Siera IP Camera VSP 3001, VSP 3001 Instruction Manual

IP CAMERA
INSTRUCTION MANUAL
www.sieraelectronics.com
SIERA ELECTRONICS
VSP 3001 IP CAMERA
Warning: Please read this manual carefully before
using.
Complete package should include the following items:
AC adaptor 1 pc
category 5 cross cable 1 pc
I/O terminal cable 1 pc
instruction 1 pcmanual
PREFACE
1 Introduction 2
1.1 technology support
1.2 system requirements
2 Panel description 3
2.1 front view
2.2 rear view
3 Installation 4
3.1 cautions
3.2 step
4 Illustration for net connection 5
4.1 onnect with PC directly by category 5 cable
4.2 connect to INTRANET through HUB/Switch
4.3 connect to INTERNET through HUB/Switch/Router
5 IP camera pages 7
5.1 home page 5.2 video page
5.3 setup page 5.4 network
5.5 time 5.6 administrator
5.7 general user 5.8 image settings
5.9 multi-camera screen 5.10 alarm trigger
5.11 transfer image in the timer mode
5.12 background recording function
6 Recording function 18
6.1 ActiveX control recording
6.2 FTP recording
6.3 playback function
7 I/O description 19
7.1 about I/O
7.2 example about I/O
8 Appendix 20
8.1 reset to factory default
8.2 troubleshooting
8.3 UFO specifications
1
CONTENTS
1.1 Features
Built-in web server, high quality JPEG image can be displayed through Internet
browser upon connection with Ethernet.
Motion JPEG can be up to 15 frames per second with high resolution 640x480.
Through Internet, pan/tilt heads and lens can be conveniently controlled to meet
with long-range monitoring.
Based on ASP/JAVA script, web server can provide max. platform compatibility.
Based on script CGI/ASP control, the server can offer convenience for the user to
integrate applications.
Output of E-mail,TFTP,I/O triggered with date, time and I/O input.
2 users security control, prevent unregistered users accessing the system.
Recording through IE.
Recording through FTP.
1 INTRODUCTION
1.2 System requirements
The requirements for PC through which the network camera pages can be browsed
are as below:
Remarks: the CPU is recommended to be Pentium II (300MHz) or greater,
which can prevent the hardware restriction.
Item
Operation system
Network protocol
Interface
Web browser
Windows 98 Windows 2000 Windows ME Windows NT 4.0 Windows Xp
TCP/IP Intenet Agreement(HTTP, FTP, SMTP, TCP, UDP, ICMP IP)
10/100Mbps
Internet Explorer 5.0 or later Netscape Navigator 4.7 or later
Description
2
3
2.1 Front view
Lens
Power indicator
2.2 Rear view
Ethernet indicator
I/O connector
DC in jack
2 PANEL DESCRIPTION
Ethernet port
3 INSTALLATION
4
3.1 Cautions
Please read all safety instructions carefully before installation.
VSP-3001 IP camera should installed indoors generally. The prolonged exposure
under the sunlight or other strong lights shall accelerate the aging of the shell and
shorten the using term.
Please install the IP camera at safe site. The fall may cause the damage.
Do not place the network camera near water and assure the IP camera in a
dry circumstance with aeration.
Please use the proper input power source(input AC 220v and output DC12v/1A).
Don't leave the cables easy-touched to prevent the stumble.
Don't forcedly turn the pan/tilt head or lens to avoid the damage.
Don't touch the lens of the sensor. The fingerprint smudge shall cause the blur or no
image displayed and it also shall hurt the paint on the lens.
Please unplug the AC adaptor before cleaning the network camera. Please wipe wet
cloth only and don't use chemical and aerosol products.
Screen protection is recommended. The long-time display for same image of the
PC shall damage the monitor.
Please take the network camera to the qualified serviceman under the below cases:
A
If the IP camera does not work normally after the setup and debug by
operating instruction.
E If the network camera exhibits an irregular condition in performance.
3.2 Installation step
A Bracket installation: aim the screw of the bracket at the hole on the bottom and turn
clockwise.
B Ethernet connectiona: use category 5 cross cable and RJ-45 linker to connect the
network camera to the net. Use category 5 straight cable to connect with HUB/
Switch or use category 5 cross cable when connecting directly to the PC.
C Confirm the specification of the AC adaptor(input AC220v,output DC12v,1A) and
connect with the network camera.
D Check if the power source indicator is enlightened. If the net has been connected
correctly, the net indicator will be enlightened within 1 second.
when the power supply cord or plug is damaged.
B when liquid has been spilled into the IP camera.
C when the network camera has been dropped and damaged.
D
4 ILLUSTRATION FOR NET CONNECTION
5
He common connection programs for VSP-3001 network camera:
4.1 Connecting directly to PC(through category 5 cross cable)
For this program, the page browsing requires the basic configuration as below for PC and IP camera: A Connect correctly with the IP camera as above illustration. B Set up the Ethernet card of the PC as auto or 10M half duplex mode. C Set up the static IP address and the subnet masks. For example, IP address is 192.168.1.6 and subnet masks is 255.255.255.0, and ignore other setup of the net. D enter the default IP address http://192.168.1.252 into the address field of the net browser.
For this program, the page browsing requires the basic configuration as below for PC and network camera: A Connect correctly with the network camera as above illustration. B Set up the static IP address and the subnet masks. For example, IP address is
192.168.1.6 and subnet masks is 255.255.255.0, and ignore other setup of the net. C enter the default IP address http://192.168.1.252 into the address field of the net browser.
Users
Link Builder / Switcher
Users
Record server
Reticle
Cross reticle
4.2 Connecting to Intranet through HUB/Switch
6
4.3 Connecting to Internet through HUB/Switch/Router
For this program, not only the basic setup of PC and IP camera but also the setup of Port Forwarding function of Router is required, so the visit for network camera besides Intranet is accessible. The Router should have the function of Network Address Transition(NAT) to transit the global address to local address and assign the different external port No. to each IP camera.
4.4 Access home page of IP camera
If the IP browser is Internet Explorer, the download for ActiveX is required. So, reset the security level of the IE as low level(Tools menu > Internet Options > Security tab > Custom level), and then enter HTTP://192.168.1.252 to the address field to open the home page of VSP-3001 network camera. Click the Single Camera Screen Mode, and wait a minute till the image appearing, then set the security level to its original level.(The PC will save the program of ActiveX after reading it, so the security level can be set to its original level.) If the IP browser is Netscape Navigator, please enter directly HTTP://192.168.1.252 to address field to open the home page of VSP-3001
IP camera. Click the Single Camera
Screen Mode, wait a minute and then the image will appear.
INTERNET
Users
Users
Record server
Router
Reticle
Link Builder / Switcher
7
5 IP CAMERA PAGES
5.1 Home page
There are 3 options on home page:
1) image browsing (single camera screen/multi camera screen)
2) configuration
3) help
5.2 Video page
Click single camera screen mode, following dialogue box appears:
factory parameters user name admin password admin
In put network password
Please input users and password
Webserver: 192. 168. 0. 220
Domain: Camera
User(u)
Password(p)
Please store password into the list
Confirmation Cannel
8
Enter user name and password of administrator and general user, then following dialogue box appears:
click left operation bars to adjust the image directly:
Brightness 17 levels
Resolution 640 480 320 240 160 120
Quality favor clarity standard favor motion
Image size x1 x2
5.3 Setup page
Click system configuration, following dialogue box will appear if the setup of
administrator or general user has been made:
In put network password
Please input users and password
Webserver: 192. 168. 0. 220
Domain: Camera
User(u)
Password(p)
Please store password into the list
Confirmation Cannel
factory parameters user name admin password admin
9
Enter user name and password of administrator, then setup page appears.
network set up network parameters
time set up date and time
administrator set up user name and password of administrator
general user set up user name and password of general user
image set up image size
multi-camera screen set up multi-camera screen
alarm trigger
timer trigger
FTP recording
restart restart
factory default reset to factory default
version display version of hardware and software
Basic setup
Transfer
Others
10
5.4 Network
Name of network camera 4-15 English characters and 2-7 Chinese characters
Port no
Assign IP address
Assign DHCP
Gateway
Network camera management server
Notes: please restart after click save to effect the settings you entered.
The range is 1-65535(default:80). If there are 2 or more network cameras in 1 LAN and connect to Internet or other net through router, it will be possible to set different port no. for each network camera.
Bandwidth It can restrict the transmit bandwidth.
DNS
log in for user name and password.
DNS(Domain Name Server):2 DNS IP addressescan be set up. Please set it on first data field for single IP address.
Enter IP address and submit mask assigned by administrator to every data field.
DHCP(Dynamic Host Configuration Protocol):please enter the name of network camera if the system uses DHCP server function which assign IP address automatically.
Enter the default gateway.
11
5.5 Time
item description settings remarks
1.current date and time
(1) have the same time with PC
(2) input by
handwork
yyyy-mm-dd for year 1970 to 2039. hh:mm:ss for 24h mode.
Display current date and time of IP camera.
Adjust internal clock
Take the internal clock of network camera with the same time of the PC.
Input time by handwork to adjust the internal clock of network camera.
2.set up date and time
12
5.6 Administrator
[Authentication] [None]: anyone can access all pages. [administrator only]:for setup page [administrator]for setup page and [general user] for viewer page [user name and password]:user name should be 4-15 English words or 2-7 Chinese characters. Password should be 4-15 English words or numbers. User name and password should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ].
5.7 General user
[general user information]: list all user name of general users. Functions for delete and modify are offered. [first login]:register a new general user. User name and password should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ].
13
5.8 Image settings
[brightness adjust]:17 levels, control the function for brightness adjustment. [Header display]: display the name of network camera and time on image or not. [Power line frequency]: 50HZ and 60HZ optional. Select correct power frequency
and prevent fluorescent light interfering the image.
[Power indicator]: indicate the network camera is power on or not. [Image size]:100 levels for optional. It means the ratio between images before and after compression. [White balance]: according to different circumstance: auto, fixed indoor, fixed fluorescent, fixed outdoor and hold is optional.
5.9 Multi-camera screen
Can set up multi-camera screen, the number is up to 4.
14
5.10 Alarm trigger
The alarm mode means the transmission of pre and/or post alarm images held in the buffer to specified address. Alarm: select enable to confirm the alarm mode function.
[Alarm occur condition]: the alarm is subject to the rising or falling of voltage detected by the I/O connector. rising: the alarm is subject to the rising of voltage detected by the I/O connector. Falling: the alarm is subject to the falling of voltage detected by the I/O connector.
15
Item Description Remarks
IP address or host name of FTP server
port number
FTP method
login ID
Password
upload file path
over write setting
1 65535
Should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ].
[FTP transfer]
Start with / and end with / , Root directory: / (default).
Item
SMTP server addr­ess or host name
User ID required or not
User ID
Password
From To Subject Text
Name:1-255 English characters address: IP address Enter the user ID or not is subject to the authentication requirement of SMTP server when send an E-mail.
Should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ].
User ID and password is not demanded when there is no authentication.
[Mail transfer]
Notification to be sent when alarm occurs: send or not the E-mail of notification to specified E-mail address after alarm occurs.
Notes: VSP-3001 network camera will only operate correctly with mail server using SMTP (Simple Message Transfer Protocol), it is not available with the mail server accessed via web browser (address to receive the E-mail is an exception).
The E-mail of notification with no image enclosed includes
text message only. The setting for E-mail is the same as the above.
Host name: 1-255 English characters IP address: IP address of the FTP server
It means the naming rule for files
uploaded repeatedly.
The folder name of the FTP server into which the file upload.
0-15 English characters
login ID of the FTP server: 1-15 English characters.
select the FTP method: active or passive.
Description Remarks
The text of the E-mail
The subject of the E-mail
The address to send the E-mail.
The address to receive the E-mail.
Enter the password if the auth­entication is required when send an E-mail.
Enter the user ID if the authentication is required when send an E-mail.
0-63 English characters, 0-31 Chinese characters.
0-63 English characters, 0-31 Chinese characters.
[Image setting]: select the parameters for the image which shall be transferred. Image resolution: 640 480 / 320 240 / 160 120. Image quality: favor clarity / standard / favor motion [Image buffer setting]: the images held in the buffer pre and/or post alarm in short-term. Select the image buffer frequency and the number of images which shall be transferred into the buffer pre and/or post alarm. [Transfer method]: select FTP or E-mail.
16
5.11 Transfer image in the timer mode
Timer mode means sending images to specified address when the clock reaches the pre-assigned time.
[Timer]: select the function of transferring image in the timer mode or not. [Timer setting]: 8 timers is optional. [Image setting]: select the parameters of images which shall be sent when it reaches
the pre-assigned time. Resolution: 640 480 / 320 240 / 160 120. Image quality: favor clarity / standard / favor motion. [Transfer method]: select the transfer method of the images when it reaches the pre-assigned time by FTP or E-mail. FTP and E-mail setting refers to section
4.3.7(alarm trigger)
17
5.12 Background recording function
Background recording means sending images to background FTP server for recording at specified intervals.
[Record]: select the background recording function or not. [Image setting]: select the parameters of the image recorded in background. Resolution:
640 480 / 320 240 / 160 120. Image quality: favor clarity/stand/ favor motion
[image buffer frequency setting]: select the frequency for sending images for recording. [FTP server]: refer to section 4.3.7-alarm trigger-FTP. [Notification to be sent when record fail]: select the function to send an E-mail of
notification to specified address or not when record fail or record success after retry. The setting for E-mail refers to section 4.3.7-alarm trigger-E-mail.
18
6 RECORDING FUNCTION
6.1 Activex control recording
ActiveX control recording function is for IE browser only, and can not for Netscape Navigator browser. Please right-click the mouse at the image and select the recording setting in the option box appeared when browsing.
[File path]: select the folder in which JPEG files saved. [File name]: enter the file mark. Actual recorder file is name(file+date+time) [interval]
6.2 FTP recording
The FTP server is demanded. For example, Serv-U as a common type at present is suitable for personal application with features of simple setting, strong function and high stability. It can provide not only the function for downloading of files, but also the general protection for system security. The setting of password and access licensing for different users are optional. Please refer to the relevant book about Serv-U written by lv da rong. FTP setting refers to section 4.3.7(alarm trigger)
6.3 Playback function
The image can be played by free media-playback tool provided by our company or ACDSee. Open the media-playback tool, open the selected file, and play the file. The function of delay is adjustable and the function of circle is selectable. The date and time should be the same as PC.
19
7
I/O DESCRIPTION
7.1 About I/O
The I/O connector controls input and output of signal, and it includes 1 I/O input terminal, 1 I/O output terminal and 1 RS-232 converter or half duplex RS-485 port.
Port description:
Port Name Description
1 AGND analog ground 2 485B/RXD 3 485A/TXD 4 DGND digital ground 5 +12V max. output current:100mA 6 I/O-OUT 7 I/O-IN 8 hold hold
7.2 Example about I/O
Notes: the current(+12V) output to the peripheral equipment should not exceed 100mA, otherwise the overloading is possible to damage the AV adapter and inner components.
20
Appendix 1: Reset to factory default
In some case, we need reset the server to factory default which can operate on Setup Page. If the user can not login the Setup Page(such as forgetting the user name and the password), it will be available for resetting to factory default through ARP and PING to re-assign the IP address. Notes: after the success of re-assigning the IP address through ARP and PING, all other settings shall be reset to factory default except IP address setting.
8 APPENDIX
Assign IP address through ARP notes before operation:
Check the correct connection to the net and with the power for IP camera. Obtain a unique IP address from administrator. MAC address: there is a unique Ethernet address for every VSP-3001 IP camera(MAC address is labeled on bottom of the IP camera). The Ethernet address is a number with 12 figures(such as 00-0c-e8-xx-xx-xx). Fox example, the IP address for PC is 192.168.1.6, the IP address for VSP-3001 IP camera will be set as 192.168.1.61, the MAC address is 00-0c-e8-xx-xx-xx. The IP address of VSP-3001 network camera must have the same IP domain with the IP address of PC(it means the same subnet mask). For example, the IP address of PC is 192.168.1.6, the IP address of network camera is 192.168.1.61, and the subnet mask is 255.255.255.0. If the subnet mask is 255.255.255.128 or higher, the domain will not cover 192.168.1.61 and the setting will not be effective.
Operation procedure
1 IN operation system of Windows, open the DOS window and
operate as <start all programs accessory command prompt> to DOS.
21
Display as below:
C:\>arp -d
C:\>arp -s 192.168.1.61 00-0c-e8-00-00-01
C:\>ping -t 192.168.1.61
Pinging 192.168.1.61 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Reply from 192.168.1.61: bytes=32 time=5ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Ping statistics for 192.168.1.61:
Packets: Sent = 7, Received = 4, Lost = 3 (42% loss),Approximate round
trip times in milli-seconds:
Minimum = 4ms, Maximum = 5ms, Average = 2ms
Control-C
^C
C:\>arp -d
C:\>exit
2 clear ARP: enter<arp d>. 3 Set up ARP: enter<arp s 192.168.1.61 00-0c-e8-00-00-01>. 4 PING: enter<ping t 192.168.1.61>. 5 Turn off the network camera. 6 Turn on the network camera again. 7 Enter Ctrl-c after Pinging, and enter <arp-d> to clear ARP statistics. 8 Enter <exit> to quit the DOS.
22
Appendix 2: Troubleshooting
can not access the network camera via browser
the problem of Ethernet connection
Please check the VSP-3001 network camera, the Hub, the Switch and Ethernet indicator. Check their connection if there is any abnormity. Disconnect the Ethernet connection, perform PING. The success of PING shows a conflict for IP address, so re-assign the IP address of VSP-3001 network camera is needed. Check if the IP address of VSP-3001 network camera is in the same subnet with your workstation.
1.Click start>setting>control panel>network
2.Select TCP/IP ADAPTOR, and click Properties .
3.click IP address
heck the IP address and the subnet mask. Please check carefully the settings such as IP address, subnet mask, gateway and DNS if the workstation and VSP-3001
network camera is not in the same subnet. When necessary, it will be required to re-assign the IP address of VSP-3001 network camera in the same subnet.
If the web browser is Internet Explorer, the download for ActiveX is required. So, reset the security level of the IE as low level Click Tools menu > Internet Options > Security tab > Custom level . The PC will save the program of ActiveX after reading it, so the security level can be set to its original level. The frame rate is subject to the following conditions: 1 Display mode, resolution, image quality and bandwidth. 2 Performance of PC, network, theme enviroment(brightness, theme and more) 3 Overmany users visit the network camera simultaneously will prevent the image updating quickly. 4 For network cameras, if the images update slowly, please use Switch instead of HUB.
ActiveX
Bandwidth and other reasons
AC adaptor
when the image does not appear
image delay
The power LED indica­tor does not light up.
The IP address is in different subnet. There is problem in setting of gateway.
Please check the standard AC adaptor and the AC power.
Remedy
Cause
conflict of IP address
Problem
Password
IP address
Use ARP and PING to re-assign the IP address of network camera. Reset the user name of administrator and the password after resetting to factory default. Please refer to chapter 3. Use ARP and PING to re-assign the IP address of network camera. Reset the user name of administrator and the password after resetting to factory default. Please refer to chapter 3.
Forget the IP address of network camera
When forge­tting the password of setup page
23
Appendix 3: Specification
Hardware
100 levels are optional
Brightness
NTSC/PAL: 640x480, 320x240, 160x120
Ethernet(10 Base-T)
TCP/UDP/IP, ARP, ICMP, HTTP, TFTP, Telnet, SMTP
max. 30 frames/second. Net: max. 300Kbytes/second
Trigger: I/O input/timer(frequency/motion detection
Response: TFTP / E-mail / I/O output to peripheral
equipment
Assign the IP address: use ARP or through administrator page
through TELNET
Microsoft IE5.x or later, Netscape Navigator 4.x or later,
Win98/NT/2000/XP
2 layer password protection
0 - 40
20-80 %
DC12V, 1A
<10 watts
100 77mm
0.60kg with power
* Frame rate will change with the condition of a network and the PC performance.
* A sensor must be attached for alarm mode.
System requirement
Security
Operation temperature
Humidity Power
Consumption
Dimension
Weight
Image size Image
Resolution
Ethernet port
Network protocol
Performance
Trigger and response
Installation
Update firmware
CPU: 32 Bits RISC ROM: 2M Bytes Flash ROM RAM: 16M Bytes SDRAM 1 RJ-45 for Ethernet 1 I/O input terminal and 1 I/O output terminal
Loading...