Siemens SITRANS CU02 Operating Instructions Manual

___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SITRANS
Acoustic Sensors SITRANS CU02
Operating Instructions
03/2017
A5E40873245_AA
About the SITRANS CU 02
1
Specifications
2
Installation
3
Interconnection
4
Operation
5
Setting Up
6
Programming
7
Security Alteration
8
Maintenance
9
Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY
Document order number: A5E40873245
Copyright © Siemens AG 2017. All rights reserved
Legal information
Warning notice system
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
The product/system described in this documentation may be operated only by task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
for the specific
10/2018 Subject to change
Table of contents
1 About the SITRANS CU 02 ..................................................................................................................... 5
2 Specifications .......................................................................................................................................... 7
3 Installation .............................................................................................................................................. 9
4 Interconnection ..................................................................................................................................... 13
5 Operation .............................................................................................................................................. 17
6 Setting Up ............................................................................................................................................. 21
7 Programming ........................................................................................................................................ 23
8 Security Alteration ................................................................................................................................. 27
9 Maintenance ......................................................................................................................................... 29
1.1 Overview ................................................................................................................................... 5
3.1 Mounting ................................................................................................................................... 9
3.2 Rail mounting .......................................................................................................................... 10
4.1 Connection Layout .................................................................................................................. 13
4.2 SITRANS AS 100 Sensor Connection .................................................................................... 14
5.1 Start Delay .............................................................................................................................. 17
5.2 Display .................................................................................................................................... 17
5.3 Relay ....................................................................................................................................... 18
5.4 Analog Output ......................................................................................................................... 19
6.1 Setting Up ............................................................................................................................... 21
6.2 Operating values ..................................................................................................................... 22
7.1 Calibration: 0 - 100% / 4 - 20 mA ............................................................................................ 23
7.2 Relays ..................................................................................................................................... 23
7.3 Ancillary Functions .................................................................................................................. 25
7.4 Parameter List ......................................................................................................................... 26
SITRANS CU02 Operating Instructions, 03/2017, A5E40873245_AA
3
Table of contents
SITRANS CU02
4 Operating Instructions, 03/2017, A5E40873245_AA
1
1.1

Overview

Note
SITRANS CU 02 is to be used only in the manner outlined in this instruction manual.
Features
The SITRANS CU 02 is an alarm control unit for use with SITRANS AS 100 acoustic sensor.
LCD display
2 SPDT (form C) relays
4 - 20 mA output, isolated
programmable start up delay
programmable alarm delay
SITRANS CU02 Operating Instructions, 03/2017, A5E40873245_AA
5
About the SITRANS CU 02
1.1 Overview
SITRANS CU02
6 Operating Instructions, 03/2017, A5E40873245_AA
2
Power :
Environmental :
Sensor Excitation :
Input :
Display :
for operation status
Relay :
Analog Output :
Cable :
equivalent
equivalent
Accuracy :
Enclosure :
see nameplate for voltage configuration (100/115/200/230 V ac ±15%, 50/60 Hz, 10 VA)
location:
altitude:
ambient temperature:
relative humidity:
installation category:
pollution degree:
26 Vdc nominal, 70 mA max
SITRANS Sensor 0 – 10 Vdc
liquid crystal
2 alarm/control relays
1 form ‘C’ SPDT contact per relay, rated 5 A at 250 V ac non inductive
isolated 4 - 20 mA
750 Ω load max
indoor
2000 m max
-20 to 50 °C (-4 to 122 °F)
80% for temperatures up to 50 °C
II
2
three 9 mm (0.35") digits multisegment graphic
SITRANS CU02 Operating Instructions, 03/2017, A5E40873245_AA
analog output
latch contact input:
±0.02V (display) or ±40μA (mA output)
55 mm W x 75 mm H x 110 mm D (2.2" W x 3" H x 4.4" D)
polycarbonate
mounting:
Belden 8760 18AWG shielded twisted pair or
Belden 8760 18AWG shielded twisted pair or
DIN rail (DIN 46277 or DIN EN50022)
wall / panel mount
7
Specifications
Ingress Protection :
Approval :
Weight :
IP 20
CSA general purpose
550 g (18 oz)
SITRANS CU02
8 Operating Instructions, 03/2017, A5E40873245_AA
3
Note
Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures.
3.1

Mounting

Mounting slot (2 places).
Dimensions
SITRANS CU02 Operating Instructions, 03/2017, A5E40873245_AA
9
Loading...