Siemens SRIF2002 Users Manual

ECOS
SRIF 2002
Operating Instructions
Edition 10/2003
Safety instructions
This document contains instructions you are strongly advised to observe in order to guarantee your personal safety and to avoid personal damages. The instructions are marked by a warning triangle and, depending on the degree of risk, are presented as follows:
!
Warning
means that death or serious physical injuries may be caused if you do not take the respective precautionary measures.
!
Caution
means that minor physical injuries may be caused if you do not take the respective precautionary measures.
Note
provides important information on the product, the product handling or the respective part of the documentation which requires special attention and whose observation is recommendable due to possible advantages.
Use in accordance with specification
Please observe the following:
!
Warning
The device may only be used for applications specified in the catalogue and the technical descriptions. It may further only be used in combination with non-Siemens devices and components which are recommended or approved by Siemens.
Faultless and safe operation is only ensured if the product is transported, stored, mounted and installed properly and if the operation and maintenance is carried out conscientiously.
Copyright Siemens AG 2003, All rights reserved
This document shall not be transmitted or reproduced, nor shall its contents be exploited or disclosed to third persons without prio written consent from Siemens. Infringements shall entitle to damage claims. All rights reserved, in particular in case of a patent grant o utility model registration.
Siemens AG Automation & Drives Business Unit: Automotive Industry Projects, Training Production Automation, Automotive Industry P.O. Box 48 48, D-90327 Nuremberg
Siemens Aktiengesellschaft Printed in the Federal Republic of Germany
Disclaimer of liabilit y
Although we have carefully checked the contents of this publication for conformity with the hardware and software described, we cannot guarantee complete conformity since errors cannot be excluded. The information provided in this manual is checked at regula intervals and any corrections which might becom e necessary are included in the next editions. The contents of this manual are subject to change without prior notice. Any suggestions fo improvement are welcome.
© Siemens AG 2003 Subject to technical changes.
Table of Contents
1 General............................................................................................................................. 5
1.1 Short description .................................................................................................. 6
1.2 Definition of terms ................................................................................................ 6
1.3 Important instructions........................................................................................... 7
1.3.1 General instructions .............................................................................................7
1.3.2 Certificates, guidelines and declarations ............................................................. 8
2 Block Diagram ............................................................................................................... 11
3 Functional Description ................................................................................................. 13
3.1 Radio transmission............................................................................................. 14
3.2 Parameterization via the parallel interface......................................................... 15
3.3 Serial parameterization ...................................................................................... 17
3.4 Serial data interface ........................................................................................... 20
3.5 Notes on the radio operation.............................................................................. 21
4 Settings.......................................................................................................................... 23
4.1 Settings for the DIP switch ................................................................................. 24
4.2 Settings for the operation in the MDA / SDA...................................................... 25
4.3 Settings for the operation in the hand-held terminal .......................................... 25
5 Maintenance and Care.................................................................................................. 27
6 Technical Data............................................................................................................... 29
7 Appendix: Channel / Frequency Table ....................................................................... 31
Operating Instructions SRIF 2002
Page 3 of 33

General

1.1 Short description .................................................................................................. 6
1.2 Definition of terms ................................................................................................ 6
1.3 Important instructions........................................................................................... 7
1.3.1 General instructions .............................................................................................7
1.3.2 Certificates, guidelines and declarations ............................................................. 8
1
Operating Instructions SRIF 2002
Page 5 of 33
General 10/2003
1.1 Short description
The SRIF 2002 is a radio transmitter/receive module (transceiver) for half-duplex data transmission in the 5.8 GHz ISM range. It transmits digital data with a baud rate up to 115.2 kBaud. Depending on the antenna, the installation environment and the frequency band, the transmission range may be up to 15 m, 100 m as a maximum (comparable to free field).
127 different frequencies (radio channels) can be set and used in the 5.8 GHz ISM band.

1.2 Definition of terms

BA Battery Adapter
ECOS Electrical Check Out System
ECOS-i Electrical Check Out System intelligent
FCC Federal Communications Commission
FSK Level Frequency Shift Keying
HT Hand-held Terminal
ISM Industrial, Scientific and Medical Applications
LSB Least Significant Bit
MDA Mobile Diagnosis Adapter
MMCX Type: RF connector with latching element
MPS Mobile Test Station
MSB Most Significant Bit
RF Radio Frequency
RSSI Receive Signal Strength Indicator
SDA Stationary Diagnosis Adapter
SMA Type: RF connector with thread
Page 6 of 33
SRIF Serial Radio InterFace
TRX Transmitter Receiver (product from the ECOS
range)
UART Universal Asynchronous Receiver Transmitter
Operating Instructions SRIF 2002
10/2003 General
1.3 Important instructions
1.3.1 General instructions
Transport
We recommend that you only transport the device in its original packaging (shock and impact protection).
Repairs
Repairing the device is not permitted. Considerable danger may result for the user if the device is opened without authorisation or repairs are carried out improperly.
ESD guidelines
Modules with ESD (electrostatically sensitive devices) may be marked by the following label:
If you use modules with ESD, you are urgently required to observe and follow the following guidelines:
Before you start to work with modules including ESD, you must discharge
All devices and tools used must be free of static charge.
Withdraw the power plug prior to plugging in or withdrawing modules with ESD.
Touch modules with ESD only on the edges.
Do not touch any terminal pins or conductors on a module with ESD.
yourself electrostatically (e.g. by touching an earthed object).
Use only ESD-suitable packaging for shipping.
Operating Instructions SRIF 2002
Page 7 of 33
General 10/2003
1.3.2 Certificates, guidelines and declarations
Notes on the CE certification
The following applies for the product described in these operating instructions:
EC guideline R&TTE 1999/5/EC
The product meets the requirements of the EC guideline R&TTE 1999/5/EC (Radio Equipment and Telecommunications Terminal Equipment) and the corresponding harmonized European standards (EN) published in this context.
SRIF 2002 complies with national and international standards. Radio installations with the SRIF 2002 are ready for approval world-wide.
Any emitted interferences in the transmit and receive mode comply with EN 300 440 (09.2001).
Note on the Declaration of Conformity
In accordance with the above mentioned EC guideline, the EC conformity declarations and the accompanying documentation are available for the responsible authorities at:
SIEMENS AG Automation and Drives A & D PT 34 P.O. Box 4848 D – 90327 Nuremberg
Tel.: +49 911 895 3490 Fax.: +49 911 895 3699
Page 8 of 33
Operating Instructions SRIF 2002
10/2003 General
This device is labelled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used: This device contains transmitter module FCC ID LDS-SRIF2002
FCC approval
FCC FCC ID:LDS-SRIF2002
The product meets the requirements of FCC guideline CFR47 Part15 chapter 249.
Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Observe installation guidelines
The installation and safety guidelines listed in these Operating Instructions must be observed for commissioning and operation.
DIN ISO 9001 certificate
The quality management system of our complete product generation process (development, production and distribution) complies with the DIN ISO 9001 requirements (corresponds to EN29001: 1987).
Operating Instructions SRIF 2002
Page 9 of 33