAR DU PERSONNEL QUALIFIÉ
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
1. Turn off the gas at the meter. / Coupez le gaz au compteur.
2. Remove the door. / Enlevez la porte.
3. Remove the burner by loosening the screws and lifting it out see section 3.3.9. If the decorative
glass is removed from the burner pan make sure you do not get any medium around the pilot
when replacing it. / Enlever le brûleur en desserrant les vis et en soulevant it out voir la section
3.3.9. Si le verre décoratif est retiré de la cuvette du brûleur assurez-vous que vous ne recevez
pas n'importe quel support autour du pilote lors de son remplacement.
Page 36 of 51
Page 37
4. Disconnect the gas line to the appliance and disconnect the gas line from the valve to the main
orifice. / Débrancher la conduite de gaz à l'appareil et débranchez la conduite de gaz de la vanne
à l'orifice principal.
5. Remove the screws holding the valve bracket to the base of the unit and lift valve & valve bracket
out. / Re tirez les vis de fixation du support de la valve à la base de l'unité et de levée de soupape
et support de la valve à.
6. Undo the pilot gas line at the gas valve. / Annuler la conduite de gaz pilote à la vanne de gaz.
7. Disconnect the thermostat or on/off switch wires from the valve (if applicable). / Débranchez le
thermostat ou marche / arrêt fils de l'interrupteur de la vanne (si applicable).
8. Remove the gas line to the valve inlet and outlet. / Retirer la conduite de gaz à l'entrée de la
vanne et la sortie.
9. Remove the screws which hold the valve to the valve bracket. / Retirez les vis qui maintiennent la
vanne sur le support de la vanne.
10. Remove the screws fastening the pilot assembly to the pilot bracket and remove the pilot
assembly. / Retirez les vis de fixation du assemblage de la veilleuse sur le support de pilote et
retirer l'ensemble pil ot e.
11. Reassemble the components in reverse order. / Remonter les composants dans l'ordre inverse.
Page 37 of 51
Page 38
5.0 TROUBLE SHOOTIN G
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
I. Pilot will not light after
piezo ignition button
A. No spark at electrode (weak or not heat source for pilot ignition)
1. Improper ignition
1. Align the electrode with 1/8” (3mm) gap
to pilot hood
2. Poor connections at starter
and ignition electrode
2. Reconnect if loose
3. Broken ceramic cover on
ignition electrode
3. Replace pilot assembly
4. Defective piezo igniter
4. Replace piezo igniter
5. Poor grounding of piezo igniter
5. Tighten mounting nut and/or igniter
screws
B. No gas or low gas pressure
1. Gas line shut off(s) may not be
turned on
1. Turn on shut-off valves
2. Air in gas lines
2. Purge gas lines
3. Gas lines may not be
connected
3. Connect all gas lines
4. Low pressure may be caused
by bent line
4. Check for a kinked line
5. Valve control knob not fully
depressed in “PILOT” position
5. Fully depress control knob
II. Pilot will not stay lit after
instructions
A. Thermocouple / Valve
1. Weak or improperly located
pilot flame
1. Adjust and clean pilot. The flame must
impinge on or engulf the thermocouple.
2. Defective thermocouple
2. Replace thermocouple
3. Thermocouple not installed
3. Make sure all wire connections at the gas
mounting bracket
4. Open wire connection in pilot
circuit
4. Check wire continuity and connections in
the pilot circuit
5. Defective Valve
5. Connect the millivolt meter probes to the
Pilot will not stay lit after
B. Defective safety circuit
Loose or defective
repeated triggering of the
following the lighting
properly
following the lighting
instructions continued …
1.
connections
valve terminals are tight and the
thermocouple is fully inserted into the
thermopile terminals on the gas valve.
Turn the valve to the “PILOT” position,
depress, and light. If the meter reading is
greater than 540 millivolts after 30
seconds, the thermopile is good. If the
pilot does not stay lie, the valve is
defective. Check section “B” below,
before replacing valve
1. Check continuity, tighten wiring or
connections, and repair
Page 38 of 51
Page 39
III. Main burner will not light
A. Valve / Switches
1. Valve control off
1. Turn to “ON” position
2. Blockage at the burner (line,
orifice, or ports)
2. Check and clean
3. Defective wall switch or
thermostat
3. Conduct a continuity test or jumper wire
test and replace if defective
4. Defective wiring or
connections
4. Conduct a test with a jumper wire and
repair as required
5. Excessive length of thermostat
wire from valve to wall switch
or thermostat
5. Reduce wire length to less than 100 feet
6. Wall switch or thermostat
incorrectly wired
6. Wire correctly
7. Defective Valve
7. Turn valve and “ON/OFF” switch to the
not come on, replace the gas valve
8. Thermopile may not be
generating sufficient voltage
8. Recheck using the millivolt meter. The
thermopile
9. Wall switch, thermostat, or
9. Follow previous corrective action, check
defective
IV. Soot deposits on glass
1. Air inlet blocked or restricted
1. Clean air inlets
Vent system is restricted or
inadequate
which are approved with the appliance
V. Flame burns blue and lifts
Insufficient combustion air
2. Manifold pressure set too high
2. Check manifold pressure
3. Vent system restricted
3. Check vent system
VI. Main flame does not burn
1. Incorrect vent or termination
used.
which are approved with the appliance
t system is restricted or
inadequate
2. Manifold pressure too high
2. Check manifold pressure as required
(750 mV)
or increase wire size
“ON” position. Check with millivolt meter
at terminals TP-TH. Millivolt meter
should read greater then 540 millivolts. If
the reading is OK and the burner does
pilot flame may not be high enough for
the flame to properly engulf the
thermopile. If so, adjust and reset. If
voltage is still insufficient, replace
off burner
properly
VII. Flames impinge on firebox
top
wires are defective
2.
1.
being supplied
1. Ven
switch and wiring. Replace where
2. Confirm venting & termination are those
1. Ensure that no foreign material blocks air
inlets. Ensure the vent is adequate
1. Confirm venting & termination are those
1. Correct flue as required
Page 39 of 51
Page 40
TROUBLE SHOOTING - INTERMITTENT PILOT
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
I. Pilot will not light after
pilot
A. No spark at electrode (weak or not heat source for pilot ignition)
1. Improper ignition
1. Align the electrode with 1/8” (3mm) gap to
pilot hood
ignition electrode
3. Broken ceramic cover on
ignition electrode
3. Replace pilot assembly
4. Battery power low or dead
4. Replace batteries
B. No gas or low gas pressure
5. Gas line shut off(s) may not be
turned on
5. Turn on shut-off valves
6. Air in gas lines
6. Purge gas lines
connected
by bent line
II. Pilot will not stay lit after
instructions
A. Thermocouple / Valve
shown in Figure 27.
2. Defective thermocouple
2. Replace thermocouple
3.Thermocouple not installed
3. Make sure all wire connections at the gas
mounting bracket
4. Open wire connection in pilot
circuit
4. Check wire continuity and connections in
the pilot circuit
5. Defective Valve
5. Check with your voltmeter.
B. Defective safety circuit
connections, and repair
III. Main burner will not light
A. Valve / Switches
1. Valve control off
1. Turn to “ON” position
Blockage at the burner (line,
orifice, or ports)
3. Defective remote
3. Conduct a continuity test or jumper wire
batteries
repeated triggering of the
remote control – intermittent
2. Poor connections at starter and
7. Gas lines may not be
8. Low pressure may be caused
following the lighting
1. Weak or im properl y located pi lot
flame
2. Reconnect if loose
7. Connect all gas lines
8. Check for a kinked line
1. Adjust and clean pilot. The flame must
impinge on or engulf the thermocouple, as
properly
1. Loose or defective connections 1. Check continuity, tighten wiring or
2.
valve terminals are tight and the
thermocouple is fully inserted into the
2. Check and clean
test and replace if defective, check
Page 40 of 51
Page 41
4. Defective wiring or connections
4. Conduct a test with a jumper wire and
repair as required
5. Defective Valve
5. Contact service technician
III. Soot deposits
1. Air inlet blocked or restricted
1. Clean air inlets
Vent system is restricted or
V. Flame burns blue and lifts
2. Manifold pressure set too high
2. Check manifold pressure
3. Vent system restricted
3. Check vent system
VI. Main flame does not burn
1. Incorrect vent or termination
used.
which are approved with the appliance
Vent system is restricted or
inadequate
2. Manifold pressure too high
2. Check manifold pressure as required
off burner
properly
VII. Flames impinge on firebox
top
2.
inadequate
3. Logs are sooting up 3. Check manual for correct log placement
1. Insufficient c om bustion air be ing
supplied
1.
2. Confirm venting & termination are those
which are approved with the appliance
1. Ensure that no foreign material blocks air
inlets. Ensure the vent is adequate
1. Confirm venting & termination are those
1. Correct flue as required
Page 41 of 51
Page 42
6.0 REPLACEMENT PARTS
When requesting service or replacement parts for your unit, please provide model name and serial
number. All parts listed below may be ordered from an authorized dealer.
DescriptionPart# Certification Door 1305 N/A
Burner 1397 N/A
Door Glass 1326 ASTM C1048
Restrictor 1333 N/A
Vent Heat Deflector 1383 N/A
Door Glass Gasket 6AL N/A
Pilot Assembly (Standing pilot) PSE-NA257 CSA C & US
Orifice - NG MP0505-48 N/A
Gas Valve Apex Controls B081 CSA / UL
Piezo Igniter (R/S only) 1244-46 CSA
Glass Kit GKBL-936 N/A
Magnesium Silicate Bo ar d MSBL-936 N/A
Intermittent Pilot & R emote Control Valve Parts
Description Part#
Pilot Assembly (Intermittent) PSE-NA291 CSA / UL
Valve AF-40004 CSA C & US
Valve (with step motor installed) AF-4044 CSA C & US
Remote Step Motor for AF-4000 Valve AF-4000MOT CSA C & US
Supreme Control Module, incl.wire harness AF-4000MOD-S01 CSA C & US
Plug-in Adapter ((7.5V A/C & 24” wires) AF-4000ADP24 CSA C & US
Battery Back-up AF-4000BBU CSA C & US
Extension Module for 120V operation AF-4000120MODS01 CSA C & US
Supreme Handheld tra nsmit t er AF-4000HHS01 CSA C & US
Page 42 of 51
Page 43
7.0 INCA METAL CUTTING’S WARRANTY PROTECTION FOR ALL INCA
METAL CUTTING GAS FIREPLACE PRO DUCTS
Inca Metal Cutting’s products are designed with superior components and materials, assembled by trained
craftsmen who take great pride in their work. The burner and valve assembly are leak tested and test fired at a
quality control test station. Once assembled the complete fireplace is thoroughly inspected by a qualified
technician, before packaging, to ensure that you, the customer, receives the quality product that you expect
from Inca Metal Cutting’s.
INCA METAL CUTTING’S GAS FIREPLACE’S W ARRANTY
Your Inca Metal Cutting gas fireplace is guaranteed to be free of defects in materials and workmanship for a
period of 5 years from the date of purchase. This covers: combustion chambers, heat exchangers and burners
as well as stainless steel parts against tarnishing.
Electrical (110 volt and millivolt) components and wearable parts such as blowers, gas valves, thermal
switches, switches, wiring, remote controls, igniters, gaskets, glass (thermal damage only) and pilot
assemblies are covered for 1 year and Inca Metal Cutting will provide replacement parts free of charge during
the first year of the limited warranty
CONDITIONS AND LIMITATIONS
Inca Metal Cutting warrants its products against manufacturing defects to the original purchaser only – i.e. the
individual or legal entity (registered customer) whose name appears on the original invoice – provided that the
purchase was made through an authorized Inca Metal Cutting dealer and is subject to the following conditions
and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
A licensed, authorized service technician or contractor must have installed the gas fireplace. Installation must
be done in accordance with the installation instructions included with the product and all local and national
building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations,
abuse or neglect. Parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive
heat, abrasives, chemical cleaners nor any venting components used in the installation of the fireplace.
This warranty does not cover any problems caused to installation used venting or vent terminations which are
not certified for use with this product.
Any installation, labor, construction, transportation or other related costs or expenses arising from defective
part(s), repair or replacement or otherwise of same, will not be covered by this warranty nor shall Inca Metal
Cutting assume responsibility for same. Further, Inca Metal Cutting will not be responsible for any incidental,
indirect or consequent damages, except as provided by law, and in no event shall they exceed the original
purchase price.
In the first year only, this warranty extends to the repair or replacement of warranted parts, which are defective
in material or workmanship provided that the product has been operated in accordance with the operation
instructions and under normal conditions.
After the first year, Inca Metal Cutting may, at its dis cr et ion, f ul ly discharge all obligation s w it h r espect to this
warranty by refunding to t he or iginal warranted purchaser t he wholesale price of any warr anted but defective parts.
Page 43 of 51
Page 44
CONDITIONS AND LIMITATIONS (continued)
Notwithstanding any provisions contained in this warranty, Inca Metal Cutting’s responsibility under this
warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect
damages.
This warranty defines the obligations and liability of Inca Metal Cutting with respect to the Inca Metal Cutting
gas fireplace and any other warranties expressed or implied with respect to this product, its components or
accessories are excluded.
Inca Metal Cutting neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities
with respect to the sale of this product. Inca Metal Cutting will not be responsible for: over firing, downdrafts,
spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains,
inadequate vents, excessive venting configurations, insufficient make up air, or negative air pressures which
may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, trim or other component due to water, weather damage, long
periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of Inca
Metal Cutting.
The bill of sale or copy will be required together with a serial number and a model number when making any
warranty claims from your authorized dealer.
Inca Metal Cutting reserves the right to have its representative inspect any product or part thereof prior to
honoring any warranty claim.
7.0 GARANTIE DE PROTECTION
Produits Inca Metal Cutting sont conçus avec des composants et des matériaux de qualité supérieure,
assemblés par des artisans qualifiés qui sont fiers de leur travail. Le brûleur et la valve sont des essais
d'étanchéité et d'essai ont tiré sur un poste de contrôle de qualité. Une fois assemblé, chaque foyer est
soigneusement inspecté par un technicien qualifié, avant l'emballage, afin de s'assurer que vous, le client
reçoit le produit de qualité que vous attendez d'Inca Metal Cutting.
FOYER AU GAZ DE COUPE METAL INCA'S GARANTIE
Votre foyer au gaz Inca Metal de coupe est garanti d'être exempt de défauts de matériaux et de fabrication
pour une période de 5 ans à compter de la date d'achat. Cette garantie couvre: chambres de combustion,
échangeurs de chaleur et brûleurs ainsi que des pièces en acier inoxydable contre le ternissement.
Electrique (110 volts et millivolt) et les pièces d'usure comme les souffleuses, les vannes de gaz, capteurs
thermiques, interrupteurs, câblages, télécommandes, allumeurs, les joints, le verre (dommage thermique
seulement) et les assemblées pilotes sont couverts pendant 1 an et Inca Metal Cutting fournira de
remplacement les pièces gratuitement durant la première année de la garantie limitée
Inca Metal Cutting garanti ses produits contre les déf auts de fabrication à l'acheteur d'origine seulement - la
personne physique ou morale (client inscrit) dont le nom figure sur la f acture d'origine - à condition que l'achat
a été effectué auprès d'un revendeur autorisé Inca Metal Cutting et est soumis à les conditions et limitat ions
suivantes
Cette garantie du fabricant n'est pas transférable et ne peut être prolongé que ce soit par l'un de nos
représentants.
Une licence, un technicien de service autorisé ou l'entrepreneur doit avoir installé le foyer à gaz. Installation
Page 44 of 51
Page 45
CONDITIONS ET LIMITES (SUITE)
doit être faite en conformité avec les instructions d'installation incluses avec le produit et toutes les capacités
locales et nationales et de prévention des incend
Cette garantie limitée ne couvre pas les dommages causés par une mauvaise utilisation, manque d'entretien,
accident, des altérations, des abus ou de négligence. Installation de pièces provenant d'autres fabricants
annulera cette garantie.
Cette garantie limitée ne couvre pas non plus les égratignures, les bosselures, la corrosion ou la décoloration
causés par la chaleur excessive, les abrasifs, de nettoyants chimiques ou tout composant de ventilation utilisé
dans l'installation de la cheminée.
Cette garantie ne couvre pas les problèmes causés à l'installation d'aération ou de ventilation utilisé
licenciements qui ne sont pas homologués pour une utilisation avec ce produit.
Toute installation, le travail, la construction, le transport ou autres frais connexes ou frais découlant de la pièce
défectueuse (s), la réparation ou le remplacement ou non de même, ne seront pas couverts par cette garantie
ni Inca Metal Cutting assumer la responsabilité de même. En outre, Inca Metal Cutting ne sera pas
responsable des dommages accessoires, indirects ou conséquents, sauf dans les cas prévus par la loi, et en
aucun cas, ils dépassent le prix d'achat original.
Dans la première année seulement, cette garantie s'étend à la réparation ou le remplacement des pièces
garanties, qui sont des défauts de matériaux ou de fabrication à condition que le produit ait été utilisé
conformément aux instructions de fonctionnement et dans des conditions normales.
Après la première année, Inca de coupe en métal peut, à sa discrétion, se décharger de toutes obligations à
l'égard de cette garantie en remboursant à l'acheteur d'origine le prix de gros de toute pièce garantie qui est
défectueuse (s).
Nonobstant toutes dispositions contenues dans la présente garantie, Inca Metal Cutting responsabilité en vertu
de cette garantie est définie comme ci-dessus et il ne doit en aucun cas s'étendre à des dommages indirects,
accessoires ou indirects.
Cette garantie définit les obligations et la responsabilité de l'Inca Metal Cutting à l'égard de l'Inca Metal Cutting
foyer au gaz et toute autre garantie expresse ou implicite à l'égard de ce produit, ses composants ou
accessoires est exclue.
Inca Metal Cutting n'assume, ni n'autorise aucun tiers à assumer en son nom, toute autre responsabilité à
l'égard de la vente de ce produit. Inca Metal Cutting ne sera pas responsable d 'une surchauffe, des
refoulements, des déversements causés par les conditions environnementales telles que des toits, des
bâtiments, des arbres à proximité, des collines, des montagnes, des évents inadéquats, des configurations de
ventilation excessive, l'insuffisance des pressions d'air d'air d'appoint, ou négatives qui peuvent ou peut ne pas
être causés par des systèmes mécaniques tels que les ventilateurs, fours, les sécheuses, etc
Les dommages à la cheminée, chambre de combustion, ou pièce d'habillage d'autres à cause de l'eau, causés
par des intempéries, de longues périodes d'humidité, la condensation, des produits chimiques ou d e
nettoyants dommageables ne sera pas la responsabilité de l'Inca Metal Cutting.
L'acte de vente ou sa copie sera requise ainsi que le numéro de série et un numéro de modèle lors de toute
réclamation auprès de votre revendeur agréé.
Inca Metal Cutting se réserve le droit d'avoir son représentant d'inspecter tout produit ou pièce avant d'honorer
toute réclamation.
Page 45 of 51
Page 46
8.0 LABEL INFORMATION
Page 46 of 51
Page 47
8.0 LABEL INFO RMATION (continued)
WARNING
with a three prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or
électrique et doit être br anc hé dir ec te me nt dans une prise à trois broches réci pi e nt. Ne pas couper ou
This appliance must be properly connected to a
This is a direct vent appliance.
Electrical Grounding Instructions
This appliance is equipped
remove the grounding prong from this plug.
AVERTISSEMENT
Instructions à la terre électrique
Cet appareil est équipé d'un à trois broches (terre) pour votre protection contre les risques de choc
retirer la broche de terre de cette fiche.
venting system in accordance with the
manufacturer’s installation instructions.
Page 47 of 51
Page 48
APPENDIX A (AMERICAN FLAME VALVE INFORMATION)
Page 48 of 51
Page 49
APPENDIX A (Continued)
Page 49 of 51
Page 50
Special Features on the AF-4000 System
module that reads “Continuous Pilot ON/OFF”,
turned to ON the pilot will spark and light. When the appliance ON/OFF switch is turned OFF the pilot
c) When the Continuous Pilot switch is in the ON position and the appliance ON/OFF switch is turned
0 module has a built in remote control receiver. This allows
APPENDIX A (Continued)
The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0
volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” fem ale
terminals from the adapter to the two 1/4” male terminals, located on the AF-4000 Modul e , mark e d
POWER. The second method of powering the appliance is by using the AF-4000 BP battery pack.
The appliance will not have back up power, during power outages, if only the 6.0 volt adapter is used
however a battery back up package, AF-4000BBU, is available to be used in this situation.
The AF-4000 module has 2 special features built into the system.
Please check with local City codes regarding the use of the following feature.
1. Continuous Pilot Feature - This feature allows the user to change from a spark to pilot system to a
standing pilot system, for direct vent appliances during cold climate, to keep the firebox warm.
a) There is a switch located on the side of the AF-4000
this switch will allow the user to select the pilot mode of operation.
b) When the Continuous Pilot switch is in the OFF position and the appliance ON/OFF switch is
will shut off when the main burner shuts off.
on the pilot will spark and light. When the appliance ON/OFF switch is turned to OFF the pilot will
stay ON when the main burner shuts off. This setting is generally used in cold climates to keep the
firebox warm.
d) The Continuous Pilot mode can also be activated by an optional hand held remote control.
2. Remote Control Feature - The AF-400
the user to program a hand held remote transmitter, wireless wall mount thermostat or wireless wall
mount switch to the appliance at any time during or after the installation of the appliance.
a) There is a switch located on the side of the AF-4000 module that reads REMOTE/OFF.
b) When the Remote/Off switch is in the OFF position the appliance will operate from an appliance
mounted rocker switch or wall switch connected to the (2) brown wires on the AF-4000 module.
c) When the Remote/Off switch is in the REMOTE position the appliance will operate from the
Remote Control transmitter, wireless wall mounted thermostat or wireless wall mounted switch.
NOTE: The AF-4000 module must be programmed to the Remote Control transmitter, wireless wall
mounted thermostat or wireless wall mounted switch.
a) To program the AF-4000 locate the LEARN button on the AF-4000 mod ul e. Press and releas e
the LEARN button, the AF-4000 module will beep then press any key on the Remote Control. Once
the AF-4000 internal receiver accepts the transmitter code there will be a series of confirming beeps.
b) The Remote system is now ready for use.
Page 50 of 51
Page 51
APPENDIX A (Continued)
AF-4000 Wiring Diagram
Inca Metal Cutting Ltd
Unit 100 – 11091 Bridgeport Road
Richmond, BC V6X 1T3
Canada
Page 51 of 51