DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Edition
Remarks
04/2012
First edition
12/2013
General update
Note Use in a domestic environment This is a Class A Group 1 equipment intended for use in industrial areas. In a domestic environment this device may cause radio interference.
WARNING
Using a damaged or incomplete device Danger of explosion in hazardous areas.
Do not use damaged or incomplete devices.
CAUTION
Insufficient protection during storage The packaging only provides limited protection against moisture and infiltration.
Provide additional packaging as necessary.
Symbol
Explanation
Consult operating instructions
Note Functional safety applications (SIL) In case the device is used in a functional safety application, refer to the functional safety manual.
Electromagnetic compatibility EMC 2004/108/EC
Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC.
Low voltage directive LVD 2006/95/EC
Directive of the European Parliament and of the Council on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits.
Atmosphère explosible ATEX 94/9/EC
Directive of the European Parliament and the Council on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres.
Pressure equipment directive PED 97/23/EC
Directive of the European Parliament and of the Council on the approximation of the laws of the Member States concerning pressure equipment.
WARNING
Improper device modifications Danger to personnel, system and environment can result from modifications to the device, particularly in hazardous areas.
Only carry out modifications that are described in the instructions for the device. Failure to observe this requirement cancels the manufacturer's warranty and the product approvals.
Note Operation under special ambient conditions We highly recommend that you contact your Siemens representative or our application department before you operate the
device under special ambient conditions as can be encountered in nuclear power plants or when the device is used for research and development purposes.
WARNING
Unsuitable device for the hazardous area Danger of explosion.
Only use equipment that is approved for use in the intended hazardous area and labelled accordingly.
WARNING
Loss of safety of device with type of protection "Intrinsic safety Ex i" If the device has already been operated in non-intrinsically safe circuits or the electrical specifications have not been
observed, the safety of the device is no longer ensured for use in hazardous areas. There is a danger of explosion.
Connect the device with type of protection "Intrinsic safety" solely to an intrinsically safe circuit.
Observe the specifications for the electrical data in the certificate and in the operating instructions.
CAUTION
Hot surfaces resulting from hot process media Danger of burns resulting from surface temperatures above 70 °C (155 °F).
Take appropriate protective measures, for example contact protection.
Make sure that protective measures do not cause the maximum permissible ambient temperature to be exceeded. See
operating instructions.
WARNING
Wetted parts unsuitable for the process media Danger of injury or damage to device. Hot, toxic and corrosive media could be released if the process medium is unsuitable for the wetted parts.
Ensure that the material of the device parts wetted by the process medium is suitable for the medium. See information in the operating instructions.
Note Material compatibility Siemens can provide you with support concerning selection of sensor components wetted by process media. However, you
are responsible for the selection of components. Siemens accepts no liability for faults or failures resulting from incompatible materials.
WARNING
Unsuitable connecting parts Danger of injury or poisoning. In case of improper mounting hot, toxic and corrosive process media could be released at the connections.
Ensure that connecting parts (such as flange gaskets and bolts) are suitable for connection and process media.
WARNING
Exceeded maximum permissible operating pressure Danger of injury or poisoning. The maximum permissible operating pressure depends on the device version. The device can be damaged if the operating
pressure is exceeded. Hot, toxic and corrosive process media could be released.
Make sure that the device is suitable for the maximum permissible operating pressure of your system. Refer to the information on the nameplate and in the operating instructions.
WARNING
Exceeded maximum ambient or process media temperature Danger of explosion in areas subject to explosion hazard. Device damage.
Make sure that the maximum permissible ambient and process media temperatures of the device are not exceeded. See information in the operating instructions.
WARNING
Open cable inlet or incorrect cable gland Danger of explosion in hazardous areas.
Close the cable inlets for the electrical connections. Only use cable glands or plugs which are approved for the relevant type of protection.
WARNING
Incorrect conduit system Danger of explosion in hazardous areas as result of open cable inlet or incorrect conduit system.
In the case of a conduit system, mount a spark barrier at a defined distance from the device input. Observe national regulations and the requirements stated in the relevant approvals.
CAUTION
External stresses and loads Damage to device by severe external stresses and loads (e.g. thermal expansion or pipe tension). Process media can be
released.
Prevent severe external stresses and loads from acting on the device.
CAUTION
Damage to device In plants with strong vibrations, mount the transmitter in a low vibration environment away from the sensor.
CAUTION
Aggressive atmospheres Damage to device through penetration of aggressive vapors.
Ensure that the device is suitable for the application.
CAUTION
Direct sunlight Device damage. The device can overheat or materials become brittle due to UV exposure.
Protect the device from direct sunlight.
Make sure that the maximum permissible ambient temperature is not exceeded. See operating instructions.
NOTICE
Incorrect mounting The device can be damaged, destroyed, or its functionality impaired through improper mounting.
Before installing ensure there is no visible damage to the device.
Make sure that process connectors are clean, and suitable gaskets and glands are used.
Mount the device using suitable tools. See operating instructions.
Note Loss of degree of protection Damage to device if the enclosure is open or not properly closed. The degree of protection specified on the nameplate and
in the operating instructions is no longer guaranteed.
Make sure that the device is securely closed.
WARNING
Incorrect disassembly The following dangers may result through incorrect disassembly:
- Injury through electric shock
- Danger through emerging media when connected to the process
- Danger of explosion in hazardous area
In order to disassemble correctly, observe the following:
Before starting work, make sure that you have switched off all physical variables such as pressure, temperature, electricity etc. or that they have a harmless value.
If the device contains dangerous media, it must be emptied prior to disassembly. Make sure that no environmentally hazardous media are released.
Secure the remaining connections so that no damage can result if the process is started unintentionally.
WARNING
Unsuitable cables and/or cable glands Danger of explosion in hazardous areas.
Only use suitable cables and cable glands complying with the requirements specified under technical data in the operating instructions.
Tighten the cable glands in accordance with the torques specified under technical data in the operating instructions.
When replacing cable glands use only cable glands of the same type.
After installation, check that the cables are seated firmly.
WARNING
Dangerous contact voltage Danger of electric shock in case of incorrect connection.
For the electrical connection specifications, see technical data in the operating instructions
At the mounting location of the device observe the applicable directives and laws for installation of electrical power
installations with rated voltages below 1000 V.
NOTICE
Condensation in the device Damage to device through formation of condensation if the temperature difference between transportation or storage and
the mounting location exceeds 20 °C (68°F).
Before taking the device into operation let the device adapt for several hours in the new environment.
WARNING
Missing PE/ground connection Danger of electric shock. Ensure the PE/ground connection is secure before applying power.
NOTICE
Ambient temperature too high Damage to cable sheath.
● At an ambient temperature ≥ 60 °C (140 °F), use heat-resistant cables suitable for an ambient temperature at least 20 °C (68 °F) higher.
WARNING
Improper power supply Danger of explosion in hazardous areas as result of incorrect power supply, e.g. using direct current instead of alternating
current.
Connect the device in accordance with the specified power supply and signal circuits. The relevant specifications can be found in the certificates found in the operating instructions or on the nameplate.
WARNING
Lack of equipotential bonding Danger of explosion through compensating currents or ignition currents through lack of equipotential bonding.
Ensure that the device is potentially equalized.
WARNING
Unprotected cable ends Danger of explosion through unprotected cable ends in hazardous areas.
Protect unused cable ends in accordance with IEC/EN 60079-14.
WARNING
Improper laying of shielded cables Danger of explosion through compensating currents between hazardous area and the non-hazardous area.
Only ground shielded cables that run into the hazardous area at one end.
If grounding is required at both ends, use an equipotential bonding conductor.
WARNING
Insufficient isolation of non-intrinsically safe and intrinsically safe circuits Danger of explosion in hazardous areas.
When connecting intrinsically safe and non-intrinsically safe circuits ensure that isolation is carried out properly in accordance with IEC/EN 60079-14.
Make sure that you observe the device approvals applicable in your country.
WARNING
Connecting device in energized state Danger of explosion in hazardous areas.
Connect devices in hazardous areas only in a de-energized state.
Exceptions:
Circuits of limited energy may also be connected in the energized state in hazardous areas.
Exceptions for type of protection "Non-sparking nA" (Zone 2) are regulated in the relevant certificate
WARNING
Incorrect selection of type of protection Danger of explosion in areas subject to explosion hazard. This device is approved for several types of protection.
1. Decide in favor of one type of protection.
2. Connect the device in accordance with the selected type of protection.
3. In order to avoid incorrect use at a later point, make the types of protection that are not used permanently unrecognizable on the nameplate.
Note Electromagnetic compatibility (EMC) You can use this device in industrial environments, households and small businesses. For metal housings there is an increased electromagnetic compatibility compared to high-frequency radiation. This
protection can be increased by grounding the housing, see operating instructions.
Note Improvement of interference immunity
Lay signal cables separate from cables with voltages > 60 V.
Use cables with twisted wires.
Keep device and cables in distance to strong electromagnetic fields.
Use shielded cables to guarantee the full specification according to HART.
Connect a load resistor of at least 230 Ω in series in the signal circuit in order to guarantee fault-free HART
communication. When power supply isolators are used for SITRANS HART transmitters, a load resistor is already installed in the device.
WARNING
Improper commissioning in hazardous areas Device failure or danger of explosion in hazardous areas.
Do not commission the device until it has been mounted completely and connected in accordance with the information found under technical data in the operating instructions.
Before commissioning take the effect on other devices in the system into account.
WARNING
Commissioning and operation with pending error If an error message appears, correct operation in the process is no longer guaranteed.
Check the gravity of the error.
Correct the error.
If the error still exists: Take the device out of operation. Prevent renewed commissioning.
WARNING
Hot surfaces Danger of burns resulting from hot surfaces.
Take corresponding protective measures, for example by wearing protective gloves.
Note Loss of degree of protection Damage to device if the enclosure is open or not properly closed. The degree of protection specified on the nameplate and
in the operating instructions is no longer guaranteed.
Make sure that the device is securely closed.
WARNING
Dangerous contact voltage Danger of injury through dangerous contact voltage when the device is open or not completely closed. The degree of protection specified on the nameplate and in the operating instructions is no longer guaranteed if the device
is open or not properly closed.
Make sure that the device is securely closed.
DANGER
Toxic gases and liquids Danger of poisoning when venting the device: if toxic process media are measured, toxic gases and liquids can be
released.
Before venting ensure that there are no toxic gases or liquids in the device, or take the appropriate safety measures.
WARNING
Loss of explosion protection Danger of explosion in hazardous areas if the device is open or not properly closed.
Close the device.
WARNING
Opening device in energized state Danger of explosion in areas subject to explosion hazard.
Only open the device in a de-energized state.
Check prior to commissioning that the cover, cover locks, and cable inlets are assembled in accordance with the
directives.
Note The device is maintenance-free.
NOTICE
Repair and service must be carried out by Siemens authorized personnel only.
Note Siemens defines flow sensors as non-repairable products.
WARNING
Impermissible repair and maintenance of the device
Repair and maintenance must be carried out by Siemens authorized personnel only.
WARNING
Impermissible repair of explosion protected devices Danger of explosion in areas subject to explosion hazard.
Repair must be carried out by Siemens authorized personnel only.
WARNING
Dust layers above 5 mm Danger of explosion in hazardous areas. Device may overheat due to dust build up.
Remove dust layers in excess of 5 mm.
NOTICE
Penetration of moisture into the device Device damage.
Make sure when carrying out cleaning and maintenance work that no moisture penetrates the inside of the device.
CAUTION
Releasing key lock Improper modification of parameters could influence process safety.
Make sure that only authorized personnel may cancel the key locking of devices for safety-related applications.
WARNING
Maintenance during continued operation in a hazardous area There is a danger of explosion when carrying out repairs and maintenance on the device in a hazardous area.
Isolate the device from power.
- or -
Ensure that the atmosphere is explosion-free (hot work permit).
WARNING
Impermissible accessories and spare parts Danger of explosion in areas subject to explosion hazard.
Only use original accessories or original spare parts.
Observe all relevant installation and safety instructions described in the instructions for the device or enclosed with the
accessory or spare part.
WARNING
Humid environment Danger of electric shock.
Avoid working on the device when it is energized.
If working on an energized device is necessary, ensure that the environment is dry.
Make sure when carrying out cleaning and maintenance work that no moisture penetrates the inside of the device.
CAUTION
Hot surfaces Danger of burns during maintenance work on parts having surface temperatures exceeding 70 °C (158 °F).
Take corresponding protective measures, for example by wearing protective gloves.
After carrying out maintenance, remount touch protection measures.
WARNING
Enclosure open Danger of explosion in hazardous areas as a result of hot components and/or charged capacitors inside the device. Proceed as follows to open the device in a hazardous area:
1. Isolate the device from power.
2. Observe the wait time specified in the operating instructions or on the warning sign before opening the device.
WARNING
Hot, toxic or corrosive process media Danger of injury during maintenance work. When working on the process connection, hot, toxic or corrosive process media could be released.
As long as the device is under pressure, do not loosen process connections and do not remove any parts that are pressurized.
Before opening or removing the device ensure that process media cannot be released.
WARNING
Improper connection after maintenance Danger of explosion in areas subject to explosion hazard.
Connect the device correctly after maintenance.
Close the device after maintenance work.
CAUTION
Corrosive substances Danger of chemical burns when replacing the sensor. The sensor in the device contains corrosive substances that result in burns on unprotected skin.
Make sure that the sensor enclosure is not damaged when replacing the sensor.
If contact with the corrosive substances occurs, rinse the affected skin immediately with large amount of water to dilute
substance.
Devices identified by this symbol may not be disposed of in the municipal waste disposal services under observance of the Directive 2002/96/EC on waste electronic and electrical equipment (WEEE).
They can be returned to the supplier within the EC or to a locally approved disposal service. Observe the specific regulations valid in your country.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG
SITRANS FC430 with HART (7ME4613, 7ME4603, 7ME4623, 7ME4713) A5E03736889 , 12/2013
DANGER
signifie que la non-application des mesures de sécurité appropriées entraîne la mort ou des blessures graves.
ATTENTION
signifie que la non-application des mesures de sécurité appropriées peut entraîner la mort ou des blessures graves.
PRUDENCE
signifie que la non-application des mesures de sécurité appropriées peut entraîner des blessures légères.
IMPORTANT
signifie que la non-application des mesures de sécurité appropriées peut entraîner un dommage matériel.
ATTENTION
Les produits Siemens ne doivent être utilisés que pour les cas d'application prévus dans le catalogue et dans la documentation technique correspondante. S'ils sont utilisés en liaison avec des produits et composants d'autres marques, ceux-ci doivent être recommandés ou
agréés par Siemens. Le fonctionnement correct et sûr des produits suppose un transport, un entreposage, une mise en place, un montage, une mise en service, une utilisation et une maintenance dans les règles de l'art. Il faut respecter les conditions d'environnement admissibles ainsi que les indications dans les documentations afférentes.
Edition
Commentaires
04/2012
Première édition
12/2013
Mise à jour générale
Remarque Utilisation dans un environnement domestique
Cet équipement appartient à la classe A, groupe 1 et a été conçu pour une utilisation en environnement industriel. Il peut provoquer des perturbations radioélectriques s'il est utilisé dans un environnement domestique.
ATTENTION
Utilisation d'un appareil endommagé ou incomplet Danger d'explosion dans des zones à risque d'explosion.
● N'utilisez pas d'appareils endommagés ou incomplets.
PRUDENCE
Protection insuffisante pendant le stockage L'emballage n'assure qu'une protection limitée contre l'humidité et les infiltrations.
● Assurez un emballage supplémentaire si nécessaire.
Symbole
Explication
Consultez les instructions de service
Remarque
Applications de sécurité fonctionnelle (SIL) Si vous utilisez l'appareil dans une application de sécurité fonctionnelle, référez-vous au manuel sur la sécurité fonctionnelle.
Compatibilité électromagnétique
(CEM) 2004/108/CE
Directive du Parlement européen et du Conseil relative au rapprochement des législations des États membres concernant la compatibilité électromagnétiqueet
abrogeant la directive 89/336/CEE.
Directive basse tension (DBT) 2006/95/CE
Directive du Parlement européen et du Conseil concernant le rapprochement des législations des États membres relatives au matériel électrique destiné à être employé dans certaines limites de tension.
ATEX 94/9/CE
Directive du Parlement européen et du Conseil concernant le rapprochement des législations des États membres pour les appareils et les systèmes de protection destinés à être utilisés en atmosphères explosibles.
Directive équipements sous pression
(DESP) 97/23/CE
Directive du Parlement Européen et du Conseil relative au rapprochement des législations des États membres concernant les équipements sous pression.
ATTENTION
Modifications de l'appareil Les modifications et réparations de l'appareil, en particulier en atmosphère explosible, peuvent mettre le personnel,
l'installation et l'environnement en danger.
Ne modifiez ou réparez l'appareil que comme cela est décrit dans la notice de l'appareil. En cas de non-respect, la garantie du fabricant et les homologations de produit perdent leur validité.
Remarque Exploitation dans des conditions ambiantes spéciales
Avant d'utiliser l'appareil dans des conditions ambiantes spéciales (dans une centrale nucléaire, par exemple) ou à des fins de recherche et de développement, nous vous recommandons vivement de contacter votre représentant Siemens ou notre
division application.
ATTENTION
Appareil non adapté aux zones à risque Risque d'explosion.
● Pour une exploitation en zone à risque d'explosion, utilisez uniquement des équipements homologués et étiquetés en conséquence.
ATTENTION
Perte de la fonction de sécurité avec le type de protection "Sécurité intrinsèque Ex i" Si l'appareil a déjà été exploité dans des circuits à sécurité non intrinsèque ou si les caractéristiques électriques n'ont pas
été observées, la sécurité de l'appareil n'est plus garantie pour une utilisation en zone à risque d'explosion. Il y a un risque
d'explosion.
● Ne raccordez l'appareil présentant le type de protection "sécurité intrinsèque" qu'à un circuit à sécurité intrinsèque.
● Observez les caractéristiques des données électriques indiquées sur le certificat et dans les instructions de service.
PRUDENCE
Surfaces chaudes dues aux milieux chauds utilisés dans le procédé Risque de brûlure dû à des températures de surface supérieures à 70 °C (155 °F).
● Prenez des mesures adaptées, permettant par exemple de se protéger de tout contact.
● Veillez à ce que ces mesures de protection n'entraînent pas le dépassement de la température ambiante maximale autorisée. Consultez les instructions de service.
ATTENTION
Pièces humides non adaptées au milieu dans lequel se déroule le procédé Risque de se blesser ou d'endommager l'appareil.
Des substances chaudes, toxiques et corrosives peuvent s'échapper si le milieu dans lequel se déroule le procédé n'est pas adapté aux pièces avec lequel il est en contact.
● Veillez à ce que le matériau des pièces de l'appareil en contact avec le milieu du procédé soit adapté à ce milieu.
Consultez les informations figurant dans les instructions de service.
Remarque
Compatibilité des matériaux Siemens peut vous assister dans le choix des composants du capteur mouillés par le milieu du procédé. Vous êtes
cependant responsable du choix des composants. Siemens décline toute responsabilité en cas de défauts ou de défaillances résultant de l'incompatibilité des matériaux.
ATTENTION
Pièces de raccordement non adaptées Risque de blessure ou d'empoisonnement.
En cas de montage incorrect, des milieux chauds, toxiques et corrosifs utilisés dans le procédé peuvent s'échapper au
niveau des raccords.
● Veillez à ce que les pièces de raccordement (telles que les joints pour brides et les boulons) soient adaptées aux raccords et aux milieux utilisés pour le procédé.
ATTENTION
Dépassement de la pression de service maximale autorisée Risque de blessure ou d'empoisonnement. La pression de service maximale autorisée dépend de la version de l'appareil. L'appareil peut être endommagé en cas de
dépassement de la pression de service. Des milieux chauds, toxiques et corrosifs utilisés dans le procédé peuvent s'échapper.
● Assurez-vous que l'appareil est adapté pour la pression de service maximale autorisée de votre système. Reportez­vous aux informations figurant sur la plaque signalétique et dans les instructions de service.
ATTENTION
Dépassement de la température ambiante maximale ou de celle des milieux du procédé Risque d'explosion dans les zones explosives.
Dommages causés à l'appareil.
● Veillez à ce que les températures maximales de l'appareil (température ambiante et température des milieux du procédé) ne soient pas dépassées. Consultez les informations figurant dans les instructions de service.
ATTENTION
Entrée de goulotte ouverte ou presse-étoupe incorrect Danger d'explosion dans des zones à risque d'explosion.
● Fermez les goulottes d'entrée destinées aux raccordements électriques. Utilisez uniquement des presse-étoupes ou des connecteurs homologués pour le type de protection pertinent.
ATTENTION
Système de conduits incorrect Risque d'explosion dans des zones à risque dû à une entrée de goulotte ouverte ou à un système de conduits incorrect.
● Dans le cas d'un système de conduits, monte un pare-étincelles à une distance définie de l'entrée de l'appareil. Observez les règlements nationaux et les exigences mentionnées dans les homologations correspondantes.
PRUDENCE
Contraintes externes et charges
Endommagement de l'appareil dû à des contraintes et des charges externes élevées (p. ex. dilatation thermique ou tuyau en traction). Des milieux utilisés dans le procédé peuvent s'échapper.
Evitez que des contraintes et des charges externes ne s'exercent sur l'appareil.
PRUDENCE
Dommage causé à l'appareil Dans les usines soumises à de fortes vibrations, monter le transmetteur dans un environnement soumis à de faibles
vibrations à l'écart du capteur.
PRUDENCE
Atmosphères agressives Appareil endommagé en raison de la pénétration de vapeurs agressives.
Assurez-vous que l'appareil convient pour l'application.
PRUDENCE
Lumière directe du soleil Dommages causés à l'appareil. L'appareil peut être en surchauffe ou les matériaux peuvent se fragiliser sous l'effet de l'exposition aux UV.
● Protéger l'appareil de la lumière directe du soleil.
● Veillez à ce que la température ambiante maximale autorisée ne soit pas dépassée. Consultez les instructions de
service.
IMPORTANT
Montage incorrect
Un montage incorrect peut endommager l'appareil, le détruire ou réduire ses fonctionnalités.
Avant de l'installer, assurez-vous que l'appareil ne comporte aucun défaut visible.
● Veillez à ce que les connecteurs du procédé soient propres, et que des joints et presse-étoupes appropriés sont utilisés.
● Montez l'appareil à l'aide d'outils adaptés. Consultez les instructions de service.
Remarque
Réduction du degré de protection Si le boîtier est ouvert ou n'est pas correctement fermé, l'appareil est susceptible d'être endommagé. Le degré de protection
spécifié sur la plaque signalétique ou dans les instructions de service n'est plus garanti.
Assurez-vous que l'appareil est bien fermé.
ATTENTION
Démontage incorrect Les dangers suivants peuvent survenir du fait d'un démontage incorrect :
- Blessure par choc électrique
- Danger par un contenu émergent lors du raccordement au processus
- Danger d'explosion en zone à risque d'explosion
Pour assurer un démontage correct, respectez les consignes suivantes :
● Avant toute chose, veillez à ce que les variables physiques telles que la pression, la température, l'électricité etc. soient mises hors tension ou que leur valeur ne présente aucun danger.
● Si l'appareil contient des matières présentant un risque d'explosion, il doit être purgé avant tout démontage. Assurez­vous alors qu'aucune matière dangereuse pour l'environnement ne s'échappe.
Fixez les lignes restantes de sorte à éviter tout dommage en cas de démarrage accidentel du processus.
ATTENTION
Câbles et/ou presse-étoupes non adaptés Danger d'explosion dans des zones à risque d'explosion.
● Utilisez uniquement des câbles et des presse-étoupes appropriés qui satisfont aux exigences figurant dans "Caractéristiques techniques" dans les instructions de service.
Serrez les presse-étoupes en respectant les couples indiqués dans "Caractéristiques techniques" dans les instructions
de service.
● Lorsque vous remplacez les presse-étoupes, utilisez uniquement des presse-étoupes du même type.
● Après l'installation, vérifiez que les câbles sont bien serrés.
ATTENTION
Tension dangereuse par contact
Risque d'électrocution en cas de connection incorrecte.
Reportez-vous à "Caractéristiques techniques" dans les instructions de service pour les spécifications de la connexion électrique.
● Sur le lieu de montage de l'appareil, observez les directives et la législation en vigueur pour la mise en place d'installations électriques de tensions nominales inférieures à 1000 V.
IMPORTANT
Condensation à l'intérieur de l'appareil La formation de condensation peut endommager l'appareil si la différence de température entre le transport ou le lieu de
stockage et le site de montage est supérieure à 20 °C (68 °F).
Avant de mettre en service l'appareil, laissez-le s'adapter à son nouvel environnement pendant quelques heures.
ATTENTION
Raccordement PE/à la terre manquant Risque d'électrocution. Vérifiez que le raccordement PE/terre est sûr avant d'effectuer la mise sous tension.
IMPORTANT
Température ambiante trop élevée Endommagement de la gaine du câble.
● Pour une température ambiante ≥ 60 °C (140 °F), n'utilisez que des câbles résistants à la chaleur adaptés à une température ambiante d'au moins 20 °C (68 °F) plus élevée.
ATTENTION
Alimentation incorrecte Risque d'explosion dans les zones à risque résultant d'une alimentation incorrecte, utilisant p. ex. du courant continu au
lieu d'utiliser du courant alternatif.
● Connectez l'appareil en respectant l'alimentation et les circuits de signaux spécifiés. Les spécifications appropriées figurent dans les certificats, dans les instructions de service ou sur la plaque signalétique.
ATTENTION
Liaison équipotentielle manquante Risque d'explosion dû aux courants compensateurs ou aux courants d'allumage en raison d'une liaison équipotentielle
manquante.
Assurez-vous que l'appareil présente une équipotentialité complète.
ATTENTION
Terminaisons de câbles non protégées Risque d'explosion dû à des extrémités de câble non protégées dans des zones à risque.
● Protégez les extrémités des câbles non utilisées conformément à la norme CEI/EN 60079-14.
ATTENTION
Pose de câbles blindés incorrecte Risque d'explosion dû aux courants compensateurs entre la zone à risque d'explosion et la zone de sécurité.
● Seules les conducteurs de masse (située à l'une de leurs extrémités) blindés peuvent se situer en zone à risque
d'explosion.
Si la mise à la terre est requise pour les deux extrémités, utilisez un conducteur d'égalisation de potentiel.
ATTENTION
Isolation insuffisante des circuits à sécurité non intrinsèque et intrinsèque Danger d'explosion dans des zones à risque d'explosion.
● Lors de la connexion de circuits à sécurité intrinsèque et à sécurité non intrinsèque, assurez-vous que l'isolation est effectuée correctement conformément à la norme IEC/EN 60079-14.
Assurez-vous que vous respectez les homologations de l'appareil en vigueur dans votre pays.
ATTENTION
Raccorder l'appareil sous tension
Danger d'explosion dans des zones à risque d'explosion.
● Dans les zones à risques, ne raccorder l'appareil que lorsqu'il est hors tension.
Exceptions :
● Les circuits à énergie limitée peuvent être raccordés dans des zones à risques même lorsqu'ils sont sous tension.
● Les exceptions pour le type de protection "Sans étincelles nA" (zone 2) sont réglementées par le certificat
correspondant.
ATTENTION
Choix du type de protection incorrect Risque d'explosion dans les zones explosives. Cet appareil est homologué pour différents types de protection.
1. Choisissez l'un des types de protection.
2. Raccordez l'appareil en fonction du type de protection choisi.
3. Afin d'éviter toute erreur d'utilisation par la suite, masquez les types de protection qui ne sont pas utilisés en permanence sur la plaque signalétique.
Remarque Compatibilité électromagnétique (CEM) Vous pouvez utilisez cet appareil en environnement industriel, pour un usage domestique et dans les petites entreprises.
Les boîtiers métalliques présentent une compatibilité électromagnétique augmentée par rapport à la radiation haute fréquence. Cette protection peut être augmentée en effectuant une mise à la terre du boîtier, voir les instructions de service.
Remarque
Amélioration de l'immunité aux perturbations
● Disposez les câbles de signaux séparément des câbles de tension > 60 V.
● Utilisez des câbles dotés de fils torsadés.
● Eloignez l'appareil et les câbles des champs électromagnétiques forts.
● Utilisez des câbles blindés pour garantir l'entière spécification selon HART.
● Connectez une résistance de charge d'au moins 230 Ω en série dans la boucle du signal afin de garantir une communication HART sans erreur. Si l'on utilise des interrupteurs-séparateurs d’alimentation pour transmetteurs SISTRANS HART, une résistance de charge est déjà installée dans l'appareil.
ATTENTION
Mise en service incorrecte dans les zones à risque Défaillance de l'appareil ou risque d'explosion dans les zones à risque.
● Ne mettez pas en service l'appareil tant qu'il n'a pas été complètement monté et connecté conformément aux informations figurant dans « caractéristiques techniques » dans les instructions de service.
● Avant la mise en service, tenez compte des effets sur les autres appareils du système.
ATTENTION
Mise en service et exploitation en présence d'un message d'erreur Si un message d'erreur apparaît, une opération correcte durant le procédé n'est plus garantie.
● Contrôlez la gravité de l'erreur.
Corrigez l'erreur.
Si l'erreur persiste : Mettez l'appareil hors service. – Empêchez une nouvelle mise en service.
ATTENTION
Surfaces chaudes
Risque de brûlure en raison de surfaces chaudes.
Prenez les mesures de protection correspondantes, par exemple en portant des gants de protection.
Remarque
Réduction du degré de protection Si le boîtier est ouvert ou n'est pas correctement fermé, l'appareil est susceptible d'être endommagé. Le degré de protection
spécifié sur la plaque signalétique ou dans les instructions de service n'est plus garanti.
Assurez-vous que l'appareil est bien fermé.