Using a small flathead screwdriver or equivalent,
press and crimp the metal ring
securely onto the cable jacket.
Incorrect:
Jacket is not under crimp ring.
While maintaining inward
pressure on cable, use the diagonal cutters or equivalent to trim excess conductors flush with termination cap.
TERA
1-Pair UTP Plug Instructions
Using the CPT cable prepara-
tion tool or equivalent, strip off approximately 1-2 inches (25­51mm) of cable jacket.
Insert crimp ring into the housing with the rounded
side forward (contact side).
Install boot, narrow end first.
Maintain inward pressure on
cable and use parallel jaw pliers to terminate conductors. Squeeze cap flush with connector housing.
Note: Cable jacket should be up against termination cap.
D
B
A
C
Lace the conductors through
the housing and the crimp ring and into the termination cap. Orient the conductors in accordance with color-coded dot on cap.
Note: Cable jacket should be inserted through the crimp ring and up against termination cap.
Untwist and flatten the conductors in preparation for
insertion.
Crimp Ring
Strain Relief Boot
B
Connector Housing
C
Termination Cap
D
A
Required Tools:
• Jacket Stripper
• Diagonal Cutters
• Small Flathead Screwdriver
• Parallel Jaw Pliers
CRITICAL STEP
Slide the strain relief boot into place.
10
Swing close and latch the cover nto the connector
housing.
TERA™ 1-Pair UTP Plug Instructions
57S5
Inspect finished connector.
11
To assist safe installations, comply with the following:
A. Use caution when installing or modifying
telecommunications circuits.
B. Never touch uninsulated wire terminals unless
the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
To assist safe installations, comply with the following:
A. Use caution when installing or modifying
telecommunications circuits.
B. Never touch uninsulated wire terminals unless
the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
Rev. C 5/02 100.10419
© 2002 The Siemon Company
The Siemon Company France
Paris, France Tel: (33) 1 46 46 11 85
The Siemon Company Latin America
Coral Gables, Florida USA Tel: (1) 305 446 9150
Latin American Sales
Manufacturer’s Representatives
Castroville, Texas USA Tel: (1) 830 538 6375
The Siemon Company Southeast Asia
Singapore Tel: (65) 285 7579
www.siemon.com
The Siemon Company Australia
Sydney, Australia Tel: (61) 2 89977 7500
The Siemon Company Canada
Markham, Ontario Tel: (1) 905 940 9223
The Siemon Company China
Beijing, P.R. China Tel: (86) 10 6559 8860
The Siemon Company Ltd. Europe & Middle East
Woking, England Tel: (44) (0) 1483 480040
The Siemon Company USA
Watertown, Connecticut Tel: (1) 866 548 5814
®
Loading...