Note: All panel styles have either S110 or S310
style termination posts. All are designed for use
with a standard 110 type punch
HD5 & HD6 Series Wall & Rack Mount Patch Panel Instructions
Vertical Wall Mount Style Panels
Mount S89D bracket with screws (not
included) suitable for mounting
Temporarily snap on vertical panel
with termination side out to allow for
easier cable termination.
Route Cables (For ease of installation)
screws and washers provided,
mount the panel to the desired
location on a 19” equipment
Strip a minimum of 50mm (2 in.)
of cable jacketusing Siemon
Arrange pairs in accordance with the desired wire scheme as
detailed on the color coded sticker provided. Lace conductors
by pressing firmly into position from both sides of lacing post.
Tip: Begin lacing on side of panel wherecables feed from to avoid
cable bundle interference.
19” Flat & Angled Rack Mount
reference to outlet pin #’s on bottom of back page.

HD5 & HD6 Series Wall & Rack Mount Patch Panel Instructions
Watertown, Connecticut USA
For a complete listing of our global offices visit our web site
© 2018 Siemon 12/18 100.11056 Rev.
(tool not perpendicular).
Terminate conductors using a Siemon S814 tool or equivalent
110 style single punch tool. Alternately a high impact multi
punch tool can be used with the S110 style blocks
Snap on termination caps prior to
Note: Screwdriverslot provided
for removal of S310 style.
Attach rear cable manager
into slots provided on rear of
with cable ties or hook & loop
Install manager & secure cables
prevent deforming the cable jacketand potential
transmission performance degradation.
Loosely secure /bundle cables
with cable ties or hook & loop
managers. Panel can now be
flipped back over with port
Peel paper backing from one of the adhesive
backed designation options
holder or icon/label holder (see note 1). Locate
bottom lip of holder to top edge of jacksand
Slide paper label strip into place and/or snap
optional colored icons into holder as desired.
Notes: 1). Both label options not available on some
panel styles. 2). Laser printable labels can be
ordered separately. Visit our web site or contact
Siemon Technical Servicesfor our labeling software
To ensureyou have the latest revision to this document, pleasevisit:
To assistsafe installations, complywith the following:
A. Use cautionwhen installingor modifyingtelecommunications circuits.
B. Never touchuninsulatedwire terminals unlessthe circuit has been disconnected.
C. Never installthis devicein awet location.
D. Never installwiring during a lightning storm.
Lors de l'installation, respectez lesconsignes de sécurité suivantes:
A. Utiliser avec prudence lors del'installationoude lamodification circuits de télécommunications.
B. Ne jamaistoucher les bornes de fil métalliquenon isolés sauf si le circuit aété débranché.
C. Ne jamais installer cetappareil dansun endroithumide.
D. Ne jamais installer pendantun orage.